ANSI UL 60730-2-10-2013 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Motor Starting Relays (Second Edition .pdf

上传人:fatcommittee260 文档编号:439350 上传时间:2018-11-14 格式:PDF 页数:28 大小:592.41KB
下载 相关 举报
ANSI UL 60730-2-10-2013 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Motor Starting Relays (Second Edition .pdf_第1页
第1页 / 共28页
ANSI UL 60730-2-10-2013 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Motor Starting Relays (Second Edition .pdf_第2页
第2页 / 共28页
ANSI UL 60730-2-10-2013 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Motor Starting Relays (Second Edition .pdf_第3页
第3页 / 共28页
ANSI UL 60730-2-10-2013 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Motor Starting Relays (Second Edition .pdf_第4页
第4页 / 共28页
ANSI UL 60730-2-10-2013 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Motor Starting Relays (Second Edition .pdf_第5页
第5页 / 共28页
亲,该文档总共28页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 60730-2-10 Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Motor Starting RelaysUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTI

2、ON OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Motor Starting Relays, U

3、L 60730-2-10 Second Edition, Dated November 8, 2013 Summary of Topics These revisions are being issued to reect the established effective date for UL 60730-2-10. AS OF OCTOBER 19, 2018, THE FIRST EDITION OF UL 60730-2-10A AND THE TWELFTH EDITION OF UL 873 WILL BE WITHDRAWN AND WILL BE REPLACED BY TH

4、IS STANDARD. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, m

5、echanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable f

6、or any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such

7、 damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, dama

8、ge, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures

9、, and/or other elements of the Standard having future effective dates as indicated in the preface. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. The following table li

10、sts the future effective dates with the corresponding reference. MAY 16, 2014 UL 60730-2-10 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Future Effective Date Reference October 19, 2018 Second Edition MAY 16, 2014 UL 60730-2-10 tr2UL C

11、OPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL November 8, 2013 (Title Page Reprinted: May 16, 2014) 1 UL 60730-2-10 Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Motor Starting Re

12、lays The previous edition of the Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Motor Starting Relays was numbered UL 60730-2-10A. First Edition February, 2002 Second Edition November 8, 2013 This ANSI/UL Standard for Safety consists of

13、the Second Edition dated November 8, 2013. The most recent designation of ANSI/UL 60730-2-10 as an American National Standard (ANSI) occurred on November 8, 2013. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, Preface, or effective date information. The

14、National Difference Page and IEC Foreword are also excluded from the ANSI approval of IEC-based standards. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards D

15、evelopment System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property

16、 of UL. COPYRIGHT 2014 UNDERWRITERS LABORATORIES INC. ANSI/UL 60730-2-10-2013UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 8, 2013 UL 60730-2-10 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION

17、 OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface (UL) 6 NATIONAL DIFFERENCES .7 FOREWORD 8 1 Scope and normative references .11 2 Denitions 12 2.2 Denitions of types of control according to purpose 12 2.3 Denitions relating to the function of controls .13 3 General requirements 13 4 Gene

18、ral notes on tests .13 5 Rating 13 6 Classication 13 6.3 According to their purpose 13 6.13 According to value of proof tracking index (PTI) for the insulation material used .14 6.15 According to construction .14 6.15 Integrated or incorporated .14 7 Information 14 8 Protection against electric shoc

19、k .15 9 Provision for protective earthing .15 10 Terminals and TERMINATIONS .15 11 Constructional requirements 15 12 Moisture and dust resistance .15 13 Electric strength and insulation resistance .15 14 Heating 16 15 MANUFACTURING DEVIATION and DRIFT 16 16 Environmental stress 16 17 Endurance .16 1

20、8 Mechanical strength .17 19 Threaded parts and connections 17 20 CREEPAGE DISTANCES, CLEARANCES and distances through solid insulation 17 21 Resistance to heat, re and tracking 17 22 Resistance to corrosion 17 23 Electromagnetic compatibility (EMC) requirements Emission .17 24 Components .17 25 Nor

21、mal OPERATION 17 26 Electromagnetic compatibility (EMC) requirements Immunity .17 27 Abnormal OPERATION .18 28 Guidance on the use of electronic disconnection .18 NOVEMBER 8, 2013 UL 60730-2-10 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM U

22、L Figures Annexes Annex C (normative) Cotton used for mercury switch test Annex E (normative) Circuit for measuring leakage current Annex H (normative) Requirements for electronic controls H.17 Endurance .22 H.26 Electromagnetic compatibility (EMC) requirements Immunity .22 Annex 10.DVA Manufacturin

23、g and Production Tests (normative) NOVEMBER 8, 2013 UL 60730-2-10 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 8, 2013 UL 60730-2-10 5 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRI

24、BUTION WITHOUT PERMISSION FROM UL Preface (UL) This UL Standard, UL 60730-2-10, Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Motor Starting Relays, is to be used in conjunction with UL 60730-1. The requirements for motor starting relay

25、s are contained in this part 2 standard and UL 60730-1. Requirements of this Part 2 Standard, where stated, amend the requirements of UL 60730-1. Where a particular subclause of UL 60730-1 is not mentioned in UL 60730-2-10, the UL 60730-1 subclause applies. The text, gures and tables of the IEC Stan

26、dard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Motor Starting Relays, 60730-2-10, copyright 2007, are used in this Standard with the consent of the IEC and the American National Standards Institute (ANSI). The IEC copyrighted material has be

27、en reproduced with permission from ANSI. ANSI should be contacted regarding the reproduction of any portion of the IEC material. The IEC Foreword and Introduction are not a part of the requirements of this Standard but are included for information purposes only. Copies of IEC Publication 60730-2-10

28、may be purchased from ANSI, 25 West 43rd Street, 4th Floor, New York, NY 10036, (212) 642-4900. Note Although the intended primary application of this Standard is stated in its Scope, it is important to note that it remains the responsibility of the users of the Standard to judge its suitability for

29、 their particular purpose. These materials are subject to copyright claims of IEC and UL. No part of this publication may be reproduced in any form, including an electronic retrieval system, without the prior written permission of UL. All requests pertaining to the UL 60730-2-10 standard should be s

30、ubmitted to UL. UL effective date The effective date for UL 60730-2-10, second edition, is October 19, 2018. A UL effective date is one established by Underwriters Laboratories Inc. and is not part of the ANSI approved standard. MAY 16, 2014 UL 60730-2-10 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR

31、FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NATIONAL DIFFERENCES GENERAL National Differences from the text of International Electrotechnical Commission (IEC) Publication 60730-2-10, Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for

32、Motor Starting Relays, copyright 2006, are indicated by notations (differences) and are presented in bold text. There are ve types of National Differences as noted below. The difference type is noted on the rst line of the National Difference in the standard. The standard may not include all types o

33、f these National Differences. DR These are National Differences based on the national regulatory requirements. D1 These are National Differences which are based on basic safety principles and requirements, elimination of which would compromise safety for consumers and users of products. D2 These are

34、 national differences from IEC requirements based on existing safety practices. These requirements reect national safety practices, where empirical substantiation (for the IEC or national requirement) is not available or the text has not been included in the IEC standard. DC These are National Diffe

35、rences based on the component standards and will not be deleted until a particular component standard is harmonized with the IEC component standard. DE These are National Differences based on editorial comments or corrections. Each national difference contains a description of what the national diff

36、erence entails. Typically one of the following words is used to explain how the text of the national difference is to be applied to the base IEC text: Addition / Add - An addition entails adding a complete new numbered clause, subclause, table, gure, or annex. Addition is not meant to include adding

37、 select words to the base IEC text. Modication / Modify - A modication is an altering of the existing base IEC text such as the addition, replacement or deletion of certain words or the replacement of an entire clause, subclause, table, gure, or annex of the base IEC text. Deletion / Delete - A dele

38、tion entails complete deletion of an entire numbered clause, subclause, table, gure, or annex without any replacement text. NOVEMBER 8, 2013 UL 60730-2-10 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTERNATIONAL ELECTROTECHNICAL COMMIS

39、SION AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE Part 2-10: Particular Requirements for Motor Starting Relays FOREWORD The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National

40、 Committees). The object of the IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic elds. To this end and in addition to other activities, the IEC publishes International Standards, Technical Specications, Technical Reports, Publi

41、cly Available Specications (PAS) and Guides (hereafter referred to as IEC Publication(s) ). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-government

42、al organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of the IEC on

43、 technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested National Committees. 3) IEC Publications have the form of recommendation for international use and are accepted by I

44、EC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international unifo

45、rmity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional standards. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC

46、 provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, e

47、mployees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of

48、 the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to t

49、he possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 60730-2-10 has been prepared by IEC technical committee 72: Automatic controls for household use. This second edition cancels and replaces the rst edition published in 1991, Amendment 1 (1994) and amendment 2 (2001). This second edition constitutes a technical revision and updates the

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1