ASTM A1064 A1064M-2015a Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement Plain and Deformed for Concrete《混凝土的平整和变形的碳质钢丝绳和焊接线缆加固的标准规格》.pdf

上传人:周芸 文档编号:457427 上传时间:2018-11-25 格式:PDF 页数:12 大小:174.19KB
下载 相关 举报
ASTM A1064 A1064M-2015a Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement Plain and Deformed for Concrete《混凝土的平整和变形的碳质钢丝绳和焊接线缆加固的标准规格》.pdf_第1页
第1页 / 共12页
ASTM A1064 A1064M-2015a Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement Plain and Deformed for Concrete《混凝土的平整和变形的碳质钢丝绳和焊接线缆加固的标准规格》.pdf_第2页
第2页 / 共12页
ASTM A1064 A1064M-2015a Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement Plain and Deformed for Concrete《混凝土的平整和变形的碳质钢丝绳和焊接线缆加固的标准规格》.pdf_第3页
第3页 / 共12页
ASTM A1064 A1064M-2015a Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement Plain and Deformed for Concrete《混凝土的平整和变形的碳质钢丝绳和焊接线缆加固的标准规格》.pdf_第4页
第4页 / 共12页
ASTM A1064 A1064M-2015a Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement Plain and Deformed for Concrete《混凝土的平整和变形的碳质钢丝绳和焊接线缆加固的标准规格》.pdf_第5页
第5页 / 共12页
亲,该文档总共12页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: A1064/A1064M 15A1064/A1064M 15aStandard Specification forCarbon-Steel Wire and Welded Wire Reinforcement, Plainand Deformed, for Concrete1This standard is issued under the fixed designation A1064/A1064M; the number immediately following the designation indicates theyear of original adop

2、tion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers carbon-steel wire and welded wire reinforceme

3、nt produced from hot-rolled rod to be used for thereinforcement of concrete. The steel wire is cold-worked, drawn or rolled, plain (non-deformed, as-drawn or galvanized), ordeformed. Welded wire reinforcement is made from plain or deformed wire, or a combination of plain and deformed wire.Common wir

4、e sizes and dimensions are given in Table 1, Table 2, Table 3, and Table 4.Actual wire sizes are not restricted to thoseshown in the tables.NOTE 1Welded wire for concrete reinforcement has historically been described by various terms: welded wire fabric, WWF, fabric, and mesh. Thewire reinforcement

5、industry has adopted the term welded wire reinforcement (WWR) as being more representative of the applications of the productsbeing manufactured. Therefore, the term welded wire fabric has been replaced with the term welded wire reinforcement in this specification and in relatedspecifications.1.2 Th

6、e values stated in either inch-pound or SI units are to be regarded separately as standard. Within the text the SI units areshown in brackets (except in Table 2 and Table 4). The values stated in each system are not exact equivalents; therefore, eachsystem must be used independently of the other. Co

7、mbining values may result in nonconformance with the specification.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the ap

8、plicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A370 Test Methods and Definitions for Mechanical Testing of Steel ProductsA641/A641M Specification for ZincCoated (Galvanized) Carbon Steel WireA700 Guide for Packaging, Marking, and Loading Methods for Stee

9、l Products for ShipmentE83 Practice for Verification and Classification of Extensometer Systems2.2 U.S. Military Standard:3MIL-STD-129 Marking for Shipment and Storage2.3 U.S. Military Standard:3Fed. Std. No. 123 Marking for Shipments (Civil Agencies)2.4 American Concrete Institute (ACI) Standard:4A

10、CI 318 Building Code Requirements for Structural Concrete2.5 Adjuncts:Weld Tester Drawing 53. Terminology3.1 Definitions of Terms Specific to This Standard:1 This specification is under the jurisdiction ofASTM Committee A01 on Steel, Stainless Steel and RelatedAlloys and is the direct responsibility

11、 of Subcommittee A01.05on Steel Reinforcement.Current edition approved March 1, 2015Nov. 1, 2015. Published May 2015January 2016. Originally approved in 2009. Last previous edition approved in 20142015 asA1064/A1064M 14.15. DOI: 10.1520/A1064_A1064M-15.10.1520/A1064_A1064M-15A.2 For referencedASTM s

12、tandards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D,

13、700 Robbins Ave., Philadelphia, PA 19111-5098, http:/www.dodssp.daps.mil.4 Available from American Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI 48333-9094, http:/www.concrete.org.5 Available from ASTM International Headquarters. Order Adjunct No. ADJA0185. Original adjunct produced

14、in 1967.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult p

15、rior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 1

16、9428-2959. United States1TABLE 1 Dimensional Requirements for Plain WireInch-Pound UnitsASizeNumberB,C,D Nominal Diameterin. mmE Nominal Areain.2 mm2W 0.5 0.080 2.03 0.005 3.23W 1.2 0.124 3.14 0.012 7.74W 1.4 0.134 3.39 0.014 9.03W 2 0.160 4.05 0.020 12.9W 2.5 0.178 4.53 0.025 16.1W 2.9 0.192 4.88 0

17、.029 18.7W 3.5 0.211 5.36 0.035 22.6W 4 0.226 5.73 0.040 25.8W 4.5 0.239 6.08 0.045 29.0W 5 0.252 6.41 0.050 32.3W 5.5 0.265 6.72 0.055 35.5W 6 0.276 7.02 0.060 38.7W 8 0.319 8.11 0.080 51.6W 10 0.357 9.06 0.100 64.5W 11 0.374 9.50 0.110 71.0W 12 0.391 9.93 0.120 77.4W 14 0.422 10.7 0.140 90.3W 16 0

18、.451 11.5 0.160 103W 18 0.479 12.2 0.180 116W 20 0.505 12.8 0.200 129W 22 0.529 13.4 0.220 142W 24 0.553 14.0 0.240 155W 26 0.575 14.6 0.260 168W 28 0.597 15.2 0.280 181W 30 0.618 15.7 0.300 194W 31 0.628 16.0 0.310 200W 45 0.757 19.2 0.450 290A Table 1 should be used on projects that are designed u

19、sing inch-pound units; Table 2 should be used on projects that are designed using SI units.B The number following the prefix indicates the nominal cross-sectional area of the wire in square inches multiplied by 100.C For sizes other than those shown above, the Size Number shall be the number of one

20、hundredth of a square inch in the nominal area of the wire cross section, prefixedby the W.D These sizes represent the most readily available sizes in the welded wire reinforcement industry. Other wire sizes are available and many manufactures can producethem in 0.0015 in.2 increments.E The nominal

21、diameter is based on the nominal area of the wire.TABLE 2 Dimensional Requirements for Plain WireSI UnitsASize NumberB, C, D Nominal Diametermm in.E Nominal Areamm2 in.2MW 5 2.52 0.099 5 0.008MW 10 3.57 0.140 10 0.016MW 15 4.37 0.172 15 0.023MW 20 5.05 0.199 20 0.031MW 25 5.64 0.222 25 0.039MW 30 6.

22、18 0.243 30 0.047MW 35 6.68 0.263 35 0.054MW 40 7.14 0.281 40 0.062MW 45 7.57 0.298 45 0.070MW 50 7.98 0.314 50 0.078MW 55 8.37 0.329 55 0.085MW 60 8.74 0.344 60 0.093MW 65 9.10 0.358 65 0.101MW 70 9.44 0.372 70 0.109MW 80 10.1 0.397 80 0.124MW 90 10.7 0.421 90 0.140MW 100 11.3 0.444 100 0.155MW 120

23、 12.4 0.487 120 0.186MW 130 12.9 0.507 130 0.202MW 200 16.0 0.628 200 0.310MW 290 19.2 0.757 290 0.450A The wire sizes in Table 1 should be used on projects that are designed using inch-pound units; the wire sizes in Table 2 should be used on projects that are designedusing SI units.B The number fol

24、lowing the prefix indicates the nominal cross-sectional area of the wire in square milimetres.C For sizes other than those shown above, the Size Number shall be the number of square millimetres in the nominal area of the wire cross section, prefixed by the MW.D These sizes represent the most readily

25、 available sizes in the welded wire reinforcement industry. Other wire sizes are available and many manufactures can producethem in 1 mm2 increments.E The nominal diameter is based on the nominal area of the wire.A1064/A1064M 15a23.1.1 convoluted wirewhen wire for welded wire reinforcement is formed

26、 into a sinusoidal wave shape, it is commonlyreferred to as convoluted wire. The wire is used in the manufacture of cages for certain applications of concrete pipe reinforcement.Deformed wire is not subject to convolution unless agreed upon by the purchaser and manufacturer.3.1.2 deformed wire and w

27、elded deformed wire reinforcementas used within the scope and intent of this specification,designates a material composed of cold-worked deformed steel wire as cold-drawn or cold-rolled from hot-rolled steel rod.Deformations can be indented or raised rib (protrusion) types.The deformations and the w

28、elded intersections provide bond strengthfor shear resistance.3.1.3 plain wire and welded plain wire reinforcementas used within the scope and intent of this specification, designates amaterial composed of cold-worked steel wire, as cold-drawn or cold-rolled from hot-rolled steel rod. The welded int

29、ersectionsprovide the bond strength for shear resistance.4. Ordering Information4.1 It is the responsibility of the purchaser to specify all requirements that are necessary for the manufacture and delivery ofthe wire andOrders for wire or welded wire reinforcement under this specification. Such requ

30、irements to be considered include,but are not limited to, the following:specification shall contain the following information:4.1.1 Quantity (weight mass) or square area for welded wire reinforcement;reinforcement,TABLE 3 Dimensional Requirements for Deformed WireInch-Pound UnitsNominal Dimensions D

31、eformation RequirementsDeformed Wire SizeA, B, C, D Unit Weight, lb/ft Diameter, in.E Cross-Sectional Area, in.2 F Minimum Average Height ofDeformations, in.G, H, ID 1 0.034 0.113 0.010 0.0045D 2 0.068 0.160 0.020 0.0063D 3 0.102 0.195 0.030 0.0078D 4 0.136 0.226 0.040 0.0101D 5 0.170 0.252 0.050 0.

32、0113D 6 0.204 0.276 0.060 0.0124D 7 0.238 0.299 0.070 0.0134D 8 0.272 0.319 0.080 0.0143D 9 0.306 0.339 0.090 0.0152D 10 0.340 0.357 0.100 0.0160D 11 0.374 0.374 0.110 0.0187D 12 0.408 0.391 0.120 0.0195D 13 0.442 0.407 0.130 0.0203D 14 0.476 0.422 0.140 0.0211D 15 0.510 0.437 0.150 0.0218D 16 0.544

33、 0.451 0.160 0.0225D 17 0.578 0.465 0.170 0.0232D 18 0.612 0.479 0.180 0.0239D 19 0.646 0.492 0.190 0.0245D 20 0.680 0.505 0.200 0.0252D 21 0.714 0.517 0.210 0.0259D 22 0.748 0.529 0.220 0.0265D 23 0.782 0.541 0.230 0.0271D 24 0.816 0.553 0.240 0.0277D 25 0.850 0.564 0.250 0.0282D 26 0.884 0.575 0.2

34、60 0.0288D 27 0.918 0.586 0.270 0.0293D 28 0.952 0.597 0.280 0.0299D 29 0.986 0.608 0.290 0.0304D 30 1.02 0.618 0.300 0.0309D 31 1.05 0.628 0.310 0.0314D 45 1.53 0.757 0.450 0.0379A The wire sizes in Table 3 should be used on projects that are designed using inch-pound units; the wire sizes in Table

35、 4 should be used on projects that are designedusing SI units.B The number following the prefix indicates the nominal cross-sectional area of the deformed wire in square inches multiplied by 100.C For sizes other than those shown above, the Size Number shall be the number of one hundredths of a squa

36、re inch in the nominal area of the deformed wire cross section,prefixed by the D.D These sizes represent the most readily available sizes in the welded wire reinforcement industry. Other wire sizes are available and many manufacturers can producethem in 0.0015 in.2 increments.E The nominal diameter

37、of a deformed wire is equivalent to the nominal diameter of a plain wire having the same weight per foot as the deformed wire.F The cross-sectional area is based on the weight of the wire. The area in square inches may be calculated by dividing the weight in pounds by 0.2833 (weight of 1 in.3of stee

38、l) or by dividing the weight per lineal foot of specimen in pounds by 3.4 (weight of steel 1 in. square and 1 foot long).G The minimum average height of the deformations shall be determined from measurements made on not less than two typical deformations from each line of deformationson the wire. Me

39、asurements shall be made at the center of indentation or between two raised ribs as described in 7.2.4.7.H Spacing of deformations shall not be greater than 0.285 in. nor less than 0.182 in. for all wire sizes.I See 7.2.4.3 for average number of deformations per unit length.A1064/A1064M 15a34.1.2 Na

40、me of material (cold-drawn or rolled steel wire, or welded wire reinforcement, plain or deformed, for concrete);concrete),4.1.3 Wire size number (see Section number, 7), wire spacing, and sheet or roll width and length for welded wirereinforcement;reinforcement,4.1.4 Minimum yield strength or Grade;

41、Grade,4.1.5 Yield strength measurement. The purchaser shall specify the method for measuring yield strength (see 7.1.4.2, 7.2.5.2, or8.1.2) and has the options described in 12.3;4.1.6 Request for outside inspection (if not requested, 14.1 applies);4.1.7 Exclusion of over-steeling, if required (see 1

42、0.4.2 and 10.5.1);4.1.5 Packaging (see Section 15);), and4.1.6 ASTM designation and year of issue; andissue.4.1.10 Special requirements, if any.4.2 The purchaser shall have the option to specify additional requirements, including but not limited to, the following:4.2.1 Exclusion of over-steeling (se

43、e 10.4.2 and 10.5.1),4.2.2 Report on tests performed on the steel wire or welded wire reinforcement being furnished (see 14.1), and4.2.3 Special requirements (if desired).5. Materials5.1 The steel shall be made by any commercially accepted process.5.2 Unless otherwise specified, the wire shall be su

44、pplied uncoated. When plain wire is specified as galvanized, it shall begalvanized at finish size as described in Specification A641/A641M.5.3 Wire used in the manufacture of welded wire reinforcement shall conform to this specification either solely or incombination of plain or deformed wire, or bo

45、th.6. Manufacture6.1 The wire shall be cold-worked, drawn or rolled, from rods that have been hot-rolled from billets.TABLE 4 Dimensional Requirements for Deformed WireSI UnitsNominal Dimensions Deformation RequirementsDeformed Wire SizeA, B, C, D D in.2 100 Unit Mass, kg/m Diameter, mmE Cross-Secti

46、onal Area,mm2 F Minimum Average Height ofDeformations, mmG, H, IMD 25 D 3.9 0.196 5.64 25 0.252MD 30 D 4.7 0.235 6.18 30 0.279MD 35 D 5.4 0.275 6.68 35 0.302MD 40 D 6.2 0.314 7.14 40 0.320MD 45 D 7.0 0.353 7.57 45 0.342MD 50 D 7.8 0.392 7.98 50 0.360MD 55 D 8.5 0.432 8.37 55 0.378MD 60 D 9.3 0.471 8

47、.74 60 0.392MD 65 D 10.1 0.510 9.10 65 0.455MD 70 D 10.9 0.549 9.44 70 0.470MD 80 D 12.4 0.628 10.1 80 0.505MD 90 D 14.0 0.706 10.7 90 0.535MD 100 D 15.5 0.785 11.3 100 0.565MD 120 D 18.6 0.942 12.4 120 0.620MD 130 D 20.2 1.02 12.9 130 0.645MD 200 D 31.0 1.57 16.0 200 0.800MD 290 D 45.0 2.28 19.2 29

48、0 0.961A The wire sizes in Table 3 should be used on projects that are designed using inch-pound units; the wire sizes in Table 4 should be used on projects that are designedusing SI units.B The number following the prefix indicates the nominal cross-sectional area of the deformed wire in square mil

49、limetres.C For sizes other than those shown above, the Size Number shall be the number of square millimetres in the nominal area of the deformed wire cross section, prefixedby the MD.D These sizes represent the most readily available sizes in the welded wire reinforcement industry. Other wire sizes are available and many manufacture

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1