1、EIA STANDARD ANSIIEIA-364-09C-1999 (R2006) Approved: April 23,1999 Reaffirmed: March 27,2006 TP-09C Durability Test Procedure for Electrical Connectors and Contacts EIA-3 64-09C (Revision of EIA-364-09B) JUNE 1999 ELECTRONIC INDUSTRIES ALLIANCE Electronic Components, Assemblies, Equipment securing o

2、f test fixture shaii not affect seif-agnment. Mer mounting, fbliy mate and unmate for the number of cycles specied in the referencing document. 4.2 Cycle rate Unless otherwise specied in the referencing document, the cycle rate per hour sha be: - Automatic equipment: 500 f 50 -Manual rnating/unmatin

3、g: 300 maximum - Automatic, Circular Connectors: 250 to 300 Copyright Electronic Components, Assemblies 8ect subsequent results. 4.5 Measurements 4.5.1 Mating and unmathg forces, contact resistance, shell resistance, insulation resistance, dielectric withstanding voltage, contact retention, and seal

4、ing tests are examples of measurements that may be made prior to, during or after testing and that would show the effects of durability. 4.5.2 The connectors or contacts shall be examined to determine the effects of durabiiity cycling that would include the following: 4.5.2.1 Wear on coupling device

5、. 4.5.2.2 Loose or worn rivets; where applicable. 4.5.2.3 Uneven wear, galling, removal of plating on contacts and shells. 4.5.2.4 Free metal chips on face of inserts. 4.5.2.5 Displaced, bent or broken contacts. 4.5.2.6 Inability to properly mate and unmate. 4.5.2.7 Pierced resilient inserts and bro

6、ken or chipped hard dielectrics. 4.5.2.8 Mechanical operational characteristics, including effectiveness of keys and polarizing systems. Copyright Electronic Components, Assemblies visual examination 6.6 Operator name and date of test Copyright Electronic Components, Assemblies & Materials Associati

7、on Provided by IHS under license with ECA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-EIA-364-09C Page 5 si& 2 -3 4 - 3.56t 03 (0.140+ 0.010) 31.75 (1.250) minimum - 3 c f 0.003 (O.Ooo1) 1.778 (0.0700 2.616 (0.1030) 3.429 (0.1350) 1s- Entire surface O. 1 micm S

8、tyle 06 10 (4 microindi) both sidcc u 9.55 (0.375) from cnd (m note 3) 953 (0375) 1.70 (O.OU) mdilBtyppcal 02.5 t 0.13 .OiOt 0.005) 034 (0.0135) typMI - C(seetc4) -c) A i 0.25 (0.010) 27.18 (1.070) 41.88 (1.649) 12 15 18 22 28 30 36 43 51.08 (2.011) 62.87 (2.475) 74.73 (2.942) 90.55 (3.565) 114.35 (

9、4.502) 122.22 (4.812) 120.57 (4.747) 171.98 (6.771) NOTES i Dimensions in parentheses are in inches. 2 Unless otherwise specied, tolerance is f O. 13 mm for two place metric 3 Only the working surfaces designated 4 shall be finished. 4 0.05 mm (0.002 in) TIR warpage permitted for full length of dime

10、nsion A 5 inch equivalents are based upon 25,4 mm = 1 .o0 in. dimensions and (0.005 in) for three place inch dimensions. Figure 1 - Test blade Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Not for ResaleNo reproduction or networking permit

11、ted without license from IHS-,-,-3%-3 64-09C Page A-1 Annex A A Normative A. 1 Acceptable criteria Acceptable criteria shall be established in terms of one, or any combination, of the following: A. 1.1 Totai mating and mating force. A. 1.2 Individual contact separation and engaging force. A. i .3 Ma

12、ximum allowable change in contact resistcuice. NOTE - Not applicable to gage cycled specimens. A. 1.4 Degrees and criticality of wear or component damage resulting fiom this and succeeding environmental exposure tests. Copyright Electronic Components, Assemblies & Materials Association Provided by I

13、HS under license with ECA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-EU Document Improvement Proposal Signature: If in the review or use of this document, a potential change is made evident for safety, health or technical reasons, please fill in the appropriat

14、e information below and mail or FAX to: Date: Electronic Industries Alliance Engineering Department - Publications Office 2500 Wilson Blvd. Arlington, VA 22201 FAX: (703) 907-7501 Document No. Submitters Name: Address: Document Title: Telephone No.: FAXNo.: e-mail: Urgency of Change: Immediate: 0 At

15、 next revision: 0 Problem Area: a. Clause Number and/or Drawing: b. Recommended Changes: c. Reason/Rationale for Recommendation: Additional Remarks: Chairman: Date comments forwarded to Committee Chairman: Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under lice

16、nse with ECA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright Elec

17、tronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Electronic Industries Alliance Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1