1、I A-A-52498 = 9999974 0165067 751 = INCH-POUND A-A-52 498 August 1, 1994 SUPERSEDING MS5 132 OB 8 September 1987 COMMERCIAL ITEM DESCRIPTION FLOODLIGHT, ELECTRIC-24 VOLT The General Services Administration has authorized the use of this commercial item description (CID) for all federal agencies. 1.

2、SCOPE This CID covers a vehicle floodlight which is controllable from outside the military vehicle. The floodlight provides localized directional illumination during night operations. 2. SALIENT CHARACTERISTICS 2.1. Materials. Unless otherwise specified herein, the materials shall be in accordance w

3、ith the manufacturers material specifications for floodlights. The use of recovered materials made in compliance with the regulatory requirements is acceptable providing all the requirements of the CID are met (see 5.4). 2.1.1 Metals. Metals shall be of corrosion resistant type or shall be treated t

4、o resist corrosion. 2.2 Design and construction. shall be as specified in figure 1. The design and construction of the floodlight 2.2.1 Housing. The floodlight housing shall be of sufficient size and mechanical strength to withstand handling, transit, storage and installation without causing malfunc

5、tion or distortion. 2.2.2 Connectors. The floodlight shall be provided with two electrical connector assemblies, Army part number 8741492. Beneficial comments, recommendations, additions, deletions clarifications, etc. and any other data which may improve this document should be sent by letter to: U

6、.S. Army Tank-Automotive Command, ATTN: AMSTA-GLC, Warren, MI 48397-5000. FSC 6220 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Licensed by Information Handling Services A-A- 52 49 8 1 1 Former MS Part Number t=-9.00 . 1 I Former Army Part Number T. A5 2 49 8- 1

7、L.625 - 18UNF-2A THREAD MS5 1320- 1 8739551 NOTES: 1. Construction is not limited to features Other than shown by dimensions, notations, and referenced documents. 2. Dimension8 are,in inches. FIGURE 1. Floodlight nominal dimensions. 2.2.3 Switch. The floodlight shall be provided with a switch, as sp

8、ecified in Army drawing number 7414388 or a suitable interchangeable switch. 2.2.4 Adapter kit. The floodlight shall be furnished with an adapter kit as specified in Army drawing number 10944440 or a suitable interchangeable adapter kit which meets the requirements of this CID. 2.2.5 - Lamp. 4572, P

9、AR 46 150 watts and 5.8 amperes lamp. The lamp shall be rated not less than 24 volts direct current (dc) and be a all glass unit sealed beam design. The floodlight shall be capable of accommodating an industry number 2.2.6 Locking device. Lockwashers, self-locking nuts, or other commercial locking d

10、evices shall be incorporated where required to prevent loosening of components and the floodlight form its attaching parts. 2.3 Beam pattern. The floodlight shall produce a beam pattern a8 shown in figure 2. 2 Licensed by Information Handling ServicesA-A-52498 9999974 DL65069 524 m A-A- 5 2 49 8 FIG

11、URE 2. Floodliuht beam Pattern. 2.4 Floodlight head rotation. The floodlight shall be capable of being rotated horizontally 175 degrees to the left and to the right of the center of rotation. It shall also be vertically adjustable upward 60 degreee and downward 30 degrees. Friction washers shall be

12、included to assure that the beam will maintain the vertical and horizontal direction selected by the operator. 2.5 Splash resistance. The floodlight shall conform to 2.3 and 2.4 after it has been subjected to a water spray of 12 hours. SAE 5575. This shall be verified by use of 2.6 Salt fog. The flo

13、odlight shall not show any signs of damage after being subjected to a 5% saline atmosphere for 200 hours. 2.6.1 Switch. test, then permitted to dry for 48 hours. The switch shall then be subjected to an additional 1,000 operations at 24 volts dc. Although water may enter the floodlight, no malfuncti

14、oning of the switch shall be observed and no water shall enter the switch. The switch shall be operated 1,000 times during the salt spray 2.7 Sand, dust and vibration. The floodlight shall conform to 2.4 when subjected to the requirements in SAE 5575. 2.8 Shock resistance. The floodlight shall not b

15、e damaged when exposed to three shocks in each direction applied along three mutually perpendicular axis of the test specimen (18 shocks). The test pulse shall be as specified in figure 3. The pulse shall have a duration of 6 milliseconds and a peak value of 75 times the acceleration of gravity. rei

16、nstalled after test completion. Lamp shall be removed prior to testing and 3 Licensed by Information Handling Services A-A-52498 m 9999974 Olb5070 246 9 A-A-52498 r;- 1.15 P P=75 gs I , A I P= PEAK VALUE D= NOMINAL DURATION o-+ t-.40 6 MILLISECONDS FIGURE 3. Shock pulse. 2.9 Temperature. The floodli

17、ght shall conform to 2.3 and 2.4 when operated in temperatures of -65O to +160 Fahrenheit. 2.10 Identification markings. Identification markings shall be permanent and legible and shall include, as a minimum, the manufacturers identification code (CAGE) and part number, the part identification numbe

18、r PIN A52498-1, and the words “24 Volt“ and “U.S.“. 2.11 Installation. Each floodlight shall be furnished with complete instructions covering its installation. 2.12 Finish treatment. Cleaning, pretreating, priming and painting of the floodlight shall conform to an appropriate CARC paint system selec

19、ted from Army drawing number 12369000 for external application. Unless otherwise specified (see 5.2), the color of the paint final top coat shall be green number 383. 3. QUALITY ASSURANCE PROVISIONS 3.1 Responsibility for inspection. The contractor is responsible for the performance of all inspectio

20、ns (examinations and tests). 3.2 Contractor certification. The contractor shall certify and maintain substantiating evidence that the product offered meets the salient characteristics of this commercial item description and that the product conforms to the producers own drawings, specifications, wor

21、kmanship standards, and quality assurance practices. Items with known defects shall not be submitted for Government acceptance. The Government reserves the right to require proof of such conformance prior to the first delivery and thereafter as may be otherwise provided for under the provisions of t

22、he contract. 4 Licensed by Information Handling ServicesA-A-52 498 4. PRESERVATION, PACKAGING, PACKING, LABELING. AND MARKING Preservation, packaging, packing, labeling, and marking shall be as specified in the contract or order (see 5.2). 5. NOTES (This section contains information of a general or

23、explanatory nature that may be helpful, but is not mandatory.) 5.1. Addresses for obtaining copies of referenced documents. 5.1.1 Army drawings. Copies of Army drawings 10944440 “Kit, Adapter, Floodlight“, 8741492 “Connector Assembly“, 7414388 “Switch Housing Assembly“, and 12369000 “Chemical Agent

24、Resistant Coatings (CARC) Paint Systems Index“ are available from the U.S. Army Tank-Automotive Command, Warren, MI 48397-5000. 5.1.2 Non-Government publications. Copies of SAE 5575 “Test for Motor Vehicle Lighting Devices, Recommended Practices“ are available from the Society of Automotive Engineer

25、s, Inc. (SAE), 400 Commonwealth Drive, Warrendale, PA 15096-0001. 5.2 ordering data. Acquisition documents must specify the following: a. Title, number, and date of this CID. b. Issue of DODISS to be cited in the solicitation, and if required, the c. d. e. Selection of applicable level and packaging

26、 requirements. specific issue of individual documents referenced. PIN number and quantity required. Final top coat color of paint, if other than specified. 5.3 Cross-reference data. Floodlights conforming to this CID are interchangeable/substitutable with floodlights conforming to MS51320B. 5.4 Regu

27、latory requirements. The offeror/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent practicable. MILITARY INTERESTS: Custodians CIVIL AGENCY COORDINATING ACTIVITY: GSA - FSS Army - AT Air Force - 99 PREPARING ACTIVITY: Army - AT Review Activities (Project 6220-1068) Air Force - 82 DLA - GS 5 Licensed by Information Handling Services