1、An AmericAn nAtionAl StAndArdNECA 505-2010Standard fornullstallinnulland Maintaininnullnullnull Mast, nulladnully andnullea nullnulltinnullnullnullished nullnulltional nullenullrinulll Contranullors nullsonullationTStandardforInstallingandMaintainingHighMast,Roadway andAreaLightingNECA 505-2010An Am

2、ericanNational StandardPublishedbyNationalElectricalContractors Associationiii a73Foreword .v1. Scope 12. Definitions 23. Receiving, Inspecting, Handling, and Storage 33.1 Receiving 33.2 Handling 33.3 Storage 34. Pre-Installation 54.1 Coordination 54.2 LocatingEquipment 54.3 Excavating,Trenching,and

3、DirectionalBoring 64.4 RacewaysandBoxes .64.5 Foundations .65. Installation .85.1 GeneralRequirements .85.2 AssemblingMultiple-SectionPoles .85.3 AttachingMastArmsandAccessories.95.4 InstallingHighMastTopAssembly.95.5 InstallingLuminaires 95.6 SettingPolesinPlace .105.7 SettingEmbeddedPolesinPlace10

4、5.8 SettingPolesonFoundations.105.9 FinalAssemblyandAdjustments115.10 WiringMethods .125.11 Grounding6. System Startup and Commissioning 136.1 General .136.2 EnergizingLuminaires 136.3 OperationalTestingandAdjustments136.4 Documentation,Training,andSpecialTools 147. System Startup and Commissioning

5、157.1 General .157.2 GroupRe-Lamping .157.3 InspectionsandMaintenance 15Annex A: Reference Standards .16Table of Contentsv a73National Electrical Installation Standardsareintend-edtoimprovecommunicationamongspecifiers,pur-chasers,andsuppliersofelectricalconstructionser-vices. Theydefineaminimumbasel

6、ineofqualityandworkmanshipforinstallingelectricalproductsandsystems. NEISareintendedtobereferencedincontractdocumentsforelectricalconstructionpro-jects.Thefollowinglanguageisrecommended:Highmast,roadway,andarealightingshouldbeinstalledandmaintainedinaccordancewithNECA505-2010,Standard for Installing

7、 andMaintaining High Mast, Roadway and AreaLighting(ANSI).UseofNEISisvoluntary,andtheNationalElectricalContractorsAssociationassumesnoobligationorlia-bilitytousersofthispublication. Existenceofastandardshallnotprecludeanymemberornon-memberofNECAfromspecifyingorusingalternateconstructionmethodspermit

8、tedbyapplicableregu-lations.Thispublicationisintendedtocomplywiththeedi-tionoftheNationalElectricalCode(NEC)ineffectatthetimeofpublication. Becausetheyarequalitystandards,NEISmayinsomeinstancesgobeyondtheminimumrequirementsoftheNEC. Itistheresponsibilityofusersofthispublicationtocomplywithstateandlo

9、calelectricalcodeswheninstallingelectricalproductsandsystems.Suggestionsforrevisionsandimprovementstothisstandardarewelcome. Theyshouldbeaddressedto:NECAStandards&Safety3BethesdaMetroCenter,Suite1100Bethesda,MD 20814(301)215-4521Telephone(301)215-4500Faxwww.neca-neis.orgneisnecanet.orgTopurchaseNati

10、onal Electrical Installation Standards,contacttheNECAOrderDeskat(301)215-4504tel,(301)215-4500fax,ororderdesknecanet.org. NEIScanalsobepurchasedin.pdfdownloadformatfromwww.neca-neis.org/standards.Copyright2010,NationalElectricalContractorsAssociation. Allrightsreserved. Unauthorizedreproductionprohi

11、bited.National Electrical Installation Standards, NEIS,andtheNEISlogoaretrademarksoftheNationalElectricalContractorsAssociation. NationalElectricalCodeandNECaretrademarksoftheNationalFireProtectionAssociation,Quincy,Massachusetts.Foreword(This foreword is not a part of the standard)1 a73Thisstandard

12、describestheinstallationandmainte-nanceproceduresforhighmast,roadway,area,andsportlightingsystemsinstalledoutdoorsforcom-mercial,institutional,andindustrialapplications.ThisStandardappliestohighintensitydischargelightingluminairesrated600Voltsandlessandmountedonpoles. ThisStandarddoesnotapplytospeci

13、alizedapplicationsorinstallationswithspecialenvironmentalorregulatoryconditions.AllinformationinthispublicationisintendedtoconformtotheNationalElectricalCode(ANSI/NFPAStandard70). InstallersshouldalwaysfollowtheNEC,applicablestateandlocalcodes,andmanufacturersinstructionswheninstallingandmaintaining

14、highmast,roadway,andarealightingsystems.Onlyqualifiedpersonsfamiliarwiththeconstructionandoperationofhighmast,roadway,andarealight-ingsystemsshouldperformtheworkdescribedinthispublication.OtherNational Electrical Installation Standardspro-videadditionalguidanceforinstallingparticulartypesofelectrica

15、lproductsandsystems. AcompletelistofNEISisprovidedinAnnexB.1. Scopea73 2AreaLight Aluminairedesignedtobemountedonapoleandintend-edtoilluminateanareasuchasaparkinglot,driveway,oryard.HighMastLight Alightingstandardtypicallyinexcessof 30m(100ft)inheight,ofeitherthefixedorself-loweringluminaireringdesi

16、gn. Accesstofixedlumi-naireringhighmastlightsisprovidedeitherbyacraneandbucket,orwithclimbingringsandasafetyplatformforservic-ing. Accesstoself-loweringluminaireringhighmastlightsisaccomplishedbyloweringtheluminaireringtothegroundwheremaintenanceworkcanbeperformed. Uponcompletion,theluminaireringisr

17、aisedandlatchedintoplace.Lighting ThecompleteassemblyofaStandard lightingpole,bracketsormastarms,andluminaires.LowMastLight Alightingstandardtypicallybetween9mand30m(30and100ft)inheight,ofeitherthefixedorself-loweringluminaireringdesign. Accesstofixedluminaireringlowmastlightsisprovidedeitherbyacran

18、eandbucket,orwithclimbingringsandasafetyplatformforservic-ing. Accesstoself-loweringluminaireringlowmastlightsisaccomplishedbyloweringtheluminaireringtothegroundwheremaintenanceworkcanbedonesafelyandefficiently.Uponcompletion,theluminaireringisraisedandlatchedintoplace.Luminaire Acompletelightinguni

19、tcon-sistingofalightsourceorlampstogetherwiththeparts,reflec-tor,and/orrefractorusedtodis-tributethelight,asockettosupportandpositionthelamps,wiringterminals,andhousing.SportsLight Adirectionalluminairespeciallydesignedforlightingsportsfields.2. Definitions3.1 Receivinga) Upondeliveryofequipment,par

20、ts,andcompo-nents,visuallyinspectpackagingforphysicaldamage.Carefullyunpackmaterialssufficientlytoinspectforconcealeddamageresultingfromshippingandhan-dling. Ifdamagehasoccurred,notifythedeliveringcarrierandthemanufacturerinwritingimmediately.Requestacarrierinspection. Notetheconditionoftheshipmento

21、nallcopiesofthedeliveryreceipt.Fileaclaimwiththecarrier.b) Compareequipment,parts,andcomponentsreceivedwiththebillofmaterialstoverifythattheshipmentiscomplete. Verifythatequipmentandaccessoriesreceivedconformtoapprovedsubmittalsandmanufacturerquotations. Iftheshipmentisnotcompleteorisinerror,notifyt

22、hemanufacturerinwritingimmediately.c) Ifequipment,parts,andcomponentsaretobestoredpriortoinstallation,restoreoriginalpackingmaterials. Whenconditionspermit,leavepackingmaterialsandwrappingsintactuntilreadyforinstal-lation.3.2 Handlinga) Handleequipmentandaccessoriesinaccordancewithmanufacturerrecomm

23、endationsinordertoavoidpersonalinjuryandequipmentdamage.b) Obtaintheshippingweightandthetypeoftruckmakingthedeliverypriortoreceivingtheshipment.Verifythatthehandlingequipmentissuitableforthematerialdeliverymethod,andthattheliftingcapaci-tyismorethantheweighttobemoved.c) Movematerialbyhand,dolly,orot

24、herdeviceinamannersoasnottocausedamage. Handleequip-mentcarefullytopreventdamage,breakage,denting,andscoringfinishes. Useforkliftsorotherloadingequipmentonlyforpalletizedshipmentsandforlargeorheavyobjects,suchaspolesandmastarms.Provideadditionalpaddingwhenusingforkliftsorotherequipment.d) Usebeltsli

25、ngsorropestoprotectfinisheswhenhandling,raising,andsettingpoles. Handlepoleswithnonmetallicfinisheswithwebfabricstraps. Donotusemetallicchainsorcables. Donotdragtreat-edpolesalongtheground. Donothandlewoodpoleswithtongs,canthooks,orotherpointedtoolscapableofproducingindentationmorethan6mm(1/4in.)ind

26、epth. Donotapplytoolstogroundlinesectionofwoodpoles.3.3 Storagea) Followmanufacturerrecommendationsforpro-tectionandstorageofequipment,parts,andcompo-nents. Stackorotherwisestoretopreventdamage,observingwarningsandstackinginstructionsonpackagingorshippingmaterials.b) Protectfromenvironmentalconditio

27、ns,suchasrainandsnow,untilfinalassemblyiscompleted.Protectfromcorrosivegasesorfumes,dirt,dust,debris,foreignobjects,androdents. Moistureincombinationwithcementdustisverycorrosivetoelectronicequipment.c) Storeinamonitoredareatodiscouragedamage,vandalism,andtheft,andoutofthewayofconstruc-tiontraffic.d

28、) Storepolesoutdoorsontreated,decay-resistantskidsaminimumof300mm(1ft)abovegradeandanyvegetation,whereaccessiblefordelivery,prepara-3. Receiving, Inspecting, Handling,and Storage3 a73tion,andinstallation. Supportpolestopreventdis-tortion,andarrangetoprovidefreeaircirculation.e) Storelightingequipmen

29、t,luminaires,accessories,andfittingsindoorsinaclean,dry,well-ventilatedspace. Avoidlocationswherewatermightaccumulateorwheresignificantairbornedustordirtispresent.Wrapmaterialsinaprotectivecoveringandusepal-lets,shelves,orothermeanstoelevatematerialabovethefloortoprotectfrompossiblewaterdamage.NECA

30、505 Standardfor InstallingandMaintainingHighMast,RoadwayandAreaLightinga73 44.1 Coordinationa) Examineareasandconditionsunderwhichpoles,luminaires,equipment,andcomponentsaretobeinstalled. Locatewater,sewer,telephone,firealarm,trafficsignal,powerlines,andotherundergroundutilitiesbeforeexcavating,tren

31、ching,anddirectionalboring.b) Checktheclearancebetweenproposedpolesandexistingoverheadutilities,suchaspowerlines,tele-phonelines,guywires,etc.,beforebeginningwork.Takenecessaryprecautionstopreventcontactwithoverheadlines.c) Coordinatewiththeelectricutilitywhenrequiredfornewservices. Coordinatetheloc

32、ationoftheutilityconnectionandprovideraceways,metercabinets,con-ductors,etc.,whenrequiredforutilityconnections.d) Scheduletherelocation,reconstruction,orotherimprovementstoexistingroadwaylightingtomain-tainilluminationduringhoursofdarkness,orpro-videtemporarylighting,ifnecessary.e) Establishastaging

33、area,suchasaclearportionofaparkinglot,driveway,orserviceyardneartheintendedinstallationlocation,forpoleassemblyandstaging. Usematerialssuchasplywood,wallboard,orthecardboardinwhichthematerialwasshippedtoprotectmaterials,andprovidesufficientlumberorrailroadties,tosupportthepolesduringassembly.Takepre

34、cautionstopreventdiscoloringorotherdamagetopolesandluminairescausedbystains,fin-ishes,ortreatmentsonthesupportmaterials.f) Notifythegeneralcontractor,engineer,orownerinwritingofadverseconditions. Donotproceedwiththeinstallationuntiladverseconditionshavebeenresolved.4.2 LocatingEquipmenta) Locatepole

35、sandequipmentinaccordancewithcontractdocuments,approvedshopdrawings,andmanufacturerrecommendations,andtomaintaintheminimumrequiredlightinglevels. Verifyallprojectdimensionsonsite.b) Adjustpoleandequipmentlocationstomaintainrequiredclearancesandtoavoidobstructions,unde-sirablefoundationconditions,etc

36、. Obtainapprovalforfieldchangestopolelocationspriortoconstruc-tion. Considerobstructions,trees,buildings,fences,roadways,trafficbarriers,guardrails,etc.,indeter-miningfinallocations.c) Locatefoundationsandbaseswithaminimumhorizontalclearanceof3.0m(10ft)tostormsewersorotherundergroundinstallationstha

37、tmightaffectstability.d) Setpolesbackfromstreetcurbsinaccordancewithcontractdocuments. Intheabsenceofrequire-ments,setbackapproximately900mm(3ft)fromstreetcurbandwherelocationsareaminimumhaz-ardtovehiculartraffic.e) Locatepathwayandsidewalklightingsuchthatlumiairetopsdonotoverhangstreets,sidewalks,o

38、rpathways,andareclearofpedestriantrafficandsnowremoval,mowing,andcultivatingactivities.f) Installanapprovedbreakawaybasewheninstallingpolesinsideofthetraffic-clearzone,orwhenlocatingpolesbehindtrafficbarriers,ifthepolesarewithinthedesigndeflectiondistanceofthebarriers.g) Avoidlocatingpolesonasteepsl

39、ope. Avoidlocatingpolesontopofmedianbarriers.4. Pre-Installation5 a734.3 Excavating,Trenching,andDirectionalBoringa) Excavatecarefullytopreventdamagetopave-ment,sidewalks,guardrails,etc. Takeprecautionsandmanuallydigwhennecessarytoavoiddamagingburiedutilities,underdrains,stormsewersystems,andotherbu

40、riedfacilities.b) Limitexcavationstothatwhichwillprovidesuffi-cientworkingspace. Excavateasnearlyaspracticabletotherequireddimensions. Forembeddedpoles,excavatesufficientlytopermittheuseoftampersthefulldepthofthehole.c) Protectexcavationsfromsurface,subsurface,andgroundwaterflowingintotheexcavation.

41、 Usepumpsorotherapproveddewateringmethodsasnecessarytoremovewaterfromexcavations.d) Directionalboreroadanddrivewaycrossingswhererequired. Exposeallundergroundutilitiesbeforebeginningdirectionalboring.e) Forhighmastcaisson-typefoundations,augercaissonholes. Installasuitablecasingatthesametimeastheaug

42、uring,whenrequired. Ensurethatcaissonholesareverticalanduniform. Fillirregular-itiesinthecylindricalsurfaceofuncasedholesout-sidethenominaldiameterwithconcrete.f) Returnthesitetotheoriginalconditionafterexcavating,trenching,anddirectionalboring.4.4 RacewaysandBoxesa) Installundergroundnonmetallicrac

43、ewaysandboxesinaccordancewithNECA/NEMA605,Installing Underground Nonmetallic Utility Duct(ANSI)andNECA111,Standard for InstallingNonmetallic Raceways (RNC, ENT and LFNC).b) Installundergroundracewaysafterthesurround-ingareahasbeenbroughttofinalgrade.c) Installundergroundutilitywarningtapeimmedi-atel

44、yabovecircuitcables. Burythetapeatadepthof150to250mm(6to10in.).d) Installgroundingbushingsattheendofraceways.e) Carefullyalignracewaysverticallyandhorizontally.Makestubsintopolesplumbandevenlydistributed.f) Installlightingandtrafficsignalconductorsinseparateracewaysandjunctionboxes.g) Installpullbox

45、essothatthecoversarelevelwiththecurborsidewalkgradeor25mm(1in.)abovetheexistingground.4.5 Foundationsa) Providefoundationsforlightingpolesinaccor-dancewithmanufacturerrecommendations.Complywithdetailsandmanufacturerrecommenda-tionsforelevations,reinforcing,anchorbolts,tem-plates,nuts,washers,etc.b)

46、Constructfoundationstonotlessthanthemini-mumdimensionsincontractdocuments.Embedmentdepthsaretypicallyaminimumof10%ofpolelengthplus600mm(2ft). Footingsaredependentuponsoilstrength,andmustbedesignedandsizedtowithstandtheappliedpoleloadings.Installbridge-mountedpoleanchorsinaccordancewithconstructiondo

47、cuments.c) Setthetopelevationofthefoundationaccurately,leveledrelativetofinalgrade. Userigidformscon-structedofwood,plywood,steel,orotheracceptablematerialsfabricatedtoconformtotherequiredcon-figuration,line,andgrade. Reinforceformstopre-ventdeformationwhileconcreteisplacedandcured.Wetorcoatformwork

48、withapartingagentbeforeplacingconcrete.d) Arrangeanchorboltssymmetricallyaboutthecenteroffoundations,andsecurelybracesotheyareheldinproperposition,height,andalignment.Whenusingareinforcingbar/anchorboltcageassemblyinaccordancewithmanufacturerrecom-mendations,placetheassemblyinthefoundationsothatitre

49、mainsplumbandtheanchorboltsremainattherequiredheight. Provideanchorbolttemplatestoholdanchorboltssecurelyinplaceandtoresistrackingortwistingduringconcreteplacement,asNECA 505 Standardfor InstallingandMaintainingHighMast,RoadwayandAreaLightinga73 6required. Donotweldanchorboltstoeachother,tothereinforcingsteelcage,topositioningtemplates,ortoanyothercomponentofthefoundation.e) Placeracewaysinproperposition,atproperheight,andheldinplacebyatemplateuntilthecon-cretesets. Providecapstoprotecttheendsofrace-wayswhenconcreteisplaced.f) Forbreakawaysupports,ensurethatthesur-roundingsurfaceisgrad

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1