1、*USACE / NAVFAC / AFCESA / NASA UFGS-13 49 19 (February 2009)-Preparing Activity: USACE SupersedingUFGS-13 49 19 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2009*SECTION TABLE OF CONTENTSDIVISION 13 - SPECIAL CONSTRUCTIONSECTION 13 49 19X-RA

2、Y SHIELDING02/09PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.3 SUBMITTALS1.4 QUALIFICATIONS1.5 DELIVERY, STORAGE, AND HANDLING1.6 WARRANTYPART 2 PRODUCTS2.1 LEAD SHEET2.2 LEAD-LINED CONCRETE MASONRY UNITS2.3 LEAD-LINED WOOD PANELS2.4 LEAD-LINED LATH2.5 LEAD-LINED GYPSUM WALLBOARD2.6 LEADED GL

3、ASS2.7 LEAD-HEADED NAILS2.8 LEAD TABS OR CLIPS2.9 LEAD-LINED WOOD DOORS2.9.1 Shielding2.9.2 Painting and Sealing Doors2.9.3 Door Hardware2.9.4 Thresholds2.10 LEAD WINDOW FRAMES2.11 LEAD LIGHTPROOF LOUVERS2.12 LEAD-LINED STEEL DOORS AND FRAMES2.12.1 Doors2.12.2 Frames2.13 FILM CASSETTE TRANSFER CABIN

4、ETS2.14 OPERATORS PROTECTIVE SCREEN2.15 DESIGNATING PLAQUES2.15.1 Required Information2.15.2 X-Ray and Examination Rooms2.15.3 Radiographic, Fluoroscopic, and Cystoscopic Rooms2.15.4 Deep Therapy RoomSECTION 13 49 19 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without

5、license from IHS-,-,-2.15.5 Rooms With Nonshielded Partitions2.15.6 Cardiac Fluoroscopy Room2.16 CONCRETEPART 3 EXECUTION3.1 INSTALLATION3.1.1 Workmanship3.1.2 Protection3.2 LEAD-LINING FOR CONCRETE FLOORS3.2.1 Shielding3.2.2 Protection from Damage3.3 LEAD-LINED BLOCKS3.3.1 Joints3.3.2 Blocks3.3.3 P

6、ipe and Conduit Chases3.4 LEAD-LINED PANELS3.4.1 Joints With Lead-Lined Joint Strips3.4.2 Joints Backed with Lead Strips3.5 LEAD-LINED LATH3.5.1 Joints3.5.2 Frames and Corners3.5.3 Wood Supports3.5.4 Metal Supports3.6 LEAD-LINED GYPSUM WALLBOARD3.6.1 Joints3.6.2 Corner Joints3.6.3 Wood Supports3.6.4

7、 Metal Supports3.6.5 Finish Ply3.7 SUSPENDED LEAD-LINED CEILINGS3.8 LEAD DOOR THRESHOLDS3.9 LEAD-LINED WOOD DOORS3.9.1 Door Hardware3.9.2 View Windows3.9.3 Lead Louvers3.10 OPERATORS PROTECTIVE SCREEN3.11 TESTING AND CERTIFICATION- End of Section Table of Contents -SECTION 13 49 19 Page 2Provided by

8、 IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-13 49 19 (February 2009)-Preparing Activity: USACE SupersedingUFGS-13 49 19 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated Janua

9、ry 2009*SECTION 13 49 19X-RAY SHIELDING02/09*NOTE: This guide specification covers the requirements for x-ray shielding for medical and dental radiological facilities.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose ap

10、plicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A l

11、isting of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: This specification essentially implements the requirements of NCRP Reports 35,

12、49 and 102; however, designers are cautioned to ensure that the requirements of TB MED 521 be met in addition to the requirements of applicable NCRP publications. In case of conflict between NCRP publications and TB MED 521, the more stringent requirements will be applied.The installation systems gi

13、ven in this guide specification are the systems more commonly used. Where details of construction require systems not included in this guide specification, the guide specification requirements will be revised to specify the required system. Criteria for users on SECTION 13 49 19 Page 3Provided by IH

14、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-radiation protection surveys is contained in TB MED 521.Design or modification of diagnostic x-ray, therapeutic x-ray, or gamma-beam therapy facilities must only be undertaken by experts certified in radiological phy

15、sics or therapeutic radio-logical physics by the American Board of Radiology or the American Board of Health Physics.Where the increase in cost can be justified by substantial increases in flexibility of the facility, allow for future rearrangement of x-ray equipment and facilities by providing the

16、maximum thickness of shielding which provides the minimum protection in all areas that could be covered by the primary beam. In any case, lead thickness must be uniform for the entire wall, ceiling, floor or partition to which it is applied.Department of the Army Technical manual 5-805-12, “X-Ray Sh

17、ielding,“ has standard details. It is included in the CCB.Include on the drawings:1. Extent of the shielding; length, width, and height of the lead sheeting.2. Joint, opening, and corner details showing the method of continuation of protection.3. Door and window details, including louvers and screen

18、s.4. Pipe and conduit chases and penetration sleeves.5. Location of all door and wall plaques.6. Stud spacing for lead lined gypsum board or lath.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in th

19、e text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Refer

20、ence Wizards Check Reference feature to update the issue dates.SECTION 13 49 19 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-References not used in the text will automatically be deleted from this section of the project specification when yo

21、u choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM B 749 (2003) Standard Specification fo

22、r Lead and Lead Alloy Strip, Sheet and Plate ProductsASTM C 129 (2006) Standard Specification for Nonloadbearing Concrete Masonry UnitsASTM C 1396/C 1396M (2006a) Standard Specification for Gypsum BoardHARDWOOD PLYWOOD AND VENEER ASSOCIATION (HPVA)HPVA HP-1 (2004) American National Standard for Hard

23、wood and Decorative PlywoodNATIONAL COUNCIL ON RADIATION PROTECTION AND MEASUREMENTS (NCRP)NCRP 144 (2003) Radiation Protection for Particle Accelerator FacilitiesNCRP Rpt 102 (1989) Medical X-Ray, Electron Beam and Gamma-Ray Protection for Energies up to 50 MeV (Equipment Design, Performance and Us

24、e)NCRP Rpt 35 (1970) Dental X-Ray ProtectionNCRP Rpt 49 (1976) Structural Shielding Design and Evaluation for Medical Use of X-Rays and Gamma Rays of Energies up to 10 MeVSTEEL DOOR INSTITUTE (SDI/DOOR)SDI/DOOR A250.8 (2003) Recommended Specification for Standard Steel Doors and FramesU.S. NATIONAL

25、ARCHIVES AND RECORDS ADMINISTRATION (NARA)29 CFR 1910.1025 LeadWINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)WDMA I.S. 1-A (1997) Architectural Wood Flush Doors1.2 SYSTEM DESCRIPTION*NOTE: For Navy projects, submit x-ray shielding designs and calculations to Chief, Bureau Medicine SECTION 13 49 19

26、 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-and Surgery, 2300 E Street NW, Washington, D.C. 20372-5000, for review and approval prior to design release.Coordinate work of this section with Sections 11 27 13 RADIOGRAPHIC DARKROOM EQUIPMENT

27、and 11 70 00GENERAL REQUIREMENTS FOR MEDICAL AND DENTAL EQUIPMENT.*Construct X-ray shielding unimpaired by joints, openings for ducts, pipes, or other openings through shielding, or conduits, service boxes, and other items embedded in the shielding. The shielding shall appear to be continuous. Insta

28、ll lead patches, lead sleeves, and/or mazes as required to provide continuity of the shielding. Minimum lead lap shall be 25 mm 1 inch. Sleeves shall be not less than 25 mm 1 inch in length. Thicknesses indicated for shielding are minimum acceptable thickness.1.3 SUBMITTALS*NOTE: Review submittal de

29、scription (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requir

30、es Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.F

31、or submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer;

32、 “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy,

33、Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval. information only. When used, a designation following the “G“

34、 designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SECTION 13 49 19 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SUBMITTAL PROCEDURES:SD-02 Shop Draw

35、ingsMaterials; G; G, _Drawings indicating thickness of lead at all locations; construction at floor, walls, ceiling, and columns; details of lead laps and lap securing methods; fastenings, profiles, details of items and accessories penetrating the shielding materials; and any special method of const

36、ruction.SD-03 Product DataMaterialsManufacturers catalog cuts, descriptive data, and installation instructions.SD-04 SamplesLead-Lined Wood Panels200 by 250 mm 8 by 10 inch sample of each specified panel.SD-06 Test ReportsTesting and CertificationCopies of surveyors reports.SD-07 CertificatesMateria

37、lsCertification indicating the shielding materials supplied comply with specified quality and thicknesses.1.4 QUALIFICATIONSWork shall be performed by a company which specializes in the type of shielding work required by the Contract documents. Company shall have a minimum of 5 _ years of documented

38、 successful experience.1.5 DELIVERY, STORAGE, AND HANDLINGDeliver materials in the original containers bearing the name of the manufacturer and brand name. Store shielding materials off the ground under watertight cover. Handle materials preventing damage to edges, ends or surfaces in conformance wi

39、th 29 CFR 1910.1025. Remove damaged materials from the premises. Leave protective paper on acrylic panels until installation is complete.1.6 WARRANTYLead sheet shielding materials shall be warranted against sagging and curling for 10 _ years.SECTION 13 49 19 Page 7Provided by IHSNot for ResaleNo rep

40、roduction or networking permitted without license from IHS-,-,-PART 2 PRODUCTS2.1 LEAD SHEETProvide Lead sheet shall conform to ASTM B 749, Grade C, thickness as shown.2.2 LEAD-LINED CONCRETE MASONRY UNITS*NOTE: Coordinate the requirements of this Section with Section 04 20 00 MASONRY. Lead-lined ma

41、sonry units have a broad range of lead thicknesses. Lead-lined masonry units offer the advantages that they are relatively simple to construct, provide considerable structural strength, and may be surfaced easily with plaster. However, the cost is considerably higher (up to a specific kV) than using

42、 lead-lined wallboard, lath, panels, concrete, or earth.*Provide lead-lined concrete masonry units conforming to ASTM C 129, Type 1. Each unit shall have a single thickness of unpierced lead sheet bonded or anchored permanently in the center of the unit/block. Construct blocks to provide an effectiv

43、e lead lap between adjoining blocks either by the overlapping of lead in adjoining blocks or by lead bars at block joints when erected. Nominal dimensions for full-size units shall be 300 by 300 by 100 150 mm 12 by 12 by 4 6 inch. Nominal dimensions for half-size units shall be 150 by 300 by 100 150

44、 mm 6 by 12 by 4 6 inch. Units 100 mm 4 inch thick shall be used for shielding requirements up to 6 mm 1/4 inch of lead, and 150 mm 6 inch thick units shall be used for shielding requirements above 6 mm 1/4 inch of lead.2.3 LEAD-LINED WOOD PANELS*NOTE: When a matching finish is not required, specify prefinished panels.*Lead-lined panels shall be unpierced