1、A-A- 50 7 2 9 15 December 1987 COMMERCIAL ITEM DESCRIPTION METER, MULTIPLE SCALE The General Services Administration has authorized the use of this Commercial Item Description. Scope. This Commercial Item Description (CID), describes a meter, multiple scale, with battery pack, 10 MHz to 18 GHz. This
2、 CID is meant as a minimum requirement .for the meter in whichonly those manufacturers that meet or sur- pass the following requirements are qualified per this CID. Classification. equipment modified to the extent necessary to meet the following description. The equipment shall be type III, class 5,
3、 style E and color R in accordance with the latest MIL-T-28800. testing in accordance with the latest MIL-T-28800. Equipment covered by this CID may be commercially available This CID makes provision for the bid sample Applic.able documents . ., Specifications and standards. The following specificat
4、ions and standards Unless otherwise form a part of this CID to the extent specified herein. specified, the issues of these documents shall be those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the soiicitation. SPECI
5、FICATIONS MILITARY MIL-T-28800 Test Equipment for usewi-h Electrical and Electronic Equipment, General Specification for (the latest edition). STANDARDS MILITARY MIL-STD-461 Electromagnetic Emission and Susceptibility Require- ments for the Control of Electromagnetic Interface. (Copies of specificat
6、ions and standards, and other Government documents required by contractors in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting activity.) -. a AMSC NIA FSC 6625 DISTRIBUTION STATEMENT A. .Approved for public release; di
7、stribution is unlimited. f . THIS DOCUMENT CONTAINS $ PAGES. . Licensed by Information Handling ServicesA-A- 50 72 9 Other publications. extent specified herein, Unless otherwise specified, the issue of the docu- ments which are DOD adopted shall be those listed in the issue of the DODISS specified
8、in the solicitation, Unless otherwise specified, the issues of documents not listed in the DODISS shall be the issue of the nongovernment documents which is current on the date of the solicitation, The following document forms a part of this CID to the INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEE
9、RS IEEE 587-1980 (Application for copies of IEEE publications should be addressed to the Institute of Electrical and Electronics Engineers, West 47th Street, New York, NY 10018) Order of precedence, In the event of a conflict between the text of this CID and the references cited herein (except for a
10、ssociated detail specifications, specification sheets or MS standards) the text of this CID shall take prece- dence. Nothing in this CID, however, shall supersede applicable laws and regulations unless a specific exemption has been obtained, Salient characteristics , the accuracies, limits, and spec
11、ifications herein, The equipment shall be capable of operation within a. b. c. 1, Safety, The equipment shall be UL (Underwriters Laboratories) listed and approved and/or shall comply with the type III safety requirements of the latest MIL-T-28800. Leakage currerlt .ptotection. leakage current in ex
12、cess of 3.5 milliamperes (ma) ras (AC and DC) Protection shall be provided from from any accessible conductive parts of equipment (including control shafts with knobs broken or removed and recessed calibration or adjustment controls) to either pole of the power source for any posi- tion of the power
13、 switch(es) , Radio frequency interference (RFI).capacitors. Any capacitor used in RFI filters shall be rated for at least four(4) times the operating voltage. Type IIL ventilation openings, (1) contact with live electrical circuits and mechanical moving parts e Ventilation openings shall be designe
14、d to prevent accidental (2) Top ventilation openings shall incorporate small mesh- screening or similar design to prevent the expulsion of hot electronic par- ticles du.e to failure of electronic devices such as capacitors, 2, Parta, materials, and processes. Except for marking, the meter shall comp
15、ly with the type III parts, materials, and process requirements of MIL-T-28800, the latest MIL-T-28800, latest MIL-T-28800, . Nonstandard parts approval requests shall be in accordance with Front panel marking shall be in accordance with the Licensed by Information Handling ServicesA-A-50727 bb m 77
16、99774 0030276 m A-A- 50729 a. Restricted material. The equipment shall comply with the restricted material requirements of the latest MIL-T-28800, including the requirement for mercury and radioactive materials, and shall contain no combination of materials which cause deterioration of any material
17、contained in the equipment due to the effects of outgassing. 3. DESIGN AND CONSTRUCTION. Unless otherwise specified herein, the equip- ment shall comply with the type III design and construction requirements of the latest MIL-T-28800. Encapsulation and embedment (potting) of subassemblies may be use
18、d only for high voltage circuits where construction is susceptible to leakage or corona, indicators and associated controls shall be in close proximity to each other, all potentiometer controls shall have at least a 270 degree rotation range (4.71 radians). The- equipment shall be of solid-state -co
19、nstruction. a. Type of construction. monolithic design. Construction of the power meter s.hall be of a b. Signal input and output connectors. Unless otherwise specified, all signal input and output connectors shall be type BNC female. C. Internal cooling. tinuously for twenty four(24) hours at 55C.
20、it shall be as specified in MIL-T-28800. The equipment shall be capable of operating con- If forced air is used, (1) Forced air cooling motor. for the forced air cooling motor in the equipment. DC brushless motors shall be utilized (2) Air filter. Equipment utilizing a cooling scheme which exhausts
21、air from the equipment through the cooling fan shall not require an externally accescible air filter. (3) interrupt circuit power to the meter when the internal temperature rises to the degree of possible damage to the electronic components. A minimm of 10C hysteresis drop from this tripping tempera
22、ture must occur before circuit power is again applied. Thermal switch. A thermal switch shall be provided which will 4. The equipment shall operate from nominal com- mercial, military, and shipboard power sources of 115/230 volts ac (+lo%) at line frequencies of 50 Hz to 400 Hz. Electrical power sou
23、rces. - a. Electrical power connectors. The equipment shall operate with a ground at the primary source on either side of the single phase input. be Power consumption. Maximum power consumption shall not exceed 20 watts. Fuses. C. - replacement without entering the enclosure. The fuse(s) shall auto-
24、 matically disconnect t.he equipment from the power source in the event of excessive current requirements. Fuse(s) shall be provided, on the exterior rear panel for Licensed by Information Handling ServicesA-A-50727 bb m 999977q 0010277 T A-A-50729 d. Surge and transient voltage protection, The mete
25、r shall contain surge and transient voltage protection internal of the enclosure, The transient voltage protection circuit shall be so designed as to prevent electronic device damage within the system per type III solid state tolerance bands of MIL-T-28800, the surge voltage protection circuit shall
26、 conform to IEEE 587-1980. The surge protection circuit shall drain excess power due to surges directly to the ground conductor for personnel protection. inhibited and false operational signals may be generated under input voltage transients greater than 3.20 percent and frequency transient conditio
27、ns greater than 3.5 perce% from within the nominal type III steady-state tolerance bands of MIL-T-28800, damage (other than fuse failure) to the meter shall not occur during voltage transient conditions greater than +20 percent and frequency transient conditions greater than +5 percent Within the ma
28、ximum limits (30 percent voltage transients and 10 percent frequency transients) specified in MIL-T-28800 Normal operation of the meter shall be automatically resumed when the transient has passed and any blown fuses are replaced, shall be externally accessible, Normal operation of the meter may be
29、Blown fuses Testing shall be in accordance with MIL-T-28800. 5, consistent with current commercial capabilities, refer to paragraphs 5,a and Dimensions and weight. The size and weight of the equipment shall be 5.b of this CID. a. Equipment dimensions, The nominal dimensions for the meter sbould be a
30、pproximately 8 inches height a 8 inches wide x 12 inches deep, - b, Equipment weight, The weight including all accessories (excluding manual) shall not exceed 10 lbs. 6, Enclosure requirements, Unless otherwise specified herein, the equip- ment shall comply with the style E enclosure requirements of
31、 MIL-T-28800 , a, Rackmount, the equipment specified herein. Tilt bail handle. the hinged metal handles in accordance with MIL-T-28800, to this paragraph may be acceptable as this is not a prime can- sideration of the equipment. Rackmount capability shall be available as an option for b, A tilt-gai1
32、 handle shall be provided in lieu of Exception c, Reusable pouch orcontaider, for storage of all supplied accessories in lieu of front-couer storage, An attached accessory pouch may be used 7, Marking and identification. a, Marking. variable cont;rols, indicators, jacks, connectors and fuse holder(s
33、), shall be marked with a suitable word, phrase, or abbreviation thereof, indicating the purpose or use of the part, The visible surface adjacent to panel facilities such as Licensed by Information Handling ServicesA-A-50729 66 W 777971Li 0030278 L W A-A- 50729 (1) Panel marking. type III parts, mat
34、erials and processes panel marking requirements of MIL-T-28800; however, marking identification processes other than the type III requirements specified in MIL-T-28800 may be used, provided the marking and identification processes are capable of passing the front panel marking test when tested in ac
35、cordance with this CID. The front panel marking shall comply with the b. Items to be marked. (1) three external surfaces of the enclosure. Volume and weight (including accessories) shall be marked on (2) be stenciled on the exterior or main frame on at least three adjacent surfaces, on the transient
36、 case on two opposite sides. Marking shall be in block letters approximately 2 inches in height. The type designation of the AN nomenclature of the meter shall 8. Environmental requirements. a. bo C. d. e. .Temperature requirements. Unless otherwise specified herein, the equipment shall meet its spe
37、cified performance characteristics and other requirements when subjected to the class 5 temperature require- ments specified by MIL-T-28800 and as listed below. (1) Non-operatinv temperature. The equipment shall meet its perform- ance and accuracy requirements in an non-operating environment of -4OO
38、C to +75C. (2) Operating temperature. The equipment shall meet its performance and accuracy requirements in an operating environment of OC to 50C. Humidity requirements. ance and accuracy requirements under humidity requirements for class 5 equipment as specified by MIL-T-28800. Altitude requirement
39、s. ance and accuracy requirements under the altitude requirements for class 5 equipment as specified by MIL-T-28800. Vibration requirements. vibration requirements as specified by MIL-T-28800. Mechanical shock requirements. (1) requirement as specified by MIL-T-28800. (2) Transit drop. The equipment
40、 shall meet transit drop requirement as specified by MIL-T-28800. The equipment shall meet its required perform- The equipment shall meet its required perform- The equipment shall meet the class 5 Shock, pulse. The equipment shall meet the class 5 shock, pulse (3) Bench handling. The equipment shall
41、 meet the requirements as specified by MIL-T-28800. 5 Licensed by Information Handling ServicesA-A- 50729 (4) Shock, high impact. The equipment shall meet the requirements as specified by MIL-T-28800. f . Electromagnetic interference (EMI). The equipment shall comply with the following EM1 requireme
42、nts specified in MIL-STD-461: (1) (3301: Narrow band requirement from 1OldIz to 20kHz only. (2) CS03: Full limits. (3) CSOl: Full limits. (4) CS02: Full limits. (5) CS06: Full limits. (6) mol: Relaxed 10dB at the fundamental, 3rd harmonic, and 5th harmonic of the source power frequency with the meas
43、urement probe located 12 inches from device under test. (7) RE02: Full limits to 10 times the highest used or intentionally generated Erequency, or lGHz, whichever is greater. (8) RSO1: Full limits (9) RS03: Full limits to 1GHz. g. Magnetic environment. The equipment shall comply with the magnetic e
44、nvironment requirements of MIL-T-28800. 9. Reliability. Reliability verification testing, shall be in accordance with the type III, class 5 environmental conditions of MIL-T-28800. Mean time between failures (MTBF). failures (MTBF) shall be 2,000 hours. The equipment mean time between Pre-conditioni
45、ng requirement. sublected to the environmental screening effects of burn-in and ther- Each deliverable equipment shall be mal“ cycling, with thermal cycling being-also accomplished in the sample testing phase. (1) BURN-IN. Burn-in shall expose the equipment to extended periods of elevated temperatur
46、es, (43C for a minimum of 96 hours). equipment which fails during burn-in shall be repaired and fully retested, until failure free. in teet shall be noted and reported but shall not count toward the establiehment of MTBF. Prior to and following burn-in, a satisfac- tory operation test (SOT) shall be
47、 performed. tion check (SOC) shall be performed conducted at selected times during the burn-in test. (2) Thermal cycling. Thermal cycling shall expose the equipment to hot andscold cycles for claes 5 equipment per MIL-T-28800. equipment which fails during thermal cycling shall be repaired and full c
48、ycling test shall be noted and reported but shall not count toward the cycling, a satisfactory operation check (SOC) shall be conducted during the last two upper and lower temperature limits. Each Failures which occur during the burn- A satisfactory opera- Each 6 Licensed by Information Handling Ser
49、vicesA-A-50729 66 9999974 OOLO2BO T A-A- 50729 10. provide for readily accessible calibration adjustments and maintenance adjustments. ponents which are adjustable by the use of .simple means. The calibration by substitution of selected components or parts is unacceptable unless specifi- cally approved. The calibration adjustments, wherever possible, shall be accessible without removal of the instrument case or modules. Calibration and maintenance adjustments. The design of the system shall 0 These adjustments shall be provided by variable value com- a. Maintainability. The equipmen