1、ASD-STAN STANDARD NORME ASD-STAN ASD-STAN NORM prEN 2267-002 Edition P 5 November 2013 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATIONRue Montoyer 10 - 1000 Brussels - Tel. 32 2 775 8126 - Fax. 32 2 775 8131 - www.asd-stan.orgICS: 49.060 Supersedes edition P
2、 4 of February 2011 and will supersede EN 2267-002:2012Descriptors: ENGLISH VERSION Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 002: General Srie arospatiale Cbles, lectriques, dusage gnral Tempratures de fonctionnement comprises entre
3、55 C et 260 C Partie 002 : Gnralits Luft- und Raumfahrt Leitungen, elektrisch, fr allgemeine Verwendung Betriebstemperaturen zwischen 55 C und 260 C Teil 002: Allgemeines This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries
4、Association of Europe - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed
5、 to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) f
6、or formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 1stNovembe
7、r 2013 Comments should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2013 by ASD-STAN prEN 2267-002:2013 (E) 2 Contents Page Foreword 2 1 Scope 3 2 Normative references 3 3 Terms, definitions and symbols . 4 4 List of product standards . 4 5 Material
8、s and construction . 5 6 Identification and marking 9 7 Technical specification . 10 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Pro
9、cess Manual, this standard has received approval for Publication. prEN 2267-002:2013 (E) 3 1 Scope This standard specifies the list of product standards and common characteristics of electrical cables for use in the on-board electrical systems of aircraft at operating temperatures between 55 C and 2
10、60 C (except otherwise specified in product standards). 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest
11、 edition of the referenced document (including any amendments) applies. EN 2083, Aerospace series Copper or copper alloy conductors for electrical cables Product standard EN 2084, Aerospace series Cables, electric, single-core, general purpose, with conductors in copper or copper alloy Technical spe
12、cification EN 2235, Aerospace series Single and multicore electrical cables, screened and jacketed EN 2267-003, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 003: Ink jet printable Product standard EN 2267-004, Aerospace series Cables, el
13、ectrical, for general purpose Operating temperatures between 55 C and 260 C Part 004: CO2laser printable Product standard 1)EN 2267-005, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 005: UV laser printable Product standard EN 2267-006, A
14、erospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 006: YAG X3 laser printable Product standard 1)EN 2267-007, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 007: DMA family, single i
15、nk-jet printable and multicore assembly Product standard EN 2267-008, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 008: DM family, single UV laser printable and multicore assembly Product standard EN 2267-009, Aerospace series Cables, el
16、ectrical, for general purpose Operating temperatures between 55 C and 260 C Part 009: DRA family, single and multicore assembly Product standard EN 2267-010, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 010: DR family, single UV laser pr
17、intable Product standard EN 2267-011, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 011: DZA family, single and multicore assembly for use in low pressure atmosphere Product standard 2) 1) Published as ASD-STAN Prestandard at the date of
18、publication of this standard. http:/www.asd-stan.org/ 2) In preparation at the date of publication of this standard. prEN 2267-002:2013 (E) 4 EN 2267-012, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 012: DZ family, single UV laser print
19、able for use in low pressure atmosphere Product standard 2)EN 3475-100, Aerospace series Cables, electrical, aircraft use Test methods Part 100: General EN 3838, Aerospace series Requirements and tests on user-applied markings on aircraft electrical cables EN 4434, Aerospace series Copper or copper
20、alloy lightweight conductors for electrical cables Product standard TR 6058, Aerospace series Cable code identification list 3)3 Terms, definitions and symbols For the purposes of this document, the terms, definitions and symbols given in EN 3475-100 apply. 4 List of product standards EN 2267-003, A
21、erospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 003: Ink jet printable Product standard EN 2267-004, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 004: CO2laser printable Product
22、standard EN 2267-005, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 005: UV laser printable Product standard EN 2267-006, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 006: YAG
23、 X3 laser printable Product standard EN 2267-007, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 007: DMA family, single ink-jet printable and multicore assembly Product standard EN 2267-008, Aerospace series Cables, electrical, for genera
24、l purpose Operating temperatures between 55 C and 260 C Part 008: DM family, single UV laser printable and multicore assembly Product standard EN 2267-009, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 009: DRA family, single and multicor
25、e assembly Product standard EN 2267-010, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 010: DR family, single UV laser printable Product standard EN 2267-011, Aerospace series Cables, electrical, for general purpose Operating temperatures
26、 between 55 C and 260 C Part 011: DZA family, single and multicore assembly for use in low pressure atmosphere Product standard EN 2267-012, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 012: DZ family, single UV laser printable for use i
27、n low pressure atmosphere Product standard 3) Published as ASD-STAN Technical Report at the date of publication of this standard. http:/www.asd-stan.org/ prEN 2267-002:2013 (E) 5 5 Materials and construction 5.1 Materials These cable conductors shall be made of copper or copper alloy and nickel-plat
28、ed according to EN 2083 or EN 4434 code D (except otherwise specified in product standards). 5.2 Construction 5.2.1 Number of cores See Table 1. Table 1 Number of cores 1 2 3 4 5 6 7 8 9 10 Code A B C D E F G H J K Factor for overall dimensions 1 2,00 2,15 2,40 2,70 3,00 3,00 3,30 3,60 4,00 For two
29、cores or more: factor for mass: 1,03; factor for ohmic resistance: 1,03. prEN 2267-002:2013 (E) 6 5.2.2 Colour coding of single core cables See Tables 2 and 3. Table 2 Colour code Table 3 Colours for P, Q, R and S codes Code Colour aCode for core size Colours A Red (2) P Q R S B Blue (6) 001 White P
30、ink White Light yellow C Yellow (4) 002 White White Light blue White D Green (5) 004 Light green Light green White Light green E White (9) 006 White Pink Light blue White F Black (0) 010 White White White White G Brown (1) 012 White Light green Light blue White H Orange (3) 020 White Pink White Whit
31、e J Violet (7) 030 White White White White K Grey (8) 050 White Light green White White L Not yet allocated 051 White Light green White White M 090 White White White N 140 White White White P See Table 3. 220 White White White Q See Table 3. 340 White White White R See Table 3. S See Table 3. T See
32、Table 7. U Not yet allocated V W aFor information: international colour code prEN 2267-002:2013 (E) 7 5.2.3 Colour coding of unscreened, multicore cables See Tables 4 to 6. Table 4 Code P Number of cores in cables Colours 2 Red Blue 3 Red Blue Yellow 4 Red Blue Yellow Green 5 Red Blue Yellow Green W
33、hite 6 Red Blue Yellow Green White Black 7 Red Blue Yellow Green White Black Brown 8 Red Blue Yellow Green White Black Brown Orange 9 Red Blue Yellow Green White Black Brown Orange Violet 10 Red Blue Yellow Green White Black Brown Orange Violet Grey NOTE Jacket (if requested): codes 002/006/012 ligh
34、t blue, other codes: white. Table 5 Code Q Number of cores in cables Band group configuration Number of rings Wide Narrow 1 No ring on the first core 0 0 2 0 2 3 0 3 4 0 4 5 0 5 6 0 6 7 0 7 8 1 1 9 1 2 10 1 3 Marking with colour rings Basic colour of cores: pink for codes 001/006/020 white for codes
35、 002/010/030 light green for codes 004/012/050/051 prEN 2267-002:2013 (E) 8 Colour of rings: green Arrangement of colour rings (see Figure 1): 2nd core 3rd core 4th core 8th core Key 1 12 mm to 17 mm 2 1,5 mm to 3 mm 3 3,5 mm to 5 mm 4 3 mm to 6 mm Figure 1 Each ring shall cover at least 3/4 of the
36、circumference. The wide rings shall be twice the width of the narrow rings. Table 6 Code R Number of cores in cables Colours 2 White Blue 3 White Blue Yellow 4 White Blue Yellow Green prEN 2267-002:2013 (E) 9 Table 7 Code T Number of cores in cables White insulation with alphabetical colour code mar
37、king 2 R B 3 R B Y 4 R B Y G 5 R B Y G W 6 R B Y G W Bk 7 R B Y G W Bk Bn 8 R B Y G W Bk Bn O 9 R B Y G W Bk Bn O V 10 R B Y G W Bk Bn O V Gy NOTE Instead of coloured insulation, each core shall be marked with the corresponding letter and following the dedicated marking length of Figure 1 Key 1. 6 I
38、dentification and marking The identification and marking of cables by the manufacturer shall be in accordance with EN 2084. As the designation, required for orders, is generally too long for use in electrical drawings, a shorter cross designation (without colour information) is given in TR 6058 plus
39、 the corresponding nearest AWG (gauge code). EXAMPLE Designation: EN 2267-007A006P Cross reference: DM A 20 This shorter designation is used for identification and marking as in the following example (see Figure 3): EN DM A 20 FR A 98 Reference to EN standard cable 4 spaces 4)Type code Specific code
40、 Gauge code Manufacturer country code Manufacturer code Year of manufacturing 4) Space are mandatory, with a possible exception for the second one. prEN 2267-002:2013 (E) 10 Figure 2 For multicore cable with jacket, the marking shall be optional on core(s) and mandatory on jacket. For multicore cabl
41、e without jacket, each core shall be marked with its own designation. The cables (single core or jacketed cable) shall be capable of being printed with the user-applied markings according to EN 3838. Specific marking length (Code T): EXAMPLE Designation: EN 2267-011A030T Cross reference: DZ A 12 Figure 3 7 Technical specification See EN 2084 and EN 2235.