AECMA PREN 3645-010-2005 Aerospace series Connectors electrical circular scoop-proof triple start threaded coupling operating temperature 175 degrees C or 200 degrees C continuous .pdf

上传人:diecharacter305 文档编号:420512 上传时间:2018-11-06 格式:PDF 页数:9 大小:426.30KB
下载 相关 举报
AECMA PREN 3645-010-2005 Aerospace series Connectors electrical circular scoop-proof triple start threaded coupling operating temperature 175 degrees C or 200 degrees C continuous .pdf_第1页
第1页 / 共9页
AECMA PREN 3645-010-2005 Aerospace series Connectors electrical circular scoop-proof triple start threaded coupling operating temperature 175 degrees C or 200 degrees C continuous .pdf_第2页
第2页 / 共9页
AECMA PREN 3645-010-2005 Aerospace series Connectors electrical circular scoop-proof triple start threaded coupling operating temperature 175 degrees C or 200 degrees C continuous .pdf_第3页
第3页 / 共9页
AECMA PREN 3645-010-2005 Aerospace series Connectors electrical circular scoop-proof triple start threaded coupling operating temperature 175 degrees C or 200 degrees C continuous .pdf_第4页
第4页 / 共9页
AECMA PREN 3645-010-2005 Aerospace series Connectors electrical circular scoop-proof triple start threaded coupling operating temperature 175 degrees C or 200 degrees C continuous .pdf_第5页
第5页 / 共9页
亲,该文档总共9页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、ASD STANDARD NORME ASD ASD NORM prEN 3645-010 Edition P1 November 2005 PUBLISHED BY THE AEROSPACE AND DEFENSE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Gulledelle 94 - B-1200 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 763 3565 - www.asd-stan.orgICS: 49.060 Descriptors: ENGLISH VERSION Ae

2、rospace series Connectors, electrical, circular, scoop-proof, triple start threaded coupling operating temperature 175 C or 200 C continuous Part 010: Receptacle, hermetic, round flange, jam nut mounting Product standard Srie arospatiale Connecteurs lectriques circulaires contacts protgs, accoupleme

3、nt par filetage pas rapide trois filets, tempratures dutilisation 175 C ou 200 C continu Partie 010 : Embase collerette ronde, hermtique fixation par crou Norme de produit Luft- und Raumfahrt Elektrische Rundsteckverbinder, kontaktgeschtzt, Drei-gangige Gewinde-Schnellkupplung Dauerbetriebstemperatu

4、ren 175 C oder 200 C Teil 010: Hermetischer Fester Steckverbinder mit runden Schwei und Mutternbefestigung Produktnorm This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The Aerospace and Defense Industries Association of Europe - Standardization). It is publ

5、ished for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this pre-standard, the technical content shall not be changed to an extent that interchangeability is affected,

6、physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European

7、Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 30 November 2005 Comments should be sent within six months af

8、ter the date of publication to ASD-STAN Electrical Domain Copyright 2005 by ASD-STAN Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 2 prEN 3645-0

9、10:2005 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. Contents Pa

10、ge 1 Scope. 3 2 Normative references 3 3 Terminology. 4 4 Required characteristics4 4.1 Dimensions, weights . 4 4.2 Materials and surface treatment 7 4.3 Recommended panel cut-out 7 4.4 Electrical, mechanical and climatic characteristics.7 5 Designation 8 6 Marking. 9 7 Technical specification. 9 Co

11、pyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 3 prEN 3645-010:2005 1 Scope This standard specifies the characteristics of hermetic receptacles wit

12、h jam nut mounting in the family of circular, electrical connectors, with triple start threaded coupling. It applies to models in table 3. For plugs and protective covers, see EN 3645-006, EN 3645-008, EN 3645-011 and EN 3645-012 respectively. The contacts are unremovable and soldered termination. T

13、hese connectors are derived from and interchangeable with Model Y in specification MIL-DTL-38999/23. 2 Normative references This European Standard incorporates by dated or undated reference provisions from other publications. These normative references are cited at the appropriate places in the text

14、 and the publications are listed hereafter. For dated and undated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referre

15、d to applies. EN 3645-001, Aerospace series Connectors electrical, circular, scoop-proof, triple start threaded coupling, operating temperature 175 C or 200 C continuous Part 001: Technical specification 1) EN 3645-002, Aerospace series Connectors electrical, circular, scoop-proof, triple start thre

16、aded coupling, operating temperature 175 C or 200 C continuous Part 002: Specification of performance and contact arrangements 1)EN 3645-006, Aerospace series - Connectors electrical, circular, scoop-proof, triple start threaded coupling, operating temperature 175 C or 200 C continuous - Part 006: P

17、rotective cover for receptacle - Product standard 1)EN 3645-008, Aerospace series - Connectors electrical, circular, scoop-proof, triple start threaded coupling, operating temperature 175 C or 200 C continuous - Part 008: Non release plug with grounding ring - Product standard 1)EN 3645-011, Aerospa

18、ce series - Connectors electrical, circular, scoop-proof, triple start threaded coupling, operating temperature 175 C or 200 C continuous - Part 011: Lanyard release plug with grounding fingers - Type 1 - Product standard 1)EN 3645-012, Aerospace series - Connectors electrical, circular, scoop-proof

19、, triple start threaded coupling, operating temperature 175 C or 200 C continuous - Part 012: Lanyard release plug with grounding fingers - Type 2 - Product standard 1)MIL-DTL-38999/23, Connectors, electrical, circular, miniature, high density, quick disconnect (bayonet, threaded and breech coupling

20、), environment resistant, removable crimp and hermetic solder contacts, receptacle, jam-nut mounting, hermetic, triple start threaded coupling, hermetic solder contacts, series III, metric 2) 1)Published as AECMA Prestandard at the date of publication of this standard 2)Published by: Department of D

21、efence (DOD), The Pentagon, Washington D.C. 20301 USA Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 4 prEN 3645-010:20053 Terminology See EN 364

22、5-001. 4 Required characteristics 4.1 Dimensions, weights Dimensions and tolerances are in millimetres. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,

23、-Page 5 prEN 3645-010:2005 (without seal) Seal (Slot with close edges) Key 1 Red strip 2 3 holes 1,5 min. for brake wire (see option according to Detail D) 3 H on flats 4 B on flat 5 Seal Figure 1 Hermetic jam nut receptacle Note: One disengagement is permissible to accept the accessory mounting. Co

24、pyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 6 prEN 3645-010:2005 Table 1 Hermetic jam nut receptacle - Dimensions A B C 1)D E F2)G H K max. Shel

25、l size 0,3 15,010,0+20,010,0+03,013,0+ 0,13 max. Thread Male contact Female contact 09 30,2 16,53 17,40 15,9 M17x1 6g 0,1 R 24,00 21,82 5,3 5,9 11 34,9 19,07 20,60 18,8 M20x1 6g 0,1 R 27,00 24,99 13 38,1 23,82 25,40 2,39 1,14 23,8 M25x1 6g 0,1 R 32,00 29,77 15 41,3 26,97 28,50 26,8 M28x1 6g 0,1 R 36

26、,00 32,91 17 44,5 30,15 31,85 30,8 M32x1 6g 0,1 R 3)37,00 36,12 5,1 5,7 19 49,2 33,32 34,90 33,8 M35x1 6g 0,1 R 41,00 39,25 21 52,4 36,50 37,903,58 1,91 36,8 M38x1 6g 0,1 R 46,00 42,47 23 55,6 39,67 41,20 39,8 M41x1 6g 0,1 R 50,00 45,61 25 58,7 42,85 44,40 42,8 M44x1 6g 0,1 R 51,23 49,25 L M N P S W

27、 X Y Z Mass (g) 03,0+ 0,13 1,04,0+ 0,4 1,07,0+max. Stainless steel 9,10 16,3 15,30 14,1 27,0 29,2 20,50 20,19 34 9,10 19,4 16,40 31,8 25,27 24,97 41 9,10 22,7 21,60 34,9 2,2 28,45 28,14 1,85 1,70 50 9,10 25,9 24,80 38,1 29,3 31,62 31,32 62 9,10 29,0 28,00 41,3 34,80 34,49 83 9,70 32,2 31,20 14,3 46,

28、0 37,92 37,62 108 9,70 35,4 34,30 49,2 3,0 30,1 41,20 40,69 2,69 2,54 141 9,70 38,6 37,50 52,4 44,37 43,86 172 9,70 41,7 40,70 55,6 47,55 47,04 203 1) Dimensions C and 1,5 mm shall be compatible with the panel hole 2) Diameter F corresponds to the start of the thread 3) Upper diameter modified as fo

29、llow: 31,95 max. 31,80 min. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 7 prEN 3645-010:2005 4.2 Materials and surface treatment See Table 3.

30、4.3 Recommended panel cut-out Dimensions and tolerances are in millimetres. Figure 2 Panel cut-out Table 2 - Panel cut-out - Dimensions Shell size A 025,0+B 25,00C min 09 17,70 16,99 31,80 11 20,88 19,53 35,00 13 25,58 24,26 39,40 15 28,80 27,53 42,50 17 31,98 30,68 45,70 19 35,15 33,86 48,50 21 38,

31、28 37,06 51,70 23 41,50 40,24 54,90 25 44,68 43,41 58,00 4.4 Electrical, mechanical and climatic characteristics See EN 3645-002. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted wi

32、thout license from IHS-,-,-Page 8 prEN 3645-010:20055 Designation EXAMPLE: Description block JAM NUT ELECTRICAL CONNECTOR Identity block EN3645-Y7GN35MA Number of the basic standard Model according to Table 3 Shell code for nut mounting receptacle Shell size code according to Table 4 only N: no grou

33、nded cavity Contact arrangement according to EN 3645-002 except those containing coaxial or triaxial contacts or size 10 contacts Contact code M: male with solder cup X: male with eyelet Polarisation: N, A, B, C, D, E NOTE: If necessary, the code I9005 shall be placed between the classification bloc

34、k and the identity block. Table 3 - Model coding Model Description Y Hermetic receptacles, with shell in stainless steel - Soldered contacts Maximum operating temperature 200 C continuous Table 4 - Shell size code Shell size Code 09 A 11 B 13 C 15 D 17 E 19 F 21 G 23 H 25 J Copyright Association Eur

35、opeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 9 prEN 3645-010:20056 Marking According to EN 3645-001. 7 Technical specification According to EN 3645-001. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文