ANS 56.8-2002 Containment System Leakage Testing Requirements (Incorporating Errata April 16 2018)《容载系统泄漏测试要求》.pdf

上传人:Iclinic170 文档编号:429347 上传时间:2018-11-07 格式:PDF 页数:41 大小:463.39KB
下载 相关 举报
ANS 56.8-2002 Containment System Leakage Testing Requirements (Incorporating Errata April 16 2018)《容载系统泄漏测试要求》.pdf_第1页
第1页 / 共41页
ANS 56.8-2002 Containment System Leakage Testing Requirements (Incorporating Errata April 16 2018)《容载系统泄漏测试要求》.pdf_第2页
第2页 / 共41页
ANS 56.8-2002 Containment System Leakage Testing Requirements (Incorporating Errata April 16 2018)《容载系统泄漏测试要求》.pdf_第3页
第3页 / 共41页
ANS 56.8-2002 Containment System Leakage Testing Requirements (Incorporating Errata April 16 2018)《容载系统泄漏测试要求》.pdf_第4页
第4页 / 共41页
ANS 56.8-2002 Containment System Leakage Testing Requirements (Incorporating Errata April 16 2018)《容载系统泄漏测试要求》.pdf_第5页
第5页 / 共41页
亲,该文档总共41页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、ANSI/ANS-56.8-2002containment system leakagetesting requirementsANSI/ANS-56.8-2002REAFFIRMED August 9, 2011 ANSI/ANS-56.8-2002 (R2011) This standard has been reviewed and reaffirmed with the recognition that it may reference other standards and documents that may have been superseded or withdrawn. T

2、he requirements of this document will be met by using the version of the standards and documents referenced herein. It is the responsibility of the user to review each of the references and to determine whether the use of the original references or more recent versions is appropriate for the facilit

3、y. Variations from the standards and documents referenced in this standard should be evaluated and documented. This standard does not necessarily reflect recent industry initiatives for risk informed decision-making or a graded approach to quality assurance. Users should consider the use of these in

4、dustry initiatives in the application of this standard. ANSI/ANS-56.8-2002American National StandardContainment System LeakageTesting RequirementsSecretariatAmerican Nuclear SocietyPrepared by theAmerican Nuclear SocietyStandards CommitteeWorking Group ANS-56.8Published by theAmerican Nuclear Societ

5、y555 North Kensington AvenueLa Grange Park, Illinois 60526 USAApproved November 27, 2002by theAmerican National Standards Institute, Inc.AmericanNationalStandardDesignation of this document as an American National Standard attests thatthe principles of openness and due process have been followed in

6、the approvalprocedure and that a consensus of those directly and materially affected bythe standard has been achieved.This standard was developed under procedures of the Standards Committee ofthe American Nuclear Society; these procedures are accredited by the Amer-ican National Standards Institute,

7、 Inc., as meeting the criteria for AmericanNational Standards. The consensus committee that approved the standardwas balanced to ensure that competent, concerned, and varied interests havehad an opportunity to participate.An American National Standard is intended to aid industry, consumers, gov-ernm

8、ental agencies, and general interest groups. Its use is entirely voluntary.The existence of an American National Standard, in and of itself, does notpreclude anyone from manufacturing, marketing, purchasing, or using prod-ucts, processes, or procedures not conforming to the standard.By publication o

9、f this standard, the American Nuclear Society does not insureanyone utilizing the standard against liability allegedly arising from or afterits use. The content of this standard reflects acceptable practice at the time ofits approval and publication. Changes, if any, occurring through developmentsin

10、 the state of the art, may be considered at the time that the standard issubjected to periodic review. It may be reaffirmed, revised, or withdrawn atany time in accordance with established procedures. Users of this standardare cautioned to determine the validity of copies in their possession and toe

11、stablish that they are of the latest issue.The American Nuclear Society accepts no responsibility for interpretations ofthis standard made by any individual or by any ad hoc group of individuals.Requests for interpretation should be sent to the Standards Department atSociety Headquarters. Action wil

12、l be taken to provide appropriate response inaccordance with established procedures that ensure consensus on theinterpretation.Comments on this standard are encouraged and should be sent to SocietyHeadquarters.Published byAmerican Nuclear Society555 North Kensington AvenueLa Grange Park, Illinois 60

13、526 USACopyright 2003 by American Nuclear Society. All rights reserved.Any part of this standard may be quoted. Credit lines should read “Extracted fromAmerican National Standard ANSI0ANS-56.8-2002 with permission of the publisher,the American Nuclear Society.” Reproduction prohibited under copyrigh

14、t conventionunless written permission is granted by the American Nuclear Society.Printed in the United States of AmericaForewordThis foreword is not part of American National Standard for Containment System Leakage TestingRequirements, ANSI0ANS-56.8-2002.!This standard provides a basis for determini

15、ng leakage rates through the primary reactorcontainment systems of light-water-cooled nuclear power plants. This revision is intendedfor use with Option B of 10 CFR 50, Appendix J, and is not suitable for use with Option Aof Appendix J.The leakage rate tests performed on the primary reactor containm

16、ent system simulatesome of the conditions e.g., penetrations vented, flooded, or in operation! that existduring a design-basis accident. The test methodology and the associated requirements forboth whole containment integrated! and individual pathway local! leakage rate testingare contained in this

17、document.The appendices contain Type A and verification test methods, formula derivations, con-tainment atmosphere stabilization criteria, and test termination criteria.The regulatory requirements for containment leakage rate testing are contained in Title10, “Energy,” Code of Federal Regulations CF

18、R!, Part 50, “Domestic Licensing of Produc-tion and Utilization Facilities,” Appendix J, “Primary Reactor Containment LeakageTesting For Water-Cooled Power Reactors.”The previous revision to this standard was issued in 1994. 10 CFR 50, Appendix J,underwent a major revision in 1995. The content of 10

19、 CFR 50, Appendix J, as it wasbefore the revision, was retained in the new revision; only now it is known as “Option APrescriptive Requirements.” The revision also added a second option, “Option BPerformance-Based Requirements,” which contains risk-informed, performance-basedrequirements for contain

20、ment leakage rate testing. The most significant changes embod-ied in Option B allow much longer intervals between tests, based on good performance ofthe structure or component being tested.The U.S. Nuclear Regulatory Commission has also issued Regulatory Guide 1.163,“Performance-Based Containment Le

21、ak-Test Program,” dated September 1995, to provideguidance on complying with Option B of 10 CFR 50, Appendix J. Regulatory Guide 1.163endorses, with several exceptions, NEI 94-01, “Industry Guideline For ImplementingPerformance-Based Option of 10 CFR Part 50, Appendix J,” Revision 0, which in turnen

22、dorses the 1994 edition of this standard, with certain changes due to the nonperformance-based nature of the 1994 standard.This revision of the standard has been written to consolidate into one document guide-lines for testing under Option B. This will eliminate the need to refer to three separatedo

23、cuments Regulatory Guide 1.163, NEI 94-01, and ANSI0ANS-56.8-1994! and the at-tendant inefficiency and confusion such a situation can cause. Option B requires areference in each plants Technical Specifications to the implementation document used todevelop the leakage testing program; this revision t

24、o the standard has been written sothat it may be referenced in Technical Specifications as the implementation documentrather than Regulatory Guide 1.163 and its chain of subordinate documents.Working Group ANS-56.8 of the Standards Committee of the American Nuclear Societyhad the following membershi

25、p at the time it approved this standard:iJ. Glover, Chair, Graftel, Inc.H. Hill, BCP Technical ServicesM. Jennex, San Diego State University Foundation for Knowledge ManagementD. Lurie, U.S. Nuclear Regulatory CommissionM. Hutcheson, Duke Energy CompanyJ. Pulsipher, U.S. Nuclear Regulatory Commissio

26、nB. Patel, ConsultantR. Shirk, PPL SusquehannaT. Newton, Nuclear Management CorporationK. Clark, Tennessee Valley AuthorityP. Chang, Southern California EdisonW. Brown, Duke Energy CompanyD. Oakley, Exelon CorporationThis standard was processed and approved for submittal to ANSI by the Ameri-can Nuc

27、lear Societys Nuclear Facilities Standards Committee NFSC!. Commit-tee approval of the standard does not necessarily imply that all committee membersvoted for its approval. At the time it approved this standard, the NFSC committeehad the following members:D. J. Spellman, Chair, Oak Ridge National La

28、boratoryS. Ahmad, Standards Administrator, American Nuclear SocietyC. K. Brown, Southern Nuclear Operating CompanyR. H. Bryan, Jr., Tennessee Valley AuthorityH. Chander, U.S. Department of EnergyJ. D. Cohen, Westinghouse Savannah River CompanyM. T. Cross, Westinghouse Electric CompanyD. Eggett, AES

29、EngineeringR. A. Hill, GE Nuclear EnergyN. P. Kadambi, U.S. Nuclear Regulatory CommissionJ. Love, Bechtel Power CorporationJ. T. Luke, Exelon NuclearJ. F. Mallay, Framatome ANPR. H. McFetridge, Westinghouse Electric CompanyC. H. Moseley, BWXT Y-12N. Norman, Parsons Engineering ServicesW. N. Prillama

30、n, Framatome ANPW. B. Reuland, Electric Power Research InstituteM. Ruby, Rochester Gas 2! test instrumentation;3! test procedures;4! test methods;5! acceptance criteria;6! data analysis;7! inspection and recording of test results.2 Definitions1!The following terms are for general use inthisstandard:

31、acceptance criteria: The standards againstwhich test results are to be compared for es-tablishing the functional acceptability of theprimary containment as a leakage limitingboundary.accuracy: Conformity of an indicated value toan accepted standard value or true value.active failure: A malfunction o

32、f a componentthat relies on mechanical movement or changeof state to complete its intended function upondemand. Examples of active failures includethe failure of a valve or a check valve to moveto its correct position, or the failure of a pump,fan, or diesel generator to start. Spurious ac-tion of a

33、 power-operated component originat-ing within its actuation or control system shallbe regarded as an active failure unless specificdesign features or operating restrictions pre-clude such spurious action. An example is theunintended energization of a power-operatedvalve to open or close.administrati

34、ve limit: Leakage limit assignedto each Type B or Type C component as anindication of potential valve or penetration deg-radation and used to establish Type B and TypeC test performance-based intervals.as-found leakage rate: The leakage rate priorto any repairs or adjustments to the barrierbeing tes

35、ted.as-found testing: Leakage rate testing aftersome period of normal service conditions, per-formed prior to any repairs or adjustments.as-left leakage rate: The leakage rate follow-ing any repairs or adjustments to the barrierbeing tested.as-left testing: Leakage rate testing per-formed following

36、repairoradjustment.confidence level: The probability that the trueleakage rate does not exceed the upper confi-dence limit UCL!.1!Specialized definitions used in the appendices are defined in the appendix where they are used.1containment atmosphere mass weightedaverage temperature (T): The temperatu

37、rederived from weighting each temperature sen-sor reading by the mass it represents.containment integrated leakage rate test(CILRT): The leakage rate test performed onthe primary containment by simulating someof the conditions e.g., penetrations vented,drained, flooded, or in operation!that exist du

38、r-ing a design-basis accident DBA!. The CILRTconsists of the following phases or activities:1! inspecting the primary containment;2! pressurizing the primary containmentsystem;3! stabilizing the containment atmosphere;4! conducting a Type A test;5! conducting a verification test;6! depressurizing th

39、e primary containment.containment isolation valve: A valve subjectto Title 10, “Energy,” Code of Federal Regula-tions CFR!, Part 50, “DomesticLicensing ofProduction and Utilization Facilities,” Appen-dixA,“General Design Criteria,” Criteria 55,56, and 57,2!and also comparable valves inthose plants n

40、ot required to conform to Appen-dixAtothis part. A containment isolation valveis any valve that is relied upon to provide abarrier between the containment environmentand the outside environment under postacci-dent loss-of-coolant conditions, in the plantslicensing basis.continuous leakage monitoring

41、 system: Apermanently installed, on-line pneumatic mea-surement system that continuously monitorsthe leakage rate of containment system pene-trations at a pressure not less than Pa.containment leakage rate test program: Thecomprehensive testing of the primary contain-ment that includes Type A, Type

42、B, Type C,and leakage rate verification tests.data set: The set of readings from all primarytest instrumentation for a CILRT taken over asingle scan of the data acquisition systemDAS!or CILRT software.design-basis accident (DBA): The accidentinitiated by a single component failure or oper-ator error

43、, as described in the safety analysisofthe plant, that results in the maximum pri-mary containment internal peak pressure andinfission product release to the containmentatmosphere.extended test interval: The maximum allow-able Type A, Type B, or Type C test intervalfollowing the demonstration of goo

44、d perfor-mance history.initial test interval: The allowable Type A,Type B, or Type C test interval prior to thedemonstration of good performance history.La(wt%/24 h): The maximum allowable TypeA test leakage rate at Pa.Lam(wt%/24 h): Estimate of the leakage rate,derived as a function of the least sq

45、uares slopeand intercept, for the Type A test at pressurePaobtained from testing the primary contain-ment by simulating some of the conditions thatwould exist under DBA conditionse.g., vented,drained, flooded, or pressurized!.Lc(wt%/24 h): The composite primary contain-ment leakage rate measured usi

46、ng the CILRTinstruments after L0is superimposed.L0(wt%/24 h): The known leakage rate super-imposed on the primary containment duringthe verification test.leak: An opening that allows the passage offluid through it.leakage: The quantity of fluid escaping from aleak or leaks.leakage rate: The rate at

47、which the containedfluid escapes from the test volume at a speci-fied test pressure.local leakage rate test (LLRT): The leakagerate test performed on Type B and Type Ccomponents.2!Title 10, “Energy,” Code of Federal Regulations, Part 50, “DomesticLicensing of Production and UtilizationFacilities,” A

48、ppendixA,“General Design Criteria,” Criteria 55, 56, and 57. Available from the Superintendentof Documents, Government Printing Office, Washington, D.C. 20402.American National Standard ANSI0ANS-56.8-20022maximum pathway leakage rate (MXPLR)3!:The maximum leakage rate attributed to a pene-tration le

49、akage path. The MXPLR is the larger,not the total, leakage of two barriers in series.minimum pathway leakage rate (MNPLR)3!:The minimum leakage rate that can be attrib-uted to a penetration leakage path e.g., thesmaller of either the inboard or outboard bar-riers individual leakage rates!. The pathwaysMNPLR can be determined by one-half of thetotal measured leakage rate when tested bypressurizing between the inboard and out-board barriers.overall integrated leakage rate: The totalleakage through all tested leakage paths in-cluding containment welds, valves

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1