AECMA PREN 3155-034-2005 Aerospace series Electrical contacts used in elements of connection Part 034 Contacts electrical triaxial size 08 male type D crimp class R Product standar.pdf

上传人:proposalcash356 文档编号:420006 上传时间:2018-11-06 格式:PDF 页数:13 大小:526.25KB
下载 相关 举报
AECMA PREN 3155-034-2005 Aerospace series Electrical contacts used in elements of connection Part 034 Contacts electrical triaxial size 08 male type D crimp class R Product standar.pdf_第1页
第1页 / 共13页
AECMA PREN 3155-034-2005 Aerospace series Electrical contacts used in elements of connection Part 034 Contacts electrical triaxial size 08 male type D crimp class R Product standar.pdf_第2页
第2页 / 共13页
AECMA PREN 3155-034-2005 Aerospace series Electrical contacts used in elements of connection Part 034 Contacts electrical triaxial size 08 male type D crimp class R Product standar.pdf_第3页
第3页 / 共13页
AECMA PREN 3155-034-2005 Aerospace series Electrical contacts used in elements of connection Part 034 Contacts electrical triaxial size 08 male type D crimp class R Product standar.pdf_第4页
第4页 / 共13页
AECMA PREN 3155-034-2005 Aerospace series Electrical contacts used in elements of connection Part 034 Contacts electrical triaxial size 08 male type D crimp class R Product standar.pdf_第5页
第5页 / 共13页
亲,该文档总共13页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、ASD STANDARD NORME ASD ASD NORM prEN 3155-034 Edition P 1 October 2005 PUBLISHED BY THE AEROSPACE AND DEFENSE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Gulledelle 94 - B-1200 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 775 8111 - www.asd-stan.orgICS: 49.060 Descriptors: Aerospace industry

2、, aircraft equipment, element of electrical connection, electrical contact,characteristic, marking ENGLISH VERSION Aerospace series Electrical contacts used in elements of connection Part 034: Contacts, electrical, triaxial, size 08, male, type D, crimp, class R Product standard Srie arospatiale Con

3、tacts lectriques utiliss dans les organes de connexion Partie 034 : Contacts lectriques triaxiaux, taille 08, mles, type D, sertir, classe R Norme de produit Luft- und Raumfahrt Elektrische Kontakte zur Verwendung in Verbindungselementen Teil 034: Elektrische triaxiale, Grsse 08, Stiftkontakte, Typ

4、D, crimpbar, Klasse R Product Norm This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The European Association of Aerospace Industries - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by th

5、e experts of the concerned Domain following member comments. Subsequent to the publication of this pre-standard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and r

6、eview by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giv

7、ing the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 31 October 2005 Comments should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2005 by ASD-STAN Copyright

8、Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3155-034:2005Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical

9、 Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. Contents Page Introduction 3 1 Scope . 3 2 Normative references 3 3 Terms and definitions . 4 4 Requirements chara

10、cteristics 4 4.1 Specific characteristics. 4 4.2 Dimensions and mass 4 4.3 Marking by colour code 6 4.4 Material, surface treatment . 6 4.5 Typical cables 6 4.6 Cable stripping and wiring method . 7 4.7 Tooling 9 4.7.1 Crimping tools. 9 4.7.2 Insertion/Extraction tools . 9 4.8 Tests 9 4.9 Gauges . 1

11、2 5 Designation. 12 6 Marking 13 7 Conditioning 13 8 Technical specification 13 2 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3155-034:2005Int

12、roduction The electrical contacts defined in this standard are derived from and interchangeable with those of standard MIL-C-39029/96. They are also interchangeable with those of standard EN 3155-042. 1 Scope This standard specifies the required characteristics, tests and tooling applicable to male

13、electrical triaxial contacts, size 08, type D, crimp, class R, used in element of connection according to EN 3155-002. It shall be used together with EN 3155-001. The associated female contacts are defined in EN 3155-035 and EN 3155-043. 2 Normative references The following referenced documents are

14、indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2591*, Aerospace series Elements of electrical and optical connection Test methods. E

15、N 3155-001, Aerospace series Electrical contacts used in elements of connection Part 001: Technical specification.1)EN 3155-002, Aerospace series Electrical contacts used in elements of connection Part 002: List and utilization of contacts.1)EN 3155-035, Aerospace series Electrical contacts used in

16、elements of connection Part 035: Contacts, electrical, triaxial, size 08, female, type D, crimp, class R Product standard.1)EN 3155-042, Aerospace series Electrical contacts used in elements of connection Part 042: Contacts, electrical, triaxial, size 08, male 042, type D, solder, class P Product st

17、andard.1)EN 3155-043, Aerospace series Electrical contacts used in elements of connection Part 043: Contacts, electrical, triaxial, size 08, female 043, type D, solder, class P Product standard.1)EN 3682-001, Aerospace series Connectors, plug and receptacle, electrical, rectangular, interchangeable

18、insert type, rack to panel, operating temperature 150 C continuous Part 001: Technical specification.1)EN 4008-009, Aerospace series Elements of electrical and optical connection Accessories and special tooling Part 009: Positioner for crimping tool M22520/2 electrical contacts according to EN 3155-

19、010 and EN 3155-011 Product standard.2) * All parts quoted in this standard. 1) Published as AECMA Prestandard at the date of publication of this standard. 2) In preparation at the date of publication of this standard. 3 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provi

20、ded by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3155-034:2005EN 4530-005, Aerospace series Sealing sleeves used in elements of connection Part 005: Sealing sleeves for external diameter cable 3 mm to 4,1 mm Product standard.2

21、)MIL-DTL-22520, Crimping tools, terminal, hand or power actuated, wire termination, and tool kits general specification for.3)MIL-C-39029/96, Contacts, electrical connector, concentric twinax, pin, size 8.3)MIL-I-81969/14, Installing and removal Tools, Connector electrical Contact, Type III, Class 2

22、, Composition B for.3) TR 6058, Aerospace series Cable code identification list.4)3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 3155-001 apply. 4 Requirements characteristics 4.1 Specific characteristics Type D contacts are for application where con

23、tacts with a screening feature are requested and class R corresponds to an operating temperature range from 65 C to 150 C. 4.2 Dimensions and mass See Figure 1. Dimensions and tolerances are given in millimetres and apply after surface treatment. Mass of the contact: 5,2 g max. 3) Published by: Depa

24、rtment of Defense (DOD), The Pentagon, Washington D.C. 20301, USA. 4) Published as AECMA Technical Report at the date of publication of this standard. 4 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or

25、networking permitted without license from IHS-,-,-prEN 3155-034:2005Key 1 Ref. : 0,76 2 Spherical end 3 0,2 max. flat permitted aDiameter of outside after wiring bPoint of contact with a flat-ended gauge pin of diameter 2,87 0,005 cDiameter compatible with intermediate pin diameter 2,87 0,025 dEnd o

26、f contact centre pin Figure 1 Key Key 1 on ferrule 1 on ferrule 86,491,486,491,4Figure 2 Ferrule for cable group A Figure 3 Ferrule for cable group B 5 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or n

27、etworking permitted without license from IHS-,-,-prEN 3155-034:20054.3 Marking by colour code Not applicable 4.4 Material, surface treatment Outer body material (male) : copper alloy Intermediate contact (female) : copper alloy Center contact (male) : copper alloy Crimp ferrule : copper alloy Surfac

28、e treatment : gold on appropriate undercoat, thickness of protection not specified, selective protection permitted. Dielectric : PTFE 4.5 Typical cables See Figure 4 and Table 1. Figure 4 Table 1 Dimensions of cable A B C Cable code group Permissible cable code according to TR 6058 min. max. max. Br

29、aid composition min. max. A 0,55 0,62 1,3 1 braid of 0,1 coated copper wire overall diameter: 3 mm max. 3 3,5 WJ 0,55 0,62 1,3 2 braid of 0,1 coated copper wire overall diameter: 3,5 mm max. 3,4 3,9 B WV 0,55 0,62 1,3 2 braid of 0,1 coated copper wire. 1 high immunity tape overall diameter: 3,75 max

30、. 3,6 4,1 6 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3155-034:20054.6 Cable stripping and wiring method A Fit the supplied guide ring on th

31、e cable. Insulation should be stripped back. Slide crimp ring over cable. Key 1 0,5 mm to 1 mm B Comb braid and fold back over crimp ring cut out fillers. Key 1 Blue core 2 White core C Strip conductors as shown. Key 1 Crimping D Position the blue conductor core in outer contact . Use tool M22520/2-

32、01 locator EN4008-009. 7 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3155-034:2005Key 1 Crimping E Feed the white conductor through the angled

33、 hole, fit insulator and position white conductor core in inner contact .Use tool M22520/2-01, locator M22520/2-37. F Fit split insulator around crimp buckets.Ensuring flange is positioned at front face of contact. G Insure central insulator, intermediate contact and outer insulator are located insi

34、de the body . Insert assembly into body. Key 1 Crimping H Crimp braid and outer jacket using tool M25520/5-01 and dies M22520/5-45 rep. B. Length of crimping: 6 mm. 8 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo re

35、production or networking permitted without license from IHS-,-,-prEN 3155-034:20054.7 Tooling 4.7.1 Crimping tools Conform to MIL-DTL-22520, see Table 2. These selector numbers given in Table 2 shall be used for qualification of the contacts and in service, unless otherwise specified by the user. Ta

36、ble 2 Contact Crimping tool Positioner Selector position Centre M22520/2-01 M22520/2-37 5 Intermediate M22520/2-01 EN4008-009 5 Outer M22520/5-01 M22520/5-45 B 4.7.2 Insertion/Extraction tools Conform to M81969/14-06. 4.8 Tests See Table 3. Table 3 Tests Applicable EN 2591- Designation of the test N

37、ot applicableAccording toEN 3155-001 Remarks 101 Visual examination X 102 Examination of dimensions and mass XX With cable code. 201 Contact resistance - low level Contact Maximum contact resistance m Initial After tests Centre 15 30 Intermediate 15 30 Outer Not applicable (continued) 9 Copyright As

38、sociation Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3155-034:2005Table 3 (continued) Applicable EN 2591- Designation of the test Not applicableAccording toEN 3155

39、-001 Remarks X With cable code. 202 Contact resistance at rated current Contact Maximum contact resistance m Rated current A (25 ) C 03+(150 ) C 03+Initial After testsAfter tests Centre 15 30 45 Intermediate 15 30 45 1 Outer 3 4 6 12 204 Discontinuity of contacts in the microsecond range X Method B.

40、Duration of discontinuity: 100 ns. Test duration: throughout the duration of tests EN 2591-402 and EN 2591-403. 206 Measurement of insulation resistance X Method C, mated contacts. Measurements between centre contact and intermediate and between intermediate contact and outer contact. At ambient tem

41、perature: 5 000 M At high temperature: 2 000 M at maximum specified temperature. 207 Voltage proof test X Method C.Withstand voltage at sea level: 1 000 V r.m.s. between centre contact and intermediate contact and 500 V r.m.s. between intermediate contact and outer contact. Withstand voltage at alti

42、tude: 125 V r.m.s. at a pressure of 4,7 kPa (21 000 m) Leakage current: 2 mA 212 Surface transfer impedance X 301 Endurance at temperature X Method B Duration : 1 000 h 305 Rapid change of temperature X TA= (150 2) C TB= ( 65 2) C 306 Mould growth X 307 Salt mist X (continued) 10 Copyright Associati

43、on Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3155-034:2005Table 3 (concluded) Applicable EN 2591- Designation of the test Not applicableAccording toEN 3155-001 Re

44、marks 315 Fluid resistance X See Table 4. According to EN 3682-001. 402 Shock X Method A, severity 300, see EN 3682-001, Figures 37, 38 and 39. 403 Sinusoidal and random vibration X According to EN 3682-001, Subclause 7.2.2. 406 Mechanical endurance X 417 Tensile strength X Cable according to TR 605

45、8 code XY (crimped connection) Contact Tensile valuesin N min. Centre 36 Intermediate 36 Outer 113 418 Gauge insertion/extraction forces (female contacts) X Intermediate contacts. Gauge as described in Figure 5 and Table 4. Minimum extraction force N Maximum insertion force N Gauge Initial After tes

46、t Initial After test maximum NA NA 8,34 10 minimum 0,83 0,69 NA NA 501 Soft solderability X 503 Contact deformation after crimping X Cable size in accordance with Table 1. Intermediate contact concentricity tolerance shall not exceed 0,28 mm. Intermediate contact and outer body. Crimping zone shall

47、not exceed 0,15 mm expansion. 508 Measurement of thickness of coating on contacts X The measured thickness shall be recorded. 509 Adhesion of coating on contacts X 513 Magnetic permeability X 11 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license w

48、ith AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3155-034:20054.9 Gauges Defined in Figure 5 and Table 4. Dimensions and tolerances are in millimetres. Figure 6 Table 4 Gauge A B C R L 2,896 2,3 1,5 0,71 7,5 max. 2,891 2,2 1,2 0,58 72,850 2,3 1,5 0,71 7,5 min. 2,845 2,2 1,2 0,58 75 Designation EXAMPLE Description block CONTACT ELECTRICAL Identity block EN3155-034M08AB Number of