ANSI American Society of Sanitary Engineering 1057-2012 Performance Requirements for Freeze Resistant Sanitary Yard Hydrants with Backflow Protection.pdf

上传人:hopesteam270 文档编号:430865 上传时间:2018-11-11 格式:PDF 页数:28 大小:1.24MB
下载 相关 举报
ANSI American Society of Sanitary Engineering 1057-2012 Performance Requirements for Freeze Resistant Sanitary Yard Hydrants with Backflow Protection.pdf_第1页
第1页 / 共28页
ANSI American Society of Sanitary Engineering 1057-2012 Performance Requirements for Freeze Resistant Sanitary Yard Hydrants with Backflow Protection.pdf_第2页
第2页 / 共28页
ANSI American Society of Sanitary Engineering 1057-2012 Performance Requirements for Freeze Resistant Sanitary Yard Hydrants with Backflow Protection.pdf_第3页
第3页 / 共28页
ANSI American Society of Sanitary Engineering 1057-2012 Performance Requirements for Freeze Resistant Sanitary Yard Hydrants with Backflow Protection.pdf_第4页
第4页 / 共28页
ANSI American Society of Sanitary Engineering 1057-2012 Performance Requirements for Freeze Resistant Sanitary Yard Hydrants with Backflow Protection.pdf_第5页
第5页 / 共28页
点击查看更多>>
资源描述

1、Freeze Resistant Sanitary Yard Hydrants with Backflow Protection 1ASSE 1057-2012Performance Requirements forFreeze Resistant Sanitary Yard Hydrants with Backflow ProtectionAmerican Society of Sanitary EngineeringASSE Standard #1057-2012ASSE Board Approved: July, 2012ANSI Approved: August, 2012An Ame

2、rican National StandardFreeze Resistant Sanitary Yard Hydrants with Backflow Protection iASSE 1057-2012General InformationNeither this standard, nor any portion thereof, may be reproduced without the written consent of the American Society of Sanitary Engineering.No product may be said to be ASSE li

3、sted unless the manufacturer has applied to ASSE, has had its product tested according to the applicable standards, the product has passed the test and displays the ASSE Seal on the product.Instructions for receiving authorization to display the ASSE Seal are available from ASSEs International Offic

4、e. Organizations wishing to adopt or list any ASSE Standard should print the ASSE Standard number on the cover page first and in equal or larger type to that of the adopting or listing organization.American Society of Sanitary EngineeringWestlake, OhioCopyright 2012, 2001, 1993All rights reserved.ii

5、 Freeze Resistant Sanitary Yard Hydrants with Backflow ProtectionASSE 1057-2012Freeze Resistant Sanitary Yard Hydrants with Backflow Protection iiiASSE 1057-2012ForewordThis foreword is not considered a part of the standard. However, it is offered to provide background information.It is currently re

6、cognized that the common garden or utility hose, when connected to a potable water supply by means of a hose threaded outlet, constitutes a potential cross-connection. It is also currently recognized that the same cross-connection may exist when a potable water supply is permitted to drain undergrou

7、nd.With specific reference to Freeze Resistant Sanitary Yard Hydrants, this standard has been developed to protect the potable water supply from backflow contamination and ground water contamination.It has been recognized that five types of yard hydrants need to be considered to protect against free

8、zing. The types considered are: Type 1, which provides protection with two check valves and an atmospheric vent and does not require removal of the hose to provide freeze protection; Type 2, which provides protection with two check valves and an atmospheric vent and requires removal of the hose to p

9、rovide freeze protection; Type 3, which provides protection with one check valve and an atmospheric vent and does not require removal of the hose to provide freeze protection; Type 4, which provides protection with one check valve and an atmospheric vent and requires removal of the hose to provide f

10、reeze protection; and Type 5, which has an air gap or removable backflow protection device and requires removal of the backflow protection device and hose to provide freeze protection.Although many of the material specifications are detailed within Section 4.1 of this standard, it is the responsibil

11、ity of the manufacturer and installer to comply with the relevant jurisdictional requirements.The working group, which developed this standard revision, was set up within the framework of the Product Standards Committee of the American Society of Sanitary Engineering.Recognition is made of the time

12、volunteered by members of this working group and of the support of the manufacturers who also participated in the meetings for this standard.The standard does not imply ASSEs endorsement of a product which conforms to these requirements.Compliance with this standard does not imply acceptance by any

13、code body.iv Freeze Resistant Sanitary Yard Hydrants with Backflow ProtectionASSE 1057-2012It is recommended that these devices be installed consistent with local codes by qualified and trained professionals.This standard was promulgated in accordance with procedures developed by the American Nation

14、al Standards Institute (ANSI).This edition was approved by the ASSE Board of Directors on July 2, 2012 as an ASSE standard.Freeze Resistant Sanitary Yard Hydrants with Backflow Protection vASSE 1057-2012Joseph Fugelo, ChairmanLabov Co.Philadelphia, PennsylvaniaRand AckroydRand Technical Consulting,

15、LLCNewburyport, MassachusettsWilliam Briggs Jr.MGJ AssociatesNew York, New YorkMaribel CamposICC Evaluation ServicesWhittier, CaliforniaJudson CollinsJULYCOMannford, OklahomaRon GeorgePlumb-Tech Design (2) Raise the vacuum slowly from 0.0 inches (0.0 mm) to 25.0 inches (635.0 mm) of mercury and then

16、 slowly reduce it to 0.0 inches (0.0 mm) of mercury; and(3) Create a surge effect by opening and closing a quick acting valve. The applied vacuum shall vary between 0.0 inches (0.0 mm) to 25.0 inches (635.0 mm) of mercury during the test.10 Freeze Resistant Sanitary Yard Hydrants with Backflow Prote

17、ctionASSE 1057-2012Figure 7Vacuum PumpVacuum TankGaugeShut-offValveQuick Acting ValveVacuum RegulatorDevice on TestSight Glass ScaleReservoir3.9.3 CriteriaA rise of water in the sight glass, including a bowing of the meniscus, exceeding a rise of 3.0 inches (76.2 mm) above the water in the reservoir

18、 shall result in a rejection of the device. 3.10 Backsiphonage and Backpressure (Types 1 and 2) 3.10.1 PurposeThe purpose of this test is to ensure that the backflow prevention device prevents backflow due to backsiphonage.3.10.2 ProcedureThe inlet check valve shall be fouled with a 0.032 inch (0.81

19、3 mm) diameter fouling wire (see Appendix A for fouling wire examples). The outlet check valve shall be in its normal closed position. Install the device as shown in Figure 8 and open the supply valve to maintain 3.0 psi (20.7 kPa) at the outlet of the device. The following vacuum loads shall be app

20、lied in sequence:(1) Apply and hold a vacuum of 25.0 inches (635.0 mm) of mercury for five (5) minutes;(2) Raise the vacuum slowly from 0.0 inches (0.0 mm) to 25.0 inches (635.0 mm) of mercury and then slowly reduce it to 0.0 inches (0.0 mm) of mercury; and (3) Create a surge effect by opening and c

21、losing a quick acting valve. The applied vacuum shall vary between 0.0 inches (0.0 mm) to 25.0 inches (635.0 mm) of mercury during the test.Repeat the test with the outlet check valve fouled with a 0.032 inch (0.813 mm) diameter fouling wire (see Appendix A for fouling wire examples). The inlet chec

22、k valve shall be in its normal closed position.Freeze Resistant Sanitary Yard Hydrants with Backflow Protection 11ASSE 1057-2012Figure 8 PrimarySupplyGaugeRingPiezometerInletVacuumsystem similarto Figure 7OutletDevice on TestSupplyValveSight Glass3.10.3 CriteriaAny indication of flow of water from t

23、he outlet of the device into the inlet piping shall result in a rejection of the device.3.11 Relief of Intermediate Chamber Pressure (Types 1 and 2) 3.11.1 PurposeThe purpose of this test is to determine if the intermediate chamber pressure will be relieved when the device is pressurized to 100.0 ps

24、i (689.5 kPa) or the manufacturers maximum rated working pressure, whichever is greater, and the inlet pressure suddenly drops to 0.0 psi (0.0 kPa).3.11.2 ProcedureInstall the device as shown in Figure 5. Open Valve #1 and Valve #2 and flow water through the device to purge it of air. Close Valve #2

25、 and raise the pressure to 100.0 psi (689.5 kPa) or the manufacturers maximum rated working pressure, whichever is greater. Close Valve #1. Open the quick acting valve to drop the pressure at the inlet of the device to atmospheric pressure. The pressure in the intermediate chamber shall be dissipate

26、d quickly, as indicated by the discharge of water through the atmospheric vents.3.11.3 CriteriaFailure of the atmospheric vents to open and dissipate pressure in the intermediate chamber shall result in a rejection of the device.3.12 Backflow Prevention (Types 3, 4 and 5)3.12.1 PurposeThe purpose of

27、 this test is to determine if the atmospheric vent opening relieves the outlet pressure when the supply pressure drops to 0.0 psi (0.0 kPa).3.12.2 ProcedureThe device shall be installed in a test system, as shown in Figure 9. The hose connected to the outlet of the device shall be 0.5 inch (12.7 mm)

28、 nominal inside diameter, 25.0 feet (7.6 m) in length and having a quick closing nozzle on its discharge end. Purge the test set-up of air and then pressurize the system to 100.0 psi (689.5 kPa) or the manufacturers maximum rated working pressure, whichever is greater, with water at ambient temperat

29、ure. The supply valve shall be closed and then a quick-acting valve shall be opened to drop the pressure in the inlet of the device to 0.0 psi (0.0 kPa). The pressure in the hose line shall be dissipated quickly by the discharge of water through the vent ports.12 Freeze Resistant Sanitary Yard Hydra

30、nts with Backflow ProtectionASSE 1057-2012Figure 9GaugeSnubberHoseNozzleDevice on TestShut-offValve Quick Acting Valve3.12.3 CriteriaFailure of the device to begin to relieve the outlet pressure through the vent port when the supply pressure reaches 0.0 psi (0.0 kPa) shall result in the rejection of

31、 the device.3.13 Backflow Preventer Attachment Requirements3.13.1 PurposeThe purpose of this test is to ensure that the manufacturer has provided a means of securing the mechanical backflow preventer or, where removable, shall provide a means to prohibit future hose connections.3.13.2 ProcedureAttem

32、pt to remove the mechanical backflow preventer by applying a torque of 180.0 in-lb (20.3 Nm) at the base of the mechanical backflow preventer. Mechanical backflow preventers which cannot be removed by this method shall be deemed non-removable. Where the mechanical backflow preventer is removed, the

33、remaining outlet shall have a minimum outside cross- sectional dimension of at least 1.0 inch (25.4 mm). Attempt to attach a garden hose with threaded connectors to the outlet of the device.3.13.3 CriteriaAny indication that the backflow preventer can be removed by applying a torque of less than 180

34、.0 in-lb (20.3 Nm) or, once removed, that a garden hose with threaded connectors can be reattached to the outlet shall result in a rejection of the device. 3.14 Flow Rates and Pressure Loss3.14.1 PurposeThe purpose of this test is to determine the pressure loss at rates of flow as identified per Tab

35、le 1.3.14.2 ProcedureThe device shall be installed in the open position in the test system, as shown in Figure 1, equipped with a means for accurately measuring the rate of ambient water flow and pressure loss across the device. Purge the system of air and close the throttling valve. The throttling

36、valve shall then be slowly opened until the 25.0 psi (172.4 kPa) pressure differential is reached.Freeze Resistant Sanitary Yard Hydrants with Backflow Protection 13ASSE 1057-2012Table 1Outlet of Device Minimum Flow Rate Maximum Allowable Pressure Loss NH GPM L/s psi kPa 4.00 0.25 25.0 172.4 1 8.00

37、0.50 25.0 172.4 3.14.3 CriteriaFailure of the device to meet the flow requirements of Table 1, at or below the maximum allowable pressure loss of 25.0 psi (172.4 kPa), shall result in a rejection of the device.14 Freeze Resistant Sanitary Yard Hydrants with Backflow ProtectionASSE 1057-2012Section I

38、V4.0 Detailed Requirements4.1 Materials4.1.1 Materials in Contact with WaterSolder and fluxes containing lead in excess of 0.2% shall not be used in contact with potable water.4.1.2 Corrosion ResistanceInternal moving parts shall be of a material having a corrosion resistance at least equal to an al

39、loy of not less the 58% copper.4.2 InstructionsInstructions shall accompany each device and shall provide all information, including illustrations, necessary for correct installation, operation, maintenance and repair of the device.4.3 Marking4.3.1 Each device shall have the following information ma

40、rked on it where it will be visible after the device has been installed:a) Name of manufacturer/marketer or trademark.b) Type and model number of the device.4.3.2 Markings shall be cast, etched, stamped or engraved on the body of the device or on a corrosion resistant material plate securely fastene

41、d to the device.Freeze Resistant Sanitary Yard Hydrants with Backflow Protection 15ASSE 1057-2012Section V5.0 DefinitionsDefinitions not found in this section are located in the Plumbing Dictionary, Sixth Edition, published by ASSE. 16 Freeze Resistant Sanitary Yard Hydrants with Backflow Protection

42、ASSE 1057-2012Appendix A(a) Slitted Disk (b) Bevel Seat (c) O-Ring Seat (d) Flat Disc & Seat(e) Swing Check (f) Poppet TypeNozzle Type Body(g) Poppet TypeFlat or level seat body(h)American Society of Sanitary Engineering901 Canterbury Road, Suite A Westlake, Ohio 44145Phone (440) 835-3040 Fax (440) 835-3488E-Mail general.infoasse-plumbing.org Web: www.asse-plumbing.org

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1