1、 STANDARD FOR OPTICAL FIBER OUTSIDE PLANT MICRODUCT CABLES ANSI/ICEA S-122-744-2016 2016 by INSULATED CABLE ENGINEERS ASSOCIATION, Inc. ANSI/ICEA S-122-744-2016 STANDARD FOR OPTICAL FIBER OUTSIDE PLANT MICRODUCT CABLES Publication S-122-744 First Edition July 22, 2016 Published By Insulated Cable En

2、gineers Association, Inc. (ICEA) Approved July 22, 2016, by INSULATED CABLE ENGINEERS ASSOCIATION, Inc. ANSI version: Approval January 6, 2017, by ANSI ASC C-8 AMERICAN NATIONAL STANDARDS INSTITUTE Copyrighted by the ICEA Contents may not be reproduced in any form without permission of the INSULATE

3、D CABLE ENGINEERS ASSOCIATION, INC. Copies of this publication may be ordered online or by contacting: IHS 15 Inverness Way East Englewood, CO 80113-5776 USA Telephone: (800) 854-7179 NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of pers

4、ons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. The Insulated Cable Engineers Association, Inc. (ICEA) standards and g

5、uideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together persons who have an interest in the topic covered by this publication. While ICEA administers the process and establishes rule

6、s to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. ICEA disclaims liability for personal injury, property,

7、or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. ICEA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy o

8、r completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. ICEA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by

9、virtue of this standard or guide. In publishing and making this document available, ICEA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is ICEA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this d

10、ocument should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other s

11、ources, which the user may wish to consult for additional views or information not covered by this publication. ICEA has no power, nor does it undertake to police or enforce compliance with the contents of this document. ICEA does not certify, test, or inspect products, designs, or installations for

12、 safety or health purposes. Any certification or other statement of compliance with any health or safety-related information in this document shall not be attributable to ICEA and is solely the responsibility of the certifier or maker of the statement. This page intentionally blank. FOREWORD ICEA St

13、andards are adopted in the public interest and are designed to eliminate misunderstanding between the manufacturer and user and to assist the user in selecting and obtaining proper products for his particular need. Existence of an ICEA Standard does not in any respect preclude the manufacture or use

14、 of products not conforming to the Standard. The user of this Standard is cautioned to observe any applicable health or safety regulations and rules relative to the manufacture and use of cable made in conformity with this Standard. This Standard hereafter assumes that only properly trained personne

15、l using suitable equipment will perform manufacture, testing, installation, and maintenance of cables defined by this Standard. Requests for interpretation of this ICEA Standard must be submitted in writing (hard copy, email, or fax) to the Insulated Cable Engineers Association to the ICEA Secretary

16、. The mailing address of ICEA Headquarters and a Contact link are shown on the ICEA web site . An official written interpretation will be provided. The members of the ICEA Communications Cable Section, Working Group 744, who participated in this project, were: Jim Register, Chairman and Editor G. Do

17、rna R. Gould N. Hatch M. D. Kinard J. Lichtenwalner J. Mohler D. Parke M. Rainville J. Ryan T. Schmalzigaug R. Stanko R. Stevens D. Taylor T. West H. Toland P. VanVickle This page intentionally blank. CONTENTS SECTION PAGE PART 1 INTRODUCTION 1 1.1 Scope 1 1.2 General . 3 1.3 Units 3 1.4 Definitions

18、 . 3 1.5 References . 5 1.6 Information to be Supplied by the User 5 1.7 Modification of this Standard 5 1.8 Quality Assurance . 5 1.9 Safety Considerations 5 PART 2 OPTICAL FIBERS 7 2.1 General . 7 2.2 Optical Fiber Classes 7 2.3 Optical Fiber Requirements 7 2.4 Optical Fiber Coating and Requiremen

19、ts . 7 PART 3 OPTICAL FIBER CORE UNITS 11 3.1 General . 11 3.2 Loose Buffer Tubes 11 3.3 Optical Fiber Bundles . 12 3.4 Optical Fiber Ribbons . 12 3.5 Tight Buffers . 13 PART 4 CABLE AND COMPONENT ASSEMBLY AND IDENTIFICATION 15 4.1 Cabling of Multi-Fiber and Composite Optical Cables . 15 4.2 Identif

20、ication of Fibers within a Unit 15 4.3 Identification of Units within a Cable . 15 4.4 Strength Members 17 4.5 Assembly of Cables 17 4.6 Filling and Flooding Material . 17 CONTENTS (cont.) SECTION PAGE PART 5 COVERINGS 18 5.1 Binders 18 5.2 Core Wrap 18 5.3 Jackets . 18 5.4 Jacket Repairs 19 5.5 Rip

21、cords 19 PART 6 OTHER REQUIREMENTS 20 6.1 Identification and Date Markings 20 6.2 Optical Cable Identification and Other Markings 20 6.3 Length Marking . 20 6.4 Cable Remarking 21 6.5 Packaging, Packing, and Package Marking . 21 PART 7 TESTING, TEST METHODS, AND REQUIREMENTS 23 7.1 Testing 23 7.2 Ex

22、tent of Testing . 23 7.3 Standard Test Conditions . 23 7.4 Electrical Testing of Conductive Materials . 24 7.5 Construction, Color Code, and Identification 24 7.6 Environmental Stress Crack Resistance Test 24 7.7 Verification of Cable Length and Marking Accuracy 25 7.8 Weathering Test . 25 7.9 Cable

23、 and Component Dimensions 26 7.10 Ribbon Dimensions 27 7.11 Ribbon Twist Test . 28 7.12 Ribbon Residual Twist Test 28 7.13 Ribbon Separability Test 29 7.14 Ripcord Functional Test 30 7.15 Material Compatibility and Cable Aging Test . 30 7.16 Tight Buffer Strippability Test . 32 CONTENTS (cont.) SECT

24、ION PAGE Part 7: (Continued) 7.17 Cable Low Temperature Bend Test . 32 7.18 Compound Flow (Drip) Test for Filled Cable 33 7.19 Cable Temperature Cycling Test 34 7.20 Cable Aging Test 34 7.21 Cyclic Flexing Test 35 7.22 Water Penetration Test . 35 7.23 Cable Impact Test . 36 7.24 Cable Tensile Loadin

25、g and Fiber Strain Test . 36 7.25 Cable Compression Loading Test 38 7.26 Cable Twist Test . 39 7.27 Mid Span Buffer Tube Storage . 39 7.28 Oxidative Induction Time, OIT 40 7.29 Cable Kink Test 41 7.30 Buffer Tube Kink Test . 41 PART 8 FINISHED CABLE OPTICAL PERFORMANCE REQUIREMENTS 43 8.1 Optical Pe

26、rformance . 43 8.2 Attenuation Coefficient 44 8.3 Multimode Optical Bandwidth . 45 8.4 Optical Point Discontinuities . 45 8.5 Cable Cutoff Wavelength (Single-Mode Fibers Only) 46 8.6 Polarization Mode Dispersion (Single-Mode Fibers Only) . 46 PART 9 REFERENCES 48 ANNEXES Annex A (Informative) Sugges

27、ted Information for a Purchase Document 52 Annex B (Normative) 1625 nm Cabled Fiber Performance Requirements . 54 Annex C (Informative) Telecommunications Cable Standards . 55 CONTENTS (cont.) SECTION PAGE FIGURES Figure 7.1 Ribbon dimensional parameters . 27 Figure 7.2 Ribbon preparation . 29 Figur

28、e 7.3 Ribbon separation. 30 TABLES PAGE Table 1.1 Cable normal temperature ranges 2 Table 2.1 Multimode optical fiber specification requirements. 8 Table 2.2 Single-mode optical fiber specification requirements . 9 Table 2.3 Fiber Bend characteristics of G.657 single-mode fiber (informative) . 9 Tab

29、le 4.1 Individual fiber, unit, and group identification . 16 Table 7.1 Maximum dimensions of optical fiber ribbons 27 Table 8.1 Attenuation coefficient performance requirements . 43 Table 8.2 Multimode bandwidth coefficient performance requirements . 43 Table 8.3 Point discontinuity acceptance crite

30、ria . 44 Table 8.4 Optical attenuation measurement methods . 44 Table 8.5 Multimode optical bandwidth measurement methods 45 Table B.1 Acceptance criteria for L-Band operation 54 This page intentionally blank. ANSI/ICEA S-122-744-2016 1 PART 1 INTRODUCTION 1.1 Scope 1.1.1 Products This Standard cove

31、rs performance requirements for microduct optical fiber outside plant cables intended for installation in microducts, typically by blowing in using commercially available equipment intended for this application. Products covered by this Standard are intended only for operation under conditions norma

32、lly found in outside plant communication systems. Typically, these products are installed in protected ducts but may be also run for short distances in both exposed areas and in concealed areas (such as handholes), with or without external protection. Due to the thinner jacket usually associated wit

33、h microduct cables, they typically do not have the jacket durability to be pulled into conduit for long distances even at or below the rated tensile strength. Additionally, the impact resistance, compression resistance and tensile strength requirements for cables covered by this Standard may be sign

34、ificantly lower than those for conventional outside plant cables covered by ICEA-640. Therefore, installation of cables covered by this Standard by techniques such as capstan pulling, aerial lashing, trenching, and direct burial is not recommended. 1.1.2 Applications Space Products covered by this S

35、tandard are intended for operation only under conditions normally found in communications systems. These products normally convey communications signals (voice, video, and data) including but not limited to point-to-point or point-to-multipoint installations. Products covered by this Standard may be

36、 factory terminated with connectors or splicing modules. 1.1.3 Temperature Ranges The normal temperature ranges for cables covered by this Standard are given in Table 1.1. Two temperature performance levels are specified for this Standard. Standard temperature performance - This level is considered

37、to be in line with normal outside plant performance levels. This category will ensure performance in scenarios that include transitions between unconnected microduct systems or between a microduct system and some other protective structure, such as a conduit or tray. ANSI/ICEA S-122-744-2016 2 Moder

38、ate temperature performance This level is characterized for installation in moderate climates or when the cable will not be exposed to short transitions below -30 C (-22 F). If “Moderate Temperature Performance” is specified, the performance level should be clearly stated. This may be done using pro

39、duct specification sheets, customer quotations, or similar means. Table 1.1 - Cable normal temperature ranges Standard Temperature Performance C (F) Operation -40 to +70 (-40 to +158) Storage and Shipping -40 to +70 (-40 to +158) Installation -30 to +60 (-22 to +140) Moderate Temperature Performance

40、 C (F) Operation -30 to +60 (-22 to +140) Storage and Shipping -30 to +60 (-22 to +140) Installation -10 to +50 (+14 to +122) 1.1.4 Tensile Rating The minimum tensile rating for cables covered by this Standard is based on cable weight and is equivalent to the force exerted by the weight of 1,000 m o

41、f cable. While microduct cable should be blown into duct instead of pulled, a tensile strength is specified to provide durability and handling robustness. 1.1.5 Minimum Bend Diameter The standard minimum bend diameters for cables covered by this Standard are: Residual Condition (Installed): 20X Cabl

42、e OD, or 30X for ribbon cables ( 216 fibers) Loaded Condition (During Installation): 40X Cable OD For very small cables, such as those installed in miniature ducts, manufacturers may specify a fixed cable minimum bend diameter (e.g., 300 mm) that is independent of the cable outer diameter (OD). ANSI

43、/ICEA S-122-744-2016 3 1.2 General This Standard is so arranged that cables may be selected from numerous constructions covering a broad range of installation and service conditions. Parts 2 to 5 cover the major components and assembly of the cables: Parts 2, 3, and 4 covers assembly, cabling, and i

44、dentification of the individual optical fibers and conductors. Part 5 describes coverings, such as binders, wraps, metallic coverings, and jacketing of the optical cable. Part 6 provides other pertinent requirements not otherwise addressed by Parts 1 through 5 or by Part 7 of this Standard. Part 7 c

45、ontains the test methods and requirements applicable to completed cables and component parts. If there is a conflict between Parts 1 through 6 and Part 7, the provisions of Part 7 apply. Part 8 contains routinely specified optical performance, requirements, and test methods for finished cables. Part

46、 9 contains cross-references to other standards and publications. Annex A (Informative) contains information for users on ordering the types of cable products covered by this Standard. Annex C (Informative) contains information on other ICEA Standards. 1.3 Units In this Standard, metric (SI) units a

47、re used. Their approximate U.S. customary units are included where appropriate. Where approximate equivalents in alternate systems are included, they are provided for information only and in most cases are rounded off for measurement convenience. Unless otherwise specified, the Rounding Method of AS

48、TM E 29 shall be used. ICEA P-57-653 is a useful guide for metric units used in this publication. 1.4 Definitions For the purposes of this Standard, the following definitions apply. 1.4.1 Cable Classifications ANSI/ICEA S-122-744-2016 4 1.4.1.1 Composite Cables1Cables containing more than one type o

49、f optical fiber. 1.4.1.2 Dielectric Cables Cables containing no metallic members or other electrically conductive materials. 1.4.1.3 Hybrid Cables1Cables having both optical fibers and metallic conductors that are intended for communications use or powering. 1.4.1.4 Metallic Cables Cables containing conductive members including those not normally intended to transmit information (voice, video, or data), such as metallic strength members, sheaths, shields, or armors.

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1