ANSI TIA-4966-1-2017 Telecommunications Infrastructure Standard for Educational Facilities Addendum 1 Updated References Accommodation of New Media Types (Addendum to TIA-4966).pdf

上传人:explodesoak291 文档编号:438606 上传时间:2018-11-14 格式:PDF 页数:14 大小:353.87KB
下载 相关 举报
ANSI TIA-4966-1-2017 Telecommunications Infrastructure Standard for Educational Facilities Addendum 1 Updated References Accommodation of New Media Types (Addendum to TIA-4966).pdf_第1页
第1页 / 共14页
ANSI TIA-4966-1-2017 Telecommunications Infrastructure Standard for Educational Facilities Addendum 1 Updated References Accommodation of New Media Types (Addendum to TIA-4966).pdf_第2页
第2页 / 共14页
ANSI TIA-4966-1-2017 Telecommunications Infrastructure Standard for Educational Facilities Addendum 1 Updated References Accommodation of New Media Types (Addendum to TIA-4966).pdf_第3页
第3页 / 共14页
ANSI TIA-4966-1-2017 Telecommunications Infrastructure Standard for Educational Facilities Addendum 1 Updated References Accommodation of New Media Types (Addendum to TIA-4966).pdf_第4页
第4页 / 共14页
ANSI TIA-4966-1-2017 Telecommunications Infrastructure Standard for Educational Facilities Addendum 1 Updated References Accommodation of New Media Types (Addendum to TIA-4966).pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 TIA-4966-1 (Addendum to TIA-4966) November 2017Telecommunications Infrastructure Standard for Educational Facilities Addendum 1: Updated References, Accommodation of New Media Types ANSI/TIA-4966-1-2017 APPROVED: OCTOBER 27, 2017 NOTICE TIA Engineering Standards and Publications are designed to ser

2、ve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of suc

3、h Standards and Publications shall not in any respect preclude any member or non-member of TIA from manufacturing or selling products not conforming to such Standards and Publications. Neither shall the existence of such Standards and Publications preclude their voluntary use by Non-TIA members, eit

4、her domestically or internationally. Standards and Publications are adopted by TIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting

5、the Standard or Publication. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability

6、of regulatory limitations before its use. Any use of trademarks in this document are for information purposes and do not constitute an endorsement by TIA or this committee of the products or services of the company. (From Standards Proposal No. ANSI/TIA-PN-4966-1-D1, formulated under the cognizance

7、of the TIA TR-42 Telecommunications Cabling Systems, TR-42.1 Subcommittee on Commercial Building Telecommunications Cabling). Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION Technology and Standards Department 1320 N. Courthouse Road, Suite 200 Arlington, VA 22201 U.S.A. PRICE: Please refer to

8、current Catalog of TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION STANDARDS AND ENGINEERING PUBLICATIONS or call IHS, USA and Canada (1-877-413-5187) International (303-397-2896) or search online at http:/www.tiaonline.org/standards/catalog/ All rights reserved Printed in U.S.A. NOTICE OF COPYRIGHT Thi

9、s document is copyrighted by TIA. Reproduction of these documents either in hard copy or soft copy (including posting on the web) is prohibited without copyright permission. For copyright permission to reproduce portions of this document, please contact the TIA Standards Department or go to the TIA

10、website (www.tiaonline.org) for details on how to request permission. Details are located at: http:/www.tiaonline.org/standards/catalog/info.cfm#copyright or Telecommunications Industry Association Technology (b) there is no assurance that the Document will be approved by any Committee of TIA or any

11、 other body in its present or any other form; (c) the Document may be amended, modified or changed in the standards development or any editing process. The use or practice of contents of this Document may involve the use of intellectual property rights (“IPR”), including pending or issued patents, o

12、r copyrights, owned by one or more parties. TIA makes no search or investigation for IPR. When IPR consisting of patents and published pending patent applications are claimed and called to TIAs attention, a statement from the holder thereof is requested, all in accordance with the Manual. TIA takes

13、no position with reference to, and disclaims any obligation to investigate or inquire into, the scope or validity of any claims of IPR. TIA will neither be a party to discussions of any licensing terms or conditions, which are instead left to the parties involved, nor will TIA opine or judge whether

14、 proposed licensing terms or conditions are reasonable or non-discriminatory. TIA does not warrant or represent that procedures or practices suggested or provided in the Manual have been complied with as respects the Document or its contents. If the Document contains one or more Normative References

15、 to a document published by another organization (“other SSO”) engaged in the formulation, development or publication of standards (whether designated as a standard, specification, recommendation or otherwise), whether such reference consists of mandatory, alternate or optional elements (as defined

16、in the TIA Procedures for American National Standards) then (i) TIA disclaims any duty or obligation to search or investigate the records of any other SSO for IPR or letters of assurance relating to any such Normative Reference; (ii) TIAs policy of encouragement of voluntary disclosure (see TIA Proc

17、edures for American National Standards Annex C.1.2.3) of Essential Patent(s) and published pending patent applications shall apply; and (iii) Information as to claims of IPR in the records or publications of the other SSO shall not constitute identification to TIA of a claim of Essential Patent(s) o

18、r published pending patent applications. TIA does not enforce or monitor compliance with the contents of the Document. TIA does not certify, inspect, test or otherwise investigate products, designs or services or any claims of compliance with the contents of the Document. ALL WARRANTIES, EXPRESS OR

19、IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY OF THE CONTENTS, ITS FITNESS OR APPROPRIATENESS FOR A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND ITS NONINFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PROPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS

20、 ANY AND ALL RESPONSIBILITIES FOR THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE CONTENTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE REFERRED TO IN THE DOCUMENT OR PRODUC

21、ED OR RENDERED TO COMPLY WITH THE CONTENTS. TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING FROM OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FO

22、R LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT, BREACH OF WARRANTY, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMAGES IS A FUNDAMENTAL ELEMENT OF THE

23、 USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATIONS. ANSI/TIA-4966-1 i Telecommunications Infrastructure Standard for Educational Facilities Addendum 1: Updated References, Accommodation of New Media Types Table of Contents FOREWORD . ii 1 SCOPE . 1

24、 2 MODIFICATIONS TO ANSI/TIA-4966 . 1 2.1 General 1 2.2 Normative references (clause 2) 1 2.3 Recognized media for backbone cabling (subclause 5.3) . 1 2.4 Horizontal cabling, general (subclause 6.1) . 2 2.5 Recognized media for horizontal cabling (subclause 6.3) . 2 2.6 Work area, general (subclaus

25、e 7.1) . 2 2.7 Work area cords (subclause 7.2) . 2 2.8 Optical fiber cabling for MUTOAs (subclause 7.3.4.2) . 3 2.9 Consolidation point, general (subclause 7.4.1) 3 2.10 Cabling requirements (clause 16) . 3 ANSI/TIA-4966-1 ii FOREWORD (This foreword is not considered part of this Addendum.) This Add

26、endum was developed by TIA Subcommittee TR-42.1. Approval of this Addendum This Addendum was approved by TIA Subcommittee TR-42.1, TIA Engineering Committee TR-42, and the American National Standards Institute (ANSI). ANSI/TIA reviews standards every 5 years. At that time, standards are reaffirmed,

27、withdrawn, or revised according to the submitted updates. Updates to be included in the next revision should be sent to the committee chair or to ANSI/TIA. Annexes There are no annexes to this Addendum. Introduction Since the time of publication of ANSI/TIA-4966 three documents have been published b

28、y TIA TR-42 subcommittees which affect its content. In response, this Addendum revises references and accommodates new media types. Specifically: ANSI/TIA-568-C.2-1 specified a new balanced twisted-pair media type, category 8, specified to 2 GHz. Category 8 cabling supports 30-meter, 2 connection ch

29、annels. ANSI/TIA-568.3-D is published. Cabling transmission performance and test requirements for optical fiber cabling, guidelines for maintaining optical fiber polarity, and guidelines for field testing of optical fiber cabling are now contained in this revision, eliminating the need to reference

30、ANSI/TIA-568-C.0 for this information. In addition, a new media type, OM5 wideband laser-optimized multimode optical fiber cabling, is specified. OM1, OM2 and OS1 cabling is no longer supported. ANSI/TIA-4966-1 1 1 SCOPE This Addendum updates references and accommodates new media types introduced by

31、 ANSI/TIA-568-C.2-1 and ANSI/TIA-568.3-D. 2 MODIFICATIONS TO ANSI/TIA-4966 2.1 General Deleted text is shown as strikethrough. New text is shown as underline. 2.2 Normative references (clause 2) The references within clause 2, “Normative references,” shall be modified as follows: ANSI/TIA-568 C.2-20

32、09, Balanced Twisted-Pair Telecommunications Cabling and Components Standard NOTE The above reference includes the addendum, ANSI/TIA-568-C.2-1-2016. ANSI/TIA-568-C.3 2008, Optical Fiber Cabling Components Standard ANSI/TIA-568.3-D 2016, Optical Fiber Cabling and Components Standard 2.3 Recognized m

33、edia for backbone cabling (subclause 5.3) The text of 5.3, “Recognized media,” shall be modified as follows: This Standard specifies transmission media that shall be used individually or in combination in the backbone cabling. The recognized media are: a) balanced twisted-pair cabling compliant with

34、 ANSI/TIA-568-C.2 NOTES: 1 Category 6A is recommended for new installations. 2 Category 3 should be limited to analog voice applications. 3 Category 8 performance can be achieved by channels with a maximum of 2 connections to a maximum length of 30 m (98 ft). 4 Category 8 components can be used to c

35、onstruct a category 6A 100 m (328 ft) channel for transmission and power delivery. b) multimode optical fiber cabling compliant with ANSI/TIA-568-C.3ANSI/TIA-568.3-D, 2-fiber (or higher) fiber count NOTE OM4 or OM5 is recommended for new installations. c) single-mode optical fiber cabling compliant

36、with ANSI/TIA-568-C.3ANSI/TIA-568.3-D, 2-fiber (or higher) fiber count d) broadband coaxial cabling compliant with ANSI/TIA-568-C.4 ANSI/TIA-4966-1 2 2.4 Horizontal cabling, general (subclause 6.1) The text of the fourth paragraph of 6.1, “General,” shall be modified as follows: Optical fibers at th

37、e equipment outlet shall be terminated to an optical fiber outlet/connector meeting the requirements of ANSI/TIA-568-C.3ANSI/TIA-568.3-D. In new installations, where one or two fibers are used to make a connection at the equipment outlet, the LC connector (ANSI/TIA-604-10-B) should be used. Where mo

38、re than two fibers are used to make a single connection at the equipment outlet, the MPO connector (ANSI/TIA-604-5-D) should be used. 2.5 Recognized media for horizontal cabling (subclause 6.3) The text of 6.3, “Recognized media,” shall be modified as follows: Four types of media are recognized and

39、recommended for use in the horizontal cabling system. These media are: a) balanced twisted-pair cabling compliant with ANSI/TIA-568-C.2, category 5e, 6, 6A or 8 or higher NOTE Category 6A is recommended for new installations. NOTES: 1 Category 6A is recommended for new installations 2 Category 8 per

40、formance can be achieved by channels with a maximum of 2 connections to a maximum length of 30 m (98 ft). 3 Category 8 components can be used to construct a category 6A 100 m (328 ft) channel for transmission and power delivery. b) multimode optical fiber cabling compliant with ANSI/TIA-568-C.3ANSI/

41、TIA-568.3-D, 2-fiber (or higher) fiber count NOTE OM3 or OM4 is recommended for new installations c) single-mode optical fiber cabling compliant with ANSI/TIA-568-C.3ANSI/TIA-568.3-D, 2-fiber (or higher) fiber count d) broadband coaxial cabling compliant with ANSI/TIA-568-C.4, series 6 or series 11

42、2.6 Work area, general (subclause 7.1) The text of the first paragraph of 7.2, “General,” shall be modified as follows: The work area (WA) components extend from the outlet/connector end of the horizontal cabling system to the WA equipment. The telecommunications outlet/connector shall meet the requ

43、irements of ANSI/TIA-568-C.2 for balanced twisted-pair cabling, ANSI/TIA-568-C.3 ANSI/TIA-568.3-D for optical fiber cabling, or ANSI/TIA-568-C.4 for broadband coaxial cabling. To simplify relocations, consider a single type and configuration of outlet/connector for all work area outlets of the same

44、media type. 2.7 Work area cords (subclause 7.2) The text of the first paragraph of 7.2, “Work area cords,” shall be modified as follows: The maximum horizontal cable length is specified in clause 6.2 and is based on a maximum length of 5 m (16 ft) of WA cord. WA cords used in the WA shall meet or ex

45、ceed the performance requirements in ANSI/TIA-568-C.2 or ANSI/TIA-568-C.3ANSI/TIA-568.3-D. ANSI/TIA-4966-1 3 2.8 Optical fiber cabling for MUTOAs (subclause 7.3.4.2) The text of 7.3.4.2, “Optical fiber cabling,” shall be modified as follows: Optical fiber work area cords used with MUTOAs shall meet

46、the requirements of ANSI/TIA-568-C.3ANSI/TIA-568.3-D. The maximum horizontal cabling length is not affected by the deployment of a MUTOA. 2.9 Consolidation point, general (subclause 7.4.1) The text of the first paragraph of 7.4.1, “General,” shall be modified as follows: The consolidation point (CP)

47、 is an interconnection point within the horizontal cabling using ANSI/TIA-568-C.2 or ANSI/TIA-568-C.3ANSI/TIA-568.3-D compliant connecting hardware installed in accordance with the requirements of clause 13. It differs from the MUTOA in that a CP requires an additional connection for each horizontal

48、 cable run. Cross-connections shall not be used at a CP. No more than one CP shall be used within the same horizontal cable run. Each horizontal cable extend-ing to the WA outlet from the CP shall be terminated to a telecommunications outlet/connector or MUTOA, provided the requirements of 7.3.4 and

49、 the requirements of clause 16 are met. The cables and connections used at a CP shall meet the requirements of ANSI/TIA-568-C.2 or ANSI/TIA-568-C.3ANSI/TIA-568.3-D and be installed in accordance with the requirements of clause 13 (see figure 8). 2.10 Cabling requirements (clause 16) The text of clause 16, “Cabling requirements,” shall be modified as follows: The cabling shall comply with the requirements in ANSI/TIA-568-C.0, ANSI/TIA-568-C.2, ANSI/TIA-568-C.3ANSI/TIA-568.3-D and ANSI/TIA-568-C.4. THE TELECOMMUNICATIONS INDUSTRY ASSOCIATION TIA represen

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf