1、STANDARD FOR SMOKE DETECTORS FOR FIRE ALARMSYSTEMSPrepared and Published by:NATIONALSTANDARDOF CANADACAN/ULC-S529:2016-REV2016(Revision 2016)Approved by:Underwriters Laboratories of Canada (ULC) was established in 1920 byletters patent issued by the Canadian Government. It maintains andoperates labo

2、ratories and certification services for the examination, testingand certification of appliances, equipment, materials, constructions andsystems to determine their relation to life, fire and property hazards aswell providing inspection services.Underwriters Laboratories of Canada is accredited by the

3、 StandardsCouncil of Canada as a Certification Organization, a Testing Organization,and an Inspection Body under the National Standards System of Canada.ULC Standards develops and publishes standards and other relatedpublications for building construction, security and burglar protection,environment

4、al safety, electrical equipment, fire protection equipment, gasand oil equipment, thermal insulation products, materials and systems,energy use in the built environment and electrical utility safety.ULC Standards is a not-for-profit organization and is accredited by theStandards Council of Canada as

5、 a Standards Development Organization.National Standards of Canada developed by ULC Standards conform tothe criteria and procedures established by the Standards Council ofCanada. Such standards are prepared using the consensus principle byindividuals who provide a balanced representation of interest

6、s relevant tothe subject area on a national basis.ULC is represented across Canada as well as many countries worldwide.For further information on ULC services, please contact:Customer Service: 1-866-937-3852National Standard of CanadaA National Standard of Canada is a standard developed by an SCC-ac

7、credited Standards Development Organization (SDO), and approvedby the Standards Council of Canada (SCC), in accordance with SCCs:Requirements and Guidance-Accreditation for Standards DevelopmentOrganizations, and Requirements and Guidance-Approval of NationalStandards of Canada Designation.More info

8、rmation on National Standard requirements can be found atwww.scc.ca. An SCC-approved standard reflects the consensus of anumber of experts whose collective interests provide, to the greatestpracticable extent, a balance of representation of affected stakeholders.National Standards of Canada are inte

9、nded to make a significant andtimely contribution to the Canadian interest.SCC is a Crown corporation within the portfolio of Industry Canada. Withthe goal of enhancing Canadas economic competitiveness and socialwell-being, SCC leads and facilitates the development and use ofnational and internation

10、al standards. SCC also coordinates Canadianparticipation in standards development, and identifies strategies toadvance Canadian standardization efforts. Accreditation services areprovided by SCC to various customers, including product certifiers,testing laboratories, and standards development organi

11、zations. A list ofSCC programs and accredited bodies is publicly available atwww.scc.ca.Users should always obtain the latest edition of a National Standard ofCanada from the standards development organization responsible for itspublication, as these documents are subject to periodic review.CORPORAT

12、E HEADQUARTERSUnderwriters Laboratories of Canada7 Underwriters RoadToronto, Ontario M1R 3A9Telephone: (416) 757-3611Fax: (416) 757-9540REGIONAL OFFICESPACIFIC OFFICE13775 Commerce Parkway, Suite 130Richmond, British Columbia V6V 2V4Telephone: (604) 214-9555Fax: (604) 214-9550EASTERN OFFICE6505, Rte

13、 Transcanadienne, Suite 330St-Laurent, Qubec H4T 1S3Telephone: (514) 363-5941Fax: (514) 363-7014For further information on ULC standards, please contact:ULC STANDARDS171 Nepean Street, Suite 400Ottawa, Ontario K2P 0B4Telephone: (613) 755-2729Fax: (613) 231-5977E-mail: customerserviceulc.caWeb site:

14、www.ulc.caThe intended primary application of this standard is stated in its scope. It is important to note that it remains the responsibility of the user of thestandard to judge its suitability for this particular application.Copies of this National Standard of Canada may be ordered from ULC Standa

15、rds.CETTE NORME NATIONALE DU CANADA EST DISPONIBLE EN VERSIONS FRANAISE ET ANGLAISEPrepared by:ULC StandardsCAN/ULC-S529: 2016-REV2016Fourth EditionUnderwriters Laboratories Inc.ANSI/UL 268Seventh EditionStandard for Smoke Detectors for Fire Alarm SystemsJanuary 11, 2016ANSI/UL 268-2016Approved byCo

16、mmitment for AmendmentsThis Standard is issued jointly by Underwriters Laboratories Inc. (UL) and ULC Standards.Amendments to this Standard will be made only after processing according to the Standards writingprocedures by UL and ULC Standards.UL and ULC Standards are separate and independent entiti

17、es and each is solely responsible for itsoperations and business activities. The UL trade names and trademarks depicted in this document arethe sole property of Underwriters Laboratories Inc. The ULC Standards trade names and trademarksdepicted in this document are the sole property of ULC Standards

18、.ISSN 0317-526X Copyright 2016 ULC StandardsAll rights reserved.No part of this publication may be reproduced in any form, in an electronic retrieval system orotherwise, whatsoever without the prior permission of the publisher.In Canada, written comments are to be sent to the ULC Standards, 400 - 17

19、1 Nepean Street, Ottawa,Ontario K2P 0B4. Proposals should be submitted on a Standards Revision Request Form availablefrom ULC Standards.Copyright 2016 Underwriters Laboratories Inc.ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standardshould be altered in

20、 any way. All of ULs Standards and all copyrights, ownerships, and rights regardingthose Standards shall remain the sole and exclusive property of UL.This ANSI/UL Standard for Safety consists of the Seventh Edition including revisions through July 15,2016.The most recent designation of ANSI/UL 268 a

21、s an American National Standard (ANSI) occurred onJuly 15, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, TitlePage (front and back), or the Preface.Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time.Proposals sh

22、ould be submitted via a Proposal Request in ULs On-Line Collaborative StandardsDevelopment System (CSDS) at http:/.To purchase UL Standards, visit Comm 2000 at http:/m- call toll-free 1-888-853-3503.ULC PreambleInternational Classification for Standards (ICS): 13.220.20; 13.320This Standard has been

23、 developed in compliance with the requirements of SCC for accreditation of aStandards Development Organization.This Fourth Edition National Standard of Canada is based on, and now supersedes, the Third Edition.Attention is drawn to the possibility that some of the elements of this Canadian standard

24、may be thesubject of patents rights. ULC Standards shall not be held responsible for identifying any or all suchpatents rights.Requests for interpretation of this Standard should be sent to ULC Standards. The requests should beworded in such a manner as to permit a “yes” or “no” answer based on the

25、literal text of the requirementconcerned.The review and action to revise or reaffirm this Standard will not exceed 5 years from the date ofpublication, unless the Standard is identified as fitting within a stabilized category, whereby the review willcommence within the appropriate time frame set out

26、 by ULC StandardsThis Standard is intended to be used for conformity assessment.The review and action to revise or reaffirm this Standard will not exceed 5 years from the date ofpublication, unless the Standard is identified as fitting within a stabilized category, whereby the review willcommence wi

27、thin the appropriate time frame set out by ULC Standards.ULC STANDARDS COMMITTEE ON FIRE ALARM AND LIFE SAFETY EQUIPMENT AND SYSTEMSNAME AFFILIATION REGION CATEGORYA.M. Leber (Chair) Leber/Rubes Inc Canada General InterestS. Ames System Sensor Canada Canada ProducerM. Anderson Chief Electrical Inspe

28、ctors Association Canada RegulatorsD. Boynowski Siemens Building Technologies, Ltd. Canada ProducerP. Clarke Canadian Forces Fire Marshals Office Canada UserB. Cran Consumers Association of Canada Canada UserS. Crosby Randal Brown and the ULC TechnicalCommittee on Fire Alarm and Life Safety Equipmen

29、t and Systems. The efforts and support of the NEMATechnical Harmonization Committee, the UL Standards Technical Panel, and the ULC TechnicalCommittee are gratefully acknowledged.Only metric SI units of measurement are used in this Standard. If a value for measurement is followed bya value in other u

30、nits in parentheses, the second value may be approximate. The first stated value is therequirement.In Canada, there are two official languages, English and French. All safety warnings must be in Frenchand English. Attention is drawn to the possibility that some Canadian authorities may require addit

31、ionalmarkings and/or installation instructions to be in both official languages.This standard has been approved as a National Standard of Canada by the Standards Council of Canada.This standard has been approved by the American National Standards Institute as an American NationalStandard.Annexes A,

32、B, E, F and H are identified as informative and are for informational purposes only. AnnexesC c) National Building Code of Canada; andd) National Fire Code of Canada.1.2 A smoke detector (e.g. ionization-type, photoelectric-type, smoke detector with supplementary heatdetection type, combination smok

33、e type, multi-criteria type) as covered by this Standard consists of anassembly of electrical components arranged to detect one or more products of combustion. At a minimumthe detector shall contain a smoke (particulate) sensor. The products of combustion may consist of visibleas well as invisible s

34、moke particles, gases, heat, radiant energy, and water vapor The detector includesprovision for the connection to a source of power, signaling, and optional remote control circuits.Additional functionality, such as a heat detector, heat sensor, or audible signaling appliance/device, ispermitted to b

35、e incorporated as part of the smoke detector assembly.1.3 This standard covers the following types of detectors:a) Detectors intended for open area protection and for connection to a compatible power supplyor control unit for operation as part of a fire alarm system.b) Detectors intended solely for

36、control of releasing devices such as electromagnetic doorholders, fire dampers or smoke dampers.c) Detectors intended for both applications described in (a) and (b) above, andd) In Canada, duct detectors.1.4 This standard does not cover the following:In the United States (a g):a) Control units to wh

37、ich the detectors are intended to be connected that are coveredby the Standard for Control Units for Fire-Protective Signaling Systems, UL 864;b) Self-contained single and multiple station smoke alarms, not intended for connectionto a system control unit, that are covered by the Standard for Single

38、and MultipleStation Smoke Alarms, UL 217;JANUARY 11, 2016CAN/ULC-S529: 2016-REV2016 ANSI/UL 26816c) A heat detector incorporated as a part of a smoke detector assembly, and coveredby the Standard for Heat Detectors for Fire Protective Signaling Systems, UL 521;except for the requirements of the Fire

39、 Test (Heat Detector) and/or when part of a multi-criteria smoke detector;d) A gas and vapor detector or sensor incorporated as a part of a smoke detectorassembly, and covered by the Standard for Gas and Vapor Detectors and Sensors, UL2075, except when part of a multi-criteria smoke detector;e) Fire

40、 tests for smoke detectors integral with combination door closers and holdersthat are covered by the Standard for Door Closers-Holders, With or Without IntegralSmoke Detectors, UL 228;f) Commercial-residential detectors not intended for connection to a system control unitthat are covered by the Stan

41、dard for Smoke Detector Monitors and Accessories forIndividual Living Units of Multifamily Residences and Hotel/Motel Rooms, UL 1730;g) Detectors for monitoring the smoke density within flues or stacks;In Canada (h m):h) Control units that are covered by the Standard for Control Units for Fire Alarm

42、Systems, CAN/ULC-S527;i) Self-contained single and multiple station smoke alarms that are covered by theStandard For Smoke Alarms, CAN/ULC-S531;j) A heat detector incorporated as a part of a smoke detector assembly, and coveredby the Standard For Heat Actuated Fire Detectors for Fire Alarm Systems,

43、CAN/ULC-S530 and/or when part of a multi-criteria smoke detector;k) Fire tests for smoke detectors integral with combination door closers and holdersthat are covered by the Standard for Door Closers and Holders, ULC/ORD-C228;l) Detectors for monitoring the smoke density within flues or stacks; andm)

44、 A residential CO alarming device incorporated as a part of a smoke detectorassembly, and covered by the CAN/CSA 6.19, Standards for Residential CO AlarmingDevices, except when part of a multi-criteria smoke detector.1.5 These requirements also cover all remote accessories that are intended to be co

45、nnected to a smokedetector.JANUARY 11, 2016 CAN/ULC-S529: 2016-REV2016 ANSI/UL 268 172 General2.1 Assembly2.1.1 A detector shall be so constructed that it will be reliable and sufficiently durable for its intendedinstallation and use.2.1.2 A component of a detector shall comply with the requirements

46、 for that component, except that suchrequirements may be modified for the particular application.2.2 Components2.2.1 Except as indicated in 2.2.2, a component of a product covered by this standard shall comply withthe requirements for that component. See Annex E for a list of standards covering comp

47、onents generallyused in the products covered by this standard.2.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this statement orb) Is superseded by a requirem

48、ent in this standard.2.2.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.2.4 Specific components are incomplete in construction features or restricted in performancecapabilities. Such components are intended for use only under limited conditi

49、ons, such as certaintemperatures not exceeding specified limits, and shall be used only under those specific conditions.2.3 Units of measurement2.3.1 The metric unit shall be designated as the official unit for purposes of this standard. Where valuesof measurement are specified in both SI and English units, either unit is used. In cases of dispute, themetric unit shall be used.JANUARY 11, 2016CAN/ULC-S529: 2016-REV2016 ANSI/UL 268182.4 Reference publications2.4.1 Where reference is made to other publications, such refe

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1