ARMY PPP-D-729 E (1)-1983 DRUMS SHIPPING AND STORAGE STEEL 55-GALLON (208 LITERS)《储运用钢桶 55加仑(208升)》.pdf

上传人:twoload295 文档编号:449389 上传时间:2018-11-16 格式:PDF 页数:3 大小:114.74KB
下载 相关 举报
ARMY PPP-D-729 E (1)-1983 DRUMS SHIPPING AND STORAGE STEEL 55-GALLON (208 LITERS)《储运用钢桶 55加仑(208升)》.pdf_第1页
第1页 / 共3页
ARMY PPP-D-729 E (1)-1983 DRUMS SHIPPING AND STORAGE STEEL 55-GALLON (208 LITERS)《储运用钢桶 55加仑(208升)》.pdf_第2页
第2页 / 共3页
ARMY PPP-D-729 E (1)-1983 DRUMS SHIPPING AND STORAGE STEEL 55-GALLON (208 LITERS)《储运用钢桶 55加仑(208升)》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、PPP-D-729E AMENDMENT- 1 December 30. 1983 FEDERAL SPECIFICATION DRUMS, SHIPPING AND STORAGE, STEEL, 55-GALLON (208 LITERS) This amendment, which form a part of Federal Specification PPP-D-729E, dated April 22, 1977, is approved by the Assistant Administrator, Office of Federal Supply and Services, G

2、eneral Services Administration, for the use of all Federal agencies. PAGE 2 2.1, under Federal Standards: Delete “FED-STD-101 in its entirety.“ PAGE 4 3.4, line 8, after “inch“: Add “nominal*. PAGE 5 3.4.3: Delete in its entirety and substitute: “3.4.3 Capacity and outage. The rated capacity shall b

3、e 55 gallons (208 L). Actual capacity for types I, II and IV, including the convex heads shall be not less than 57.2 gallons (216.5 L) (4 percent outage) nor greater than 57.75 gallons (218.6 L) (5 percent outage), when tested as specified in 4.4.2. VII, actual capacity shall be not less than 56.1 g

4、allons (212.4 L) (2 percent outage) and not more than 56.6 gallons (214.3 L) (2.9 percent outage).“ For the types V, VI and PAGE 8 3.6.1, title: Delete “phosphatizing“ and substitute “corrosive inhibitor“. Line 2: Delete “phosphate“ and subs tutute “corrosive inhibitor“. 3.6.2: Delete in its entiret

5、y and substitute: “3.6,2 Painting. Enamel shall conform to TT-E-485 or be a standard baking enamel used in the commercial production of steel drums, pails and cans. is used, it shall be the alkyd resin type crosslinked with a melamine and urea formaldehyde type resin or either a melamine or a urea f

6、ormaldehyded type resin. In the case of containers calling for baked interior-linings, commercial exterior paint using a modified polyester resin may be used instead of the normal alkyd coating. When specified, the color of the coating shall approximate Olive Drab No. 24087 or Olive Green No. 24064

7、of FED-STD-595. a minimum of 0.6 mil (0.0006 inch) when tested as specified in 4.4.9. The coating shall show good adhesion, be difficult furrow, not flake off or show evidence of jagged edges when tested as specified in 4.4.10. After a corrosive inhibitor as When the latter The film thickness of dri

8、ed coating shall be FSC 8110 THIS DOCUMENT COWAINS. 3 FAGES. . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PPP-D-729E Amendment-1 PAGE 8 (contd) specified in 3.6.1, the exterior of the drum (including plugs) shall be painted and dried. side seam

9、cleaned with a corrosive inhibitor, and painted. The inside surface of the chime reinforcement and the double seam on type I, class A and B, of type V and type VI1 drums after forming (see 3.5.5) shall be coated with paint. The painted area of the double seam shall extend not less than 1/8-inch (3.2

10、 mm) beyond the chime reinforcement. on the double seam is wet. specified (see 6.2), and when specified (see 6.2) shall be painted on the outside surface with paint specified in TT-E-485 or the standard baking enamel used in the commercial production of steel pails and drums.“ Drums which were coate

11、d in the flat, shall after welding, have the unpainted The chime reinforcement ring shall be applied while the paint The type VI drums shall not be painted except when PAGE 9 3.7, line 3, after the second sentence: Add “embossing shall be on the bottom head of the drum.“ PAGE 15 4.4.2: Delete in its

12、 entirety and substitute: “4.4.2 Capacity and outage tests. The capacity of the drum shall be determined by pouring a measured volume of fresh water into the specimen until the specified filled level is attained, and record the total volume poured in. To determine the filled level of the specimen, p

13、our a measured volume of fresh water equal to the specified capacity into the specimen. Observe and record the position of the liquid level. To determine the outage, measure the additional volume of water (Vo) required to Calculate the completely fill the specimen after it is filled to liquid capaci

14、ty. outage using the following formula: Outage in percent of liquid capacity = 100 x Vo liquid capacity: 2 - . . -T. . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PPP-D-729E (I) L 999997Li 0039005 1 m MILITARY INTERESTS : Cus t odians Army - GL N

15、avy - SA Air Force.- 69 Review Activities Army - MI, EA, MD Navy - AS, SH Air Force - 99 DIA - GS, PS, SS PPP-D-729E Amendment-1 CIVIL AGENCY COORDINATING ACTIVITIES : COMMERCE - NBS GSA - FSS HHS - NIH USDA - APS PREPARING ACTIVITY: Army - GL Project No. 81 10-0269 User Activities - Army - AR, AT Navy - MC, MS 3 * U.S. GOVERNMENT PRINTINGOFFICE 1984-705-040/A775 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ARMY

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1