AHRI 730 I-P-2013 Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers.pdf

上传人:deputyduring120 文档编号:422571 上传时间:2018-11-06 格式:PDF 页数:8 大小:220.24KB
下载 相关 举报
AHRI 730 I-P-2013 Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers.pdf_第1页
第1页 / 共8页
AHRI 730 I-P-2013 Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers.pdf_第2页
第2页 / 共8页
AHRI 730 I-P-2013 Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers.pdf_第3页
第3页 / 共8页
AHRI 730 I-P-2013 Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers.pdf_第4页
第4页 / 共8页
AHRI 730 I-P-2013 Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 2013 Standard for Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers AHRI Standard 730 (I-P) Price $15.00 (M) $30.00 (NM) Copyright 2013, by Air-Conditioning, Heating and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORTAN

2、T SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, ass

3、embled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does

4、 not certify or guarantee that any tests conducted under the standards/guidelines will not be non-hazardous or free from risk. Note: This standard supersedes AHRI Standard 730-2005. For SI ratings, see AHRI Standard 731 (SI)-2013. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose . 1 Section 2. Scop

5、e 1 Section 3. Definitions 1 Section 4. Test Requirements . 2 Section 5. Rating Requirements 2 Section 6. Minimum Data Requirements for Published Ratings 3 Section 7. Marking and Nameplate Data 3 Section 8. Conformance Conditions . 4 TABLES Table 1. Standard Rating Conditions for R-22, R-290, R-404A

6、, R-407C, R-410A, R-407A and R-507A 2 Table 2. Standard Rating Conditions for R-134a and R-600a . 2 Table 3. Standard Rating Conditions for R-744 3 Table 4. Recommended Pressure Drop Values for Rating and Selection of Suction Line Filters and Suction Line Filter Driers 3 APPENDICES Appendix A. Refer

7、ences - Normative . 5 Appendix B. References - Informative 5 AHRI STANDARD 730 (I-P)-2013 1 FLOW CAPACITY RATING OF SUCTION LINE FILTERS AND SUCTION LINE FILTER DRIERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish, for refrigerant Suction Line Filters and Suction Line

8、Filter Driers (which may be referred to herein as “filters“): definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, includ

9、ing manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to Suction Line Filters and Suction Line Filter Driers, as defined in Section 3. 2.2

10、 Refrigerant. This standard applies to Suction Line Filters and Suction Line Filter Driers for use in systems employing refrigerants, R-22, R-134a, R-290, R-404A, R-407A, R-407C, R-410A, R-507A, R-600a, and R-744 as defined in ANSI/ASHRAE 34 with Addenda. Section 3. Definitions All terms in this doc

11、ument will follow the standard industry definitions in the ASHRAE Wikipedia website (http:/wiki.ashrae.org/index.php/ASHRAEwiki) unless otherwise defined in this section. 3.1 Permanent Installation. An installation intended to remain in the system for an indefinite period. 3.2 Published Rating. A st

12、atement of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating inclu

13、des the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.2.1 Application Rating. A rating based on tests performed at application Rating Conditions (other than St

14、andard Rating Conditions). 3.2.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.3 Rating Conditions. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.3.1 Standard Rating

15、Conditions. Rating conditions used as the basis of comparison for performance characteristics. 3.4 Refrigerant Flow Capacity. The maximum capacity of a filter drier attained at specified conditions as mentioned in ANSI/AHRI Standard 710, and 1 psi change in pressure, expressed in tons. 3.4.1 Pressur

16、e Drop. The pressure difference between the inlet and outlet of a filter, including its connections expressed in psi. 3.5 “Shall“ or “Should“. “Shall“ or “should“ shall be interpreted as follows: AHRI STANDARD 730 (I-P)-2013 2 3.5.1 Shall. Where “shall“ or “shall not“ is used for a provision specifi

17、ed, that provision is mandatory if compliance with the standard is claimed. 3.5.2 Should. “Should“ is used to indicate provisions which are not mandatory, but which are desirable as good practice. 3.6 Suction Line Filter. A manufactured device used in the suction line of a refrigeration system, for

18、the purpose of removing and retaining solid contaminants from the refrigerant. 3.7 Suction Line Filter Drier. A manufactured device used in the suction line of a refrigeration system, whose element is partly or wholly composed of a desiccant. It is intended to remove and retain moisture as well as s

19、olid contaminants from the refrigerant. 3.8 Temporary Installation. An installation intended to remain in the system for a short period of time with the purpose of cleaning a new or severely contaminated system. Section 4. Test Requirements 4.1 Test Requirements. All filter and filter-drier capacity

20、 ratings shall be based on tests in accordance with, or subject to verification by, the test procedure of ANSI/ASHRAE Standard 78. 4.1.1 If the filter capacity depends upon the position of or direction of flow through the filter, the filter shall be tested for all variations for which ratings are pu

21、blished. Section 5. Rating Requirements 5.1 Published Ratings. As used herein, the term Published Ratings includes the ratings shown on the filter or published in specifications, advertising or other literature controlled by the manufacturer at stated Rating Conditions. Published Ratings shall inclu

22、de Standard Ratings, and may also include Application Ratings (See Table 4). 5.2 Standard Ratings. Standard capacity ratings of filters for refrigerant suction-line service shall be stated in tons and/or mass flow rate, lb/h. The following specified conditions shall be used to determine the refriger

23、ant flow rate through the filter. 5.2.1 Standard Rating Conditions. Standard Rating Conditions shall be according to Table 1, Table 2, and Table 3 below: Table 1. Standard Rating Conditions for R-22, R-290, R-404A, R407C, R-410-A, R407A and R-507A Evaporator Saturation Temperature 40F Vapor Temperat

24、ure Leaving Evaporator 50F Vapor Temperature Entering Filter 65F Liquid Temperature Entering Expansion Device 90F Pressure Drop 3.0 psi Table 2. Standard Rating Conditions for R-134a and R-600a Evaporator Saturation Temperature 40F Vapor Temperature Leaving Evaporator 50F Vapor Temperature Entering

25、Filter 65F Liquid Temperature Entering Expansion Device 90F Pressure Drop 2.0 psi AHRI STANDARD 730 (I-P)-2013 3 Table 3. Standard Rating Conditions for R-744 Evaporator Saturation Temperature -20F Vapor Temperature Leaving Evaporator -10F Vapor Temperature Entering Filter 5F Liquid Temperature Ente

26、ring Expansion Device 20F Pressure Drop 4.0 psi 5.2.2 Application Rating Conditions. In addition to AHRI standard capacity ratings at the conditions specified in Section 5.2.1, capacity ratings may also be published for other evaporator temperatures or pressure drop values, provided they are specifi

27、ed as such and are based on all the other provisions of this section (See Table 4). 5.3 Tolerances. To comply with this standard, published capacity ratings shall be based on the requirements of this section, and shall be such that any production Suction Line Filters and Suction Line Filter Driers s

28、elected at random and tested shall have a capacity not less than 95% of its Standard Rating. Table 4. Recommended Pressure Drop Values for Rating and Selection of Suction Line Filters and Suction Line Filter Driers1 Evaporator Saturated Suction Temperature Permanent Installations Temporary Installat

29、ions R-22, R-290, R-404A, R-407A, R-407C, R-410A, and R-507A R-134a and R-600a R-744 R-22, R-290, R-404A, R-407A, R-407C, R-410A, and R-507A R-134a and R-600a R-744 F psi psi psi psi psi psi 4023.0 2.02N/A 8.0 6.0 N/A 20 2.0 1.5 6.0 4.0 3.0 12 0 1.5 1.0 5.0 3.0 2.0 10 -2031.030.534.0 2.0 1.0 8.0 -40

30、 0.5 N/A 3.0 1.0 N/A 6.0 Notes: 1. These pressure drop values also represent recommended maximum pressure drop values for selections of filters for Permanent and Temporary Installations 2. AHRI Standard Rating Conditions excluding R-744, Permanent Installations only. 3. AHRI Standard Rating Conditio

31、ns for R-744, Permanent Installations only. Section 6. Minimum Data Requirements for Published Ratings 6.1 Minimum Data Requirements for Published Ratings. As a minimum, Published Ratings shall include all Standard Ratings. All claims to ratings within the scope of this standard shall include the st

32、atement “Rated in accordance with AHRI Standard 730 (I-P)“. All claims to ratings outside the scope of this standard shall include the statement “Outside the scope of AHRI Standard 730 (I-P)”. Wherever Application Ratings are published or printed, they shall include a statement of the conditions at

33、which the ratings apply. Section 7. Marking and Nameplate Data 7.1 As a minimum, the nameplate shall display the manufacturers name and model designation. AHRI STANDARD 730 (I-P)-2013 4 Section 8. Conformance Conditions 8.1 Conformance. While conformance with this standard is voluntary, conformance

34、shall not be claimed or implied for products or equipment within the standards Purpose (Section 1) and Scope (Section 2) unless such product claims meet all of the requirements of the standard and all of the testing and rating requirements are measured and reported in complete compliance with the st

35、andard. Any product that has not met all the requirements of the standard shall not reference, state, or acknowledge the standard in any written, oral, or electronic communication. AHRI STANDARD 730 (I-P)-2013 5 APPENDIX A. REFERENCES - NORMATIVE A1 Listed here are all standards, handbooks and other

36、 publications essential to the formation and implementation of the standard. All references in this appendix are considered as part of the standard. A1.1 ANSI/AHRI Standard 710-2009, Performance Rating of Liquid-Line Driers, 2009, American National Standards Institute/Air-Conditioning Heating & Refr

37、igeration Institute, 2111 Wilson Blvd., Suite 500, Arlington, VA 22201, U.S.A. A1.2 ANSI/ASHRAE Standard 34-2010 with Addenda, Designation and Safety Classification of Refrigerants, 2010, American National Standards Institute/American Society of Heating, Refrigerating and Air-Conditioning Engineers,

38、 Inc., West 43rdStreet, 4thFloor, New York, NY 10036, U.S.A./1791 Tullie Circle N.E., Atlanta, GA 30329, U.S.A. A1.3 ANSI/ASHRAE Standard 78-1985 (RA 2007), Method of Testing Flow Capacity of Suction Line Filters and Filter Driers, 2007, American National Standards Institute/American Society of Heat

39、ing, Refrigerating and Air-Conditioning Engineers, Inc., West 43rdStreet, 4thFloor, New York, NY 10036, U.S.A./1791 Tullie Circle N.E., Atlanta, GA 30329, U.S.A. A1.4 ASHRAEwiki, Terminology. American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc, Web. 21 Sept. 2012 APPENDIX B. REFERENCES INFORMATIVE None.

展开阅读全文
相关资源
猜你喜欢
  • BS PD CEN TR 15640-2007 Health informatics — nMeasures for ensuring nthe patient safety of nhealth software《医疗信息学 确保病人安全的医疗软件的测量》.pdf BS PD CEN TR 15640-2007 Health informatics — nMeasures for ensuring nthe patient safety of nhealth software《医疗信息学 确保病人安全的医疗软件的测量》.pdf
  • BS PD CEN TR 15642-2011 Unified tests procedures for the tests of EN 3-7-2004+A1-2007《EN 3-7-2004+A1-2007试验的统一试验规程》.pdf BS PD CEN TR 15642-2011 Unified tests procedures for the tests of EN 3-7-2004+A1-2007《EN 3-7-2004+A1-2007试验的统一试验规程》.pdf
  • BS PD CEN TR 15645-1-2008 Paper and board nintended to come ninto contact with nfoodstuffs — nCalibration of the nodour test — n nPart 1 Odour n《与食品接触的纸和纸板 气味试验的校准 第1部分 气.pdf BS PD CEN TR 15645-1-2008 Paper and board nintended to come ninto contact with nfoodstuffs — nCalibration of the nodour test — n nPart 1 Odour n《与食品接触的纸和纸板 气味试验的校准 第1部分 气.pdf
  • BS PD CEN TR 15678-2008 Concrete — Release of nregulated dangerous nsubstances into soil ngroundwater and nsurface water — Test nmethod for new or nunapproved nconstituen.pdf BS PD CEN TR 15678-2008 Concrete — Release of nregulated dangerous nsubstances into soil ngroundwater and nsurface water — Test nmethod for new or nunapproved nconstituen.pdf
  • BS PD CEN TR 15697-2008 Cement — Performance ntesting for sulfate nresistance — State of nthe art report《水泥 硫酸盐腐蚀耐受性的性能试验 当前的工艺水平报告》.pdf BS PD CEN TR 15697-2008 Cement — Performance ntesting for sulfate nresistance — State of nthe art report《水泥 硫酸盐腐蚀耐受性的性能试验 当前的工艺水平报告》.pdf
  • BS PD CEN TR 15709-2008 Hardware for nfurniture — Terms for nslide fittings for sliding ndoors and roll fronts《家具五金件 滑门和卷门滑动配件的术语》.pdf BS PD CEN TR 15709-2008 Hardware for nfurniture — Terms for nslide fittings for sliding ndoors and roll fronts《家具五金件 滑门和卷门滑动配件的术语》.pdf
  • BS PD CEN TR 15716-2008 Solid recovered fuels n— Determination of ncombustion behaviour《固体再生燃料 燃烧特性的测定》.pdf BS PD CEN TR 15716-2008 Solid recovered fuels n— Determination of ncombustion behaviour《固体再生燃料 燃烧特性的测定》.pdf
  • BS PD CEN TR 15728-2016 Design and use of inserts for lifting and handling of precast concrete elements《预制混凝土提升和运输用嵌入件的设计和使用 组件》.pdf BS PD CEN TR 15728-2016 Design and use of inserts for lifting and handling of precast concrete elements《预制混凝土提升和运输用嵌入件的设计和使用 组件》.pdf
  • BS PD CEN TR 15729-2010 Plastics piping systems — nGlass-reinforced thermosetting nplastics (GRP) based on nunsaturated polyester nresin (UP) — Report on the determination.pdf BS PD CEN TR 15729-2010 Plastics piping systems — nGlass-reinforced thermosetting nplastics (GRP) based on nunsaturated polyester nresin (UP) — Report on the determination.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1