ANSI NEMA C78.375A-2014 Electric Lamps - Fluorescent Lamps - Guide for Electrical Measures.pdf

上传人:appealoxygen216 文档编号:437587 上传时间:2018-11-14 格式:PDF 页数:18 大小:593.53KB
下载 相关 举报
ANSI NEMA C78.375A-2014 Electric Lamps - Fluorescent Lamps - Guide for Electrical Measures.pdf_第1页
第1页 / 共18页
ANSI NEMA C78.375A-2014 Electric Lamps - Fluorescent Lamps - Guide for Electrical Measures.pdf_第2页
第2页 / 共18页
ANSI NEMA C78.375A-2014 Electric Lamps - Fluorescent Lamps - Guide for Electrical Measures.pdf_第3页
第3页 / 共18页
ANSI NEMA C78.375A-2014 Electric Lamps - Fluorescent Lamps - Guide for Electrical Measures.pdf_第4页
第4页 / 共18页
ANSI NEMA C78.375A-2014 Electric Lamps - Fluorescent Lamps - Guide for Electrical Measures.pdf_第5页
第5页 / 共18页
亲,该文档总共18页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI C78.375A-2014Electric Lamps -Fluorescent Lamps -Guide for Electrical MeasuresANSI C78.375A-2014 Revision of ANSI C78.375-2014 American National Standard for Electric Lamps Fluorescent LampsGuide for Electrical Measures Secre

2、tariat: National Electrical Manufacturers Association Approved August 28, 2014 American National Standards Institute 2014 National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in th

3、e development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. ANSI standards and guideline publications, of which the document contained herein is on

4、e, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process to promote fairness in the development of cons

5、ensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other

6、damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or complet

7、eness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of

8、 this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document s

9、hould rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, w

10、hich the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety o

11、r health purposes. Any certification or other statement of compliance with any health or safetyrelated information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. ANSI C78.375A-2014 2014 National Electrical Manufacturers

12、 Association i AMERICAN NATIONAL STANDARD Approval of an American National Standard requires verification by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Boa

13、rd of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be ma

14、de toward their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to t

15、he standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of t

16、he American National Standards Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American Nati

17、onal Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of approval. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards In

18、stitute. Published by National Electrical Manufacturers Association 1300 North 17th Street, Suite 900, Rosslyn, Virginia 22209 2014 National Electrical Manufacturers Association. All rights, including translation into other languages, reserved under the Universal Copyright Convention, the Berne Conv

19、ention for the Protection of Literary and Artistic Works, and the International and Pan American copyright conventions. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. Printed in the Uni

20、ted States of America ANSI C78.375A-2014 ii 2014 National Electrical Manufacturers Association Foreword (This foreword is not part of American National Standard C78.375A-2014.) This is a revised standard recently updated by the industry. Suggestions for improvement of this standard are welcome. They

21、 should be sent to the Secretary, ASC C78, National Electrical Manufacturers Association, 1300 North 17th Street, Suite 900, Rosslyn, Virginia 22209. This standard was processed and approved for submittal to ANSI by Accredited Standards Committee on Electric Lamps, C78, and its Work Group, C78WG02.

22、Approval of the standard is not meant to imply that all Work Group members voted to approve it. ANSI C78.375A-2014 2014 National Electrical Manufacturers Association iii TABLE OF CONTENTS Foreword ii 1 Scope 1 1.1 Patent Disclaimer 1 2 Normative References . 1 3 Supply Voltage Characteristics 1 4 Am

23、bient Conditions for Lamp Measurements 2 5 Ballast . 2 6 Circuits 2 6.1 Measurement Circuit . 2 6.2 Instrument Connections 2 6.4 Instant-Start Lamps 4 6.5 Rapid-Start Lamps 4 6.6 Calibration of Cathode Heating Transformers 5 6.7 Circuit Grounding 6 7 Lamp Connections . 6 7.1 Preheat-Start Lamps . 6

24、7.2 Instant-Start and Cold-Cathode Lamps 6 7.3 Rapid-Start Lamps 6 8 Lamp Stabilization . 7 8.1 Linear, Circular and U-Shaped Lamps . 7 8.2 Single-Based Compact Lamps . 7 8.2.1 Lamp Circuit Transfer 7 8.3 Abnormal Behavior . 8 8.4 Seasoning . 8 9 Electrical Instruments . 8 10 Method of Reference Cir

25、cuit Measurement of Wattage, Voltage, and Current 8 11 Method of Cold and Hot Resistance Measurement 9 11.1 Equipment Required . 9 11.2 Connections 9 11.3 Established Conditions for Measurements . 9 11.4 Measurement 9 11.4.1 Preconditioning . 9 11.4.2 Cold Resistance Rc Measurement. 10 11.4.3 Hot Re

26、sistance Rh and Rh/Rc Ratio Measurement 10 ANSI C78.375A-2014 iv 2014 National Electrical Manufacturers Association Figures Figure 1(a-f) Measurement Circuit for Fluorescent Lamps . 4 Figure 2 Circuit for the Calibration of Cathode Transformers . 5 ANSI C78.375A-2014 2014 National Electrical Manufac

27、turers Association 1 1 Scope This standard describes the procedures to be followed and the precautions to be observed in obtaining uniform and reproducible measurements of the electrical characteristics of fluorescent lamps under standard conditions when operated on alternating current (ac) circuits

28、. These methods are applicable both to lamps having hot cathodesswitch-start (preheat-start), rapid-start (continuously heated cathodes), or instant-start and to lamps of the cold-cathode variety. The electrical characteristics usually measured are lamp current, lamp voltage, and lamp power. In the

29、case of rapid-start lamps, the power measurements may include both the arc watts1 and the cathode watts. Total lamp power is the sum of arc watts and cathode watts. The methods noted in this standard apply to fluorescent lamps operated at common power-line frequencies (50 and 60 Hz) or high frequenc

30、y. 1.1 Patent Disclaimer At the time of publication, it is possible that some of the elements of this document may be the subject of patent rights. When this Standard was approved for publication, the Accredited Standards Committee C78 and the National Electrical Manufacturers Association (NEMA) did

31、 not know of any patent applications, patents pending, or existing patents. ASC C78 shall not be held responsible for identifying any or all such patent rights. 2 Normative References The following publications contain provisions which, through reference in this text, constitute provisions of this A

32、merican National Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this American National Standard are encouraged to investigate the possibility of applying the most recent editions of the publications i

33、ndicated below. ANSI C78.81, Double capped fluorescent lamps Dimensional and electrical characteristics ANSI C78.901, Single based fluorescent lamps Dimensional and electrical characteristics ANSI C82.3, Reference Ballasts for Fluorescent Lamps 3 Supply Voltage Characteristics The supply voltage sha

34、ll be equal to the rated voltage of the reference ballast. During periods of stabilization, the supply shall be stable within + 0.5%. This tolerance is reduced to + 0.2% during measurement. The wave shape of the supply voltage shall be a sine wave and shall have a wave shape such that the root-mean-

35、square (rms) summation of the harmonic components shall not exceed 3% of the fundamental for all conditions that occur during the measurement. NOTEThis implies that the source of the supply should have sufficient power, and that the supply circuit should have sufficiently low impedance, compared wit

36、h the ballast impedance. 1Arc watts is the term used for the power consumed by the discharge only and does not refer to any power that may be supplied to the lamp cathodes from a separate voltage source. ANSI C78.375A-2014 2 2014 National Electrical Manufacturers Association 4 Ambient Conditions for

37、 Lamp Measurements Certain electrical characteristics, and also the light output, of fluorescent lamps are appreciably affected by variations in ambient temperature and by air movement along the bulb surface. Lamps shall be tested in a draft-free atmosphere at an ambient temperature of 25 +1 degrees

38、 C unless otherwise specified on the relevant lamp data sheet. This temperature shall be measured at a point at least one, but not more than three, feet from the lamp and at the same height as the lamp. For lamps burned in a base-up position, the height is defined as the mid-point of a plane, bisect

39、ing the vertical axis of the lamp. The temperature-measuring device shall be shielded from the lamp or radiation from any other source. The lamps shall be tested in the operating position specified in the appropriate lamp standard. Consult the manufacturer if no standard exists. Generally linear lam

40、ps are operated in the horizontal position and single-based compact lamps are operated base-up. 5 Ballast When the electrical characteristics of a fluorescent lamp are being measured for rating purposes, the lamp shall be operating in conjunction with a reference ballast. (The use of a ballast havin

41、g differing characteristics, even though of the same impedance, can significantly alter the measured electrical characteristics of the lamp.) The general characteristics of reference ballasts are described in ANSI C82.3. The specific values of impedance, reference current, and rated input voltage fo

42、r the reference ballasts corresponding to each lamp size are given in the respective lamp standards, ANSI C78.81 and ANSI C78.901. 6 Circuits 6.1 Measurement Circuit The measurement circuit employed for fluorescent lamps is shown in Figures 1(a) through 1(f). The reference ballasts used for lamp mea

43、surement are of the series-reactor type and do not include a step-up transformer. In many cases, a separate step-up transformer is needed to provide the input voltage required by the reference ballast. 6.2 Instrument Connections Figure 1(a) shows the method of connecting instruments into the circuit

44、. The voltmeter and the potential element of the wattmeter are connected on the lamp side of the current-measuring instruments. Reference ballasts may be set up either with or without the impedances of the ammeter or wattmeter current coils included in the measured ballast characteristics. Either pr

45、ocedure is satisfactory. Figure 1(b) shows the method of connecting into the circuit an instrument capable of measuring and displaying wattage, current and voltage. The potential element of the instrument is connected on the lamp side of the current measuring element. A switch provides a means of me

46、asuring either lamp or input voltage of the reference circuit with the same potential element. An auxiliary voltmeter, V2, can be used if monitoring input and lamp voltage simultaneously is desirable. Satisfactory results can be obtained using the circuit shown in either Figure 1(a) or Figure 1(b).

47、ANSI C78.375A-2014 2014 National Electrical Manufacturers Association 3 Figure 1(a) Figure 1(b) Figure 1(c) Note 3 T1 Figure 1(d) ANSI C78.375A-2014 4 2014 National Electrical Manufacturers Association Figure 1(e) Figure 1(f) Figure 1(a-f). Measurement Circuit for Fluorescent Lamps NOTES: 1. This si

48、de of the circuit shall be the one connected to ground if a grounded supply system is used. 2. Current terminals of the instrument are shown as . Potential terminals of instruments are shown as . 3. The starting circuit may be integral to the test lamp and may include a shunt capacitor. 4. The trans

49、former supply voltage B shall come from the same line (and the same phase if a three-phase supply is being used) as the reference ballast supply voltage A. Unless the precaution is observed, the subtractive polarity of the cathode windings may not actually be obtained. 6.3 Preheat-Start Lamps For preheat-start lamps, the complete circuit needed is a combination of figures 1(a) or 1(b) with Figure 1(c). If the starting switch is normally shunted by a capacitor when the lamp is being started, this capacitor shall be disconnected before readings of la

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1