1、AMSC N/ A 1 of 2 FSC 8455DISTRIBUTION STATEMENT A . Approved for public release; distribution is unlimited.INCH-POUNDMIL-DTL-3628/138A21 September 2000SUPERSEDINGMIL-DTL-3628/13815 November 1996DETAIL SPECIFICATION SHEETBADGE, IDENTIFICATION, POLICE, CAP, DEFENSE PROTECTIVE SERVICE,OFFICE OF THE SEC

2、RETARY OF DEFENSEInactive for new design after 13 January 1999.This specification is approved for use by all Departments and Agenciesof the Department of Defense.The requirements for acquiring the product described herein shall consist of thisspecification sheet and the issue of MIL-DTL-3628 listed

3、in that issue of the Department ofDefense Index of Specifications and Standards ( DoDISS) specified in the solicitation.MATERIAL: Gilding MetalFINISH: Hard Enameled, Soft Baked Enameled, Gold Plated, Mirror-like Polished andshall match The Institute of Heraldry (TIOH) Metal Finish Chip Number 6.DIME

4、NSIONS:HEIGHT (overall) 3 inches (REF)WIDTH (overall) : 2 inches (REF)THICKNESS (at “POLICE“ lettering) : 0.085 inch 0.010 inchProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3628/138A2 of 2NOTES:1. The term (REF) refers to the measurements t

5、aken from the Government furnishedhub or die. TIOH Drawing Number B-16-10 may be used as additional reference.2. A full forcer shall be used to bring up the details of the design.3. Piercing shall be as indicated.4. Epoxy resin (stoning epoxy) may be used in lieu of both hard enamel and softbaked en

6、amel at the option of the manufacturer. When epoxy resin is used in lieu of softbaked enamel , the epoxy resin shall not be stoned. Enamel and epoxy colors shallconform to TIOH Hard Enamel Chip Numbers listed below:COLOR CHIP NUMBERGreen 12Black 26Blue 335. The attaching device shall be a screw post

7、 and thumb nut with two registeringprongs.a. The screw post shall be located on the vertical center line of the badge 1-3/4 inch 1/64 inch from the bottom of the badge.b. The registration prongs shall be located on a horizontal line 1 /8 inch 1/64 inchin from the widest portion of the top of the shi

8、eld on each side.c. The screw post shall be 9/16 inch 1/32 inch long and 0.125 inch 0.10 inch indiameter and shall have a NO. 5-4 OUNC-2A thread.d. The thumb nut shall be 0.625 inch 0.010 inch in diameter and shall have a NO.5-4 OUNC-2B thread.e. The registration prongs shall be 1 /4 inch 1/64 inch

9、in length and 0.045 inch 0.002 inch in diameter.CHANGES FROM PREVIOUS ISSUE : Marginal notations are not used in this revision toidentify changes with respect to the previous issue due to the extent of the changes.Custodian: Preparing activity:Army - IH Army - IHReview activities: (Project No. 8455-0027)DLA - CTProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ANSI IEEE 1296-1994 Information Technology - Microprocessor Systems - High-Performance Synchronous 32-Bit Bus MULTIBUS II (IEEE Computer Society Document ISO IEC 10861).pdf ANSI IEEE 1296-1994 Information Technology - Microprocessor Systems - High-Performance Synchronous 32-Bit Bus MULTIBUS II (IEEE Computer Society Document ISO IEC 10861).pdf
  • ANSI IEEE 1299-1996 Guide for the Connection of Surge Arresters to Protect Insulated Shielded Electric Power Cable Systems.pdf ANSI IEEE 1299-1996 Guide for the Connection of Surge Arresters to Protect Insulated Shielded Electric Power Cable Systems.pdf
  • ANSI IEEE 1301.3-1992 A Metric Equipment Practice for Microcomputers Convection-Cooled With 2.5 mm Connectors (IEEE Computer Society).pdf ANSI IEEE 1301.3-1992 A Metric Equipment Practice for Microcomputers Convection-Cooled With 2.5 mm Connectors (IEEE Computer Society).pdf
  • ANSI IEEE 1301.4-1996 Standard for a Metric Equipment Practice for Microcomputers - Coordination Document for Mezzanine Cards (IEEE Computer Society Document)《微处理机测量设备实施规程.夹层卡协调文件》.pdf ANSI IEEE 1301.4-1996 Standard for a Metric Equipment Practice for Microcomputers - Coordination Document for Mezzanine Cards (IEEE Computer Society Document)《微处理机测量设备实施规程.夹层卡协调文件》.pdf
  • ANSI IEEE 1303-2011 Guide for Static Var Compensator Field Tests《静止无功补偿器现场试验指南》.pdf ANSI IEEE 1303-2011 Guide for Static Var Compensator Field Tests《静止无功补偿器现场试验指南》.pdf
  • ANSI IEEE 1307-2004 Standard for Fall Protection for Utility Work《用于施工的防坠落设备的标准》.pdf ANSI IEEE 1307-2004 Standard for Fall Protection for Utility Work《用于施工的防坠落设备的标准》.pdf
  • ANSI IEEE 1308-1994 Recommended Practice for Instrumentation Specifications for Magnetic Flux Density and Electric Field Strength Meters 10 Hz to 3 kHz《10Hz-3KHz磁通密度检测仪表和电场强度计的推荐实施.pdf ANSI IEEE 1308-1994 Recommended Practice for Instrumentation Specifications for Magnetic Flux Density and Electric Field Strength Meters 10 Hz to 3 kHz《10Hz-3KHz磁通密度检测仪表和电场强度计的推荐实施.pdf
  • ANSI IEEE 1312-1993 Standard Preferred Voltage Ratings for Alternating-Current Electrical Systems and Equipment Operating at Voltages Above 230 kV Nominal《电力系统.标称工作电压在230千伏以上的交流电力系.pdf ANSI IEEE 1312-1993 Standard Preferred Voltage Ratings for Alternating-Current Electrical Systems and Equipment Operating at Voltages Above 230 kV Nominal《电力系统.标称工作电压在230千伏以上的交流电力系.pdf
  • ANSI IEEE 1325-1996 Recommended Practice for Reporting Field Failure Data for Power Circuit Breakers《动力线路断路器场失效报告的推荐实施规程》.pdf ANSI IEEE 1325-1996 Recommended Practice for Reporting Field Failure Data for Power Circuit Breakers《动力线路断路器场失效报告的推荐实施规程》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ARMY

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1