AIR FORCE A-A-59575-2004 LIGHT UNIT PORTABLE (HAZARDOUS LOCATION USE FOR INSIDE PAINT SPRAY BOOTH)《便携灯设备(危险地点使用 低压交流控制柜)》.pdf

上传人:eventdump275 文档编号:427117 上传时间:2018-11-07 格式:PDF 页数:4 大小:94.30KB
下载 相关 举报
AIR FORCE A-A-59575-2004 LIGHT UNIT PORTABLE (HAZARDOUS LOCATION USE FOR INSIDE PAINT SPRAY BOOTH)《便携灯设备(危险地点使用 低压交流控制柜)》.pdf_第1页
第1页 / 共4页
AIR FORCE A-A-59575-2004 LIGHT UNIT PORTABLE (HAZARDOUS LOCATION USE FOR INSIDE PAINT SPRAY BOOTH)《便携灯设备(危险地点使用 低压交流控制柜)》.pdf_第2页
第2页 / 共4页
AIR FORCE A-A-59575-2004 LIGHT UNIT PORTABLE (HAZARDOUS LOCATION USE FOR INSIDE PAINT SPRAY BOOTH)《便携灯设备(危险地点使用 低压交流控制柜)》.pdf_第3页
第3页 / 共4页
AIR FORCE A-A-59575-2004 LIGHT UNIT PORTABLE (HAZARDOUS LOCATION USE FOR INSIDE PAINT SPRAY BOOTH)《便携灯设备(危险地点使用 低压交流控制柜)》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 INCH-POUND A-A-59575 April 19, 2004 COMMERCIAL ITEM DESCRIPTION LIGHT UNIT, PORTABLE, (HAZARDOUS LOCATION USE, FOR INSIDE PAINT SPRAY BOOTH) 1. SCOPE 1.1 SCOPE. This commercial item description covers a 120 VAC powered fluorescent light fixture mounted on wheels to provide illumination on the botto

2、m side of equipment while located inside a paint spray booth. Being intended for use inside paint spray booth the fixture will be certified for use in hazardous locations designated as Class I, Division 1, Group C Class I, Division 2, Group A, B, C Class II, Division 1 and Class III as defined by Na

3、tional Electric Code (NEC). The fixture will have four (4) quantity, 4 foot long, 430 mA, and 34 Watt Fluorescent lamps powered with 120V 60 Hz voltage. The fixture will be mounted as a portable unit on 4 oversized 5 inch casters, 1 pair fixed and 1 pair swivel and locking. 2. SALIENT CHARACTERISTIC

4、S. 2.1. Certification. The Portable Light fixture is suitable for use inside paint spray booth and UL tested/labeled/approved for use in designated hazardous and hostile locations in accordance to National Electric Code of: Class I, Division 1, Group C Class I, Division 2, Group A, B, C Class II, Di

5、vision 1 and Class III. 2.2. Light fixture. The fixture is four (4) quantity, 4 foot long, 430 mA, 34 Watt, rapid start, F40T12, medium bi-pin, fluorescent lamps powered with 120V 60 Hz voltage. Explosion-proof, impact, and heat resistant glass tubes provide lamp protection. A wire guard and clear p

6、olycarbonate shield provide additional security. Re-lamping can be done quickly from either end of the fixture with spring loaded sockets on both ends to hold lamps firmly for maximum. All lamp access covers are screw type and interchangeable, with “O-ring“ seals. The ballast housing is easily acces

7、sible and externally mounted with a class P, thermally protected and cold weather rated ballast being standard. AMSC N/A FSC 6230 Beneficial comments, recommendations, additions, deletions, clarification, etc. and any other data that may improve this document should be sent to: FSC6230 ENGR WR-ALCLE

8、EG, 295 Bryon Street, Robins AFB, GA 31098-1611 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59575 2.3 Frame. The frame shall be constructed of corrosion resistant copper-free aluminum alloy. 2.4 Mounting. The frame shall be portable by being

9、mounted on four casters with 5 inch outside diameter oversized wheels. On one end one pair shall be rigid and fixed and on the other end the other pair shall be of a swivel and locking type caster. 2.5 Multiple Reflective Positions. The unit has multiple reflective positions. The reflectors are heav

10、y gauge extruded aluminum (2.5 millimeters thick), with high gloss reflective finish that resist dents and corrosion and are also easily and quickly removed for cleaning. 2.6. Pulling handle. The unit has Pulling handle for ease of movement on the end of the mount with pair of swivel casters. 2.7 Ex

11、plosion proof switch and plug. The unit has explosion proof switch and plug. 2.8 Power Cord. The unit has SO (50 foot) cable suitable for rough duty. 2.9 Guard and Shield. The unit has protective wire guard and polycarbonate shield. 2.10 Wheels. The wheels are electrically conductive. 2.11 Envelope

12、Dimensions. Length (inches) 59 Width (inches) 25 Height (inches) 22 - 28 7/16 3. REGULATORY REQUIREMENTS 3.1 Recycled recovered materials. The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in accordance with paragraph 23.403 of the Federal Acquisition

13、 Regulation (FAR). 3. PRODUCT CONFORMANCE PROVISIONS 3.1 Product Conformance. The products produced shall meet all salient characteristics of this specification, conform to the producers own drawings, specifications, standards, and quality assurance practices, and be the same product offered for sal

14、e in the commercial market. The Government requires the manufacturer to submit with each unit a Certificate of Conformance 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59575 stating that all salient characteristics of this specification are

15、met. The Government reserves the right to return to the contractor any and all items that does not satisfactorily perform the necessary requirements. 3.2 Records. Records of examinations and tests performed by or for the contractor shall be maintained by the contractor and made available to the Gove

16、rnment upon the Governments request, at any time, or from time to time, during the performance of the contract and for a period of three years after delivery of the supplies to which such records relate. 3.2 Hazardous Location Certification. All supplied items shall carry a UL standard commercial ce

17、rtification label referencing Hazardous Locations certified for and testing document number. One copy of the certification information shall be shipped to the cognizant engineer at this location; FSC 6230 Engineer, WR-ALC/LEEG, 295 Byron Street, Robins AFB, GA 31098-1611. 4. PACKAGING 4.1 PACKAGING.

18、 Preservation, packing, and marking shall be as specified in the contract or order. 5. NOTES 5.1 Alternative offers. Alternate Offers considered as dealers/distributors of above approved manufacturer suggested sources of supply are also considered approved vendor sources of supply provided they can

19、certify they are proposing to supply one of the above approved CAGE/part numbers. All other alternate offers, a.) Not listed as a suggested source of supply above, b.) Having a product that meets above salient characteristics, c.) Being UL or FM tested/approved/listed/labeled for Hazardous Location,

20、 CLASS I DIVISION 1 GROUP C& D and CLASS II DIVISION 1 GROUP F & G, and d.) Desiring to receive a contract to furnish their product for USAF use shall first submit an item for technical evaluation/approval by the FSC 6230 cognizant engineer. 5.2 SUGGESTED SOURCES OF SUPPLY The following table lists

21、current sources: MFG SOURCE(S) OF SUPPLY NAME & ADDRESS CAGE PART NUMBER Rig-A-Lite, Inc. PO Box 12942, 8500 Hansen Road Houston, Texas 77217-22942 Tel: (713) 943-0340 / Fax: (713) 943-8354 31655 XPPL430-4-4L-A 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr

22、om IHS-,-,-A-A-59575 Authorized dealers and distributors of above manufacturers are also considered approved sources of supply provided they certify that they are proposing to supply one of prior approved manufacturer items. 6230-01-306-9702 Custodian: Preparing Activity: Air Force - 99 Air Force 84

23、 Agent Activity: Air Force 9 (Project No. 6230-1090) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at www.dodssp.daps.mil. 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1