1、Designation: A 709/A 709M 09Standard Specification forStructural Steel for Bridges1This standard is issued under the fixed designationA 709/A 709M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number

2、 in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers carbon and high-strength low-alloy steel structural shapes, plates, and bars and quenched andtempered alloy steel

3、for structural plates intended for use inbridges. Seven grades are available in four yield strength levelsas follows:Grade U.S. SI Yield Strength, ksi MPa36 250 36 25050 345 50 34550S 345S 50 34550W 345W 50 345HPS 50W HPS 345W 50 345HPS 70W HPS 485W 70 485HPS 100W HPS 690W 100 6901.1.1 Grades 36 250

4、, 50 345, 50S 345S, and 50W345W are also included in Specifications A 36/A 36M,A 572/A 572M, A 992/A 992M, and A 588/A 588M, respec-tively. When the supplementary requirements of this specifi-cation are specified, they exceed the requirements of Specifi-cations A 36/A 36M, A 572/A 572M, A 992/A 992M

5、, andA 588/A 588M.1.1.2 Grades 50W 345W, HPS 50W HPS 345W, HPS70W HPS 485W, and HPS 100W HPS 690W have en-hanced atmospheric corrosion resistance (see 13.1.2). Productavailability is shown in Table 1.1.2 Grade HPS 70W HPS 485W or HPS 100W HPS690W shall not be substituted for Grades 36 250, 50 345,50

6、S 345S, 50W 345W, or HPS 50W HPS 345W. Grade50W 345W, or HPS 50W HPS 345W shall not be substi-tuted for Grades 36 250, 50 345 or 50S 345S withoutagreement between the purchaser and the supplier.1.3 When the steel is to be welded, it is presupposed that awelding procedure suitable for the grade of st

7、eel and intendeduse or service will be utilized. See Appendix X3 of Specifica-tion A 6/A 6M for information on weldability.1.4 For structural products to be used as tension componentsrequiring notch toughness testing, standardized requirementsare provided in this standard, and they are based uponAme

8、rican Association of State Highway and TransportationOfficials (AASHTO) requirements for both fracture critical andnon-fracture critical members.1.5 Supplementary requirements are available but shallapply only if specified in the purchase order.1.6 The values stated in either SI units or inch-pound

9、unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.7 For structural products produced from

10、coil and fur-nished without heat treatment or with stress relieving only, theadditional requirements, including additional testing require-ments and the reporting of additional test results, of Specifi-cation A 6/A 6M apply.2. Referenced Documents2.1 ASTM Standards:2A 6/A 6M Specification for Genera

11、l Requirements forRolled Structural Steel Bars, Plates, Shapes, and SheetPilingA 36/A 36M Specification for Carbon Structural SteelA 370 Test Methods and Definitions for Mechanical Testingof Steel ProductsA 572/A 572M Specification for High-Strength Low-AlloyColumbium-Vanadium Structural SteelA 588/

12、A 588M Specification for High-Strength Low-AlloyStructural Steel, up to 50 ksi 345 MPa Minimum YieldPoint, with Atmospheric Corrosion ResistanceA 673/A 673M Specification for Sampling Procedure forImpact Testing of Structural SteelA 992/A 992M Specification for Structural Steel Shapes1This specifica

13、tion is under the jurisdiction of ASTM Committee A01 on Steel,Stainless Steel and Related Alloys and is the direct responsibility of SubcommitteeA01.02 on Structural Steel for Bridges, Buildings, Rolling Stock and Ships.Current edition approved April 1, 2009. Published April 2009. Originallyapproved

14、 in 1974. Last previous edition approved in 2008 as A 709/A 709M 08.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM w

15、ebsite.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.G 101 Guide for Estimating the Atmospheric CorrosionResistance of Low-Alloy Steels3. Terminology3.1 Definitions

16、of Terms Specific to This Standard:3.1.1 fracture critical membera main load-carrying ten-sion member or tension component of a bending memberwhose failure would be expected to cause collapse of astructure or bridge without multiple, redundant load paths.3.1.2 main load-carrying membera steel member

17、 de-signed to carry primary design loads, including dead, live,impact, and other loads.3.1.3 non-fracture critical membera main load-carryingmember whose failure would not be expected to cause collapseof a structure or bridge with multiple, redundant load paths.3.1.4 non-tension componenta steel mem

18、ber that is not intension under any design loading.3.1.5 secondary membera steel member used for aligningand bracing of main load-carrying members, or for attachingutilities, signs, or other items to them, but not to directlysupport primary design loads3.1.6 tension componenta part or element of a f

19、racturecritical or non-fracture critical member that is in tension undervarious design loadings.TABLE 1 Tensile and Hardness RequirementsANOTE 1Where “. . .” appears in this table, there is no requirement.GradePlate Thickness,in. mmStructural Shape Flangeor LegThickness, in. mmYield Pointor YieldStr

20、ength,BksiMPaTensileStrength,ksi MPaMinimum Elongation, %Reduc-tion ofAreaC,Dmin, %Plates and BarsC,EShapesE8in.or 200mm2in.or 50mm8in.or 200mm2in.or 50mm36 250 to 4 100, incl to 3 in. 75 mm, incl 36 250 min 5880 400550 20 23 20 21 .over 3 in. 75 mm 36 250 min 58 400 min . 20 19 .50 345 to 4 100, in

21、cl all 50 345 min 65 450 min 18 21 18 21F.50S 345SGall 5065345450HI65 450Hmin . . 18 21.50W 345W andHPS 50WHPS 345Wto 4 100, incl all 50 345 min 70 485 min 18 21 18 21J.HPS 70WHPS 485 Wto 4 100, inclG70 485 minB85110 585760 . 19K. .HPS 100WHPS 690Wto 212 65, inclG100 690 minB110130 760895 . 18K. .LA

22、See specimen orientation and preparation subsection in the Tension Tests section of Specification A6/A6M.BMeasured at 0.2 % offset or 0.5 % extension under load as described in Section 13 of Test Methods A 370.CElongation and reduction of area not required to be determined for floor plates.DFor plat

23、es wider than 24 in. 600 mm, the reduction of area requirement, where applicable, is reduced by five percentage points.EFor plates wider than 24 in. 600 mm, the elongation requirement is reduced by two percentage points. See elongation requirement adjustments in the Tension Testssection of Specifica

24、tion A6/A6M.FElongation in 2 in. or 50 mm: 19 % for shapes with flange thickness over 3 in. 75 mm.GNot applicable.HThe yield to tensile ratio shall be 0.87 or less for shapes that are tested from the web location; for all other shapes, the requirement is 0.85.IA maximum yield strength of 70 ksi 480

25、MPa is permitted for structural shapes that are required to be tested from the web location.JFor wide flange shapes with flange thickness over 3 in. 75 mm, elongation in 2 in. or 50 mm of 18 % minimum applies.KIf measured on the Fig. 3 (Test Methods A 370)112-in. 40mm wide specimen, the elongation i

26、s determined in a 2-in. or 50-mm gage length that includes the fractureand shows the greatest elongation.L40 % minimum applies if measured on the Fig 3 (Test Methods A 370)112-in. 40-mm wide specimen; 50 % minimum applies if measured on the Fig. 4 (Test MethodsA 370)12-in. 12.5-mm round specimen.TAB

27、LE 2 Grade 36 250 Chemical Requirements (Heat Analysis)NOTE 1Where “. . .” appears in this table there is no requirement. The heat analysis for manganese shall be determined and reported as describedin the Heat Analysis section of Specification A 6/A 6M.ProductThickness,in. (mm)ShapesAAllPlatesBBars

28、BTo3420, inclOver34to 112 20to40,inclOver 112 to212 40to65,inclOver 212 to 465 to 100,inclTo3420,inclOver34 to112 20 to40, inclOver 112 to4 100, inclCarbon, max, % 0.26 0.25 0.25 0.26 0.27 0.26 0.27 0.28Manganese, % . . 0.801.20 0.801.20 0.851.20 . 0.600.90 0.600.90Phosphorus, max, % 0.04 0.04 0.04

29、0.04 0.04 0.04 0.04 0.04Sulfur, max, % 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05Silicon, % 0.40 max 0.40 max 0.40 max 0.150.40 0.150.40 0.40 max 0.40 max 0.40 maxCopper, min, % whencopper steel is specified0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20AManganese content of 0.85 to 1.35 % and silicon content

30、of 0.15 to 0.40 % is required for shapes with flange thickness over 3 in. 75 mm.BFor each reduction of 0.01 % below the specified carbon maximum, an increase of 0.06 % manganese above the specified maximum will be permitted up to a maximumof 1.35 %.A 709/A 709M 0924. Ordering Requirements4.1 In addi

31、tion to the items listed in the ordering informa-tion section of Specification A 6/A 6M, the following itemsshould be considered if applicable:TABLE 3 Grade 50 345 Chemical RequirementsA(Heat Analysis)SiliconCColumbium,Vanadiumand NitrogenMaximum Diameter,Thickness, orDistance BetweenParallel Faces,

32、 in. mmCarbon,max, %Manganese,Bmax, %Phosphorus,max, %Sulfur,max, %Plates to112-in. 40-mmThick,Shapes withflangeor legthicknessto 3 in. 75mminclusive, SheetPiling, Bars,Zees, andRolledTees,max, %DPlates Over112-in. 40-mmThick and Shapeswith flange thicknessover 3 in. 75 mm, %4 100 0.23 1.35 0.04 0.0

33、5 0.40 0.150.40EACopper when specified shall have a minimum content of 0.20 % by heat analysis (0.18 % by product analysis).BManganese, minimum by heat analysis of 0.80 % (0.75 % by product analysis) shall be required for all plates over38 in. 10 mm in thickness; a minimum of 0.50% (0.45 % by produc

34、t analysis) shall be required for plates38 in. 10 mm and less in thickness, and for all other products. The manganese to carbon ratio shall notbe less than 2 to 1. For each reduction of 0.01 percentage point below the specified carbon maximum, an increase of 0.06 percentage point manganese above the

35、specified maximum is permitted, up to a maximum of 1.60 %.CSilicon content in excess of 0.40 % by heat analysis must be negotiated.DBars over 112 in. 40 mm in diameter, thickness, or distance between parallel faces, shall be made by a killed steel practice.EAlloy content shall be in accordance with

36、Type 1, 2, 3, or 5 and the contents of the applicable elements shall be reported on the test report.Type Elements Heat Analysis, %1 ColumbiumA0.0050.05B2 Vanadium 0.010.153 ColumbiumAVanadiumColumbium plus vanadium0.0050.05B0.010.150.020.15C5 TitaniumNitrogenVanadium0.0060.040.0030.0150.06 maxAColum

37、bium shall be restricted to Grade 50 345 plate, bar, zee, and rolled tee thickness of34 in. 20 mm max, and to shapes with flange or leg thickness to 112 in.40 mm inclusive unless killed steel is furnished. Killed steel shall be confirmed by a statement of killed steel on the test report, or by a rep

38、ort of the presence of a sufficientquantity of a strong deoxidizing element, such as silicon at 0.10 % or higher, or aluminum at 0.015 % or higher.BProduct analysis limits = 0.004 to 0.06 %.CProduct analysis limits = 0.01 to 0.16 %.TABLE 4 Grade 50W 345 W Chemical Requirements (HeatAnalysis)NOTE 1Ty

39、pes A, B, and C are equivalent to Specification A 588/A 588M Grades A, B, and C, respectively.ElementComposition, %AType A Type B Type CCarbonB0.19 max 0.20 max 0.15 maxManganeseB0.801.25 0.751.35 0.801.35Phosphorus 0.04 max 0.04 max 0.04 maxSulfur 0.05 max 0.05 max 0.05 maxSilicon 0.300.65 0.150.50

40、 0.150.40Nickel 0.40 max 0.50 max 0.250.50Chromium 0.400.65 0.400.70 0.300.50Copper 0.250.40 0.200.40 0.200.50Vanadium 0.020.10 0.010.10 0.010.10AWeldability data for these types have been qualified by FHWA for use in bridgeconstruction.BFor each reduction of 0.01 percentage point below the specifie

41、d maximum forcarbon, an increase of 0.06 percentage point above the specified maximum formanganese is permitted, up to a maximum of 1.50 %.TABLE 5 Grades HPS 50W HPS 345W and HPS 70WHPS 485 W, and HPS 100W HPS 690W Chemical Requirements(Heat Analysis)NOTE 1Where “. . .” appears in this table, there

42、is no requirement.Element Composition, %GradesHPS 50W HPS 345W,HPS 70W HPS 485WGradeHPS 100W HPS 690WCarbon 0.11 max 0.08 maxManganese2.5 in. 65 mm and under 1.101.35 0.951.50Over 2.5 in. 65 mm 1.101.50APhosphorus 0.020 max 0.015 maxSulfurB0.006 max 0.006 maxSilicon 0.300.50 0.150.35Copper 0.250.40

43、0.901.20Nickel 0.250.40 0.650.90Chromium 0.450.70 0.400.65Molybdenum 0.020.08 0.400.65Vanadium 0.040.08 0.040.08Columbium (Niobium) . . . 0.010.03Aluminum 0.0100.040 0.0200.050Nitrogen 0.015 max 0.015 maxANot applicable.BThe steel shall be calcium treated for sulfide shape control.A 709/A 709M 0934.

44、1.1 Type of component (tension or non-tension, fracturecritical or non-fracture critical) (see Section 10).4.2 Impact testing temperature zone (see Table 7).5. General Requirements for Delivery5.1 Structural products furnished under this specificationshall conform to the requirements of the current

45、edition ofSpecification A 6/A 6M, for the specific structural productordered, unless a conflict exists in which case this specificationshall prevail.5.2 Coils are excluded from qualification to this specifica-tion until they are processed into a finished structural product.Structural products produc

46、ed from coil means structural prod-ucts that have been cut to individual lengths from a coil. Theprocessor directly controls, or is responsible for, the operationsinvolved in the processing of a coil into a finished structuralproduct. Such operations include decoiling, leveling orstraightening, hot-

47、forming or cold-forming (if applicable),cutting to length, testing, inspection, conditioning, heat treat-ment (if applicable), packaging, marking, loading for shipment,and certification.NOTE 1For structural products produced from coil and furnishedwithout heat treatment or with stress relieving only

48、, two test results are tobe reported for each qualifying coil. Additional requirements regardingstructural products produced from coil are described in SpecificationA 6/A 6M.6. Materials and Manufacture6.1 For Grades 36 250 and 50 345, the steel shall besemi-killed or killed.6.2 For Grades 50W 345W, HPS 50W HPS 345W, andHPS 70W HPS 485W, the steel shall be made to fine grainpractice.6.3 For Grade 50S 345S, the steel shall be killed and suchshall be affirmed in the test report by a statement of killed steel,a value of 0.10 % or more for the silicon content, or a