1、ASD-STAN STANDARD NORME ASD-STAN ASD-STAN NORM prEN 4644-001 Edition P 3 September 2015 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Rue Montoyer 10 - 1000 Brussels - Tel. 32 2 775 8126 - Fax. 32 2 775 8131 - www.asd-stan.org ICS: 49.060 Supersedes editio
2、n P 2 of September 2010 and will supersede EN 4644-001:2012 Descriptors: ENGLISH VERSION Aerospace series Connector, electrical and optical, rectangular, modular, rectangular inserts, operating temperature 175 C (or 125 C) continuous Part 001: Technical specification Srie arospatiale Connecteur, lec
3、trique et optique, rectangulaire, modulaire, inserts rectangulaires, temprature de fonctionnement 175 C (ou 125 C) continu Partie 001 : Spcification technique Luft- und Raumfahrt Elektrische und optische Rechtecksteckverbinder, modular, rechteckige Kontakteinstze, Dauerbetriebstemperatur 175 C (oder
4、 125 C) konstant Teil 001: Technische Lieferbedingungen This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization). It is published for the needs of the European Aerospace Industry. It has
5、been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the sta
6、ndard. After examination and review by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement t
7、he EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 1st September 2015 Comments should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copy
8、right 2015 by ASD-STAN prEN 4644-001:2015 (E) 2 Contents Page Foreword 2 Introduction .3 1 Scope 3 2 Normative references 3 3 Terms and definitions .4 4 Description .5 5 Design 17 6 Dimensions and masses 18 7 Tests . 79 8 Quality assurance . 92 9 Designation and marking . 98 10 Delivery conditions .
9、 98 11 Packaging 98 12 Storage . 98 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval
10、for Publication. prEN 4644-001:2015 (E) 3 Introduction The connectors defined by this standard are suitable for use on board of commercial and military aircraft for both disconnect panel and rack and panel applications in severe environmental conditions. 1 Scope This standard specifies the required
11、characteristics, the condition for qualification, acceptance and quality assurance for electrical and optical rectangular connectors with single or multiple removable rectangular inserts for use in a temperature range from 65 C to 175 C continuous for electrical contact. This family of connectors is
12、 particularly suitable for aeronautic use in zones of severe environmental conditions on board aircraft, applying EN 2282. Inserts for fiber optic contacts or mixing fiber optic contacts and electrical contacts are described in EN 4639-002. 2 Normative references The following documents, in whole or
13、 in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2267-003, Aerospace series Cables, elect
14、rical, for general purpose Operating temperatures between 55 C and 260 C Part 003: Ink jet printable Product standard EN 2282, Aerospace series Characteristics of aircraft electrical supplies EN 2591 (all parts), Aerospace series Elements of electrical and optical connection Test methods EN 3155-002
15、, Aerospace series Electrical contacts used in elements of connection Part 002: List and utilization of contacts EN 3909, Test fluids for electrical and optical components and sub-assemblies EN 4530-002, Aerospace series Sealing sleeves used in elements of connection Part 002: List and utilization o
16、f sealing sleeves EN 4639-002, Aerospace series Connectors, optical, rectangular, modular, multicontact, 1,25 mm diameter ferrule, with removable alignment sleeve holder Part 002: List of product standards EN 4644-002, Aerospace series Connector, electrical and optical, rectangular, modular, rectang
17、ular inserts, operating temperature 175 C (or 125 C) continuous Part 002: Specification of performance and contact arrangements EN 9133, Aerospace series Quality management systems Qualification procedure for aerospace standard parts MIL-HDBK-454A, General guidelines for electronic equipment 1) SAE
18、AS39029/1, Installing and removal tools, connector electrical contact, general specification for 2) SAE AS31971, Gage pin for socket contact engagement test1) 1) Published by: DoD National (US) Mil. Department of Defense http:/www.defenselink.mil/ 2) Published by: SAE National (US) Society of Automo
19、tive Engineers http:/www.sae.org/ prEN 4644-001:2015 (E) 4 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 2591-100 apply. The reference planes and axis used in this product standard are listed below: Ap : shell bottoming reference plane on male housi
20、ng. Ar : shell bottoming reference plane on female housing. Bp : vertical axis of male housing Br : vertical axis of female housing Cp : horizontal axis of male housing Cr : horizontal axis of female housing DAC: disconnect aligning housing cavity DNC: disconnect non aligning housing cavity N : extr
21、emity of insert retention clip reference plane P : front face of hard insert R : vertical axis of housing backshell interface RAC: rack rack and panel connectors. The current revision of this standard is describing 2 disconnect panel housing sizes and 3 rack and panel housing sizes. However, it is a
22、lso providing a design rule to extend the current range described. The design rule is based on the description of housing aligning cavities, housing non aligning cavities and a clinging dimension line; see 4.2 and 4.3 for details. These connectors have rectangular housings, removable rectangular ins
23、erts and contacts and can be fitted with rear accessories. Male and female inserts can be fitted either in the male or female housing. Depending on the housing size, the disconnect panel connectors are mated and unmated either by using a centre coupling screw or 2 quarter turn fasteners. The centre
24、coupling mechanism shall provide a total of 12 polarization positions. Housings having the quarter turn fasteners are polarized by using 2 polarizing posts and keys offering a total of 16 polarizing positions. A size 1 housing has 1 insert cavity with 1 keyway, quarter turn fasteners and 2 polarizin
25、g posts or keys. A size 2 housing has 2 insert cavities with one cavity having one keyway and the other having two keyways; a central coupling mechanism provides housing polarization. There are three rack and panel (blind mate) connector housing sizes; it is a size 2, size 3 and size 4 housing which
26、 have respectively 2, 3 and 4 insert cavities all with one keyway, three polarizing posts or keys offering 64 polarizing positions and no locking mechanism. In addition to this rack and panel use, the size 4 male connector can be mated with 2 size 2 female connector in a disconnect application by us
27、ing 2 centre coupling mechanism. These connectors use different types of contacts (signal, power, coaxial, triaxial, quadrax, etc) see EN 3155-002 and optical contacts see EN 4639-002. 4.2 Female housing 4.2.1 General For disconnect application, the following housings are described: size 1 housing h
28、as quarter turn fasteners and 2 polarization keys that can take 4 positions to polarize the housing. Size 1 female housing is panel mount connector. size 2 housing has a central coupling mechanism which can take 12 positions to polarize the housing. Size 2 female housing are either panel mount conne
29、ctor or cable connector. In addition, size 1 and 2 female housings are available with a grounding block (class B and F) or without a grounding block (class A, C and E) allowing grounding of a cable braid with a pigtail. prEN 4644-001:2015 (E) 6 For rack and panel application, the following sizes are
30、 described: size 2 housing has 3 polarization keys, each of them can take 4 positions to prevent mismating between male and female housing. size 3 housing has 3 polarization keys, each of them can take 4 positions to prevent mismating between male and female housing. size 4 housing has 3 polarizatio
31、n keys, each of them can take 4 positions to prevent mismating between male and female housing. Rack and panel female housing shall be installed on the aircraft side and are cable connectors. No grounding block option is available for rack and panel housings. The insert cavities are identified on th
32、e female housing by letters A, B, C, D for size 4, letters A, B, C for size 3 letters, A, B for size 2 and no letter for size 1. The insert cavities are polarized by either one (A polarizing position) or two keyways (B polarizing position) location. Housing size 1, 3 and 4 insert cavities have one k
33、eyway. Housing size 2 insert cavity identified with letter A has one keyway and insert cavity identified with letter B has two keyways. Each insert cavity has 2 insert retaining devices allowing rear insertion and rear release of the insert. Each female housing has a grounding device ensuring electr
34、ical continuity between housings before contact mating. For each female housing, some cavities are aligning cavities and other cavities are non-aligning. Aligning cavities guaranty not only the alignment between male and female housing but also guarantee the shell to shell bottoming. Non-aligning fe
35、male housing cavities have a circular location tolerance. In order to define how alignment of the female and male housing is achieved, a dimension line between the 2 housing aligning cavities is defined. prEN 4644-001:2015 (E) 7 4.2.2 Disconnect panel female housing alignment Key 1 Dimensions for ho
36、using size 1 2 Dimension for housing size n (n 1) 3 Dimension of grounding device (optional) Figure 1 Disconnect panel female aligning cavity (DAC) prEN 4644-001:2015 (E) 8 Key 1 Dimension of grounding device (optional) Figure 2 Disconnect panel female non-aligning cavity (DNC) prEN 4644-001:2015 (E
37、) 9 4.2.3 Rack and panel female housing Key 1 Dimension for grounding device Figure 3 Rack and panel female aligning cavity (RAC) prEN 4644-001:2015 (E) 10 Key 1 Dimension for grounding device (optional) Figure 4 Rack and panel female non-aligning cavity (RNC) prEN 4644-001:2015 (E) 11 4.3 Male hous
38、ing 4.3.1 General For disconnect application, the following housings are described: size 1 male housing has quarter turn fasteners and 2 polarization post that can take 4 positions to polarize the housing. Size 1 male housing is cable connector. size 2 male housing has a central coupling mechanism w
39、hich can take 12 positions to polarize the housing. Size 2 male housing is panel mount connector or cable connector. Size 1 and 2 male housings are available with (class B and F) or without grounding block (class A, C and E) allowing grounding of a cable braid with a pigtail. For rack and panel appl
40、ication, the following housings are described: size 2 male housing has three polarization posts, each of them can take 4 positions to prevent mismating between male and female housing. size 3 male housing has three polarization posts, each of them can take 4 positions to prevent mismating between ma
41、le and female housing. size 4 male housing has three polarization post, each of them can take 4 positions to prevent mismating between male and female housing. Male housing shall be installed on equipment side and can be connected to PCB or cable harness. No grounding block option is available for r
42、ack and panel housings. The insert cavities are identified on the male housing by letters A, B, C, D for size 4, letters A, B, C for size 3, letters, A, B for size 2 and no letter for size 1. The insert cavities are polarized by either one or two keyways location. Housing size 1, 3 and 4 insert cavi
43、ties have one keyway. Housing size 2 insert cavity identified with letter A has one keyway and insert cavity identified with letter B has two keyways. Each insert cavity has 2 insert retaining devices allowing rear insertion and rear release of the insert. All male housing have a minimum of 1 (for s
44、ingle cavity connectors) and a maximum of 2 aligning housing cavities (see Figure 5 and Figure 7); the remaining housing cavities are non-aligning cavities (see Figure 6 and Figure 8). This principle is not valid for size 4 male housing because it can be mated with 2 size 2 female housings. Aligning
45、 cavities guaranty not only the alignment between male and female housing but also guarantee the shell to shell bottoming. Non-aligning housing cavities have a circular location. In order to define how alignment of the female and male housing is achieved, a clinging dimension line between the 2 hous
46、ing aligning cavities is defined. prEN 4644-001:2015 (E) 12 4.3.2 Disconnect panel male housing Key 1 Dimension for housing size 1 2 Dimension for housing size n (n 1) Figure 5 Disconnect panel male aligning cavity (DAC) prEN 4644-001:2015 (E) 13 Figure 6 Disconnect panel male non-aligning cavity (D
47、NC) prEN 4644-001:2015 (E) 14 4.3.3 Rack and Panel male housing Figure 7 Rack and panel male aligning cavity (RAC) prEN 4644-001:2015 (E) 15 Figure 8 Rack and panel male non-aligning cavity (RNC) 4.4 Rear accessories See EN 4644-002. 4.5 Inserts The insert assembly shall be single-bloc type design c
48、omplete with contact retention systems and appropriate seals. The female inserts use female contacts and male inserts use male contacts. These inserts use contacts of size 22, 20, 16, 12, 5 and 8. The inserts are rear release rear removable from the housing. Male and female inserts can be installed
49、either in the male or female housing. There are inserts with one polarizing rib (A polarizing position) and inserts with two polarizing ribs (B polarizing position). This means that there are inserts dedicated to housing cavities with one keyway and inserts dedicated to housing cavities with two keyways. See Table 1 below. prEN 4644-001:2015 (E) 16 Table 1 Shell size Shell cavity labelling Insert polarization