1、ASD STANDARD NORME ASD ASD NORM prEN 2997-016 Edition P 1 December 2009 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATIONAvenue de Tervuren, 270 - B-1150 Brussels - Tel. 32 2 775 8126 - Fax. 32 2 775 8131 - www.asd-stan.orgICS: 49.060 Descriptors: ENGLISH VERS
2、ION Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures 65 C to 175 C continuous, 200 C continuous, 260 C peak Part 016: Plug with integrated accessory Product standard Srie arospatiale Connecteurs lectriques circu
3、laires accouplement par bague filete, rsistant au feu ou non, tempratures dutilisation 65 C 175 C continu, 200 C continu, 260 C en pointe Partie 016 : Fiche avec accessoire intgr Norme de produit Luft- und Raumfahrt Elektrische Rundsteckverbinder mit Schraubkupplung, feuerbestndig oder nicht feuerbe
4、stndig, Betriebstemperaturen 65 C bis 175 C konstant, 200 C konstant, 260 C Spitze Teil 016: Freier Steckverbinder, integriertes Endgehuse Produktnorm This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europ
5、e - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that i
6、nterchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and t
7、ransformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 15 December 2009 Comments shou
8、ld be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2009 by ASD-STAN prEN 2997-016:2009 (E) 2 Contents Page Foreword2 1 Scope 3 2 Normative references 3 3 Terms and definitions .4 4 Required characteristics.4 5 Designation 5 6 Marking .7 7 Technical spe
9、cification .7 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. prEN
10、2997-016:2009 (E) 3 1 Scope This standard specifies the characteristics of plugs with integrated accessory in the family of circular electrical connectors coupled by threaded ring. It applies to the class defined in Table 2. For contacts, filler plugs associated with this plug, see EN 2997-002. For
11、receptacles, see EN 2997-003 to EN 2997-007, EN 2997-014, EN 2997-015 and for protective covers, see EN 2997-010. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated refere
12、nces, the latest edition of the referenced document (including any amendments) applies. EN 2997-001, Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures 65 C to 175 C continuous, 200 C continuous, 260 C peak Part 0
13、01: Technical specification.EN 2997-002, Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures 65 C to 175 C continuous, 200 C continuous, 260 C peak Part 002: Specification of performance and contact arrangements. E
14、N 2997-003, Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures 65 C to 175 C continuous, 200 C continuous, 260 C peak Part 003: Square flange receptacle Product standard. EN 2997-004, Aerospace series Connectors,
15、electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures 65 C to 175 C continuous, 200 C continuous, 260 C peak Part 004: Jam-nut mounted receptacle Product standard. EN 2997-005, Aerospace series Connectors, electrical, circular, coupled by thread
16、ed ring, fire-resistant or non fire-resistant, operating temperatures 65 C to 175 C continuous, 200 C continuous, 260 C peak Part 005: Hermetic square flange receptacle Product standard. EN 2997-006, Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non f
17、ire-resistant, operating temperatures 65 C to 175 C continuous, 200 C continuous, 260 C peak Part 006: Hermetic jam-nut mounted receptacle Product standard.EN 2997-007, Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temper
18、atures 65 C to 175 C continuous, 200 C continuous, 260 C peak Part 007: Hermetic receptacle with round flange attached by welding or brazing Product standard.EN 2997-010, Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temp
19、eratures 65 C to 175 C continuous, 200 C continuous, 260 C peak Part 010: Protective cover for plug Product standard. EN 2997-014, Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures 65 C to 175 C continuous, 200 C
20、 continuous, 260 C peak Part 014: Square flange receptacle with intregrated accessory Product standard EN 2997-015, Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures 65 C to 175 C continuous, 200 C continuous, 26
21、0 C peak Part 015: Jam-nut mounted receptacle with intregrated accessory Product standard EN 3155-002, Aerospace series Electrical contacts used in elements of connection Part 002: List and utilization of contacts. prEN 2997-016:2009 (E) 4 3 Terms and definitions For the purposes of this standard, t
22、he terms and definitions given in EN 2997-001 apply. 4 Required characteristics 4.1 Dimensions and mass See Figure 1 and Table 1. Dimensions are in millimetres; they apply after surface treatment. Key 1 See EN 2997-001. 2 Identity marking and blue rear release indicator band here Figure 1 prEN 2997-
23、016:2009 (E) 5 Table 1 C Mass agmax. Housing size Stainless steel Aluminium alloy 08 21,30 45 18 10 24,90 62 26 12 29,60 71 30 14 31,24 85 46 16 34,42 100 48 18 37,34 113 52 20 41,91 125 56 22 44,07 141 76 24 47,24 157 79 28 55,24 192 124 aMass without contact. 4.2 Material, surface treatment See Ta
24、ble 2. 4.3 Main general characteristics See EN 2997-002. 4.4 Possible combinations of plugs and receptacles See EN 2997-002. 5 Designation EXAMPLE Description block ELECTRICAL CONNECTOR, PLUG Identity block EN2997SEC0898F8 Number of the basic standard Class (see Table 2) Plug with integrated accesso
25、ry (see EN 2997-002) Housing size and contact arrangement (see EN 2997-002) Type of contact (see Table 3) Polarization (see EN 2997-002) NOTE If necessary, the code I9005 shall be placed between the description block and the identity block. prEN 2997-016:2009 (E) 6 Table 2 Class Model description W
26、Sealed plug with housing (shell) in olive-green cadmium-plated aluminium alloy, conducting finish, 500 h resistance to salt mist, crimp contacts, maximum operating temperature 175 C continuous WS Sealed plug with housing (shell) in olive-green cadmium-plated aluminium alloy, conducting finish, 500 h
27、 resistance to salt mist, crimp contacts, with ground-spring-system, maximum operating temperature 175 C continuous K Sealed plug with housing (shell) in passivated stainless steel, 500 h resistance to salt mist, crimp contacts, fire-resistant, maximum operating temperature 200 C continuous R Sealed
28、 plug with housing (shell) in nickel-plated aluminium alloy, 48 h resistance to salt mist, crimp contacts, maximum operating temperature 200 C continuous RS Sealed plug with housing (shell) in nickel-plated aluminium alloy, 48 h resistance to salt mist, crimp contacts, with grounding-spring-system,
29、maximum operating temperature 200 C continuous S Sealed plug with housing (shell) in passivated stainless steel, 500 h resistance to salt mist, crimp contacts, fire-resistant, with grounding-spring-system, maximum operating temperature 200 C continuous KE Sealed plug with housing (shell) in passivat
30、ed stainless steel, 500 h resistance to salt mist, crimp contacts, fire-resistant, maximum operating temperature 260 C peak KV Sealed plug with housing (shell) in passivated stainless steel, 500 h resistance to salt mist, crimp contacts, fire-resistant, high vibrations, maximum operating temperature
31、 260 C peak SV Sealed plug with housing (shell) in passivated stainless steel, 500 h resistance to salt mist, crimp contacts, fire-resistant, high vibrations, with grounding-spring-system, maximum operating temperature 260 C peak SE Sealed plug with housing (shell) in passivated stainless steel, 500
32、 h resistance to salt mist, crimp contacts, fire-resistant, with grounding-spring-system, maximum operating temperature 260 C peak Table 3 Contacts Delivered without contact Delivered with contacts with standard barrels aEN 3155-XXXX2222 EN 3155-XXXX2020 EN 3155-XXXX1616 EN 3155-XXXX1212 Delivered w
33、ith specific contacts size 20 with special barrel aEN 3155-XXXX2018 b Male A M C Female B F D aSee EN 3155-002. bOnly affects size 20 contact arrangements. prEN 2997-016:2009 (E) 7 6 Marking Unless there are other specific contractual requirements, the marking shall include: the identity block as de
34、fined in Clause 5, except for the 13th (classes W, K, R and S) or 14th(all other classes) character which shall be marked according to Table 4; the date of manufacture (year, week); the manufacturers name or trade mark. Table 4 13th or 14th character of the identity block For A, M, C a M For B, F, D aF aSee Table 3. 7 Technical specification See EN 2997-001.