AECMA PREN 4604-004-2006 Aerospace series Cable electrical for signal transmission Part 004 Cable microcoaxial high immunity 50 Ohms 200 Degrees C type WS Product standard Edition .pdf

上传人:towelfact221 文档编号:421486 上传时间:2018-11-06 格式:PDF 页数:10 大小:95.08KB
下载 相关 举报
AECMA PREN 4604-004-2006 Aerospace series Cable electrical for signal transmission Part 004 Cable microcoaxial high immunity 50 Ohms 200 Degrees C type WS Product standard Edition .pdf_第1页
第1页 / 共10页
AECMA PREN 4604-004-2006 Aerospace series Cable electrical for signal transmission Part 004 Cable microcoaxial high immunity 50 Ohms 200 Degrees C type WS Product standard Edition .pdf_第2页
第2页 / 共10页
AECMA PREN 4604-004-2006 Aerospace series Cable electrical for signal transmission Part 004 Cable microcoaxial high immunity 50 Ohms 200 Degrees C type WS Product standard Edition .pdf_第3页
第3页 / 共10页
AECMA PREN 4604-004-2006 Aerospace series Cable electrical for signal transmission Part 004 Cable microcoaxial high immunity 50 Ohms 200 Degrees C type WS Product standard Edition .pdf_第4页
第4页 / 共10页
AECMA PREN 4604-004-2006 Aerospace series Cable electrical for signal transmission Part 004 Cable microcoaxial high immunity 50 Ohms 200 Degrees C type WS Product standard Edition .pdf_第5页
第5页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、ASD STANDARD NORME ASD ASD NORM prEN 4604-004 Edition P 3 October 2006 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Gulledelle 94 - B-1200 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 763 3565 - www.asd-stan.orgICS: 49.060 Supersedes edition P 2 November

2、 2002 Descriptors: ENGLISH VERSION Aerospace series Cable, electrical, for signal transmission Part 004: Cable, microcoaxial, high immunity, 50 Ohms, 200 C, type WS Product standard Srie arospatiale Cbles lectriques pour transmission de signaux Partie 004 : Cble, microcoaxial, haute immunit, 50 Ohms

3、, 200 C, type WS Norme de produit Luft- und Raumfahrt Elektrisch Leitungen fr Signalbertragungen Teil 004: Microkoaxialkabel, 50 Ohm, 200 C, Typ WS Produktnorm This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association

4、 of Europe - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an exte

5、nt that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal v

6、ote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 31 October 2006 Comme

7、nts should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2006 by ASD-STAN Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without

8、 license from IHS-,-,-prEN 4604-004:2006 2 Contents Page Foreword2 1 Scope 3 2 Normative references 3 3 Terms and definitions .3 4 Required characteristics.3 5 Quality assurance9 6 Designation 9 7 Identification and marking . 10 8 Packaging, labelling and delivery lengths .10 9 Technical specificati

9、on 10 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. Copyright Ass

10、ociation Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 4604-004:2006 3 1 Scope This standard specifies the required characteristics, of a microcoaxial, 50 , type WS,

11、 for use in aircraft electrical systems at operating temperature between 55 C to 200 C, intended for radio-communications and especially for high frequency up to 3 GHz. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated referen

12、ces, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 3475-100*, Aerospace series Cables, electrical, aircraft use Test methods Part 100: General. EN 4604-001, Aerospace series Cable, electrical, for signal t

13、ransmission Part 001: Technical specification. EN 4604-002, Aerospace series Cable, electrical, for signal transmission Part 002: General. TR 6058, Aerospace series Cable code identification list. 1) ASTM B 298-99, Standard specification for silver-coated soft or annealed copper wire. 2) 3 Terms and

14、 definitions For the purposes of this document, the terms and definitions given in EN 3475-100 apply. 4 Required characteristics 4.1 Material, construction, dimensions and mass 4.1.1 Material See Table 1. Table 1 Material Finish Colour Conductor Multi strand core copper per ASTM-B298-99 1 m silver p

15、lated Dielectric Fluorocarbone Screen (foil) High permeability tape Shield Braid, copper per ASTM-B298-99 1 m silver plated Jacket 2 polyimide tapes Amber * And all parts quoted in Table 4. 1) Published as ASD Technical Report at the date of publication of this standard. 2) Published by: American So

16、ciety for Testing and Materials (ASTM), 1916 Race Street, Philadelphia, PA 19103, USA. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 4604-004:2

17、0064 4.1.2 Construction, dimensions and mass See Figure 1 and Table 2. Key 1 Conductor 2 Dielectric 3 Screen 4 Jacket 5 Shield Figure 1 Table 2 Dimensions and mass Diameter Mass mm g/m Conductor Dielectric Shield Cable nom. nom. min. max. min. max. max. 0,51 (7 0,16) mm 1,50 2,06 2,36 2,24 2,56 20 S

18、trands diameter for shield = 0,085 mm nominal. 4.2 General characteristics Operating temperature: 55 C to 200 C Minimum bend radius: in static use: 15 mm in dynamic use: 28 mm Performances are guaranteed up to 3 GHz. EN WS _ _ _ _45312Copyright Association Europeene des Constructeurs de Materiel Aer

19、ospatial Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 4604-004:20065 4.3 Electrical characteristics Characteristic impedance: Zc = (50 5) Capacitance per unit length: (95 10) pF/m Transfer impedance up to 100 MHz: 45

20、 m/m max. see Figure 4. Attenuation versus frequency: see Table 3 and Figure 2. Maximum power handling (at sea level): see Table 3 and Figure 3. Velocity of propagation: 0,69 c nom. Operating voltage: 1,3 kV RMS. Table 3 Frequency, attenuation and power handling Frequency MHz 50 100 200 400 1 000 3

21、000 Attenuation dB/100 m 26 36 55 78 140 195 Power handling W 600 400 270 180 120 75 Figure 2 Attenuation curve Attenuation WS cable 11010010000,01 0,1 1 10Frequency (GHz)Att. (db/100 m)Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMA

22、 Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 4604-004:20066 Figure 3 Power curve (W) Figure 4 Transfer impedance ZT 4.4 Tests See Table 4. Transfer impedance WS cable1,00E-021,00E-011,00E+001,00E+011,00E+021,00E+031,00E-01 1,00E+00 1,00E+01 1,00E+02 1,00E+

23、03 1,00E+04 1,00E+05Frequency (kHz)Zt (mohm/m)Power (W)1010010001,00E-02 1,00E-01 1,00E+00 1,00E+01Frequency (GHz)Power (W)Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without

24、license from IHS-,-,-prEN 4604-004:20067 Table 4 Tests EN 3475- Designation of the test Remarks 201 Visual examination Applicable 202 Mass Applicable 20 g/m max. 203 Dimensions Applicable See 4.1.2 and Table 2 301 Ohmic resistance per unit length Applicable 132 /km max. 302 Voltage proof test Applic

25、able Dielectric: Dry test: 1 500 V AC Jacket: Dry test: 1 750 V AC Dry impulse: 5 000 V 303 Insulation resistance Applicable 5 000 M.km between conductor and shield 304 Surface resistance Not applicable 305 Overload resistance Not applicable 306 Continuity of conductors Applicable 307 Corona extinct

26、ion voltage Not applicable 401 Accelerated ageing Not applicable 402 Shrinkage and delamination Not applicable 403 Delamination and blocking Not applicable 404 Thermal shock Not applicable 405 Bending at ambient temperature Not applicable 406 Cold bend test Not applicable 407 Flammability Applicable

27、 Load = 10 N 408 Fire resistance Not applicable 409 Air-excluded ageing Not applicable 410 Thermal endurance Not applicable 411 Resistance to fluids Applicable 412 Humidity resistance Not applicable 413 Wrap back test Not applicable 414 Differential scanning calorimeter (DSC test) Not applicable con

28、tinued Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 4604-004:20068 Table 4 Tests (continued) EN 3475- Designation of the test Remarks 415 Rapi

29、d change of temperature Applicable Variation of capacitance: 5 % max. Increase of attenuation: 5 % max. Shrinkage: 1,5 mm max. 1st Specimen length (C,): 20 m 416 Thermal stability Applicable Heat exposure temperature: 200 C Variation of capacitance: 5 % max. Increase of attenuation: 5 % max. Variati

30、on of impedance: 3 % max. Shrinkage: 1,5 mm max. 3rd Specimen length (C,): 20 m Mandrel diameter: 30 mm 501 Dynamic cut-through Not applicable 502 Notch propagation Applicable Cut depth 0,04 mm 503 Scrape abrasion Applicable Load: 6 N 504 Torsion Not applicable 505 Tensile test on conductors and str

31、ands Applicable Elongation: 10 % Tensile strength: 30 N. 506 Plating continuity Applicable 507 Adherence of plating Applicable 508 Plating thickness 1 m 509 Solderability Not applicable 510 Tensile strength and elongation of extruded insulation, sheath and jacket material Not applicable 511 Cable-to

32、-cable abrasion Not applicable 512 Flexure endurance Applicable Load: 10 N Mandrel diameter: 30 mm/100 cycles 513 Deformation resistance (Installation with plastic cable ties) Applicable Application force = 70 N 5 % 601 Smoke density Applicable 602 Toxicity Applicable 603 Resistance to wet arc track

33、ing Not applicable 604 Resistance to dry arc propagation Not applicable 605 Wet short circuit test Not applicable 701 Strippability and adherence of insulation to the conductor Applicable 10 N to 50 N continued Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS

34、 under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 4604-004:20069 Table 4 Tests (concluded) EN 3475- Designation of the test Remarks 702 Screen pushback capability Applicable 703 Permanence of manufacturers marking Applicable Except when

35、 marking on tape between shield and jacket 704 Flexibility Applicable 705 Contrast measurement Not applicable 706 Laser markability Not applicable 801 Capacitance per unit length C = (95 10) pF/m at 1 kHz 802 Capacitance unbalance Not applicable 803 Capacitance variation Not applicable 804 Velocity

36、of propagation Applicable v: 207 000 km/s 805 Characteristic impedance Applicable Zc = (50 5) at 200 MHz 806 Attenuation Applicable See 4.3. Table 3 and Figure 2. 807 Transfer impedance Applicable See 4.3 and Figure 4. 45 m/m up to 100 MHz 808 Cross-talk Not applicable 5 Quality assurance See EN 460

37、1-001. 6 Designation EXAMPLE Description block CABLE, MICROCOAXIAL Identity block EN4604-004WS Number of this standard Cable code (see TR 6058, Table 28) NOTE If necessary, the code I9005 shall be placed between the description block and the identity block. Copyright Association Europeene des Constr

38、ucteurs de Materiel Aerospatial Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 4604-004:200610 7 Identification and marking Colour of the marking shall be black. See EN 4604-002. 8 Packaging, labelling and delivery len

39、gths 8.1 Packaging and labelling See EN 4604-001. 8.2 Delivery lengths Delivery on cable drum (about 200 metres) Minimum length of each piece: 50 metres. 9 Technical specification See EN 4604-001. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-