AIR FORCE A-A-58086 A-2004 TRUCK LIFT FORK ELECTRIC SIT-DOWN SOLID TIRES 3 000 POUND CAPACITY AT 24 INCH LOAD CENTER 185 INCH MINIMUM LIFT《24英寸负荷中心的185英寸最低扬程3000磅承受力固体轮胎电动降落起重叉车》.pdf

上传人:tireattitude366 文档编号:427017 上传时间:2018-11-07 格式:PDF 页数:8 大小:39.13KB
下载 相关 举报
AIR FORCE A-A-58086 A-2004 TRUCK LIFT FORK ELECTRIC SIT-DOWN SOLID TIRES 3 000 POUND CAPACITY AT 24 INCH LOAD CENTER 185 INCH MINIMUM LIFT《24英寸负荷中心的185英寸最低扬程3000磅承受力固体轮胎电动降落起重叉车》.pdf_第1页
第1页 / 共8页
AIR FORCE A-A-58086 A-2004 TRUCK LIFT FORK ELECTRIC SIT-DOWN SOLID TIRES 3 000 POUND CAPACITY AT 24 INCH LOAD CENTER 185 INCH MINIMUM LIFT《24英寸负荷中心的185英寸最低扬程3000磅承受力固体轮胎电动降落起重叉车》.pdf_第2页
第2页 / 共8页
AIR FORCE A-A-58086 A-2004 TRUCK LIFT FORK ELECTRIC SIT-DOWN SOLID TIRES 3 000 POUND CAPACITY AT 24 INCH LOAD CENTER 185 INCH MINIMUM LIFT《24英寸负荷中心的185英寸最低扬程3000磅承受力固体轮胎电动降落起重叉车》.pdf_第3页
第3页 / 共8页
AIR FORCE A-A-58086 A-2004 TRUCK LIFT FORK ELECTRIC SIT-DOWN SOLID TIRES 3 000 POUND CAPACITY AT 24 INCH LOAD CENTER 185 INCH MINIMUM LIFT《24英寸负荷中心的185英寸最低扬程3000磅承受力固体轮胎电动降落起重叉车》.pdf_第4页
第4页 / 共8页
AIR FORCE A-A-58086 A-2004 TRUCK LIFT FORK ELECTRIC SIT-DOWN SOLID TIRES 3 000 POUND CAPACITY AT 24 INCH LOAD CENTER 185 INCH MINIMUM LIFT《24英寸负荷中心的185英寸最低扬程3000磅承受力固体轮胎电动降落起重叉车》.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Comments, suggestions, or questions on this document should be addressed to WR-ALC/LEEV, 295 Byron St., Warner Robins AFB, GA 31098-1611 or emailed to robert.davidrobins.af.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Onl

2、ine database at http:/assist.daps.dla.mil . FSC 3930 A-A-58086A 25 December 2004 SUPERSEDING A-A-58086 29 November 1996 COMMERCIAL ITEM DESCRIPTION TRUCK, LIFT, FORK, ELECTRIC, SIT-DOWN, SOLID TIRES 3,000 POUND CAPACITY AT 24 INCH LOAD CENTER, 185 INCH MINIMUM LIFT The General Services Administratio

3、n has authorized the use of this Commercial Item Description (CID) for all federal agencies. 1. SCOPE. 1.1 Scope. This commercial item description covers the general requirements for an electrical, industrial type, forklift truck. It will be capable of handling cargo in and around warehouses, loadin

4、g platforms and docks; on paved or other hard surfaces. 2. CLASSIFICATION. 2.1 Classification. The operator driven vehicle covered by this CID shall be commercially available and may be modified to the extent necessary to meet this description. 3. SALIENT CHARACTERISTICS. 3.1 Safety. The operator dr

5、iven vehicle shall be capable of operation within the accuracies, limits, and specifications herein. The forklift shall comply with ANSI B56.1, OSHA standards, and UL 583, Type E, and all other applicable standards in effect at the time of manufacture. A mounted fire extinguisher shall be provided.

6、A seatbelt conforming to SAE J386, and restraint devices designed to ensure the operators upper body remains entirely within the protection of the overhead guard in the event of tip-over shall be provided. Unless otherwise specified (see 7.3), the final color shall be yellow for safe operation in an

7、 indoor environment. INCH POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-58086A 23.2 Environmental requirements. The forklift shall be capable of continuous operation as specified herein at any ambient temperature from 0 degrees F to 120 d

8、egrees F. The truck with Type C winterization shall be capable of operating in temperatures ranging from -25 degrees F to +125 degrees F. 3.3 Maintainability. All maintenance and serving functions shall be capable of being performed using common hand tools. 3.4 Lubrication. Lubrication means shall b

9、e provided for all moving parts that require periodic lubrication. The types of lubricants shall be selected from and in accordance with SAE J754. Grease lubrication fittings shall conform to SAE J534. 3.5 Fluid level indicator. All fluid level indicators shall be located where they are accessible w

10、ithout danger of burns or injury to the operator. The indicators shall be in an open area, or covered by a hinged panel that can be opened and closed without the need for tools. 3.6 Hydraulic System. A pressure relief protection device is required along with pump(s), cylinders, control valves, filte

11、r(s), reservoir, hoses, and all other components necessary to make a complete hydraulic system(s) 3.7 Electric motors. Motors shall be industrial type. The insulation for motors shall be Class B, F, or H as defined in NEMA standards. 3.8 Battery. The battery shall be 24, 36, or 48 volts. The battery

12、 shall have adequate capacity to provide not less than 8.0 hours of continuous operation under normal industrial use. The battery mounted half connector shall be equipped with “SB” locking half connectors. When specified (see 7.3), the truck shall be shipped with the following items: Additional batt

13、ery and/or battery charger. 3.9 Forks. The fork and fork carrier shall conform to ANSI B56.1. Fork dimensions shall be 2.0 inches maximum thickness, 4.5 inches maximum width, and 42.0 (+/- 0.5) inches in length. Fork thickness shall not exceed 0.5 inch at the tip, and there shall be a taper on the u

14、nderside of the forks not less than 14 inches long. 3.10 Fork Positioner. The forks shall be capable of being laterally positioned manually without the need of tools. With the forks at their widest spacing, they shall spread at least 28 inches, measured from the outside of the forks. With the forks

15、at their narrowest spacing, they shall measure no more than 12 inches from outside to outside of the forks. 3.11 Side shift. The truck shall be equipped with a powered fork side shift that is operated by the seated operator. It shall side shift the forks not less than 4 inches each side center (8 in

16、ches total travel). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-58086A 33.12 Load backrest. A metal backrest or backrest with extension, shall be provided. There shall be no protruding bolts or appendages beyond the side plane of the load bac

17、krest. The load backrest, in conjunction with fork and hanger design, shall provide a vertical rear guard at least 47 inches high measured from the load carrying surfaces of the forks. 3.13 Uprights and carriage. With no load on the forks, the seated operator shall be able to see at least one fork t

18、ip at all lift heights and fork position. 3.14 Steering. Power steering shall be furnished. 3.15 Service Brakes. Service brakes conforming to ASME/ANSI. B56.1 shall be furnished. 3.16 Parking brake. Parking brake conforming to ASME/ANSI B56.1 shall be furnished. 3.17 Seat. The cushioned seat shall m

19、eet SAE J899 as a minimum requirement. 3.18 Operators overheard guard. The guard shall be in accordance with ASME/ANSI B56.1, including the falling-object-protective-structure (FOPS) requirements. Overhead guard height from the ground to the top of the overhead guard shall be not more than 84.0 inch

20、es. 3.18.1 Cab. When specified (see 7.3), a cab shall be furnished. It shall have FOPS capability per ASME/ANSI B56.1, and shall have two opening doors, and at least one fan for ventilation. There shall be sufficient window area to permit at least 250 degrees of horizontal visibility by the seated o

21、perator. The height from the ground to the top of the cab shall not be more than 84 inches. There shall be at least three wipers, one on the front windshield, one on the rear window, and one on the roof window. 3.18.1.1 Winterization C. When specified (see 7.3), the truck shall be equipped with a ca

22、b and shall protect to -25 degrees F. A cab heater and cab defroster shall be provided. If necessary, the cab shall contain thermal insulation to meet the heating requirements. 3.19 Horn. A horn shall be furnished, with the horn actuator located in the center of the steering wheel and within reach o

23、f the operator. 3.20 Controls and instrumentation markings. All controls and instrumentation shall be provided with position markings conforming to ASME/ANSI B56.11.3. All load motion controls shall be self-centering, that is, they shall return to the neutral position when released. 3.21 Indicators.

24、 The truck shall be equipped with a battery discharge indicator and an hour-meter, both visible to the seated operator. 3.22 Taillight. One combination stoplight and taillight shall be installed on the rear of the forklift. Provided by IHSNot for ResaleNo reproduction or networking permitted without

25、 license from IHS-,-,-A-A-58086A 43.23 External Lights. There shall be at least two sealed beam, 25 watts minimum, floodlights. One shall be facing forward, mounted on the upright or overhead guard, and one mounted in the rear, facing rearward. 3.24 Towing. A pin type towing device shall be recessed

26、 in the center rear of the truck. 3.25 Electromagnetic interference (EMI) suppression. The forklift shall comply with the EMI requirements shown in Table I. Table I. Electromagnetic Interference (EMI) Name Description Parameters SAE J551/1 Compatibility N/A SAE J551/2 Emissions Frequency Range: 30 t

27、o 1000 MHz SAE J551/11 Susceptibility Frequency Range: (100 kHz to 18 GHz) 20 v/m (100 kHz to 200 MHz) 50 v/m (above 200 MHz) 3.26 Painting. The forklift shall be primed and painted using standard commercial practices. The final color shall be color “yellow.” When specified (see 7.3), the final colo

28、r shall be 24052 of FED-STD-595, commonly called “forest green.” All stenciled words, symbols, or other markings (for example “3,000 POUND CAPACITY” or “LIFT HERE”), shall be black. 3.27 Walkway coating. Floor plates and step surfaces shall be coated with a non-slip coating compound or be furnished

29、with a non-slip metal surface in accordance with ASME/ANSIB56.1. 3.28 Tie-down provisions. Tie-down devices shall be furnished that withstand the following loads: 3.0 times the unloaded truck weight in the forward and aft directions, 2.0 times the unloaded truck weight in the downward direction, and

30、 1.5 times the unloaded truck weight in both lateral directions. Each device shall withstand at least 1.5 times the loads in the previous sentence without breaking or rupturing. The devices shall be not more than 1.0 inch thick, and the opening in the device shall be at least 3.0 inches in diameter.

31、 The word “TIEDOWN” shall be stenciled near each tie-down device. If possible, the tie-down devices may also be used as the slinging devices. 3.29 Informational aids. All stencils, decals, plates, or other similar items, that are provided on the manufacturers standard product shall be included on th

32、e forklift. This shall include, but not be limited to: rated capacity, all cautions and warnings, and all references to safety related items. 3.30 Performance. The truck shall be capable of meeting the following performance requirements: (1) Rated load. Capability to safely handle the rated load, de

33、fined as a 3,000 pound, 48 inch-per-side cube, with the center of gravity at the center of the cube. This cube shall be defined, and referred to in this document, as the rated load. The truck shall be able to safely handle this rated load at all lift heights and fork side shift distances that it is

34、capable of attaining. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-58086A 5(2) Lifting speed: At least 27 feet per minute with rated load on the forks. (3) Lowering speed: With rated load on forks, not more than 80 feet per minute. With unload

35、ed forks, not less than 30 feet per minute. (4) Service brake. With rated load, the truck shall be capable of meeting the stopping distance requirements of ANSI B56.1. (5) Parking brake. The brake shall be capable of holding the truck with rated load on a 15 percent grade in both forward and reverse

36、 directions. (6) Right angle turn. The truck, carrying rated capacity load, shall be capable of backing through a turn in either direction between two parallel walls not more than 135 inches apart. (7) Travel speed. Shall be capable of traveling at least six miles per hour, in both forward and rever

37、se directions, while carrying rated load on the forks. (8) Slope ascension. With the truck facing up the slope and with rated load on the forks, it shall be able to accelerate up a 15 percent (8.5 degrees) slope from a dead stop. (9) Upright tilt. With no load on the truck the upright (or mast) shal

38、l have at least 5.0 degrees forward tilt, and at least 8.0 degrees of rear tilt. Positive means shall be furnished to prevent cavitations of the tilt cylinders. (10) Collapsed mast height: Lowest upright height shall be 84.0 inches maximum with no load on the forks. (11) Maximum fork lift height. Wi

39、th rated load on forks and forks horizontal, the forks shall be capable of raising at least 185 inches. This shall be measured from ground to the horizontal, lifting surfaces of the forks. (12) Free lift height. With rated load on forks, and with the inner mast or carriage assembly just beginning to

40、 exceed the specified collapsed mast height, the distance from the ground to the top surfaces of the forks shall be not less than 35.0 inches. (13) Drift of load. With hydraulic fluid at normal operating temperature, lift assembly shall hold rated load at maximum lift height for at least 10.0 minute

41、s with not more than one inch of vertical drift, and not more than one degree of rotational drift. (14) Stability. The forklift shall meet the ANSI B56.1 “forward stacking”, “forward travel”, “lateral stacking”, and “lateral travel” stability requirements. (15) Tire loading. Under all fork loading c

42、onditions, from empty forks up to rated load, the weight on any tire shall not exceed the maximum allowed by the Tire and Rim Association Yearbook. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-58086A 63.31 Identification Plate. A corrosion res

43、istant identification plate shall be permanently installed at an easily accessible location. It shall contain the following information: NOMENCLATURE: MANUFACTURERS NAME: MANUFACTURERS ADDRESS: MANUFACTURERS SERVICE TELEPHONE NUMBER: MANUFACTURERS MODEL NUMBER: MANUFACTURERS SERIAL NUMBER: DATE OF M

44、ANUFACTURE CONTRACT NUMBER: NATIONAL STOCK NUMBER: REGISTRATION NUMBER: 3.32 Electrical system. All components necessary to make a complete electrical system shall be furnished. The truck shall be equipped with a backup alarm. 3.33 Tropical rust-proofing. When specified (see 7.3), tropical rust-proo

45、fing shall be provided. This should be considered a premium rust-proofing package usually consisting of an additional coating. The truck shall be treated with a corrosion preventative compound complying with A-A-59295. A copy of A-A-59295 can be requested from WR-ALC/LESVG. Many of these vehicles ar

46、e used in tropical/coastal environments and experience high humidity and salt spray. Therefore, they usually exhibit levels of corrosion in the areas listed below. At a minimum, these areas shall be coated: (1) Cab, interior (2) Cab, exterior (3) Seams (4) Welds (5) Hidden recessed areas (6)Location

47、s where dissimilar metals come in contact (7) Area above fuel tank(s) (8) Engine oil pan on paved or other hard surfaces 7.2 Source of documents. Military Specifications, Standards, and Handbooks referenced herein may be obtained online at http:/assist.daps.dla.mil/ or from the Standardization Docum

48、ent Order Desk, Building 4, Section D, 700 Robbins Avenue, Philadelphia, PA 19111-5094. The Society of Automotive Engineers (SAE) documents may be obtained online at http:/www.sae.org/ or from SAE, 400 Commonwealth Drive, Warrendale, PA 15096. ANSI/ASME documents may be obtained online at http:/www.

49、asme.org/ or from the American Society of Mechanical Engineers, 345 East 47thStreet, New York, NY 10017. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-58086A 8Underwriters Laboratories (UL) copies may be obtained online at http:/ or from: COMM 2000, 1414 Brook Drive, Downers Grove, IL 60515-5000. Federal Acquisition Regulation (FAR) referenced online at