ASHRAE HVAC SYSTEMS AND EQUIPMENT IP CH 41-2012 EVAPORATIVE AIR-COOLING EQUIPMENT.pdf

上传人:李朗 文档编号:455067 上传时间:2018-11-23 格式:PDF 页数:10 大小:1.11MB
下载 相关 举报
ASHRAE HVAC SYSTEMS AND EQUIPMENT IP CH 41-2012 EVAPORATIVE AIR-COOLING EQUIPMENT.pdf_第1页
第1页 / 共10页
ASHRAE HVAC SYSTEMS AND EQUIPMENT IP CH 41-2012 EVAPORATIVE AIR-COOLING EQUIPMENT.pdf_第2页
第2页 / 共10页
ASHRAE HVAC SYSTEMS AND EQUIPMENT IP CH 41-2012 EVAPORATIVE AIR-COOLING EQUIPMENT.pdf_第3页
第3页 / 共10页
ASHRAE HVAC SYSTEMS AND EQUIPMENT IP CH 41-2012 EVAPORATIVE AIR-COOLING EQUIPMENT.pdf_第4页
第4页 / 共10页
ASHRAE HVAC SYSTEMS AND EQUIPMENT IP CH 41-2012 EVAPORATIVE AIR-COOLING EQUIPMENT.pdf_第5页
第5页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、41.1CHAPTER 41EVAPORATIVE AIR-COOLING EQUIPMENTDirect Evaporative Air Coolers 41.1Indirect Evaporative Air Coolers 41.3Indirect/Direct Combinations . 41.5Air Washers. 41.6Humidification/Dehumidification . 41.7Sound Attenuation . 41.9Maintenance and Water Treatment. 41.9HIS chapter addresses direct a

2、nd indirect evaporative equip-Tment, air washers, and their associated equipment used for aircooling, humidification, dehumidification, and air cleaning. Resi-dential and industrial humidification equipment are covered inChapter 22.Principal advantages of evaporative air conditioning include Substan

3、tial energy and cost savingsReduced peak power demandImproved indoor air qualityLife-cycle cost effectivenessEasily integrated into built-up systemsWide variety of packages availableProvides humidification and dehumidification when neededEasy to use with direct digital control (DDC)Reduced pollution

4、 emissionsNo chlorofluorocarbon (CFC) useFor same amount of cooling, less water is evaporated than withconventional air conditioningSound attenuationPackaged direct evaporative air coolers, air washers, indirectevaporative air coolers, evaporative condensers, vacuum coolingapparatus, and cooling tow

5、ers exchange sensible heat for latent heat.This equipment falls into two general categories: those for (1) aircooling and (2) heat rejection. This chapter addresses equipmentused for air cooling.Adiabatic evaporation of water provides the cooling effect ofevaporative air conditioning. In direct evap

6、orative cooling, waterevaporates directly into the airstream, reducing the airs dry-bulbtemperature and raising its humidity level. Direct evaporative equip-ment cools air by direct contact with the water, either by an extendedwetted-surface material (e.g., packaged air coolers) or with a seriesof s

7、prays (e.g., an air washer).In indirect evaporative cooling, secondary air removes heatfrom primary air using a heat exchanger. In one indirect method,water is evaporatively cooled by a cooling tower and circulatesthrough one side of a heat exchanger. Supply air to the space passesover the other sid

8、e of the heat exchanger. In another commonmethod, one side of an air-to-air heat exchanger is wetted andremoves heat from the conditioned supply airstream on the dry side.Even in regions with high wet-bulb temperatures, indirect evapora-tive cooling can be economically feasible. This is especially t

9、rue ifbuilding return air from an air-conditioned building is used on thewet side of an air-to-air heat exchanger. The return airs lower wet-bulb temperature, which derives from mechanical refrigeration,may be used to extend indirect evaporative cooling performance inmore humid climates.It is often

10、desirable to combine the effects of direct and indirectevaporative processes (indirect/direct). The first stage (indirect)sensibly cools the air, thereby lowering its wet-bulb temperature,and passes it through the second stage (direct) where it is evapora-tively cooled further. Combination systems u

11、se both direct and indi-rect evaporative principles as well as secondary heat exchangers andcooling coils. Secondary heat exchangers enhance both cooling andheat recovery (in winter), and the coils provide additional cooling/dehumidification as needed. Used in both dual-duct and unitary sys-tems, se

12、condary heat exchangers save energy by eliminating theneed for terminal reheat in some applications (in such systems, airmay exit below the initial wet-bulb temperature).Direct evaporative coolers for residences in low-wet-bulb re-gions typically require 70% less energy than direct-expansion aircond

13、itioners. For instance, in El Paso, Texas, the typical evaporativecooler consumes 609 kWh per cooling season, compared to3901 kWh per season for a typical vapor-compression air condi-tioner with a seasonal energy-efficiency ratio (SEER) of 10. Thisequates to an average demand of 0.51 kW based on 120

14、0 operatinghours, compared to an average of 3.25 kW for a vapor-compressionair conditioner. Depending on climatic conditions, many buildings can use indi-rect/direct evaporative air conditioning to provide comfort cooling.Indirect/direct systems achieve a 40 to 50% energy savings in mod-erate humidi

15、ty zones (Foster and Dijkstra 1996).DIRECT EVAPORATIVE AIR COOLERSIn direct evaporative air cooling, air is drawn through porouswetted pads or a spray and its sensible heat energy evaporates somewater. Heat and mass transfer between the air and water lowers theair dry-bulb temperature and increases

16、the humidity at a constantenthalpy (wet-bulb temperature remains nearly constant). The dry-bulb temperature of the nearly saturated air approaches the ambientairs wet-bulb temperature.Saturation effectiveness is a key factor in determining evaporativecooler performance. The extent to which the leavi

17、ng air temperaturefrom a direct evaporative cooler approaches the thermodynamic wet-bulb temperature of the entering air defines the direct saturationefficiency e,expressed ase= 100 (1)wheree= direct evaporative cooling saturation efficiency, %t1= dry-bulb temperature of entering air, Ft2= dry-bulb

18、temperature of leaving air, F= thermodynamic wet-bulb temperature of entering air, FThe preparation of this chapter is assigned to TC 5.7, Evaporative Cooling.t1t2t1ts-ts41.2 2012 ASHRAE HandbookHVAC Systems and EquipmentAn efficient wetted pad (with high saturation efficiency) can re-duce the air d

19、ry-bulb temperature by as much as 95% of thewet-bulb depression (ambient dry-bulb temperature less wet-bulbtemperature), although an inefficient and poorly designed pad mayonly reduce this by 50% or less.Although direct evaporative cooling is simple and inexpensive,its cooling effect is insufficient

20、 for indoor comfort when the ambientwet-bulb temperature is higher than about 70F; however, cooling isstill sufficient for relief cooling applications (e.g., greenhouses,industrial cooling). Direct evaporative coolers should not recircu-late indoor air; exhaust should equal incoming conditioned air.

21、Random-Media Air CoolersThese coolers contain evaporative pads, usually of aspen wood orabsorbent plastic fiber/foam (Figure 1). A water-recirculating pumplifts sump water to a distributing system, and it flows down throughthe pads back to the sump.A fan in the cooler draws air through the evaporati

22、ve pads anddelivers it for space cooling. The fan discharges either through theside of the cooler cabinet or through the sump bottom. Random-media packaged air coolers are made as small tabletop coolers (50to 200 cfm), window units (100 to 4500 cfm), and standard duct-connected coolers (5000 to 18,0

23、00 cfm). Cooler selection is basedon a capacity rating from an independent agency.When clean and well maintained, commercial random-media aircoolers operate at approximately 80% effectiveness and reduce10 m and larger particles in the air. In some units, supplementaryfilters are added to reduce the

24、particle count of delivered air whenthe unit is operating with or without water circulation. Evaporativepads may be chemically treated to increase wettability. An additivemay be included in the fibers to help them resist attack by bacteria,fungi, and other microorganisms.Random-media cooler designs

25、with face velocity of 100 to250 fpm with a pressure drop of 0.1 in. of water are the norm. Aspenfibers packed to approximately 0.3 to 0.4 lb/ft2of face area, basedon a 2 in. thick pad, are standard. Pads mount in removable louveredframes, which are usually made of painted galvanized steel ormolded p

26、lastic. Troughs distribute water to the pads. A centrifugalpump with a submerged inlet delivers water through tubes that pro-vide an equal flow of water to each trough. It is important to ther-mally protect the pump motor. The sump or water tank has a watermakeup connection, float valve, overflow pi

27、pe, and drain. It isimportant to provide bleed water or a timed dump of the sump (orboth) to prevent build-up of minerals, dirt, and microbial growth.The fan is usually a forward-curved, centrifugal fan, complete withmotor and drive. The V-belt drive may include an adjustable-pitchmotor sheave to al

28、low fan speed to increase to use the full motorcapacity at higher airflow resistance. The motor enclosure may bedrip-proof, totally enclosed, or a semi-open type specificallydesigned for evaporative coolers.Rigid-Media Air CoolersBlocks of corrugated material make up the wetted surface ofrigid-media

29、 direct evaporative air coolers (Figure 2). Materialsinclude cellulose, plastic, and fiberglass, treated to absorb water andresist weathering effects. The medium is cross corrugated to maxi-mize mixing of air and water. In the direction of airflow, the depthof medium is commonly 12 in., but it may b

30、e between 4 and 24 in.,depending on the desired thermal performance. The medium has thedesirable characteristics of low resistance to airflow, high saturationeffectiveness, and self-cleaning abilities. The standard design facevelocity of a rigid medium is 400 to 600 fpm. Static pressure loss fora 12

31、 in. media pad varies from 0.14 to 0.3 in. of water at sea level.Direct evaporative air coolers using this material can handle asmuch as 600,000 cfm and may include an integral fan. Saturationeffectiveness varies from 70 to over 95%, depending on media depthand air velocity. Air flows horizontally w

32、hile the recirculating waterflows vertically over the medium surfaces by gravity feed from aflooding header and water distribution chamber. The header may beconnected directly to a pressurized water supply for once-throughoperation (e.g., gas turbines, cleanrooms, data centers), or a pumpmay recircu

33、late the water from a lower reservoir constructed ofheavy-gage corrosion-resistant material. The reservoir is also fittedwith overflow and positive-flowing drain connections. The uppermedia enclosure is of reinforced galvanized steel or other corrosion-resistant sheet metal, or of plastic.Flanges at

34、 the entering and leaving faces allow connection ofductwork. In recirculating water systems, a float valve maintainsproper water level in the reservoir, makes up water that has evapo-rated, and supplies fresh water for dilution to prevent an overcon-centration of solids and minerals. Because the wat

35、er recirculationrate is low and because high-pressure nozzles are not needed to sat-urate the medium, pumping power is low compared to spray-filledair washers with equivalent evaporative cooling effectiveness.Remote Pad Evaporative Cooling EquipmentGreenhouses, poultry or hog buildings, and similar

36、applicationsuse exhaust fans installed in the wall or roof of the structure. Airevaporatively cools as it flows through pads located on the other endFig. 1 Typical Random-Media Evaporative Cooler Fig. 2 Typical Rigid-Media Air CoolerEvaporative Air-Cooling Equipment 41.3of the building. Water flowin

37、g down from a perforated pipe wets thepads, with excess water collected for recirculation. In some cases,the pads are wetted with high-pressure fogging nozzles, which pro-vide additional cooling. Water for fogging nozzles must comedirectly from the fresh-water supply. The pad has an air velocity ofa

38、pproximately 150 fpm for random-media pads, 250 fpm for 4 in.rigid media, and 425 fpm for 6 in. rigid media.INDIRECT EVAPORATIVE AIR COOLERSPackaged Indirect Evaporative Air CoolersFigure 3 illustrates an indirect evaporative cooling (IEC) heatexchanger. This cross-flow, tube-type heat exchanger use

39、s a sumppump to recirculate water to wet the inside of the heat exchangertubes. A secondary-air fan causes either building return or outdoorair to flow through the inside of the tubes, causing evaporative cool-ing to occur. Outdoor air is sensibly cooled as it passes through theheat exchanger as it

40、comes into contact with tubes that are cooled byevaporative cooling on the opposite side of the tube. Latent coolingmay also occur if the secondary air wet-bulb temperature is belowthe outdoor air dew point.These heat exchangers are capable of a 60 to 80% approach ofthe ambient dry-bulb temperature

41、to the secondary airflow enteringwet-bulb temperature. The calculation is called wet-bulb depres-sion efficiency (WBDE) and defined asWBDE = 100 (2)whereWBDE = wet-bulb depression efficiency, %t1= dry-bulb temperature of entering primary air, Ft2= dry-bulb temperature of leaving primary air, Fts = w

42、et-bulb temperature of entering secondary air, FSupply-air-side static pressure losses for these heat exchangersrange from 0.25 to 0.75 in. of water. Wet-side airflow pressure droppenalties range from 0.4 to 0.9 in. of water. Secondary airflow ratiosare in the range of 1.5 to 1 down to a low of 1 cf

43、m of outdoor air(OA) to 0.7 cfm of secondary airflow. The higher the ratios ofwet-side air to dry air, the greater the WBDE, with all other factorsremaining constant. Cooling energy efficiency ratios (EER) for thistype of heat exchanger range from 40 to 80.With DX Refrigeration. Figure 4 illustrates

44、 a package unitdesign that combines the tube-type indirect evaporative cooling heatexchanger with a direct-expansion (DX) refrigeration final stage ofcooling. The geometry of the tube-type heat exchanger usually lim-its the size of this application to less than 40,000 cfm of supply air.By placing th

45、e condenser coil in the wet-side air path off the heatexchanger, the mechanical cooling components coefficient of per-formance (COP) significantly increases over that of an air-cooledcondenser system with the coil in the ambient air. When buildingreturn air is used as the secondary airflow, compress

46、or energy inputsare often reduced from 1.1 kW per ton to 0.70 kW per ton or lower,because building return air from an air-conditioned building has wet-bulb conditions in the range of 60 to 65F at a 75F room dry-bulbtemperature. Wet-side air leaving the heat exchanger is usually in therange of 70 to

47、75F db, but at 80 to 90% rh, depending on the heatexchangers wetting efficiency. Because refrigeration air-cooledcondenser coils are unaffected by humidity, this cooler airstreammay be used to reduce the refrigeration condensing temperature ofthe DX system, which increases compressor capacity and li

48、fe byreducing vapor compression temperature lift.Fig. 3 Indirect Evaporative Cooling (IEC) Heat Exchanger(Courtesy Munters/Des Champs)t1t2t1ts-Fig. 4 Indirect Evaporative Cooler Used as Precooler41.4 2012 ASHRAE HandbookHVAC Systems and EquipmentFigure 5 shows how a heat-pipe, indirect evaporative c

49、oolingheat exchanger may be packaged with a DX-type refrigeration sys-tem, using building return air, to minimize cooling energy consump-tion for an all-outdoor-air design such as may be required for alaboratory or hospital application. The geometry of the heat pipelends itself to the treatment of larger airflow quantities. The dimen-sions shown in Figure 5 are for a nominal 50,000 cfm supply air sys-tem with 220 tons of total load.In addition, the heat pipe heat exchanger has the distinct advan-tage over other air-to-air heat

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1