1、ASD STANDARD NORME ASD ASD NORM prEN 4639-102 Edition P 1 September 2006 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Gulledelle 94 - B-1200 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 763 3565 - www.asd-stan.orgICS: 49.060 Descriptors: ENGLISH VERSION
2、Aerospace series Connectors, optical, rectangular, modular, multicontact, 1,25 diameter ferrule, with removable alignment sleeve holder Part 102 : Optical contact for cable EN 4641-102 Operating temperatures between 55 C and 100 C Product standard Srie arospatiale Connecteurs optiques rectangulaires
3、, modulaires multivoies, frule 1,25, quips dun porte sleeve dmontable Part 102 : Contact optique pour cble EN 4641-102 Tempratures de fonctionnement comprises entre 55 C et 100 C Norme de produit Luft- und Raumfahrt Optischer Rechtecksteckverbinder, modular, multipin, Ferrulendurchmesser 1,25 mm, de
4、montierbarer Zentrierhlsenhalter Teil 102 : Optische Kontakt fr EN 4641-102 Kabel Betriebstemperaturen zwischen 55 C und 100 C Produktnorm This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standard
5、ization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeab
6、ility is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformatio
7、n to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 30 September 2006 Comments should be sent
8、within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2006 by ASD-STAN prEN 4639-102:20062 Contents Page Foreword . 2 1 Scope 3 2 Normative references 3 3 Fibre optic contact designation and dimensions 3 3.1 Contact designation 3 3.2 Contact dimensions 3 3.3 Cable d
9、esignation . 4 4 Technical specification. 5 5 Tests according to EN 2591 series 5 6 Assembly process instructions. 6 6.1 Cleaning instructions 6 6.2 Tooling 6 6.3 Termination instructions 6 7 Designation 6 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrica
10、l Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. prEN 4639-102:20063 1 Scope This standard defines the performance and dimensions of optical physical contact for
11、EN 4641-102 cable specification. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) ap
12、plies. EN 2591-*, Aerospace series Elements of electrical and optical connection Test methods. EN 4639-001, Aerospace series Connectors, optical, rectangular, modular, multicontact, 1,25 diameter ferrule, with removable alignment sleeve holder Part 001: Technical specification. 1) EN 4639-002, Aeros
13、pace series Connectors, optical, rectangular, modular, multicontact, 1,25 diameter ferrule, with removable alignment sleeve holder Part 002: List of product standards.1) EN 4641-102, Aerospace series Cable optical 125 m diameter cladding Part 102: Outer diameter 1,8 mm, semi loose structure Product
14、standard. 2) MIL-I-81969/14, Installing and removal tools, connector electrical contact, type III, class 2, composition B. 3) TR XXXX, Aerospace series Fibres and cables, optical aircraft use Technical Report Termination procedure for EN 4639 10X contact. 2) 3 Fibre optic contact designation and dim
15、ensions 3.1 Contact designation See Table 1. Table 1 Contact designation Contact type Cable structure type Fibre optic contact for semi loose structure cable ML EN 4641-102 3.2 Contact dimensions Dimensions and tolerances are in millimetres, see Figure 1. * All parts quoted in this standard. 1) Publ
16、ished as ASD Prestandard at the date of publication of this standard. 2) In preparation 3) Published by: Department of Defense (DOD), the Pentagon, Washington D.C. 20301 USA. prEN 4639-102:20064 Spring force when connector is mated: Typical: 5,65 N (minimum 4,6 N, maximum 6,7 N) View A Multimode fer
17、rule for 125 m fibre Key 1 Optical reference plane 2 2,95 max. after crimping 3 13,15 max. Back position 4 12,3 max. After crimping Free position Figure 1 3.3 Cable designation Specified in EN 4641-102. 1 2 A 3 4 prEN 4639-102:20065 4 Technical specification This component is qualified as part of a
18、complete connector assembly when tested according to the qualification requirements of EN 4639-001 and the applicable product standards. 5 Tests according to EN 2591 series The tests of EN 2591, applicable in the context of this standard as well as the details necessary for implementing them and for
19、 inspecting connector characteristics, are given in Table 2. Environmental tests are specified in EN 4639-001. Table 2 EN 2591- Test Details 6301 Endurance at temperature 1 000 hours at 100 C 301 Endurance at temperature Not applicable 304 Damp heat steady state Temperature of 40 C and 93 % of humid
20、ity 6305 Rapid change of temperature 10 cycles, TA = 100 C, TB = 55 C 6307 Salt mist Mated connectors Severity according to environmental class of the connector 309 Dry heat Not applicable 310 Cold Not applicable 311 Low air pressure Not applicable 313 Driving rain (artificial) Not applicable 6316 O
21、zone resistance Not applicable 320 Simulated solar radiation at ground level Not applicable 6401 Acceleration steady state Not applicable 6405 Axial load 100 N maintained for 1 minute, 3 cycles 6406 Mechanical endurance 500 mating/unmating cycles 407 Durability of contact retention system and seals
22、(maintenance aging) Applicable 601 Insertion loss 0,7 dB max. during and after tests 602 Variation of attenuation and optical Method A, IL maximum = 0,7 dB 604 Cleaning capability of optical face Applicable 605 Return loss RL 21 dB 607 Immunity to ambient light coupling Not applicable 608 Nuclear ra
23、diation Not applicable 609 Effectiveness of cable attachment Cable cyclic flexing 100 cycles at load of 40 N 610 Effectiveness of cable attachment Cable pulling Method B, 68 N tensile load, 1 minute, 3 pulls 611 Effectiveness of cable attachment Cable torsion 100 cycles at load of 40 N 612 Effective
24、ness of cable attachment Cable axial compression Compression force of 10 N for 2 minutes 613 Impact test Severity: light 615 Connection integrity at temperature Not applicable 617 Temperature cycling 10 cycles, TA = 100 C, TB = 55 C prEN 4639-102:20066 6 Assembly process instructions 6.1 Cleaning in
25、structions This fibre optic connector provides an easy access to the optical faces and sleeves for cleaning. Cleaning operation could be proceeded as follows: 1. Unmate the pair of connectors. 2. Remove the sleeve holder (For the female insert). 3. Use cleaning stick and pipe with ethylic alcohol (o
26、r equivalent) to clean the front face of the optical contact and the inside of the sleeve without removing the contacts from their cavities. 4. Use dry clean air can for drying. 5. Inspect optical face 6. Install the sleeve holder (For the female insert). 7. Mate the pair of connectors. See TR XXXX
27、for details. 6.2 Tooling For insertion and extraction of the optical contact use the standard tool as per MIL-I-81969/14-3 standard (P/N for size 16). 6.3 Termination instructions General termination operation: 1. Pass the crimping ferrule on the cable. 2. Strip off the cable up to the 125 m fibre.
28、3. Inject epoxy glue with adapted syringe inside the optical ferrule from the front side. 4. Insert the optical contact onto the fibre and the cable. 5. Slide and crimp the rear ferrule onto the body contact, the cable and its strength members. 6. Cure the epoxy glue with an appropriate cure oven. 7. Cleave the fibre and polish the front face of the optical contact. 8. Inspection and control. See TR XXXX for details. 7 Designation EXAMPLE Description block FIBER OPTIC CONTACT Identity bloc EN4639-102B Number of the basic standard Contact type Cable designation (see EN 4639-002)