ASTM B444-2006 Standard Specification for Nickel-Chromium-Molybdenum-Columbium Alloys (UNS N06625 and UNS N06852) and Nickel-Chromium-Molybdenum-Silicon Alloy (UNS N06219) Pipe and.pdf

上传人:arrownail386 文档编号:461251 上传时间:2018-11-25 格式:PDF 页数:4 大小:76.66KB
下载 相关 举报
ASTM B444-2006 Standard Specification for Nickel-Chromium-Molybdenum-Columbium Alloys (UNS N06625 and UNS N06852) and Nickel-Chromium-Molybdenum-Silicon Alloy (UNS N06219) Pipe and.pdf_第1页
第1页 / 共4页
ASTM B444-2006 Standard Specification for Nickel-Chromium-Molybdenum-Columbium Alloys (UNS N06625 and UNS N06852) and Nickel-Chromium-Molybdenum-Silicon Alloy (UNS N06219) Pipe and.pdf_第2页
第2页 / 共4页
ASTM B444-2006 Standard Specification for Nickel-Chromium-Molybdenum-Columbium Alloys (UNS N06625 and UNS N06852) and Nickel-Chromium-Molybdenum-Silicon Alloy (UNS N06219) Pipe and.pdf_第3页
第3页 / 共4页
ASTM B444-2006 Standard Specification for Nickel-Chromium-Molybdenum-Columbium Alloys (UNS N06625 and UNS N06852) and Nickel-Chromium-Molybdenum-Silicon Alloy (UNS N06219) Pipe and.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: B 444 06Standard Specification forNickel-Chromium-Molybdenum-Columbium Alloys(UNS N06625 and UNS N06852) and Nickel-Chromium-Molybdenum-Silicon Alloy (UNS N06219) Pipe and Tube1This standard is issued under the fixed designation B 444; the number immediately following the designation in

2、dicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies

3、 of the Department of Defense.1. Scope*1.1 This specification2covers nickel-chromium-molybdenum-columbium alloys (UNS N06625 and UNSN06852) and nickel-chromium-molybdenum-silicon alloy(UNS N06219)* in the form of cold-worked seamless pipe andtube. The general requirements for pipe and tube are cover

4、edby Specification B 829.1.1.1 UNS N06625 products are furnished in two grades ofdifferent heat-treated conditions:1.1.1.1 Grade 1 (annealed)Material is normally em-ployed in service temperatures up to 1100F (593C).1.1.1.2 Grade 2 (solution annealed)Material is normallyemployed in service temperatur

5、es above 1100F (593C) whenresistance to creep and rupture is required.NOTE 1Hot-working or reannealing may change properties signifi-cantly, depending on working history and temperatures.1.1.2 Alloys UNS N06219 and UNS N06852 are supplied inthe solution annealed condition only.1.2 The following prec

6、autionary caveat pertains only to thetest methods portion, Section 9, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to become familiar with all hazards includingthose id

7、entified in the appropriate Material Safety Data Sheet(MSDS) for this product/material as provided by the manufac-turer, to establish appropriate safety and health practices, anddetermine the applicability of regulatory limitations prior touse.2. Referenced Documents2.1 ASTM Standards:3B 829 Specifi

8、cation for General Requirements for Nickeland Nickel Alloys Seamless Pipe and Tube3. General Requirement3.1 Material furnished under this specification shall con-form to the applicable requirements of Specification B 829unless otherwise provided herein.4. Ordering Information4.1 Orders for material

9、to this specification shall includeinformation with respect to the following:4.1.1 Alloy name or UNS number,4.1.2 ASTM designation,4.1.3 Condition (temper) (see 1.1.1, 1.1.2, Section 6, andAppendix X1 and Appendix X2),4.1.3.1 If neither grade of N06625 is specified, Grade 1 willbe supplied.4.1.4 Fin

10、ish (See Appendix X2),4.1.5 Dimensions:4.1.5.1 TubeSpecify outside diameter and nominal orminimum wall,4.1.5.2 PipeSpecify standard pipe size and schedule,4.1.5.3 LengthCut to length or random,4.1.6 QuantityFeet (or metres) or number of pieces,4.1.7 Hydrostatic Test or Nondestructive Electric TestSp

11、ecify type of test (see 6.2),4.1.8 Hydrostatic Pressure RequirementsSpecify testpressure if other than required by 9.1.1,4.1.9 CertificationState if certification is required,4.1.10 Samples for Product (Check) AnalysisStatewhether samples for product (check) analysis should be fur-nished (see 5.2),1

12、This specification is under the jurisdiction of ASTM Committee B02 onNonferrous Metals and Alloys and is the direct responsibility of SubcommitteeB02.07 on Refined Nickel and Cobalt and Their Alloys.Current edition approved Dec. 1, 2006. Published January 2007. Originallyapproved in 1966. Last previ

13、ous edition approved in 2004 as B 444 - 04.* New designation established in accordance with Practice E 527 and SAEJ 1086, Practice for Numbering Metals and Alloys (UNS).2For ASME Boiler and Pressure Vessel Code applications see related Specifi-cation SB-444 in Section II of that Code.3For referenced

14、 ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright

15、 ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.11 Purchaser InspectionIf purchaser wishes to wit-ness tests or inspection of material at place of manufacture, thepurchase order must so state indicating which tests or inspec-tions are to b

16、e witnessed, and4.1.12 Small-Diameter and Light-Wall Tube (ConverterSizes)See Appendix X1 and Table 1.5. Chemical Composition5.1 The material shall conform to the composition limitsspecified in Table 2. One test is required for each lot as definedin Specification B 829.5.2 If a product (check) analy

17、sis is performed by thepurchaser, the material shall conform to the product (check)analysis variations in Table 2 of Specification B 829.6. Mechanical Properties and Other Requirements6.1 Tension Test The material shall conform to the tensileproperties specified in Table 1. The sampling and specimen

18、preparation are as covered in Specification B 829.6.2 Hydrostatic or Nondestructive Electric TestEach pipeor tube shall be subjected to either the hydrostatic test or to thenondestructive electric test. The type of test to be used shall beat the option of the manufacturer, unless otherwise specified

19、 inthe purchase order.7. Dimensions and Permissible Variations7.1 Permissible variations for material specified as small-diameter and light-wall tube (converter size) shall conform tothe permissible variations prescribed in Table X1.1 and TableX1.2.8. Number of Tests8.1 Chemical AnalysisOne test per

20、 lot.8.2 TensionOne test per lot.8.3 Hydrostatic or Nondestructive Electric TestEachpiece in each lot.9. Test Methods9.1 Hydrostatic TestEach pipe or tube with an outsidediameter18 in. (3 mm) and larger and with wall thickness of0.015 in. (0.38 mm) and over shall be tested in accordance withSpecific

21、ation B 829. The allowable fiber stress for material inthe condition furnished, is as follows:UNS N06625:Grade 130 000 psi (207 MPa)Grade 225 000 psi (172 MPa)UNS N06219:All24 000 psi (165 MPa)UNS N06852:All21 000 psi (145 MPa)9.1.1 When so agreed upon by the manufacturer and pur-chaser, pipe or tub

22、e may be tested to 112 times the allowablefiber stress given above.9.1.2 If any pipe or tube shows leak during hydrostatictesting, it shall be rejected.9.2 Nondestructive Electric TestEach pipe or tube shall beexamined with a nondestructive electric test as per prescribedin Specification B 829.10. K

23、eywords10.1 seamless pipe; seamless tube; N06219; N06625TABLE 1 Room Temperature Tensile Properties and HeatTreatment Including Small Diameter and Light-Wall Tubing(Converter Sizes)ABConditionTensileStrength,min, ksi(MPa)CYieldStrength(0.2 %offset),min, ksi(MPa)CElongationin2 in. or 50.8mm (or 4D),m

24、in, %Alloy N06625Grade 1 (annealed)D120 (827) 60 (414) 30Grade 2 (solution annealed)E100 (690) 40 (276) 30Alloy N06219All (solution annealed) 96 (660) 39 (270) 30Alloy N06852All (solution annealed) 85 (586) 35 (241) 30ANot applicable to outside diameters under18 in. (3.2 mm) and to wallthicknesses u

25、nder 0.015 in. (0.38 mm).BHot forming quality pipe and tubing is furnished to chemical requirements andsurface inspection only. No tensile properties are required.CThe minimum strength values apply only to tubing in straight lengths.DAnnealed at 1600F (871C) minimum.ESolution annealed at 2000F (1093

26、C) minimum, with or without subsequentstabilization anneal at 1800F (982C) minimum to increase resistance to sensi-tization.TABLE 2 Chemical RequirementsElementComposition Limits, %N06852 N06625 N06219Carbon 0.05 max 0.10 max 0.05 maxManganese 0.50 max 0.50 max 0.50 maxSilicon 0.50 max 0.50 max 0.70

27、-1.10Phosphorus 0.015 max 0.015 max 0.020 maxSulfur 0.015 max 0.015 max 0.010 maxChromium 20.0-23.0 20.0 min 18.0-22.0. 23.0 max .Columbium + tantalum . 3.15 min . 4.15 max .Columbium 0.51-1.00 . .Cobalt (if determined) . 1.0 max 1.0 maxMolybdenum 8.0-10.0 8.0 min 7.0-9.010.0 max .Iron 15.0-20.0 5.0

28、 max 2.0-4.0Aluminum 0.40 max 0.40 max 0.50 maxTitanium 0.40 max 0.40 max 0.50 maxCopper . . 0.50 maxNickelABal. 58.0 min Bal.AElement shall be determined arithmetically by difference.B444062APPENDIXES(Nonmandatory Information)X1. CONVERTER SIZESX1.1 Small-diameter and light-wall tube in outside dia

29、m-eters 114 in. (31.8 mm) and under may be furnished in a limitedrange of sizes and the manufacturer should be consulted as tothe various outside diameters and wall thicknesses that may befurnished. Material will have a bright finish. Such materialshall conform to the requirements in Tables X1.1 and

30、 X1.2.X2. CONDITIONS AND FINISHES NORMALLY SUPPLIEDX2.1 ScopeX2.1.1 This appendix lists the conditions and finishes inwhich pipe and tube (other than converter sizes) are normallysupplied. These are subject to change, and the manufacturershould be consulted for the latest information available.X2.2

31、Cold-Worked Tube and PipeX2.2.1 ColdDrawn, Annealed or Solution Annealed withGround Outside DiameterThe inside diameter may have abright finish when material is annealed or solution annealed ina protective atmosphere; otherwise, the inside diameter issupplied descaled as necessary. It is available i

32、n sizes12 to 4 in.(12.7 to 102 mm), incl, in outside diameter in both normal andheavy-wall tube, and pipe sizes, all schedules, of correspond-ing outside-diameter dimensions.X2.2.2 ColdDrawn, Annealed or Solution Annealed andPickled (Not Ground)Outside and inside diameter will havedull, matte (pickl

33、ed) surfaces. Available in sizes12 to 658 in.(12.7 to 168 mm), incl, in outside diameter in both normal andheavy-wall tube, and pipe sizes, all schedules, of correspond-ing outside-diameter dimensions.TABLE X1.1 Permissible Variations for Small-Diameter and Light-Wall Tube (Converter Sizes)A,B,C,D,E

34、 ,F,GSpecified Outside Diameter, in. (mm)Outside Diameter Inside Diameter Wall Thickness, %PlusMinus, in.(mm)Plus Minus Plus MinusUnder332 (2.4)332 to316 (2.4 to 4.8), excl0.002 (0.05)0.003 (0.08)00000.002 (0.05)0.003 (0.08)10101010316 to12 (4.8 to 12.7), excl 0.004 (0.10) 0 0 0.004 (0.10) 10 1012 t

35、o 114 (12.7 to 31.8), incl 0.005 (0.13) 0 0 0.005 (0.13) 10 10AOvality, Normal-Wall TubeOvality will be held within 2 % of the theoretical average outside diameter.BOvality, Light-Wall TubeOvality will be held within 3 % of the theoretical average outside diameter.CWall Tolerances, Light-Wall TubeTh

36、e plus and minus wall tolerance shown in the table shall apply down to and including 0.005 in. (0.13 mm) in wall thickness. Forwall thicknesses less than 0.005 in. (0.13 mm), the tolerance shall be 60.0005 in. (0.013 mm).DRandom Lengths:Where nominal random lengths on tubing18 in. (3.2 mm) and large

37、r in outside diameter are specified, a length tolerance of 6312 ft (1.07 m) applies to the nominal length.This is a total spread of 7 ft (2.13 m).Random lengths in sizes18 in. (3.2 mm) and larger in outside diameter shall be subject to a length range of 5 to 24 ft (1.52 to 7.32 m). Long random lengt

38、hs are subjectto a range from 15 to 22 ft (4.57 to 6.71 m).Random lengths in sizes up to, but not including18 in. (3.2 mm) in outside diameter, and fragile light-wall tubes over this outside diameter are subject to the length rangefrom 1 to 15 ft (0.30 to 4.57 m).ECut LengthsTolerances on cut length

39、s shall be in accordance with Table X1.1.FStraightnessRound tubing is subject to a straightness tolerance of 1 part in 600 equivalent to a depth of arc of 0.030 in. (0.76 mm) in any 3 ft (0.91 m) of length.GWhen specified, the tolerance spreads of this table may be applied as desired. However, when

40、not specified, the tolerances in this table will apply. It should be notedthat inside diameter tolerances are based upon the outside diameter range.TABLE X1.2 Tolerances on Cut Lengths of Light-Wall TubeLength, ft (m) Tube Size, in. (mm)Permissible Variations, in. (mm)Over UnderUnder 1 (0.30)1 to 4

41、(0.30 to 1.22), inclup to 1.250 (31.8), inclup to 1.250 (31.8), incl132 (0.8)116 (1.6)0(0)0(0)Over 4 to 10 (1.22 to 3.0), incl up to 1.250 (31.8), incl332 (2.4) 0 (0)Over 10 (3.0) up to 1.250 (31.8), incl316 (4.8) 0 (0)B444063SUMMARY OF CHANGESCommittee B02 has identified the location of selected ch

42、anges to this standard since the last issue (B 444 - 04)that may impact the use of this standard. (Approved December 1, 2006.)(1) Introduction of nondestructive electric test in lieu ofhydrostatic test at the option of the manufacturer.(2) Revision of 4.1, 6.2, 8.3, 9.1.2, and 9.2.ASTM International

43、 takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their ow

44、n responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be ad

45、dressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, a

46、t the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).B444064

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1