1、MIL-R-30732N,43 W 7979906 0230306 5 m t f O O O c-73- E3 MIL-R-10932N 30 June 1988 SUPERSEDING MIL-R-00 10932M(GL) 8 April 1986 MIL-R-10932L 19 October 1976 MILITARY SPECIFICATION REFRIGERATORS, PREFABRICATED, PANEL TYPE This specification is approved for use by all Departments and Agencies of the D

2、epartment of Defense. 1. SCOPE 1.1 Scope. This document covers prefabricated, walk-in-refrigerators assembled by the use of interchangeable panels. Refrigeration units for use with these refrigerators shall be panel-mounted (see 6.3). 1.2 Classification. Refrigerators shall be of the following sizes

3、 as specified (see 6.2). Size 600 cubic feet 1200 cubic feet 1800 cubic feet 4000 cubic feet 1.2.1 Military part number, The military part number shall consist of the letter M, the basic number of the specification and the pppropriate numbering sequence as specified in 6.6. Beneficial comments (reco

4、mmendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Natick Research, Development, and Engineering Center, Natick, MA 01760-5014 by using the self-addressed Standardization Document Improvement Proposal (DD Form 14

5、26) appearing at the end o this document or by letter. AMSC NIA FSC 4110 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. THIS DOCUMENT CONTAINS 53. PAGES. Y Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R- 1093

6、2K 2. APPLICABLE DOCUMENTS 2,l Government documents. 2.1.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be those liste

7、d in the.issue of the Department of Defense Index of Specifications and solicitation, SPECIFICATIONS FEDERAL. A-A-71 1 L-P-320 W-F- 4 06 W- S-89 6 / 2 QQ-A-25 0/8 QQ-A-60 1 QQ-C-390 QQ-S-781 QQ-Z-363 RR-C-271 TT-S-176 TT-V-121 LLL-B-8 10 MMf-A- 12 1 PPP-B-636 PPP-F-320 PPP-S-760 PPP-T-60 PPP-T-97 MI

8、LITARY MIL-C-104 MIL-P-116 MIL-B-121 MIL-P-5 14 MIL-T-7 04 MIL-T-1205 Standards (DODISS) and supplement thereto, cited in the - Dry Cleaning Solvent - Pipe and Fittings, Plastic (Polyvinyl Chloride) PVC, - Fittings for Cable, Power, Electrical and Conduit, - Switches, Toggle and Lock, Flush Mounted

9、(AC) - Aluminum Alloy, 5052, Flate and Sheet - Aluminum Alloy Sand Castings - Copper Alloy Castings (Including Cast Bar) - Strapping, Steel, and Seals - Zinc-Base Alloy, Die Castings -.Chains and Attachments, Welded and Weldless - Sealer, Surface, Varnish Type, Floor, Wood and Cork - Varnish, Spar,

10、Water-Resisting - Building Board (Hardboard) Hard Pressed, Vegetable - Adhesive, Bonding Vulcanized, Synthetic Rubber To - Boxes, Shipping, Fiberboard - Fiberboard: Corrugated and Solid, Sheet Stock - Strapping, Nonmetallic, (and Connectors) - Tape, Packaging, Waterproof - Tape: Pressure-Sensitive A

11、dhesive, Filament Drain, Water, Vent Metal, Flexible (De tai 1 Specif ication) Fiber Steel (Container Grade), and Cut Shapes Reinforced - Crates, Wood, Lumber and Plywood Sheathed, Nailed and - Preservation, Methods of - Barrier Material, Greaseproofed, Waterproofed, - Plate, Identification, Instruc

12、tion and Marking, Blank - Treatment and Painting of Materiel - Thermometers, Self-Indicating, Liquid-in-Glass, Bolted Flexible Air and Water, Standard 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-10932N i.IL 7Ob 0230308 7 m MIL-R- 1 O932N

13、MIL-S-12204 MIL-R-13312 MIL-V-13811 MIL-F-14187 MIL-R-14328 MIL-C-16173 MIL-A-22397 MIL-R-40633 MIL-C-46168 MIL-L-47117 MIL-C-52950 - Solder, Lead-Tin Alloy - Refrigeration Units, Mechanical, Panel Mounted for Refrigerator, Prefabricated, Panel Type - Varnish, Waterproofing, Electrical, Ignition - F

14、astener, Refrigerator Panel - Rubber Sheet, Synthetic, Medium Soft, General- Purpose Gasket Material (For Extreme Climatic Conditions) - Corrosion Preventative Compound, Solvent Cutback, Co 1 d - Ap p 1 ic a t i o n - Adhesive, Phenol and Resorcinol Resin Base (For Marine Service Use) - Refrigeratio

15、n Units, Mechanical (Remote Type) for Refrigerator, Prefabricated, Panel Type - Coating, Aliphatic Polyurethane, Chemical Agent. Res is tant - Lacquer, Acrylic - Crates, Wood, Open and Covered STANDARDS MIL I TARY MIL-STD-105 - Sampling Procedures and Tables for Inspection MIL-STD-129 - Marking for

16、Shipment and Storage MIL-STD-130 - Identification Marking of U.S. Military Property MC 35647 - Padlocks, Key Operated by Attributes (Copies of specifications, standards, and handbooks required by contractors in connection with specific acquisition functions should be obtained from the contracting ac

17、tivity or as directed by the contracting activity.) 2.1.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this specification to the extent specified herein. Unless otherwise specified, the issues shall be tho

18、se in effect on the date of the solicitation. DEPARTMENT OF COMMERCE U.C. Product Standards PS 1-Softwood Plywood, Construction and Industrial (Copies may be obtained from the Superintendent of Documents, U.C. Government Printing Office, Washington, DC 20402.) 3 Provided by IHSNot for ResaleNo repro

19、duction or networking permitted without license from IHS-,-,-5-13-1144 5-1 3- 1339 5 -. 1 3- 1 8 5 8 5-13-2651 5-13-2652 5-13-2653 5-1 3-265 4 5-13-2655 5-1 3-2656 5-1 3-265 7 5-13-2658 5-13-2659 5- 13-2660 5-13-2661 5-13-2662 5-13-2663 5-1 3-2664 5-13-2665 5-13-2666 5- 13-266 7 5-13-2668 5-13-2669

20、MIL-R-10932N DRAWINGS U.S. ARMY NATICK RESEARCH, DEVELOPMENT, AND ENGINEERING CENTER - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; - Fastener, Refrigerator Panel; Assembly and - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated

21、; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; -.Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricate

22、d; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricat

23、ed; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; - Refrigerator, Panel Type, Prefabricated; Evaporator Panel, Plug “J“ Misc. Details Installation Assemblies Erection Instructions Corner Panel “A“ Standard Wall Panel “B“ Walk-in Door Walk-in Door Evaporator Pa

24、nel “D“ Floor or Ceiling Panel “FL“ Conveyor Door Panel “GI 5-13-2671 - Refrigerator, Panel Type, Prefabricated; Curtain Details (Copies of drawings, publications, and other Government documents required by contractors in connection with specific acquisition functions should be obtained from the con

25、tracting activity or as directed by the contracting activity.) 2.2 Other publications. The foliowing docriments form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of the documents which are DOD adopted shall be those listed in the issue of the DO

26、DISS specified in the solicitation. specified, the issues of documents not listed in the DODISS shall be the issues of the nongovernment documents which are current on the date of the solicitation. Unless otherwise UNDERWRITERS LABORATORIES, INC. UL 1 - Flexible Metal Electrical Conduit UL 98 - Encl

27、osed Switches (Copies may be obtained from the Underwriters Laboratories, Inc., 333 Pfingston Road, Northbrook, IL 60062.) NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) Standard No. 70 - The National Electrical Code (Copies may be obtained from the National Fire Protection Association, 60 Batterymarch

28、 Park, Quincy, MA 02169.) AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) A 48 - Specification for Gray Iron Castings A 576 - Specification for Steel Bars, Carbon, Hot-Wrought, Special Quality A 675 - Specification for Steel Bars, Carbon, Hot-Wrought, Special Quality, Mechanical Properties D 2016

29、- Moisture Content of Wood D 2846 - Chlorinated Poly (Vinyl Chloride) (CPVO) Plastic, Hot and Cold Water Distributions Systems E 18 - Test Methods for Rockwell Hardness and Rockwell Superficial Hardness of Metallic Materials (Copies may be obtained from the American Society for Testing and Materials

30、, 1916 Race Street, Philadelphia, FA 19103.) 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-O MIL-R-10932N (Nongovernment standards and other publications are normally available from the organizations which prepare or which distribute the document

31、s. These documents also may be available in or through libraries or other informational services . ) 2.3 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedence. applicable laws and r

32、egulations unless a specific exemption has been obtained, Nothing in this specification, however, shall supersede 3. REQUIREMENTS 3.1 First article. When specified in the contract or purchase order, a sample shall be subjected to first article inspection (see 4.3, 6.2, and 6.4). 3.2 Codes and standa

33、rds. Refrigerator electrical components shall comply with the applicable requirements of Underwriters Laboratories (see 4.4.7 and 4,4.7.1), and with NFPA Standard No. 70. 3,3 Materials (see 6.5). Materials and components for refrigerators shall conform to the applicable documents specified herein. C

34、ommercial tolerances shall apply to panel skin thicknesses, Materials or components not definitely specified shall be of the quality normally used in the refrigerators by the contractor. Materials or material treatments which will potentially come into contact with foodstuffs and which could cause t

35、oxic reaction or transfer flavor or odor to foodstuffs shall not be used. O 3.3.1 Lumber. Lumber used in the fabrication of components shall be hardwood or softwood, as specified herein. All lumber shall be kiln dried without honeycombing or case hardening. The moisture content at time of fabricatio

36、n shall not exceed 15 percent when tested as specified in 4.4.1.1.1, The lumber shall not be decayed, warped, or have shakes, clusters of knots greater than one-fourth of the width o the individual pieces of lumber, or surface cracks over 4 inches long, The slope of the grain of the lumber shall noz

37、: exceed 1 inch in 10 inches when tested as specified in 4.4.1.1.2. Local deviation of the grain such as burl or birds eye shall be permissible. Lumber with open knot holes or loose knots shall not be acceptable. Sound, tight knots not more than 1 l/Z inch in largest diameter shall be allowable in l

38、umber 3 inches or more in width, Sound, tight knots not more than 5/8 inch in largest diameter shall be allowable in parts less than 3 inches in width provided these knots are not positioned at the intersection of a joint or at the edge of a piece of lumber. Knots of maximum allowable size shall be

39、not closer than 12 inches, center to center, in any one piece of lumber. 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. a O O MIL-R-LO932N 41 979990b 0230332 O 9 MIL-R-10932N 3.3.1.1 Hardwood. Hardwood shall be oak. 3.3.1.2 Softwood. Softwood sh

40、all be any of the follow door and panels. The gasket as used on the doors and panels, except partition panels, shall be fabricated of flexible urethane core enclosed in a flexible urethane coating, with a reinforced single seal and of the dimensions as shown on Drawing 5-13-2664. Ends shall be joine

41、d using adhesive as specified in MMM-A-121. 3.3.8.2 Gaskets (partitions), The gaskets used on the sides and bottom of partition panels shall be synthetic rubber. The gaskets used on the top of partition panels shall be synthetic heavy duty sponge rubber and have a thin synthetic rubber coating on fo

42、ur sides resistant to deterioration from oils, fats, moisture, and direct solar radiation and shall conform to the thicknesses as shown on applicable drawings. 3.3.9 Aluminum alloy plate and sheet. Aluminum alloy plate and sheet shall conform to temper H34 of QQ-A-250/8, 3.3.10 Steel, Steel bar shal

43、l conform to ASTM A 576 and A 675. 3.311 Castings, 3.3.11.1 Iron castings, Iron castings shall conform to class 25 of ASTM A 48. 3.3.11.2 Aluminum castings, Aluminum castings shall conform to alloy 514, temper F of QQ-A-601. 3.3.11.3 Bronze castings. Bronze castings shall conform to alloy C82000, C8

44、2400, C82500, C82600, C82700, C82800, type I of QQ-C-390. The finished castings shall be given a chromium, nickel, or zinc finish. 3.3.11.4 Die-cast zinc. When die-cast zinc is used the zinc-base alloy casting shall conform to either alloys AG40A or AC41A of QQ-2-363. 3.3.12 Nonmetallic strip and tu

45、bing, rubber and plastic. 3.3.12.1 Building board. Material used for strips shown on Drawing 5-13-2657 shall conform to type II, surface 1, finish A, design a of LLL-B-810. 3.3.12.2 Nonmetallic tubing. The tubing shown on Drawing 5-13-2656 used to shield the door latch plunger from the insulation sh

46、all be nonmetallic, nonflexible, waterproof material with a low heat conductivity and shall conform to ASTM D 2846 3.312.3 Rubber, sheet and strip. The drain plug gasket and outside drain adapter gaskets shall be synthetic rubber in the thicknesses shown on the applicable drawings, and conform to MI

47、L-R-14328. 8 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-LO932N 41 W 9999906 0230334 4 W MIL-R- 1093 2N 3.3.12.4 Pipe and tube. Plastic pipe and tubing used for floor drains in panels “FL“ or “FR“ shall be rigid plastic and conform to L-P-3

48、20. plastic shall be nontoxic, resistant to acids, alkalies, metallic salts, and deterioration. The 3.3.13 Solder. Solder shall conform to type I or I, composition A of MIL-S-12204. 3.3.14 Electrical components. Wire shall be installed within flexible conduit in accordance with National Electrical C

49、ode 70. Wiring shall consist of two No. 14 AWG conductors and a ground wire. Conduit shall conform to UL Standard 1. 3.3.14.1 Fittings, conduit. Fittings shall conform to type I, class 4, style N of W-F-406. 3.3.14.2 Switch. Switches shall conform to W-S-896/2-03-A. The switch shall be housed in a vapor-tight enclosure conforming to UL Standard 98, and shall be externally operated and mounted in the cover of.the box inclosure. 3.3.14.3 Pilot light. The pil