ASTM B172-2010(2015) Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members for Electrical Conductors《电导线用成束绞绳铜导线的标准规格》.pdf

上传人:amazingpat195 文档编号:460524 上传时间:2018-11-25 格式:PDF 页数:7 大小:99.21KB
下载 相关 举报
ASTM B172-2010(2015) Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members for Electrical Conductors《电导线用成束绞绳铜导线的标准规格》.pdf_第1页
第1页 / 共7页
ASTM B172-2010(2015) Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members for Electrical Conductors《电导线用成束绞绳铜导线的标准规格》.pdf_第2页
第2页 / 共7页
ASTM B172-2010(2015) Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members for Electrical Conductors《电导线用成束绞绳铜导线的标准规格》.pdf_第3页
第3页 / 共7页
ASTM B172-2010(2015) Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members for Electrical Conductors《电导线用成束绞绳铜导线的标准规格》.pdf_第4页
第4页 / 共7页
ASTM B172-2010(2015) Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members for Electrical Conductors《电导线用成束绞绳铜导线的标准规格》.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: B172 10 (Reapproved 2015)Standard Specification forRope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors1This standard is issued under the fixed designation B172; the number immediately following the designation indicates the year oforiginal adopti

2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.

3、1. Scope1.1 This specification covers bare rope-lay-stranded con-ductors having bunch-stranded members made from roundcopper wires, either uncoated or coated with tin, lead, orlead-alloy for use as electrical conductors (Explanatory Notes1 and 2).1.2 Coated wires shall include only those wires with

4、fin-ished diameters and densities substantially equal to the respec-tive diameters and densities of uncoated wires.1.3 The values stated in inch-pound or SI units are to beregarded separately as standard. Each system shall be usedindependently of the other. Combining values from the twosystems may r

5、esult in nonconformance with the specification.For conductor sizes designated by AWG or kcmil, the require-ments in SI units have been numerically converted fromcorresponding values, stated or derived, in inch-pound units.For conductor sizes designated by SI units only, the require-ments are stated

6、or derived in SI units.1.3.1 For density, resistivity, and temperature, the valuesstated in SI units are to be regarded as standard.2. Referenced Documents2.1 The following documents of the issue in effect at thetime of reference form a part of this specification to the extentreferenced herein:2.2 A

7、STM Standards:2B3 Specification for Soft or Annealed Copper WireB33 Specification for Tin-Coated Soft or Annealed CopperWire for Electrical PurposesB173 Specification for Rope-Lay-Stranded Copper Conduc-tors Having Concentric-Stranded Members, for ElectricalConductorsB189 Specification for Lead-Coat

8、ed and Lead-Alloy-CoatedSoft Copper Wire for Electrical PurposesB193 Test Method for Resistivity of Electrical ConductorMaterialsB263 Test Method for Determination of Cross-SectionalArea of Stranded ConductorsB354 Terminology Relating to Uninsulated Metallic Electri-cal Conductors2.3 American Nation

9、al Standard:ANSI C42.35 Definitions of Electrical Terms33. Classification3.1 For the purpose of this specification rope-lay-strandedconductors having bunch-stranded members are classifed asfollows:3.1.1 Class IConductors consisting of wires 0.0201-in.(0.511-mm) diameter (No. 24 AWG) to produce rope-

10、lay-stranded conductors up to 2 000 000 cmil (1013 mm2) in totalcross-sectional area. (Typical use is for special apparatusconductor.)3.1.2 Class KConductors consisting of wires 0.0100-in.(0.254-mm) diameter (No. 30 AWG) to produce rope-lay-stranded conductors up to 1 000 000 cmil (507 mm2) in total

11、cross-sectional area. (Typical use is for special portable cordand conductors.)3.1.3 Class MConductors consisting of wires 0.0063-in.(0.160-mm) diameter (No. 34 AWG) to produce rope-lay-stranded conductors up to 1 000 000 cmil (507 mm2) in totalcross-sectional area. (Typical use is for welding condu

12、ctors.)4. Ordering Information4.1 Orders for material under this specification shall includethe following information:4.1.1 Quantity of each size and class,4.1.2 Conductor size: circular-mil area or AWG (see 7.1),4.1.3 Class (Section 4 and Tables 1-3),1This specification is under the jurisdiction of

13、 ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.04 onConductors of Copper and Copper Alloys.Current edition approved April 1, 2015. Published April 2015. Originallyapproved in 1942 to replace portions of B158 41 T. Last previous edition approvedin 201

14、0 as B172 10. DOI: 10.1520/B0172-10R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Americ

15、an National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.1.4 Whether coated or uncoated; if coated, designate typeof coating (see 11.1),

16、4.1.5 Details of special-purpose lays, if required (see 6.2,6.3, and Explanatory Note 3),4.1.6 Package size (see 15.1),4.1.7 Special package marking, if required (Section 14),4.1.8 Lagging, if required (see 15.2), and4.1.9 Place of inspection (Section 13).5. Joints5.1 Necessary joints in wires or in

17、 groups of wires shall bemade in accordance with accepted commercial practice, takinginto account the size of the wire or group of wires as related tothe size of the entire conductor.5.2 Bunch-stranded members or rope-stranded membersforming the completed conductor may be joined as a unit bysolderin

18、g, brazing, or welding.TABLE 1 Construction Requirements of Class I Rope-Lay Stranded Copper Conductors Having Bunch Stranded MembersAUncoated Copper Coated CopperArea of Cross SectionSizeAWGWireDiameter0.0201in.(0.511mm)ApproximateMassBNominaldc resistance 20CMaximumdc resistance 20CNominaldc resis

19、tance 20CMaximumdc resistance 20Ccmil mm2NominalNumberof WiresStrandConstructionAbyBbyCClb/1000 ft.kg/kmOhm / kft Ohm / km Ohm /kftOhm /kmOhm / kft Ohm / km Ohm /kftOhm /km2 000 000 1013 . . . 4921 19 by 7 by 37 6439 9583 0.00555 0.0182 0.00566 0.0186 0.00577 0.0189 0.00589 0.01931 900 000 963 . . .

20、 4788 19 by 7 by 36 6265 9324 0.00584 0.0192 0.00596 0.0196 0.00607 0.0199 0.00619 0.02031 800 000 912 . . . 4522 19 by 7 by 34 5917 8806 0.00616 0.0202 0.00628 0.0206 0.00641 0.0210 0.00654 0.02141 750 000 887 . . . 4389 19 by 7 by 33 5743 8547 0.00634 0.0208 0.00647 0.0212 0.00659 0.0216 0.00672 0

21、.02201 700 000 861 . . . 4256 19 by 7 by 32 5569 8288 0.00653 0.0214 0.00666 0.0218 0.00679 0.0223 0.00693 0.02271 600 000 811 . . . 3990 19 by 7 by 30 5221 7770 0.00694 0.0228 0.00708 0.0233 0.00721 0.0237 0.00735 0.02421 500 000 760 . . . 3724 19 by 7 by 28 4873 7252 0.00740 0.0243 0.00755 0.0248

22、0.00769 0.0252 0.00784 0.02571 400 000 709 . . . 3458 19 by 7 by 26 4525 6734 0.00793 0.0260 0.00809 0.0265 0.00824 0.0270 0.00840 0.02751 300 000 659 . . . 3192 19 by 7 by 24 4177 6216 0.00854 0.0280 0.00871 0.0286 0.00888 0.0291 0.00906 0.02971 250 000 633 . . . 3059 19 by 7 by 23 4003 5957 0.0088

23、8 0.0291 0.00906 0.0297 0.00923 0.0303 0.00941 0.03091 200 000 608 . . . 2926 19 by 7 by 22 3829 5698 0.00925 0.0303 0.00944 0.0309 0.00962 0.0316 0.00981 0.03221 100 000 557 . . . 2793 19 by 7 by 21 3655 5439 0.0101 0.0331 0.0103 0.0338 0.0105 0.0344 0.0107 0.03511 000 000 507 . . . 2527 19 by 7 by

24、 19 3307 4921 0.0111 0.0364 0.0113 0.0371 0.0115 0.0379 0.0117 0.0387900 000 456 . . . 2261 19 by 7 by 17 2959 4403 0.0123 0.0405 0.0125 0.0413 0.0128 0.0421 0.0131 0.0429800 000 405 . . . 1995 19 by 7 by 15 2611 3885 0.0139 0.0455 0.0142 0.0464 0.0144 0.0473 0.0147 0.0482750 000 380 . . . 1862 19 b

25、y 7 by 14 2436 3626 0.0148 0.0485 0.0151 0.0495 0.0154 0.0505 0.0157 0.0515700 000 355 . . . 1729 19 by 7 by 13 2262 3367 0.0159 0.0520 0.0162 0.0530 0.0165 0.0541 0.0168 0.0552650 000 329 . . . 1596 19 by 7 by 12 2088 3108 0.0171 0.0560 0.0174 0.0571 0.0178 0.0583 0.0182 0.0594600 000 304 . . . 147

26、0 7 by 7 by 30 1906 2836 0.0183 0.0601 0.0187 0.0613 0.0191 0.0625 0.0195 0.0638550 000 279 . . . 1372 7 by 7 by 28 1779 2647 0.0200 0.0656 0.0204 0.0669 0.0208 0.0682 0.0212 0.0696500 000 253 . . . 1225 7 by 7 by 25 1588 2363 0.0220 0.0721 0.0224 0.0735 0.0229 0.0750 0.0234 0.0765450 000 228 . . .

27、1127 7 by 7 by 23 1461 2174 0.0244 0.0802 0.0249 0.0817 0.0254 0.0834 0.0259 0.0850400 000 203 . . . 980 7 by 7 by 20 1270 1891 0.0275 0.0902 0.0281 0.0920 0.0286 0.0938 0.0292 0.0957350 000 177 . . . 882 7 by 7 by 18 1143 1701 0.0314 0.103 0.0320 0.105 0.0327 0.107 0.0334 0.109300 000 152 . . . 735

28、 7 by 7 by 15 953 1418 0.0366 0.120 0.0373 0.122 0.0381 0.125 0.0389 0.128250 000 127 . . . 637 7 by 7 by 13 826 1229 0.0440 0.144 0.0449 0.147 0.0457 0.150 0.0466 0.153211 600 107 0000 532 19 by 28 683 1017 0.0515 0.169 0.0525 0.172 0.0536 0.176 0.0546 0.180167 800 85 000 418 19 by 22 537 799 0.064

29、9 0.213 0.0662 0.217 0.0675 0.221 0.0689 0.225133 100 67.4 00 342 19 by 18 439 654 0.0818 0.268 0.0834 0.273 0.0851 0.279 0.0868 0.285105 600 53.5 0 266 19 by 14 342 508 0.103 0.338 0.105 0.345 0.107 0.352 0.109 0.35983 690 42.4 1 210 7 by 30 267 397 0.129 0.423 0.132 0.431 0.134 0.440 0.137 0.44966

30、 360 33.6 2 161 7 by 23 205 305 0.163 0.533 0.166 0.544 0.169 0.555 0.172 0.56652 620 26.7 3 133 7 by 19 169 252 0.205 0.673 0.209 0.686 0.213 0.699 0.217 0.71341 740 21.1 4 105 7 by 15 134 199 0.258 0.848 0.263 0.865 0.269 0.882 0.274 0.90033 090 16.8 5 84 7 by 12 107 159 0.326 1.07 0.333 1.09 0.33

31、9 1.11 0.346 1.1326 240 13.3 6 63 7 by 9 80 119 0.411 1.35 0.419 1.38 0.427 1.40 0.436 1.43AThe constructions shown in this table are typical of those used in the industry. It is not intended that this table preclude other constructions which may be desireable forspecific applications. The construct

32、ions shown provide for finished, covered or non-covered, stranded conductor approximately of the area indicated. When specified bythe purchaser, the number of strands may be increased to provide additional area to compensate for draw-down during subsequent processing.BValues for the mass of the comp

33、leted conductor are approximate. The mass values are based upon the standard stranding increments listed in Explanatory Note 6.CStrand Construction#A by #B by #C: where #C is the number of wires in each bunch-stranded member; #B is the number of bunch stranded members which make-upeach rope-stranded

34、 member; and #A (where used) is the number of rope-stranded members in the conductor. Where #A is not given, the conductor consists of onerope-stranded member. For example, 19 by 7 by 32 indicates a construction consisting of 19 rope-stranded members, each of which consists of 7 bunch-strandedmember

35、s with 32 wires each.B172 10 (2015)2TABLE2ConstructionRequirementsofClassKRope-LayStrandedCopperConductorsHavingBunchStrandedMembersAAreaofCrossSectionWireDiameter 0.0100In.(0.254mm)ApproximateMassBUncoatedCopperCoatedCoppercmilmm2SizeAWGNominal Number ofWiresStrand Construction AbyBbyCCLb/1000ftKg/

36、kmNominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20C1,000,0005071010137by7by39327248690.01110.03640.01130.03710.01190.03910.01210.0399900,000456906537by7by35293643690.01230.04050.01250.04130.01320.04340.01350.0443800,000405798019by7by60258538460.01390.04550.0142

37、0.04640.01490.04890.01520.0499750,000380758119by7by57245536540.01480.04850.01510.04950.01590.05210.01620.0531700,000355691619by7by52224033330.01590.05200.01620.05300.01700.05580.01730.0569650,000329651719by7by49211131410.01710.05600.01740.05710.01830.06010.01870.0613600,000304598519by7by45193828850.

38、01850.06070.01890.06190.01990.06510.02030.0664550,000279545319by7by41176626280.02020.06620.02060.06750.02170.07110.02210.0725500,000253505419by7by38163724360.02220.07280.02260.07430.02380.07820.02430.0798450,000228452219by7by34146521800.02470.08090.02520.08250.02650.08690.02700.0886400,000203399019b

39、y7by30129219230.02770.09100.02830.09280.02980.09770.03040.0997350,000177345819by7by26112016670.03170.1040.03230.1060.03400.1120.03470.114300,00015229897by7by6195914270.03660.1200.03730.1220.03930.1290.04010.132250,00012724997by7by5180211930.04400.1440.04490.1470.04720.1550.04810.158211,6001070000210

40、77by7by4367610060.05200.1710.05300.1740.05580.1830.05690.187167,8008500016667by7by345357950.06550.2150.06680.2190.07030.2310.07170.236133,10067.40013237by7by274246320.08260.2710.08430.2760.08870.2910.09050.297105,60053.50106419by563385030.1030.3380.1050.3450.1110.3630.1130.37083,69042.4183619by44266

41、3950.1300.4270.1330.4350.1400.4580.1420.46766,36033.6266519by352113150.1640.5380.1670.5490.1760.5780.1800.59052,62026.7353219by281692520.2070.6790.2110.6930.2220.7290.2270.74441,74021.144207by601321970.2580.8480.2640.8650.2770.9100.2830.92833,09016.853367by481061570.3261.070.3331.090.3501.150.3571.1

42、726,24013.362667by38841250.4111.350.4191.380.4411.450.4501.4820,82010.572107by3066980.5181.700.5281.730.5561.820.5671.8616,5108.3781687by2453790.6532.140.6662.190.7012.300.7152.3513,0906.6391337by1942620.8242.700.8402.760.8852.900.9022.96ATheconstructionsshowninthistablearetypicalofthoseusedintheind

43、ustry.Itisnotintendedthatthistableprecludeotherconstructionswhichmaybedesirableforspecificapplications.Theconstructionsshownprovideforfinishedcoveredornon-coveredstrandedconductorapproximatelyoftheareaindicated.Whenspecifiedbythepurchaser,thenumberofstrandsmaybeincreasedtoprovideadditionalareatocomp

44、ensatefordraw-downduringsubsequentprocessing.BValuesforthemassofthecompletedconductorareapproximate.ThemassvaluesarebaseduponthestandardstrandingincrementslistedinExplanatoryNote6.CStrandconstructionAbyBbyCwhereCisthenumberofwiresineachbunch-strandedmember,Bisthenumberofbunch-strandedmemberswhichmak

45、eupeachropestrandedmember,andA(whereused)isthenumberofrope-strandedmembersintheconductor.WhereAisnotgiven,theconductorconsistsofonerope-strandedmember.Forexample,19by7by32indicatesaconstructionconsistingof19rope-strandedmemberseachofwhichconsistof7bunch-strandedmemberswith32wireseach.B172 10 (2015)3

46、TABLE3ConstructionrequirementsofClassMRope-LayStrandedCopperConductorsHavingBunchStrandedMembersAAreaofCrossSectionWireDiameter0.0063In.(0.160mm)ApproximateMassBUncoatedCopperCoatedCoppercmilmm2SizeAWGNominalNumberofWiresStrandConstructionAbyBbyCCLb/1000ftKg/kmNominaldcresistance20CMaximumdcresistan

47、ce20CNominaldcresistance20CMaximumdcresistance20COhm/kftOhm/kmOhm/kftOhm/kmOhm/kftOhm/kmOhm/kftOhm/km1,000,000507.25,19361by7by59323948190.01110.03640.01130.03710.01190.03910.01210.0399900,000456.22,63161by7by53290943290.01230.04040.01250.04130.01320.04340.01350.0443800,000405.20,06961by7by472580383

48、90.01390.04560.01420.04640.01490.04890.01520.0499750,00380.18,78861by7by44241535940.01480.04860.01510.04950.01590.05210.01620.0531700,000355.17,50761by7by41225133490.01590.05220.01620.05300.01700.05580.01730.0569650,000329.16,22661by7by38208631040.01710.05610.01740.05710.01830.06010.01870.0613600,00

49、0304.14,94561by7by35192128590.01850.06070.01890.06190.01990.06510.02030.0664550,000279.13,66461by7by32175726140.02020.06630.02060.06750.02170.07110.02210.0725500,000253.12,69137by7by49163124280.02220.07280.02260.07430.02380.07820.02430.0798450,000228.11,39637by7by44146521800.02470.08100.02520.08250.02650.08690.02700.0885400,000203.10,10137by7by39129819320.02770.09090.02830.09280.02980.09770.03040.0997350,000177.8,80637by7by34113216850.03170.1040.03230.1060.03400.1120.03470.114300,000152.7,58119by7by5797514500.0

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM