1、ASD-STAN STANDARD NORME ASD-STAN ASD-STAN NORM prEN 3682-006 Edition P 2 January 2012 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATIONAvenue de Tervuren, 270 - B-1150 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 775 8131 - www.asd-stan.orgICS: 49.060 Superse
2、des edition P 1 of September 2002 and will supersede EN 3682-006:2006 Descriptors: ENGLISH VERSION Aerospace series Connectors, plug and receptacle, electrical, rectangular, interchangeable insert type, rack to panel, operating temperature 150 C continuous Part 006: Size 3 receptacle Product standar
3、d Srie arospatiale Connecteurs lectriques rectangulaires rackables, fiches et embases, inserts interchangeables, temprature dutilisation 150 C continu Partie 006 : Botier femelle taille 3 Norme de produit Luft- und Raumfahrt Elektrischer Rechtecksteckverbinder, freie und feste Bauform, auswechselbar
4、e Isolierkrper, Gestell-Einschubsteckverbinder, Betriebstemperatur 150 C konstant Teil 006: Fester Steckverbinder Gre 3 Produktnorm This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization
5、). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability i
6、s affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to fu
7、ll European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 1 January 2012 Comments should be sent within six
8、 months after the date of publication to ASD-STAN Electrical Domain Copyright 2012 by ASD-STAN prEN 3682-006:2012 (E) 2 Contents Page Foreword 2 1 Scope 3 2 Normative references 3 3 Terms and definitions .3 4 Required characteristics .4 5 Designation 8 6 Marking .8 7 Technical specification .8 Forew
9、ord This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. prEN 3682-006:2012 (E) 3
10、 1 Scope This standard defines the size 3 receptacle used in the family of rectangular electrical connectors for rack to panel, with interchangeable inserts. The plug corresponding to this receptacle is defined in EN 3682-007. 2 Normative references The following referenced documents are indispensab
11、le for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 3682-001, Aerospace series Connectors, plug and receptacle, electrical, rectangular, interchange
12、able insert type, rack to panel, operating temperature 150 C continuous Part 001: Technical specification EN 3682-002, Aerospace series Connectors, plug and receptacle, electrical, rectangular, interchangeable insert type, rack to panel, operating temperature 150 C continuous Part 002: Specification
13、 of performance and contact arrangements EN 3682-007, Aerospace series Connectors, plug and receptacle, electrical, rectangular, interchangeable insert type, rack to panel, operating temperature 150 C continuous Part 007: Size 3 plug Product standard ISO 263, ISO inch screw threads General plan and
14、selection for screws, bolts and nuts Diameter range 0,06 to 6 in 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 3682-001 apply. prEN 3682-006:2012 (E) 4 4 Required characteristics 4.1 Dimensions See Figures 1 to 3. Dimensions are in millimetres. Key
15、1 axis of T see note 2 22 holes 3,96 3,71 3 axis of S see note NOTE See EN 3682-001 Tables 2, 3 and 5 for S and T references. Figure 1 Connector front mating face prEN 3682-006:2012 (E) 5 aFor arrangements with size 22 contacts. bFor arrangements without size 22 contacts. Figure 2 prEN 3682-006:2012
16、 (E) 6 Key 1 16 Philips screw 4-40 UNC 2A 2 cavities identification on the front and the rear of the flange 3 insert retention device (8 places) 4 marking of trademark of manufacture and part number on right or left of the flange NOTE See EN 3682-001 Tables 2, 3 and 5 for S and T references. aSee IS
17、O 263. Figure 3 prEN 3682-006:2012 (E) 7 4.2 Recommended panel cut-out and mounting of connectors Dimensions in millimetres Key 1 22 holes 4,58 4,22 NOTE The W reference represents the width of the equipment. Figure 4 prEN 3682-006:2012 (E) 8 5 Designation EXAMPLE Description block ELECTRICAL CONNEC
18、TOR, SIZE 3 RECEPTACLE Identity block EN 3682 R 3 200 A 01 L Standard reference Housing Type (R Receptacle, P Plug) Housing size Connector insert combination code A: coaxial, triaxial and quadrax contacts not connected to the ground Polarization (see EN 3682-002) Contact delivery If left blank: inse
19、rt delivered with contacts except coaxial, triaxial and quadrax contacts; L: insert delivered without contacts. 6 Marking Housing identification marking, as specified in Clause 5, should be applied in the position shown on the corresponding drawing. When polarization code is 00, the polarization code is not included in the connector marking. In addition, marking shall show: date of manufacture (year week); manufacturer name or trademark. 7 Technical specification See EN 3682-001.