1、IHS PRODUCT DESIGN IHS ASME E Valued Customer, The Errata to ASME Standards are created by ASME to provide corrections to incorrectly published items, or to correct typographical or grammatical errors in ASME Standards. This Erratum applies to the ASME Standard you have purchased. Thank you! Contact
2、 Us: Americas +1 877 413 5184 Toll Free +1 303 397 7956 Direct Europe, Middle East, Africa +44 1344 328040 Phone +44 1344 328005 Fax Asia Pacific +852 2368 5733 Phone +852 2368 5269 Fax This Page is not part of the original publication ASME/V&V 20 Errata Errata to ASME Standards provide correctio
3、ns to incorrectly published items, or to correct typographical or grammatical errors. Such errata shall be used on the date posted. Information contained in the above is the property of the Copyright holder and all Notice of Disclaimer & Limitation of Liability of the Copyright holder apply. If you
4、have any questions, or need technical assistance please contact IHS Support Record# Codes Affected Subject Posted Date 15-1543 V&V 20 Errata V&V-20-2009 Page 5 - Proposal 09/25/15 Errata 15-1543 - V&V-20-2009 Page 5 Explanation: Add the phrase and has no shared error sources and delete the word gene
5、rally in the V&V-20-2009 standard on page 5, line 8 & 10. Current Text: As will be discussed in detail in Section 5, when the validation variable is directly measured as is To in the Case 1 (para. 1-4.1) example the assumption of effectively independent errors is generally reasonable. Corrected Text
6、: As will be discussed in detail in Section 5, when the validation variable is directly measured and has no shared error sources as is To in the Case 1 (para. 1-4.1) example the assumption of effectively independent errors is generally reasonable. This Page is not part of the original publication AS
7、ME/V&V 20 Errata Errata to ASME Standards provide corrections to incorrectly published items, or to correct typographical or grammatical errors. Such errata shall be used on the date posted. Information contained in the above is the property of the Copyright holder and all Notice of Disclaimer & Lim
8、itation of Liability of the Copyright holder apply. If you have any questions, or need technical assistance please contact IHS Support Record# Codes Affected Subject Posted Date 15-1540 V&V 20 Errata V&V-20-2009 Page 3 09/25/15 Errata 15-1540 - V&V-20-2009 Page 3 Explanation: Add the phrase and has
9、no shared error sources in the V&V-20-2009 standard in the description of Case 1, on page 3, line 2. Current Text: The validation variable, To, is directly measured. Corrected Text: The validation variable, To, is directly measured and has no shared error sources. This Page is not part of the origin
10、al publication ASME/V&V 20 Errata Errata to ASME Standards provide corrections to incorrectly published items, or to correct typographical or grammatical errors. Such errata shall be used on the date posted. Information contained in the above is the property of the Copyright holder and all Notice of
11、 Disclaimer & Limitation of Liability of the Copyright holder apply. If you have any questions, or need technical assistance please contact IHS Support Record# Codes Affected Subject Posted Date 15-85 V&V 20 Fix Equation 7-3-2 in the V&V-20-2009 standard to add a “2“ at the front of the second term
12、on the right. 09/25/15 Errata 15-85 Approved March 4, 2015 Change Equation 7-3-2 in the V&V-20-2009 standard to read as follows: 2 = 2 = 1 +2 = + 1 1 = 1The equation, found on page 50 of the code V&V 20-2009, in the left hand column, in section 7-3.2.1 Experimental Uncertainty, uD, is missing the 2
13、in front of the second term on the right. This Page is not part of the original publication ASME/V&V 20 Errata Errata to ASME Standards provide corrections to incorrectly published items, or to correct typographical or grammatical errors. Such errata shall be used on the date posted. Information con
14、tained in the above is the property of the Copyright holder and all Notice of Disclaimer & Limitation of Liability of the Copyright holder apply. If you have any questions, or need technical assistance please contact IHS Support Record# Codes Affected Subject Posted Date 15-80 V&V 20 Errata - ASME p
15、ublishing error in equation 1-5-4 i in V&V20-2009 standard. 09/25/15 Errata 15-80 Approved March 4, 2015 Change Equation 1-5-4 in the V&V-20-2009 standard to read as follows: E=S D=( + ) ( + )= The equation, found on page 3 of the code V&V 20-2009, in the right hand column, in section 1-5 VALIDATION APPROACH, was mistakenly published with an equals sign (=) between the two terms in parentheses instead of a minus sign ( ).