ARMY MIL-DTL-53126 5 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL ILLUMINATION SYSTEM SINGLE PHASE [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC N.pdf

上传人:sofeeling205 文档编号:444373 上传时间:2018-11-15 格式:PDF 页数:4 大小:45.60KB
下载 相关 举报
ARMY MIL-DTL-53126 5 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL ILLUMINATION SYSTEM SINGLE PHASE [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC N.pdf_第1页
第1页 / 共4页
ARMY MIL-DTL-53126 5 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL ILLUMINATION SYSTEM SINGLE PHASE [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC N.pdf_第2页
第2页 / 共4页
ARMY MIL-DTL-53126 5 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL ILLUMINATION SYSTEM SINGLE PHASE [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC N.pdf_第3页
第3页 / 共4页
ARMY MIL-DTL-53126 5 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL ILLUMINATION SYSTEM SINGLE PHASE [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC N.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AMSC N/A FSC 6150 Distribution Statement A. Approved for public release, distribution is unlimited. INCH-POUND MIL-DTL-53126/5A 16 OCTOBER 2012 SUPERSEDING MIL-E-53126(ME) 20 April 1992 DETAIL SPECIFICATION SHEET POWER DISTRIBUTION, ILLUMINATION SYSTEMS, ELECTRICAL ILLUMINATION SYSTEM, SINGLE PHASE

2、 This specification is approved for use within US Army Research Development and Engineering Command, Communications and Electronics Research and Development Center, Product Realization Directorate, Department of the Army and is available for use by all Departments and Agencies of the Department of D

3、efense. The requirement for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-53126. 1 SCOPE 1.1 Scope. This specification sheet covers the detail requirements for the Power Distribution Illumination Systems Electrical (PDISE), Type V, model: M46, NSN: 6150

4、-01-208-9751. 2 APPLICABLE DOCUMENTS 2.1 Drawings. The following Government drawings form a part of this specification sheet to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWING# NOMENCLATURE DRAWING # NOMENCLATURE CECOM & PM-MEP Drawing

5、s - Cage Code: 97403 and 30554 13226E7046 Utility Assembly, Electrical, Receptacles and Lighting (Copies of drawings required by contractors in connection with specific acquisition functions should be obtained from: PROJECT MANAGER-MOBILE ELECTRIC POWER, 5850 Delafield Road, Bldg 324 FT BELVOIR VA 2

6、2060-5809.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53126/5A PAGE 2 OF 4 3 REQUIREMENTS 3.1 Requirements. The M46, Utility Kit, PDISE shall consist of the following: Quantity Description Reference 6 Extension cables 3.3.18.7* 2 Branch

7、 circuit assemblies 3.3.18.9* 2 Branch Circuit Support Rope Assemblies 3.1.2 2 Utility Lights 3.3.18.8 1 Container 3.20*, 3.1.3 8 Securing Strap 3.3.19.1* 2 In-Line GFCI 3.3.18.10* *Note: See requirement paragraph referenced MIL-DTL-53126. 3.1.1 Utility light. The light shall be a switched, fuse pro

8、tected, single tube, 40 watt, ultraviolet stable, fluorescent lamp assembly, 120 VAC, 60 Hz, operating on an input of 0.5 ampere maximum. The 48.00-inch nominal length lamp shall produce 2770 initial lumens and the light shall operate in ambient temperatures of 0 F to 140 F, at a relative humidity o

9、f up to 80 percent. The lamp ballast shall be screened to preclude electro-magnetic interference. The light shall be provided with power cables, not less than three feet long, connected to each end of the assembly, providing input and flow-through circuits. One cable shall have a straight blade, iso

10、lated ground, input plug, and the other shall have a straight blade, isolated ground, output receptacle, both conforming to UL 943. The light shall have means for bulb replacement without the use of tools. A label affixed to the light shall contain the manufacturers identification, part number, and

11、cautionary notes, at a minimum. 3.1.2 Support line. The branch circuit assembly support line shall consist of 53 0.5 feet of rope or functional equivalent, capable of supporting the cable assembly (see 3.3.18.9 in MIL-DTL-53126) with eight repositionable slides. The slides shall fit onto the line an

12、d provide a means of attachment for the support line assembly. The use or repositioning of the slides shall not abrade the line and means shall be employed to preclude the line ends fraying or loss of the slides. 3.1.3 Storage container. The reusable storage container shall be rigidly constructed of

13、 a polyethylene or similar non-corroding material that is suitable to extended use in operating temperatures of -25 F to 120 F and extended storage at temperatures of -28 F to 160 F. The case shall not be greater than 36.00 x 24.00 x 16.00 (high) inches, and not greater than 30 pounds with a capacit

14、y of not less than 3.5 cubic feet. The case color shall be indelible and unless Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53126/5A PAGE 3 OF 4 otherwise specified (see 6.2 of MIL-DTL-53126), shall be a matte black or approximate camoufl

15、age green, color no. 34094 of FED-STD-595. The internal components may be finished with the manufacturers standard commercial color and paint, plating, or treatment. Anti-shear features shall be incorporated to prevent shock slippage between the lid and base of the container. The hinged lid shall ha

16、ve ribs molded to nest into matching recesses provided in the base, for stacking. The case shall withstand stacking eight units high, with each container loaded to a gross weight of 125 pounds. The closure shall effect an environmental seal but shall not be airtight. The container shall be provided

17、with handles, stays, latches, and hinges flush with the exterior surface, recessed, or internal to the container. 3.1.3.1 Handles. The handles shall have a nominal 90 degree stop, for use, and incorporate a method to return the released bail to rest. The bail shall be padded and suitable for use by

18、personnel (see 3.5.9 in MIL-DTL-53126) wearing arctic mittens. The handle, and its mounting, shall withstand the shear of lifting and the tensional and torsional forces of dragging the fully loaded container, in any of the environments specified herein. 3.1.3.2 Stays. The container shall be provided

19、 with an integral stay(s) that will hold the lid in an open position of 90 to 105 degrees unassisted, indefinitely, in any of the environments specified herein. Operation shall be incidental to the opening of the chest, except that user intervention is permissible for locking in place. 3.1.3.3 Latch

20、es. The latching mechanism shall not require greater than a half turn to fully engage or disengage, and shall be capable of, or supplied with provisions for, locking. The requirement to be flush or recessed applies only in the closed position, but is desirable when fully open. Design of the mechanis

21、m shall allow manipulation, to include locking, to be accomplished by personnel (see 3.5.9 in MIL-DTL-53126) wearing arctic mittens. 3.2 This specification sheet had no superseding “base”. The original publication of this specification was a performance specification that was used in-house by CR4. S

22、ince this specification is now a detailed specification, this specification sheet is deemed necessary to capture the unique characteristics desired in the end item. 3.3 Changes from previous issues: Marginal notations are not used in this revision to identify changes with respect to the previous iss

23、ue because this detail specification sheet although a part of the base document, was not published because it was a document with limited circulation and coordination that was used essentially by CR4. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-M

24、IL-DTL-53126/5A PAGE 4 OF 4 Concluding Material Custodian: Preparing Activity: Army - CR4 Army - CR4 (Project 6150-2012-014) Review Activities: DLA GS Note: The activities listed above were interested in this document as of the date of this document. Since organization and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-