1、 . fIA TIA-455-i5 91 W 3234600 0076902 2 W ANSI/ EIAI TIA-455-18 5-1991 APPROVED: May 3, 1991 rn a) I rn rn * I I- r a a - - w EIA/TIA STANDARD FOTP-185 Strength of Coupling Mechanism for Fiber Optic Interconnecting Devices MAY 1991 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT ,:ET= INDU

2、STRY ASSClATMN Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTICE EIA/TIA Engineering Standards and Publications are designed to serve the public interest through eliminatin

3、g misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any r

4、espect preclude any member or nonmember of EIA/TIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other Phan EIA/TIA members, whether the standard is to be used

5、 either domestically or internationally. Recornmended Standards and Publications are adopted by EIA/TIA without regard to whether their adoption may involve patents on articles, materials, or processes. By such action, EIA/TIA does not assume any liability to any patent owner, nor does it assume any

6、 obligation whatever to parties adopting the Recommended Standard or Publication. This EIA/TIA Standard ia considered to have International Standardization implication, but the International Electroteehnical Csmmission activity has not progressed to the point where a valid comparison between the EIA

7、/TIA Standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine

8、 the applicability of regulatory limitations before its use. Published by ELECTRONIC I NDUSTRI ES ASSOCIATION Engineering Department 2001 Pennsylvania Ave., N.W. Washington, D.C. 20006 PRICE: Please refer to the current Catalog of EIA & JEDEC STANDARDS & ENGINEERING PUBLICATIIQNS 8Y Call th EM STAND

9、ARDS SALES DEPARTMENT (%82/457-4966) TELECOMWIIINICATIONS INDUSTRY ASSOCIATION 1991 All rights reserved Printed in U.S.A. Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-I Copyr

10、ight Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EIA TIA-455-185 71 = 3234600 0076705 EIA/TIA-455-185 Page 1 FOTP-185 STRENGTH OF COUPLING MECHANISM FOR FIBER OPTIC INTERCONNECTING DE

11、VICES (From EIA Standards Proposal No. 2238, formulated under the cognizance of TIA FO-6.3, Subcommittee on Fiber Optic Interconnecting Devices, and TIA FO-6.4, Subcommittee on Fiber Optic Test Methods and Instrumentation.) This FOTP is part of the series of test procedures included within Recommend

12、ed Standard EIA/TIA-455. . 1. INTRODUCTION The intent of this procedure is to assure that the coupling mechanism of a connector set or connector-device combination will withstand the axial loads likely to be applied during normal service. 2. APPLICABLE DOCUMENTS Test or inspection requirements may i

13、nclude, but are not limited to, the following references: EIA/TIA-455A1 “Standard Test Procedures for Fiber Optic Fibers, Cables, Transducers, Sensors, Connecting and Terminating Devices, and Other Fiber Optic Components“ FO TP- 13(EIA-455- 13) “Visual and Mec hani cal Insp e c t ion of Fiber, Cable

14、s, Connectors and/or Other Fiber Optic Devices“ IEC-874- 1 (3r d-Ed.)2 “Connectors for Optical Fibers and Cables, Part 1, Generic Specific at ion“ 1. In process of preparation. Pending publication of this revision, use EIA/RS-455, 2, In process of preparation. Pending publicatioq of this revision, u

15、se EC SC86BCOG9 dated 22 August 1989. Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-i EIA TIA-455-185 91 m 3234600 0076706 T m EJA/TU-455-185 Page 2 3. APPARATUS The assembled

16、 test apparatus shall be capable of applying an axial load between the connector adapter or device adapter and cap or coupling nut. An example of a test apparatus is shown in Figure 1. All or some of the following apparatus components are required. 3.1 applying the specified force at the specified r

17、ate. FORCE GENERATOR. Use any suitable device that is capable of smoothly 3.2 generator to the connector or device adapter cap or coupling nut. CLAMPING DEVICE. Use a suitable clamping device to couple the force 3.3 specimen by its normal mounting means. SPECIMEN MOUNT. Use a specimen mount which wi

18、ll permit mounting the 3.4 in accordance with the manufacturers instructions. TORQUE WRENCH. Use a torque wrench to assemble screw-type connectors 4. SAMPLING AND SPECIMENS 4.1 SAMPLING. Unless otherwise specified in the Detail Specification, select the test specimens randomly from the lot(s) being

19、tested and according to the schedule in the Detail Specification. 4.2 SPECIMENS. Unless otherwise specified in the Detail Specification, each test specimen shall be one of the following: (a) a plug-adapter-plug combination for connectors, or (b) a plug-adapter for device adapters. Unless otherwise s

20、pecified, each specimen shall be assembled according to the manufacturers instructions. The inclusion of fiber and cable is optional. 5. PROCEDURE 5.1 PREPARE SPECIMENS. Mate each specimen set according to the manufacturers instructions. For screw-type couplings, use a torque wrench to ensure that c

21、ouplings are tightened in accordance with the manufacturers specification. 5.2 PRECONDITIONING. Unless otherwise specified in the Detail Specification, precondition each prepared specimen for a period of 4 hours at the standard test conditions specified in ELAITIA-455A. Copyright Telecommunications

22、Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EIA TIA-455-165 91 m 323Yb00 007b907 1 m -ii EIA/TIA.-455-185 Page 3 5.3 SPECIMEN MOUNTING. Securely mount one portion of the specimen (plug, adapter, or devi

23、ce adapter) to the base of the apparatus. Fix the other specimen part to be tested (usually the coupling nut) to the moveable portion of the force generator. 5.4 TENSILE LOADING. Smoothly apply the tensile force to the connector at the specified rate and up to the specified maximum value. Unless oth

24、erwise specified, maintain the load for a minimum period of 15 seconds. 5.5 POST TEST EXAMINATION. Remove the tensile load and remove the test specimen from the mounting. Uncouple the specimen. Unless otherwise specified, -. visually examine specimens and their component parts in accordance with the

25、 requirements of FOTP-13. Check for evidence of cracking, permanent deformation or other damage which might impair its function, and any other pass/fail criteria that may be specified in the Detail Specification. 8. CALCULATIONS OR INTERPRETATION OF RESULTS (Not Required) 7. DOCUMENTATION 7.1 Report

26、 the following information for each test: 7.1.1 Date of test, 7.1.2 7.1.3 Test results, 7.1.4 Deviations from prescribed test procedure. 7.2 United States military applications require that the following information also be reported for each test. For other (non-military) applications this informati

27、on need not be reported, but shall be available for review upon request: 7.2.1 Test personnel, 7.2.2 Brief description of test apparatus and date of latest calibration, 7.2.3 Description of test sample. Specimen part number and name, Copyright Telecommunications Industry Association Provided by IHS

28、under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EIA TIA-455-1B5 91 3234b00 0076908 3 EU/ TIA-455- 185 Page 4 8. SPECIFICATION INFORMATION The following information shall be specified in the Detail Specification: 8.1 Acceptance or failure crite

29、ria, 8.2 Preconditioning, if other than as specified in 5.1, 8.3 8.4 8.5 Axial load to be applied, Rate of application of load, Duration force is to be maintained, if other than 15 seconds. Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo repro

30、duction or networking permitted without license from IHS-,-,-EIA TIA-455-185 91 3234600 0076909 5 EIA/TIA-455- 185 Page 5 DIRECTION OF FORCE I SPECIMEN MOUNT, FORCE GAUGE MPING rl- DEVICE f I I ADAPTER d FORCE GENERATOR EXAMPLE OF COUPLING i“ APPARATUS FPGURE 1 Copyright Telecommunications Industry

31、Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EIA TIA-455-185 71 3234600 0076910 1 * 9. EM/ TIA-455-1 85 Page APPENDIX COMPARISON BETWEEN THIS FOTP AND IEC OR CCITT REQUIREMENTS (Nonmandatory Information) Al. lEC

32、Reference is made to LEC-874-1, Third Edition3, “Connectors for optical fibres and cables, Generic specification.“ (Now in preparation) Clause 4.5.6, “Strength of coupling mechanism,“ of IEC-874-1, Third Edition, defines a mechanical test and measurement procedure which, insofar as can be determined

33、, is the same as the test described in FOTP-185. Also, it should be noted that a sample apparatus is included in the FOTP but not in the IEC document. A2. CCITT There are no references to any test equivalent to this FOTP known to exist in CCITT documents. 3. In process of preparation. Pending publication of this revision the test can be found in Clause 4.5.U of EC SC86BCOG9. Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1