ASTM A763-1993(2004) Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels《铁素体不锈钢晶间腐蚀敏感性检测的标准操作规程》.pdf

上传人:bowdiet140 文档编号:459447 上传时间:2018-11-25 格式:PDF 页数:11 大小:259.42KB
下载 相关 举报
ASTM A763-1993(2004) Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels《铁素体不锈钢晶间腐蚀敏感性检测的标准操作规程》.pdf_第1页
第1页 / 共11页
ASTM A763-1993(2004) Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels《铁素体不锈钢晶间腐蚀敏感性检测的标准操作规程》.pdf_第2页
第2页 / 共11页
ASTM A763-1993(2004) Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels《铁素体不锈钢晶间腐蚀敏感性检测的标准操作规程》.pdf_第3页
第3页 / 共11页
ASTM A763-1993(2004) Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels《铁素体不锈钢晶间腐蚀敏感性检测的标准操作规程》.pdf_第4页
第4页 / 共11页
ASTM A763-1993(2004) Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels《铁素体不锈钢晶间腐蚀敏感性检测的标准操作规程》.pdf_第5页
第5页 / 共11页
亲,该文档总共11页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: A 763 93 (Reapproved 2004)Standard Practices forDetecting Susceptibility to Intergranular Attack in FerriticStainless Steels1This standard is issued under the fixed designation A 763; the number immediately following the designation indicates the year oforiginal adoption or, in the case

2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These practices cover the following four tests:1.1.1 Practice WOxalic acid etch test for de

3、tecting sus-ceptibility to intergranular attack in stabilized ferritic stainlesssteels by classification of the etching structures (see Sections 3through 10).1.1.2 Practice XFerric sulfate-sulfuric acid test for detect-ing susceptibility to intergranular attack in ferritic stainlesssteels (Sections

4、11 to 16).1.1.3 Practice YCopper-copper sulfate-50 % sulfuric acidtest for detecting susceptibility to intergranular attack in ferriticstainless steels (Sections 17 to 22).1.1.4 Practice ZCopper-copper sulfate-16 % sulfuric acidtest for detecting susceptibility to intergranular attack in ferriticsta

5、inless steels (Sections 23 to 29).1.2 The following factors govern the application of thesepractices (16)2:1.2.1 Practice W, oxalic acid test, is a rapid method ofidentifying, by simple, electrolytic etching, those specimens ofcertain ferritic alloys that are not susceptible to intergranularcorrosio

6、n associated with chromium carbide precipitation.Practice W is used as a screening test to avoid the necessity, foracceptable specimens, of more extensive testing required byPractices X, Y, and Z. See Table 1 for a listing of alloys forwhich Practice W is appropriate.1.2.2 Practices X, Y, and Z can

7、be used to detect thesusceptibility of certain ferritic alloys to intergranular attackassociated with the precipitation of chromium carbides ornitrides.1.2.3 Practices W, X, Y, and Z can also be used to evaluatethe effect of heat treatment or of fusion welding on suscepti-bility to intergranular cor

8、rosion.1.2.4 Table 2 lists the identification ferritic stainless steelsfor which data on the application of at least one of the standardpractices is available.1.2.5 Some stabilized ferritic stainless steels may show highrates when tested by Practice X because of metallurgicalfactors not associated w

9、ith chromium carbide or nitride pre-cipitation. This possibility must be considered in selecting thetest method. Combinations of alloys and test methods forwhich successful experience is available are shown in Table 1.Application of these standard tests to the other ferritic stainlesssteels will be

10、by specific agreement between producer and user.1.3 Depending on the test and alloy, evaluations may beaccomplished by weight loss determination, microscopicalexamination, or bend test (Sections 30 and 31). The choices arelisted in Table 1.1.4 This standard does not purport to address all of thesafe

11、ty problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific safetyprecautionary statements, see 3.2.5, Section 7, 13.1, a

12、nd 19.1.2. Referenced Documents2.1 ASTM Standards:3A 370 Test Methods and Definitions for Mechanical Testingof Steel Products3. Apparatus3.1 Apparatus for Practice W, Oxalic Acid Etch Test:3.1.1 Source of DCBattery, generator, or rectifier capableof supplying 15 V and 20 A.3.1.2 Ammeter, range 0 to

13、30 A.3.1.3 Variable Resistance, for control of specimen current.3.1.4 CathodeOne-litre stainless steel beaker or suitablepiece of stainless steel.3.1.5 Electric Clamp, to hold etched specimen.3.1.6 Metallurgical Microscope, for examination of etchedstructures at 250 to 5003.3.1.7 ElectrodesThe speci

14、men is made the anode and thebeaker or other piece of stainless steel the cathode.3.1.8 ElectrolyteOxalic acid (H2C2O42H2O) reagentgrade, 10 weight % solution.1These practices are under the jurisdiction of ASTM Committee A01 on Steel,Stainless Steel and Related Alloys, and are the direct responsibil

15、ity of SubcommitteeA01.14 on Methods of Corrosion Testing.Current edition approved March 1, 2004. Published March 2004. Originallyapproved in 1979. Last previous edition approved in 1999 as A 763 93 (1999)e1.2The boldface numbers in parentheses refer to the list of references appended tothese practi

16、ces.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO

17、Box C700, West Conshohocken, PA 19428-2959, United States.3.2 The apparatus common to Practices X, Y, and Z is listedbelow. Supplementary requirements are noted as required.3.2.1 The apparatus used is shown in Fig. 1.NOTE 1No substitution for this equipment may be used. The cold-finger type of conde

18、nser with standard Erlenmeyer flasks may not be used.3.2.2 Allihn or Soxhlet Condenser, four-bulb (minimum)with a 45/50 ground-glass joint. Overall length shall be about330 mm (13 in.) with condensing section, 241 mm (912 in.).3.2.3 Erlenmeyer Flask, 1-L with a 45/50 ground-glassjoint. The ground-gl

19、ass opening is somewhat over 38 mm (112in.) wide.3.2.4 Glass Cradles (Note 2) can be supplied by a glassblowing shop. The size of the cradles should be such that theycan pass through the ground-glass joint of the Erlenmeyerflask. They should have three or four holes in them to increasecirculation of

20、 the test solution around the specimen.NOTE 2Other equivalent means of specimen support such as glasshooks or stirrups may also be used.3.2.5 Boiling Chips, must be used to prevent bumping. Ithas been reported that violent boiling resulting in acid spillscan occur. It is important to ensure that the

21、 concentration ofacid does not become more concentrated and that an adequatenumber of boiling chips (which are resistant to attack by thetest solution) are present.43.2.6 Silicone Grease, is recommended for the ground-glassjoint.3.2.7 Electrically Heated Hot Plate, or other device toprovide heat for

22、 continuous boiling of the solution.4Amphoteric alundum granules, Hengar Granules, from the Hengar Company,Philadelphia, PA have been found satisfactory for this purpose.TABLE 1 Methods for Evaluating Ferritic Stainless Steels for Susceptibility to Intergranular CorrosionAlloy Time of Test, hEvaluat

23、ion CriteriaWeight Loss MicroscopicalExaminationBend TestPRACTICE WOXALIC ACID ETCH TEST439 0.025 NA AANA18Cr-2Mo 0.025 NA AANAXM27 0.025 NA AANAXM33 0.025 NA AANA26-3-3 0.025 NA AANAPRACTICE XFERRIC SULFATE - SULFURIC ACID TEST430 24 AB,CANA446 72 ACXM27 120 ADACNA29Cr-4Mo 120 NAEACNA29Cr-4Mo-2Ni 1

24、20 NA ACNAPRACTICE YCOPPER-COPPER SULFATE - 50% SULFURIC ACID TEST446 96 ACANAXM27 120 ADACNAXM33 120 ADACNA2633 120 ADACNA29-4C 120 ADACNA29Cr-4Mo 120 NA ACNA29Cr-4Mo-2Ni 120 NA ACNAPRACTICE ZCOPPER-COPPER SULFATE - 16% SULFURIC ACID TEST430 24 NA NA no fissures434 24 NA NA no fissures436 24 NA NA

25、no fissures439 24 NA NA no fissures18Cr-2Mo 24 NA NA no fissuresAPolished surface examined at 250 to 5003 with a metallurgical microscope (see 3.1.6). All other microscopical examinations are of the corroded surface under 403binocular examination (see Section 27).BA = Applicable.CPreferred criterion

26、, these criteria are the most sensitive for the particular combination of alloy and test.DWeight loss measurements can be used to detect severely sensitized material, but they are not very sensitive for alloys noted with this superscript and may not detectslight or moderate sensitization.ENA = Not a

27、pplicable.TABLE 2 Steels for Which Test Results are AvailableUNS Designation Alloy Practice(s)S43000 430AX, ZS43400 434AZS43600 436AZS43035 XM8 ZS44400 18Cr-2Mo W, ZS44600 446AX, YS44626 XM33 W, YS44627 XM27 W, X, YS44660 2633 YS44700 29Cr-4Mo X, YS44735 29-4C YS44800 29Cr-4Mo-2NI X, YATypes 430, 43

28、4, 436, and 446 are nonstabilized grades that are generally notused in the as-welded or sensitized condition in other than mildly corrosiveenvironments. In the annealed condition, they are not subject to intergranularcorrosion. For any studies of IGA on Types 430, 434, 436, or 446, the indicated tes

29、tmethods are suggested.A 763 93 (2004)24. Preparation of Test Specimens4.1 The preparation of test specimens is common amongPractices X, Y, and Z. Additional requirements are noted wherenecessary.4.2 A specimen having a total surface area of 5 to 20 cm2isrecommended for Practices X, Y, and Z. As-wel

30、ded specimensshould be cut so that no more than 13 mm12 (in.) width ofunaffected base metal is included on either side of the weld andheat-affected zone.4.3 The intent is to test a specimen representing as nearly aspossible the surface of the material as used in service. Onlysuch surface finishing s

31、hould be performed as is required toremove foreign material and obtain a standard, uniform finishas specified. For very heavy sections, specimens should beprepared to represent the appropriate surface while maintainingreasonable specimen size for convenience in testing. Ordi-narily, removal of more

32、material than necessary will have littleinfluence on the test results. However, in the special case ofsurface carburization (sometimes encountered, for instance, intubing when carbonaceous lubricants are employed) it may bepossible by heavy grinding or machining to remove thecarburized layer complet

33、ely. Such treatment of test specimensis not permissible, except in tests undertaken to demonstratesuch surface effects.4.4 Sensitization of Test Specimens:4.4.1 Specimens from material that is going to be used in theas-received condition without additional welding or heat treat-ment may be tested in

34、 the as-received condition without anysensitizing treatment.4.4.2 Specimens from material that is going to be welded orheat treated should be welded or heat treated in as nearly thesame manner as the material will experience in service.4.4.3 The specific sensitizing or welding treatment, or both,sho

35、uld be agreed upon between the supplier and the purchaser.4.5 For Practice W, a cross section of the sample includingmaterial at both surfaces and a cross section of any weld and itsheat affected zones should be prepared. If the sample is toothick, multiple specimens should be used. Grind the crosss

36、ection on wet or dry 80 or 120-grit abrasive paper followed bysuccessively finer papers until a number 400 or 3/0 finish isobtained. Avoid excessive heat when dry-grinding.4.6 For Practices X, Y, and Z, all surfaces of the specimenincluding edges should be ground on wet or dry 80 or 120-gritabrasive

37、 paper. Avoid excessive heat when dry-grinding. Donot use sand- or grit-blasting. All traces of oxide scale formedduring heat treatment must be removed. To avoid scaleentrapment, stamp specimens for identification after heattreatment and grinding.4.7 Degrease and dry the sample using suitable nonchl

38、ori-nated agents.PRACTICE WOXALIC ACID ETCH TEST FORDETECTING SUSCEPTIBILITY TOINTERGRANULAR ATTACK BY CLASSIFICATIONOF MICROSTRUCTURE FOR SCREENING OFCERTAIN FERRITIC STAINLESS STEELS5. Scope5.1 The oxalic acid etch test is intended and may be used forscreening of certain ferritic stainless steels

39、to precede orpreclude the need for corrosion testing as described in PracticesX, Y, or Z. Specimens with unacceptable microstructuresshould be subjected to Practices X, Y, or Z to better determinetheir susceptibility to intergranular attack. See Table 1 for alisting of alloys for which Practice W is

40、 appropriate.6. Etching Conditions6.1 The polished specimens should be etched at 1 A/cm2for1.5 min. This may be accomplished with the apparatus pre-scribed in 3.1 by adjusting the variable resistance until theammeter reading in amperes equals the immersed specimenarea in square centimetres. Immersio

41、n of the specimen-holdingclamp in the etching solution should be avoided.7. Etching Precautions7.1 Etching should be carried out under a ventilating hood.Gas evolved at the electrodes with entrained oxalic acid ispoisonous and irritating. The temperature of the etchingsolution, which increases durin

42、g etching, should be kept below50C by using two beakers of acid, one of which may becooled while the other is in use.FIG. 1 Test ApparatusA 763 93 (2004)38. Rinsing Prior to Examination8.1 Following etching, the specimen should be rinsed in hotwater then acetone or alcohol to avoid oxalic acid cryst

43、alliza-tion on the etched surface during forced air-drying.9. Examination9.1 Examine etched specimens on a metallurgical micro-scope at 250 to 5003 as appropriate for classification of etchedmicrostructure type as defined in Section 10.10. Classification of Etched Structures10.1 Acceptable structure

44、s indicating resistance to chro-mium carbide-type intergranular attack:10.1.1 Step structureSteps only between grainsnoditches at grain boundaries (see Fig. 2).10.1.2 Dual structureSome ditches at grain boundaries inaddition to steps, but no single grain completely surrounded byditches (see Fig. 3).

45、FIG. 2 Acceptable Structures Practice WOxalic-Acid Etch Test Steps Between Grains No DitchingA 763 93 (2004)410.2 Unacceptable structures requiring additional testing(Practices X, Y, or Z):10.2.1 Ditch structureOne or more grains completelysurrounded by ditches (see Fig. 4).PRACTICE XFERRIC SULFATE-

46、SULFURIC ACIDTEST FOR DETECTING SUSCEPTIBILITY TOINTERGRANULAR ATTACK IN FERRITICSTAINLESS STEELS11. Scope11.1 This practice describes the procedure for conductingthe boiling ferric sulfate-sulfuric acid test which measures thesusceptibility of ferritic stainless steels to intergranular attack.This

47、test detects susceptibility to intergranular attack associ-ated with the precipitation of chromium carbides and nitrides instabilized and unstabilized ferric stainless steels. It may alsodetect the presence of chi or sigma phase in these steels. Thetest will not differentiate between intergranular a

48、ttack resultingfrom carbides and that due to intermetallic phases. The ferricsulfate-sulfuric acid solution may also selectively attack tita-nium carbides and nitrides in stabilized steels. The alloys onwhich the test has been successfully applied are shown in Table1.11.2 This test may be used to ev

49、aluate the susceptibility ofas-received material to intergranular corrosion caused bychromium carbide or nitride precipitation. It may be applied towrought products and weld metal.11.3 This procedure may be used on ferritic stainless steelsafter an appropriate sensitizing heat treatment or weldingprocedure as agreed upon between the supplier and thepurchaser.12. Apparatus12.1 The basic apparatus is described in Section 3. Alsoneeded are:12.1.1 For weight loss determination, an analytical balancecapable of weighing to at least the nearest 0.001 g.12.