ANSI ASSE A10.7-2011 Safety Requirements for Transportation Storage Handling and Use of Commercial Explosives and Blasting Agents《商用炸药和起爆剂的运输 存储 装卸和使用的安全要求》.pdf

上传人:amazingpat195 文档编号:432196 上传时间:2018-11-11 格式:PDF 页数:70 大小:766.74KB
下载 相关 举报
ANSI ASSE A10.7-2011 Safety Requirements for Transportation Storage Handling and Use of Commercial Explosives and Blasting Agents《商用炸药和起爆剂的运输 存储 装卸和使用的安全要求》.pdf_第1页
第1页 / 共70页
ANSI ASSE A10.7-2011 Safety Requirements for Transportation Storage Handling and Use of Commercial Explosives and Blasting Agents《商用炸药和起爆剂的运输 存储 装卸和使用的安全要求》.pdf_第2页
第2页 / 共70页
ANSI ASSE A10.7-2011 Safety Requirements for Transportation Storage Handling and Use of Commercial Explosives and Blasting Agents《商用炸药和起爆剂的运输 存储 装卸和使用的安全要求》.pdf_第3页
第3页 / 共70页
ANSI ASSE A10.7-2011 Safety Requirements for Transportation Storage Handling and Use of Commercial Explosives and Blasting Agents《商用炸药和起爆剂的运输 存储 装卸和使用的安全要求》.pdf_第4页
第4页 / 共70页
ANSI ASSE A10.7-2011 Safety Requirements for Transportation Storage Handling and Use of Commercial Explosives and Blasting Agents《商用炸药和起爆剂的运输 存储 装卸和使用的安全要求》.pdf_第5页
第5页 / 共70页
点击查看更多>>
资源描述

1、Printed in U.S.A.A SS EAMERICAN SOCIETY OFSAFETY ENGINEERSAMERICAN NATIONAL STANDARDANSI/ASSE A10.7 2011ANSI/ASSE A10.7 2011ANSI/ASSE A10.7 2011Safety Requirements forTransportation, Storage, Handling and Use of Commercial Explosives and Blasting AgentsAmerican National Standardfor Construction and

2、Demolition OperationsCopyright American Society of Safety Engineers Provided by IHS under license with ASSE/SAFE Licensee=CHINA STDS INFORMATION CENTER - avada indx app by/5954931001, User=ZhaoNot for Resale, 05/02/2012 00:36:12 MDTNo reproduction or networking permitted without license from IHS-,-,

3、-The information and materials contained in this publication have been developed from sources believed to be reliable. However, the American Society of Safety Engineers (ASSE) as secretariat of the ANSI accredited A10 Committee or individual committee members accept no legal responsibility for the c

4、orrectness or completeness of this material or its application to specific factual situations. By publication of this standard, ASSE or the A10 Committee does not ensure that adherence to these recommendations will protect the safety or health of any persons, or preserve property. Copyright American

5、 Society of Safety Engineers Provided by IHS under license with ASSE/SAFE Licensee=CHINA STDS INFORMATION CENTER - avada indx app by/5954931001, User=ZhaoNot for Resale, 05/02/2012 00:36:12 MDTNo reproduction or networking permitted without license from IHS-,-,-ANSI ANSI/ASSE A10.7 2011 American Nat

6、ional Standard Construction and Demolition Operations Safety Requirements for Transportation, Storage, Handling and Use of Commercial Explosives and Blasting Agents Secretariat American Society of Safety Engineers 1800 East Oakton Street Des Plaines, Illinois 60018-2187 Approved: August 8, 2011 Effe

7、ctive: December 12, 2011 American National Standards Institute, Inc. Copyright American Society of Safety Engineers Provided by IHS under license with ASSE/SAFE Licensee=CHINA STDS INFORMATION CENTER - avada indx app by/5954931001, User=ZhaoNot for Resale, 05/02/2012 00:36:12 MDTNo reproduction or n

8、etworking permitted without license from IHS-,-,-Approval of an American National Standard requires verification by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the A

9、NSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effor

10、t be made toward their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he/she has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not con

11、forming to the standards. The American National Standards Institute does not develop standards and will in no circumstance give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in th

12、e name of the American National Standards Institute. Requests for interpretation should be addressed to the secretariat or sponsor whose name appears on the title page of this standard. Caution Notice: This American National Standard may be revised or withdrawn at any time. The procedures of the Ame

13、rican National Standards Institute requires that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published Septembe

14、r, 2011 by: American Society of Safety Engineers 1800 East Oakton Street Des Plaines, Illinois 60018-2187 (847) 699-2929 www.asse.org Copyright 2011 by the American Society of Safety Engineers All Rights Reserved. No part of this publication may be reproduced in any form, in an electronic retrieval

15、system or otherwise, without the prior written permission of the publisher. Printed in the United States of America American National Standard Copyright American Society of Safety Engineers Provided by IHS under license with ASSE/SAFE Licensee=CHINA STDS INFORMATION CENTER - avada indx app by/595493

16、1001, User=ZhaoNot for Resale, 05/02/2012 00:36:12 MDTNo reproduction or networking permitted without license from IHS-,-,-Foreword (This Foreword is not a part of American National Standard A10.7-2011.) This standard is one of a series of safety standards that have been formulated by the Accredited

17、 Standards Committee on Safety in Construction and Demolition Operations, A10. It is expected that the standards in the A10 series will find a major application in industry, serving as a guide to contractors, labor, and equipment manufacturers. For the convenience of users, a list of existing and pr

18、oposed standards in the A10 series for Safety Requirements in Construction and Demolition Operations follows. A10.1 Pre-Project/Pre-Task Safety Approval. Sanctioned, endorsed, accredited, certified, or accepted as satisfactory by an authority having jurisdiction. 3.4 Authorized; Authorization. Appro

19、ved or assigned by the employer to perform a specific type of duty or duties or to be at a specific location or locations at the jobsite. 3.5 Authority Having Jurisdiction. The governmental agency, office or individ-ual responsible for approving equipment, an installation or a procedure. 3.6 Barrier

20、. A material object that separates, keeps apart or demarcates in a conspicuous manner such as cones, a warning sign or tape. 3.7 Blast Area. The area in which concussion (shock wave), flying material or gases from an explosion may cause injury to persons. Copyright American Society of Safety Enginee

21、rs Provided by IHS under license with ASSE/SAFE Licensee=CHINA STDS INFORMATION CENTER - avada indx app by/5954931001, User=ZhaoNot for Resale, 05/02/2012 00:36:12 MDTNo reproduction or networking permitted without license from IHS-,-,-AMERICAN NATIONAL STANDARD A10.7-2011 13 3.8 Blast Preparation.

22、Drilling, hole inspection, loading explosive charges, installing systems for initiation and confinement of the blast. 3.9 Blast Site. The area where explosive materials are handled during the loading of a borehole, including 50 feet (15.2m) in all directions from the perimeter formed by loaded holes

23、. A minimum of 30 feet (9.1m) may replace the 50 feet (15.2m) requirement if the perimeter for loaded holes is marked and separated from non-blast site areas by a barrier. The 50 feet (15.2m) or 30 feet (9.1m) distance require-ments, as applicable, shall apply in all directions along the full depth

24、of the borehole. In underground operations, at least 15 feet (4.6m) of a solid rib, pillar or broken rock can be substituted for the 50 foot (15.2m) distance. 3.10 Blaster. A qualified individual who assists with the design, loading and firing of a blast. May or may not be licensed according to loca

25、l regulations. May be synonymous with Shot Firer. 3.11 Blaster-in-Charge. The blaster who is in charge of and responsible for the design, loading and firing of a blast at a specific job site. 3.12 Blasting Agent. An explosive material that meets prescribed criteria for insensitivity to initiation. F

26、or storage, CFR Title 27, Part 555, of the Bureau of Alcohol, Tobacco, Firearms and Explosives of the Department of the Justice defines a blasting agent as any material or mixture, consisting of fuel and oxidizer, intended for blasting but not otherwise defined as an explosive. This assumes that the

27、 finished product, as mixed for use or shipment, cannot be detonated by means of a No. 8 test blasting cap when unconfined. For transportation, CFR Title 49, Part 173.50, defines Class 1, Division 1.5 material (blasting agent) as a substance which has mass explosion hazard, but is so insensitive tha

28、t there is very little probability of initiation or of transition from burning to detonation under normal conditions in transport. 3.13 Blasting Cap. See Detonator. 3.14 Bulk-Mix Delivery Equipment. Equipment (usually a motor vehicle with or without mechanical delivery device) that transports explos

29、ive materials in bulk form for mixing, or for loading directly into blast holes, or both. 3.15 Bullet-Resistant Construction. Magazine walls or doors of construction that are resistant to penetration by a bullet of 150-grain M2 ball ammunition of nominal muzzle velocity 2,700 feet per second (840m/s

30、), fired from a .30 caliber rifle at a right angle to the wall or door, from a distance of 100 feet (31m). When a magazine ceiling or roof is required to be bullet-resistant, the ceiling or roof shall be constructed of materials comparable to the side walls or of other materials that will withstand

31、penetration when the bullet described above is fired at an angle of 45 degrees to the surface. Tests to determine bullet-resistance shall be conducted on test panels or empty magazines that will resist penetration of 5 out of 5 shots placed independently of each other in an area at least 3 feet by 3

32、 feet (0.9m x 0.9m). Examples of construction that meet this definition are given in 6.5.1. 3.16 Bullet-Sensitive Explosive Ma-terial. Explosive material that can be detonated by 150-grain M2 ball ammunition of nominal muzzle velocity 2,700 feet per second (840m/s), fired from a .30 caliber rifle fr

33、om a distance of 100 feet (31m) when the test material, at 70 to 75 Fahrenheit (21.1 to 23.9 Celsius), is placed against a backing material of half-inch (1.77cm) steel plate. 3.17 Connecting Wire. Wire used to extend the firing line or leg wires in an electric blasting circuit. Copyright American So

34、ciety of Safety Engineers Provided by IHS under license with ASSE/SAFE Licensee=CHINA STDS INFORMATION CENTER - avada indx app by/5954931001, User=ZhaoNot for Resale, 05/02/2012 00:36:12 MDTNo reproduction or networking permitted without license from IHS-,-,-AMERICAN NATIONAL STANDARD A10.7-2011 14

35、3.18 Conveyance. Any unit for transporting explosives or blasting agents including, but not limited to, trucks, trailers, rail cars, barges and ships. 3.19 Deflagration. An explosive reac-tion such as a rapid combustion that moves through an explosive material at a velocity less than the speed of so

36、und in the material. 3.20 Detonating Cord. A flexible cord, containing a center core of high explosive that can be used to initiate other explosives. 3.21 Detonator. Any device containing any initiating or primary explosive that is used for initiating detonation. A detonator may not contain more tha

37、n 10 grams of total explosives by weight, excluding ignition or delay charges. The term includes, but is not limited to, electric blasting caps of instantaneous and delay types, electronic detonators, blasting caps for use with safety fuses, detonating-cord delay connectors and nonelectric instantan

38、eous and delay blasting caps that use detonating cord, shock tube or any other replacement for electric leg-wires. 3.22 Donor. An exploding charge producing an impulse that impinges upon an “acceptor“ charge. 3.23 Electric Detonator. A detonator designed for, and capable of, initiation by means of a

39、n electric current. 3.24 Electronic Detonator. A detona-tor that utilizes stored electrical energy as a means of powering an electronic timing delay element/module and that provides initiation energy for firing the base charge. Electronic detonators differ from other detonators by utilizing an Integ

40、rated Circuit (IC) or an Application Specific Integrated Circuit (ASIC) to provide millisecond precise timing as well as a level of communication and control over the firing circuit. Unlike an electric detonator, the igniter or firing device inside an electronic detonator is physically separated fro

41、m the leads by a circuit board or electronic assembly. See IME SLP-17 for more information on the differences between electric and electronic detonators. 3.25 Emulsion Explosive. An explo-sive material containing substantial amounts of oxidizers dissolved in water droplets surrounded by an immiscibl

42、e fuel or droplets of an immiscible fuel surrounded by water containing substantial amounts of oxidizer. 3.26 Explosive Materials. These include explosives, blasting agents and detonators. The term includes, but is not limited to, dynamite and other high explosives; slurries, emulsions and water gel

43、s; black powder and pellet powder; initiating explosives; detonators (blasting caps); safety fuses; squibs; detonating cords; igniter cords and igniters. A list of explosive materials determined to be within the coverage of 18 U.S.C. Chapter 40, “Importation, Manufacture, Distribution and Storage of

44、 Explosive Materials,” is issued at least annually by the Director of the Bureau of Alcohol, Tobacco, Firearms and Explosives of the Department of Justice. The U.S. Department of Transportation classification of explosive materials used in commercial blasting operations is not identical to the statu

45、tory definitions of the Organized Crime Control Act of 1970, Title 18 U.S.C., Section 841. To achieve uniformity in transportation, the definitions of the U.S. Department of Transportation in CFR Title 49, Parts 1-999 subdivide these materials as shown in the following table: Copyright American Soci

46、ety of Safety Engineers Provided by IHS under license with ASSE/SAFE Licensee=CHINA STDS INFORMATION CENTER - avada indx app by/5954931001, User=ZhaoNot for Resale, 05/02/2012 00:36:12 MDTNo reproduction or networking permitted without license from IHS-,-,-AMERICAN NATIONAL STANDARD A10.7-2011 15 Ta

47、ble 1 - U.S. Department of Transportation Definitions DIVISION 1.1 Mass exploding (Class A explosives) DIVISION 1.2 Projection Hazard (Class A or Class B explosives) DIVISION 1.3 Fire hazard, minor blast or projection hazard (Class B explosives) DIVISION 1.4 Minor explosion hazard - not mass detonat

48、ing (Class C explosives) DIVISION 1.5 Insensitive explosives. Very little probability of initiation or transition from burning to detonation during transport. (Blasting Agents) 3.27 Explosives. Any chemical com-pound, mixture or device, the primary or common purpose of which is to function by explosion. 3.28 Fire Extinguisher Rating. A rating, set forth in NFPA 10, Portable Fire Extinguishers, which may be identified on an extinguisher by a number indicating relative effectiveness (for example, 5, 20 or 70), followed by a letter indicating the class or classes of fires fo

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1