ANSI INMM N15.56-2014 For Methods of Nuclear Material Control-Nondestructive Assay Program-Nondestructive Assay Measurements of Nuclear Material Holdup General Provisions (Institut.pdf

上传人:syndromehi216 文档编号:436856 上传时间:2018-11-14 格式:PDF 页数:24 大小:125.20KB
下载 相关 举报
ANSI INMM N15.56-2014 For Methods of Nuclear Material Control-Nondestructive Assay Program-Nondestructive Assay Measurements of Nuclear Material Holdup General Provisions (Institut.pdf_第1页
第1页 / 共24页
ANSI INMM N15.56-2014 For Methods of Nuclear Material Control-Nondestructive Assay Program-Nondestructive Assay Measurements of Nuclear Material Holdup General Provisions (Institut.pdf_第2页
第2页 / 共24页
ANSI INMM N15.56-2014 For Methods of Nuclear Material Control-Nondestructive Assay Program-Nondestructive Assay Measurements of Nuclear Material Holdup General Provisions (Institut.pdf_第3页
第3页 / 共24页
ANSI INMM N15.56-2014 For Methods of Nuclear Material Control-Nondestructive Assay Program-Nondestructive Assay Measurements of Nuclear Material Holdup General Provisions (Institut.pdf_第4页
第4页 / 共24页
ANSI INMM N15.56-2014 For Methods of Nuclear Material Control-Nondestructive Assay Program-Nondestructive Assay Measurements of Nuclear Material Holdup General Provisions (Institut.pdf_第5页
第5页 / 共24页
亲,该文档总共24页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、American National Standardfor Methods of Nuclear Material Control Nondestructive Assay Program Nondestructive Assay Measurementsof Nuclear Material Holdup:General ProvisionsANSI N15.56-2014An INMM Sponsored DocumentANSIN15.56-2014ANSIN15.56-2014American National Standardfor Methods of Nuclear Materi

2、al Control Nondestructive Assay Program Nondestructive Assay Measurementsof Nuclear Material Holdup:General ProvisionsSecretariatInstitute of Nuclear Materials ManagementApproved October 20, 2014American National Standards Institute, Inc.Approval of an American National Standard requires review by A

3、NSI that therequirements for due process, consensus, and other criteria for approval havebeen met by the standards developer.Consensus is established when, in the judgement of the ANSI Board ofStandards Review, substantial agreement has been reached by directly andmaterially affected interests. Subs

4、tantial agreement means much more thana simple majority, but not necessarily unanimity. Consensus requires that allviews and objections be considered, and that a concerted effort be madetowards their resolution.The use of American National Standards is completely voluntary; theirexistence does not i

5、n any respect preclude anyone, whether he has approvedthe standards or not, from manufacturing, marketing, purchasing, or usingproducts, processes, or procedures not conforming to the standards.The American National Standards Institute does not develop standards andwill in no circumstances give an i

6、nterpretation of any American NationalStandard. Moreover, no person shall have the right or authority to issue aninterpretation of an American National Standard in the name of the AmericanNational Standards Institute. Requests for interpretations should beaddressed to the secretariat or sponsor whos

7、e name appears on the titlepage of this standard.CAUTION NOTICE: This American National Standard may be revised orwithdrawn at any time. The procedures of the American National StandardsInstitute require that action be taken periodically to reaffirm, revise, orwithdraw this standard. Purchasers of A

8、merican National Standards mayreceive current information on all standards by calling or writing the AmericanNational Standards Institute.American National StandardPublished byAmerican National Standards Institute, Inc.25 West 43rd Street, New York, NY 10036Copyright 2014 by Institute of Nuclear Mat

9、erials Management (INMM)All rights reserved.No part of this publication may be reproduced in anyform, in an electronic retrieval system or otherwise,without prior written permission of INMM, 111 Deer Lake Road,Suite 100, Deerfield, IL 60015.Printed in the United States of AmericaiContentsPageForewor

10、d ii0 Introduction. 11 Scope and purpose 12 References . 23 Definitions. 24 Administrative aspects of determining results for in situ measurements 45 Data generation and reporting 9AnnexesA Bibliography 12B Example in situ holdup NDA DQO Comparable Process form. 15iiForeword (This foreword is not pa

11、rt of American National Standard ANSI N15.56-2014.)This standard was developed under the procedures of the American National Stan-dards Institute by Accredited Standards Committee N15 on Methods of Nuclear Ma-terial Control. The secretariat of N15 is held by the Institute of Nuclear MaterialsManagem

12、ent (INMM). Committee N15 has the following scope:Standards for the protection, control, and accounting of special nuclear materials inall phases of the nuclear fuel cycle, including analytical procedures where necessaryand special to this purpose, except that physical protection of special nuclear

13、materi-als within a nuclear power plant is not included.This standard defines administrative practices for generating and reporting of nonde-structive assay (NDA) data regarding holdup deposits. It provides guidance on proce-dures, definition of terms, definition of data quality objectives, vocabula

14、ry,recordkeeping, application of techniques, calculation, reporting of values, and uncer-tainties so that some consistency of use can be achieved by as large a community ofstakeholders as practicable.Suggestions for improvement of the standard will be welcome. They should be sentto the Institute of

15、Nuclear Materials Management, 111 Deer Lake Road, Suite 100,Deerfield, IL 60015. (Additional information about the INMM may be found at http:/www.inmm.org.)This standard was prepared by Committee N15 following ANSI requirements for dueprocess and for obtaining consensus. N15 Committee approval of th

16、e standard doesnot necessarily imply that all committee members voted for its approval. At the time itapproved this standard, the N15 Committee had the following members:Melanie May, Chair(U.S. Department of Energy)Lynne Preston, Vice-Chair(U.S. Department of Energy)Steven Ward, Secretary(Entergy Op

17、erations, Inc.)Organization Represented Name of RepresentativeAmerican Nuclear Society (ANS) . Ronald KniefAmerican Society for Quality (ASQ) . Chuck MoseleyAmerican Society for Testing and Materials (ASTM) Usha Narayanan American Society of Industrial Security (ASIS) Robert D. HulshouserAREVA-NP .

18、Dan NossBabcock now used by the Society as its complete name. 1Available from the ANSI Electronic Standards Store (ESS) at www.webstore.ansi.org . 2Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959 (http:/www.astm.org/). ANSI N15.56-2014 3 3.2

19、audit: An examination of current activities to assure that they are in compliance with program policies and procedures. 3.3 Data Quality Objective (DQO): An agreement between the measurement organization and its customer regarding the quality of the data expected and the type of quality programs in

20、place to assure the quality of the measurement data. (See 4.1.1.6 for more details.) 3.4 Generalized-Geometry Holdup (GGH): This holdup measurement technique simplifies analysis by approximating the geometry of a holdup deposit as a point, line, or area source. 3.5 holdup: The residual nuclear mater

21、ial remaining in process equipment and facilities 1. 3.6 in situ measurements: A method of data collection or manipulation of a sample in its original position, without exposure to an external environment. 3.7 ISO: The acronym for the International Organization for Standardization. 3.8 item: Materia

22、l potentially containing a radioisotope to be measured 1. 3.9 matrix: The material that comprises the bulk of an item, except for the radionuclide(s) of interest and the container 1.3.10 method validation: As used in this standard, validation provides documented, objective evidence that the choice o

23、f measurement method is capable of meeting specified requirements.33.11 nuclide mapping: Determining the isotopic composition of holdup at specific locations to assess isotopic distribution and variability and to detect the presence of radionuclides that could interfere with the holdup measurement.

24、3.12 self-attenuation: The attenuation of emitted radiation by the emitting material itself, including any matrix material(s). 3.13 special nuclear material (SNM): U-233, uranium enriched in U-235, plutonium, or any combination thereof, and any other material which, pursuant to the provisions of Sec

25、tion 51 of the Atomic Energy Act of 1954, as amended, has been determined to be special nuclear material, but does not include source material; it also includes any material artificially enriched by any of the foregoing, not including source material as defined by the Atomic Energy Act, Title 42, U.

26、 S. Code, Section 2002, et seq. 3.14 system qualification: The documented process of ensuring that a specific measurement system is capable of providing reliable and consistent data of the needed quality. 3.15 Type A uncertainty: An uncertainty whose evaluation is based on any valid statistical meth

27、od for treating data 2. EXAMPLE: Calculating the standard deviation of the mean of a series of independent observations or using the method of least squares to fit a curve to data in order to estimate the parameters of the curve and their standard deviations. 3IUPAC Technical Report “Harmonized Guid

28、elines for Single-Laboratory Validation of Methods of Analysis,” Pure Appl. Chem, Vol. 74, No. 5, pp. 835-855, 2002 provides a more complete explanation of factors to be considered during method validation and system qualification. ANSI N15.56-2014 4 3.16 Type B uncertainty: An uncertainty whose eva

29、luation is based on scientific judgment using all relevant information available 2. EXAMPLE: Previous measurement data, experience with or general knowledge of the behavior of similar measurements, manufacturers specifications. 4. Administrative aspects of determining results for in situ measurement

30、s 4.1 Measurement method 4.1.1 Method selection Many interrelated factors shall be considered in choosing the method to use for in situ holdup measurements. When these factors have been thoroughly evaluated and the measurement method has been specified, all considerations affecting the choice shall

31、be documented and archived for future reference (5.1). Factors to be considered are: 4.1.1.1 Customer/Purpose of measurement This factor, in many cases, controls the approach to the measurement and the presentation of the measurement results. Measurements are performed for Materials Control and Acco

32、untability (MC process control; criticality safety; radiological protection; deactivation and decommissioning (D waste characterization; process cleanout; and combinations of these and other reasons. Each reason for the measurement might have different objectives, e.g., different uses, for the measu

33、rement uncertainty. The measurements may be quantitative, relative mapping, or both. Holdup measurements can be routine at operating facilities so relative monitoring may be applied as an alternative to absolute measurements when well below criticality safety limits. Data quality objectives and end

34、use of the measurement results should be documented prior to starting any measurements. 4.1.1.2 Materials to be measured The element(s) and isotope(s), the chemical and physical forms, and the radiation signatures likely to be present shall be considered. Measurement of uncommon actinides such as Np

35、, Cm, Am, Th, etc. could present additional measurement challenges that will need to be addressed. There is more measurement and instrumentation information available for measurements on U and Pu than there is for the less common actinides. Factors to be considered include: Radiation signature or is

36、otopic distribution Background interference Matrix Containment of measured material Intervening materials Chemical forms Densities Some measurement methods probe the nuclide of interest directly, while others use indirect radiation signatures. For example, gamma measurements usually deal with charac

37、teristic emissions from the nuclide of interest (U-235, Pu-239), whereas passive neutron-counting techniques are based on radiation from associated nuclides (U-234, Pu-240). Some parameters affect the use of certain measurement methods but not others. For example, self-shielding, container type, and

38、 high-density matrix effects often attenuate a gamma signal, while not significantly affecting a neutron measurement. On the other hand, neutron systems are sensitive ANSI N15.56-2014 5 to low z materials and chemical form due to their neutron attenuation and production differences, but these factor

39、s often do not affect gamma measurements significantly. 4.1.1.3 Physical measurement conditions Measurement conditions greatly influence the choice of detector type and data analysis methods. Facility and process equipment blueprints or drawings should be used if available, and all stakeholders shou

40、ld conduct a walk-down of the measurement site to jointly evaluate the measurement conditions for non-routine measurements. The safety and security of the measurement and the results should always be considered. Factors specific to the measurement to be considered include: Access to measurement loca

41、tion(s) Environment i.e., temperature, moisture, and dust, etc. Equipment/process configuration Size of the process equipment, including thickness and uniformity characteristics of attenuating materials Height and spacing of the process equipment and/or piping Power availability 4.1.1.4 Measurement

42、resources Numerous measurement methods exist for in situ holdup measurements 3, 4, 5, 6, 7, 8. The measurement personnel should adapt their resources to the best method to meet data quality objective requirements. Factors to be considered include: Training and experience of measurement personnel Typ

43、es and quantity of measurement equipment Time available for performing measurements and for reporting results NDA lessons learned and good practices 4.1.1.5 Constraints Constraints can take many forms both technical and nontechnical. Constraints to be considered include: Time allotted for the measur

44、ements When results are needed Operational significance Location access Funding Equipment 4.1.1.6 Data quality objectives The customer and the measurement organization should agree on the expectations for data quality, given the measurement issues noted above and the data quality requirements of the

45、 customer. This agreement can be based on the Data Quality Objective process described in EPA QA/G4 9 or on a facility specific comparable process. See Annex B for a generic blank DQO form example. This agreement shall be documented and archived for each specific task. Data quality objectives have a

46、 significant effect on measurement method selection, the accuracy and precision of resulting measurements, and the time and cost to perform measurements. Data quality objectives could include the following: ANSI N15.56-2014 6 Desired precision and accuracy Application to compliance criteria Peer rev

47、iew of method or results Measurement and personnel qualification Re-measurement program Sampling plans Relationship between data acquisition and data analysis, such as allowable time lapse and whether done by same/different personnel 4.1.1.7 Method validation Once a method has been selected, the met

48、hods fitness for purpose shall be validated, or evaluated, before it is qualified. The purpose of validation is to demonstrate, in a documented form, that the method chosen is appropriate to the needs of the end users of the data that will be produced. Validation of methods employed by measurement s

49、ystems that will be subsequently qualified may be accomplished by citing available published references and publications describing successful measurements under the expected conditions. External peer review by subject matter experts can also be used for validation of a technique or its application. If the proposed method lacks published validation for the specific data quality objectives, the user should perform measurements and testing under expected holdup measurement conditions to validate the method.4

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf