ASTM B813-2010 Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube《铜和铜合金管钎焊用液体和软膏状助溶剂的标准规范》.pdf

上传人:fuellot230 文档编号:462364 上传时间:2018-11-27 格式:PDF 页数:6 大小:109.66KB
下载 相关 举报
ASTM B813-2010 Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube《铜和铜合金管钎焊用液体和软膏状助溶剂的标准规范》.pdf_第1页
第1页 / 共6页
ASTM B813-2010 Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube《铜和铜合金管钎焊用液体和软膏状助溶剂的标准规范》.pdf_第2页
第2页 / 共6页
ASTM B813-2010 Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube《铜和铜合金管钎焊用液体和软膏状助溶剂的标准规范》.pdf_第3页
第3页 / 共6页
ASTM B813-2010 Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube《铜和铜合金管钎焊用液体和软膏状助溶剂的标准规范》.pdf_第4页
第4页 / 共6页
ASTM B813-2010 Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube《铜和铜合金管钎焊用液体和软膏状助溶剂的标准规范》.pdf_第5页
第5页 / 共6页
亲,该文档总共6页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: B813 10Standard Specification forLiquid and Paste Fluxes for Soldering of Copper andCopper Alloy Tube1This standard is issued under the fixed designation B813; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o

2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis specification covers a series of specific requirements for liquid and paste fluxes. It alsoincorporates a serie

3、s of test methods that establish the procedures on how to measure these properties.The format of this specification initially defines the specification requirements followed by the specifictest methods in the order in which they are to be performed.1. Scope1.1 This specification establishes the requ

4、irements and testmethods for liquid and paste fluxes for joining by soldering ofcopper and copper alloy tube and fittings in plumbing, heating,air conditioning, mechanical, fire sprinkler, and other similarsystems.NOTE 1This specification does not apply to fluxes intended forelectronic applications.

5、1.2 Solder fluxes are to be tested in accordance with therequirements of this specification by an independent testinglaboratory. Testing, measuring equipment, and inspection fa-cilities shall be of sufficient accuracy and quality to complywith the requirements of this specification.1.3 UnitsThe valu

6、es stated in SI units are to be regardedas standard. No other units of measurement are included in thisstandard.1.4 The following hazard caveat pertains to Sections 11-19.This standard does not purport to address the safety problems,if any, associated with its use. It is the responsibility of the us

7、erof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 The following documents of the issue in effect on thedate of materials purchase form a part of this specification tothe extent ref

8、erenced herein:2.2 ASTM Standards:2B32 Specification for Solder MetalB88 Specification for Seamless Copper Water TubeB88M Specification for Seamless Copper Water Tube (Met-ric)B152/B152M Specification for Copper Sheet, Strip, Plate,and Rolled BarB280 Specification for Seamless Copper Tube for Air Co

9、n-ditioning and Refrigeration Field ServiceB846 Terminology for Copper and Copper AlloysD130 Test Method for Corrosiveness to Copper from Pe-troleum Products by Copper Strip TestD1200 Test Method for Viscosity by Ford Viscosity Cup2.3 Other:1986 Amendments to the Safe Drinking Water Act33. General R

10、equirements3.1 The flux shall be suitable for joining copper tube andfittings by soldering in the size ranges shown in Table 1 ofSpecifications B88 and B88M and Tables 4 and 5 of Specifi-cation B280.3.2 The flux shall remain active over the temperature rangeof the soldering operation, removing and e

11、xcluding oxidesfrom the metal surfaces in the joint.1This specification is under the jurisdiction of Committee B05 on Copper andCopper Alloys and is the direct responsibility of Subcommittee B05.04 on Pipe andTube.Current edition approved April 1, 2010. Published April 2010. Originallyapproved in 19

12、91. Last previous edition approved in 2009 as B813 00 (2009).DOI: 10.1520/B0813-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary pa

13、ge onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.

14、3.3 The flux shall be suitable for use with all solders listedin Table 5 of Specification B32 as well as the more recentlydeveloped solder alloys suitable for the applications in thescope of this specification.3.4 The flux shall allow the solder to adequately wet andspread on the surfaces being sold

15、ered.3.5 The flux residue shall be water flushable after solderingas specified in accordance with Sections 7 and 9.3.6 The flux residue shall not be corrosive or toxic aftersoldering potable water systems.3.7 The flux shall not release toxic fumes during thesoldering operation or corrosive or toxic

16、substances into thewater inside or outside the completed system.3.8 The flux shall adhere to the copper and copper alloysunder anticipated temperature, joint geometry, joint position,job site, and weather conditions.3.9 The flux shall not contain more than 0.2 % lead inaccordance with the 1986 Amend

17、ments to the Safe DrinkingWater Act.4. Terminology4.1 For terms related to copper and copper alloys, refer toTerminology B846 for terms specific to this standard.4.2 Definition:4.2.1 flux, na chemically active substance that is used toremove and exclude oxides from the joint area during heatingand t

18、hat ensures that the melted solder will wet the surfaces tobe joined.5. Spreading Factor5.1 Spreading of the solder is determined by measuring theheight (h) of a solder bead on a standard test sheet followingthe specified heating cycle. Spread factor (SF) is calculated asfollows:SF 5 100 1.0 2 h! (1

19、)where:h = the maximum height of the solder bead, mm.5.2 A flux is considered to have acceptably influenced thespreading of solder on the copper surfaces when the averagespreading factor is at least 50 (see Section 13).5.3 The spreading test shall show a balanced action byforming a regular and even

20、solder layer.6. Aggressiveness Requirements6.1 From a standard test sheet on which a specimen hasbeen prepared with solder (see Section 15), the resistivity ofthe aqueous solution shall be more than 100 000 V cm.6.2 From a standard test sheet on which a specimen hasbeen prepared without solder (see

21、Section 16), the resistivity ofthe aqueous solution shall be more than 85 000 V cm.7. Corrosiveness Requirements7.1 There shall be a clear indication that in the areas of fluxreaction, the sheets shall show a corrosion and residue-freesurface comparable with the unwetted areas as determined byvisual

22、 inspection in accordance with Section 17.7.2 Corrosiveness shall be reported in accordance with oneof the classifications listed as follows (see Test Method D130):Classification Description1 Slight tarnish2 Moderate tarnish3 Dark tarnish8. Viscosity Requirements8.1 The viscosity of liquid fluxes sh

23、all be less than 180 s asdetermined using a No. 2 Ford flow cup in accordance withSection 18.9. Residue Flushing Requirements9.1 Flushing of the residue shall be determined by weightloss.9.2 The loss of weight of each sheet shall be determined bycomparing the average weight before and after the test

24、 proce-dure. The weight loss of the flux residue shall be more than99 % in accordance with Section 19.% Weight Loss d! 5 100 2c 2 a!b 2 a!3 100 (2)where:a = weight of degreased, flushing-test sheet, g;b = weight of degreased, flushing-test sheet plus theweight of applied flux, g; andc = weight of dr

25、ied, flushing-test sheet after flushing, g.10. Sampling10.1 Samples of flux taken for the purpose of the tests listedin this specification shall be selected from the stock of themanufacturer and shall be representative of the material beingevaluated.11. Specimen Preparation11.1 Standard Quantity of

26、Solder MetalA standard quan-tity of solder metal shall be a sample of 60:40 tin-lead (AlloyGrade Sn60), measuring 6.0 mm in diameter by 0.86 mm inthickness, weighing approximately 0.21 g, that has beendegreased with trichloroethylene.11.2 Standard Quantity of FluxAstandard quantity of fluxshall be 0

27、.003 mL as measured by a precision pipet or othervolumetric measuring devices with equivalent precision.11.3 Standard Test SheetA standard test sheet shall be apiece of copper 35 by 35 by 1 mm thick of Copper UNS No.C12200 (deoxidized high residual phosphorus) produced inaccordance with Specificatio

28、ns B152/B152M.11.3.1 Preparation:11.3.1.1 The sheet is abraded three times with a waterproofsand or emery paper (Grit No. 360), each time perpendicular tothe previous direction. One corner of each test sheet shall bebent upwards to permit handling. It is degreased with calciumcarbonate mixed with wa

29、ter to a paste consistency with whichthe test sheet is rubbed using a wad of cotton. The residue isflushed off by a strong jet of tap water. The test sheet isconsidered to be degreased when it is completely moistened bywater when flushed.B813 10211.3.1.2 In any of the following steps in which the te

30、stsheets must be handled, use forceps or laboratory tongs. Thesheet is then etched for 15 s in an etching solution formulatedas follows:(a) Etching Solution(1-L etching solution contains 200-gchromic acid anhydride (CrO3) and 125-mL sulfuric acid(specific gravity 1.84) reagent grade, balance distill

31、ed water,diluted to 1 L.)(b) Finally, the sheet is rinsed thoroughly with distilled water(60 to 70C), immersed in ethanol (ACS Grade), and allowedto dry.11.4 Resistivity Test SpecimenThe resistivity test speci-men is the condition of the standard test sheet on which havebeen deposited standard quant

32、ities of flux and solder metalbefore they are placed in the oven.11.4.1 Preparation:11.4.1.1 Remove test sheet from the liquid ethanol, allow todry, and apply a standard quantity of flux. With a standardquantity of solder metal, spread the flux to an area of about 15mm in diameter.11.4.1.2 Place the

33、 test sheet with flux and solder metal in theoven where it remains for 3 min at a temperature of 275Cfrom the time the solder melts. Remove the specimen andallow to cool to room temperature.11.5 Flushing-Test SheetThe flushing-test sheet is a pieceof copper 100 by 100 by 1.0 mm thick of Copper UNS N

34、o.C12200 (deoxidized high residual phosphorus) produced inaccordance with Specifications B152/B152M.11.5.1 Preparation:11.5.1.1 The copper sheets shall have raised edges of 3 or 4mm to avoid loss of flux. The sheets shall be degreased withtrichloroethylene, flushed with water, and dried at a tempera

35、-ture of 50C. Every sheet shall be weighed to 10-mg accuracyusing a standard laboratory balance.12. Test Methods12.1 The properties enumerated in this specification shall bedetermined in accordance with the test methods given inSections 13-19.13. Spreading Test13.1 ScopeThe influence of the flux on

36、the spreading ofthe fluid solder is indicated by the spreading factor obtained bythe conditions detailed in Section 17.13.2 Apparatus:13.2.1 OvenThe performance characteristics of the ovenshall be such that the temperature has an accuracy of 62.5C.The oven shall be equipped with a sight glass for vi

37、siblecontrol of the melting of the solder. It shall be possible tomeasure the oven temperature in close proximity to the testsheet. The test sheet shall be capable of being placed in theoven and removed from it exactly horizontally. To reducecooling when the preheated test sheet is removed from theo

38、ven, it is placed on a plate in an exact horizontal position soas to be pushed in and out. The oven must be easy to heat to thepreset temperature.13.2.2 Gilson Precision Pipet,3to25L.13.3 Spreading Factor Procedure:13.3.1 The spreading factor test specimen is the condition ofthe standard test sheet

39、with a standard quantity of flux havingbeen heated to 275C for 30 s in the oven. Immediatelyafterwards, a standard quantity of solder metal is placed overthe liquid flux and the test specimen is replaced in the oven.13.3.2 The period for which the test sheet shall be outsidethe oven for application

40、of the solder metal shall not exceed 10s.13.3.3 Remove test sheet from the ethanol, allow to dry, andapply a standard quantity of flux. Spread the flux with astandard quantity of solder metal to an area of about 15 mm indiameter and then remove the solder metal.13.3.4 Heat the test sheet with flux f

41、or 30 s in an oven at275C. Afterwards, replace the standard quantity of soldermetal that was used to spread the flux on the test sheet and heatthe assembly for 3 min at a temperature of 275C in the oven.13.3.5 After the test specimen has cooled to room tempera-ture and been cleaned, measure the sold

42、er height by means ofa flat micrometer three times, average the values, and calculatethe spreading factor as in 5.1.13.4 CalculationAfter five tests, the highest and lowestfigures are excluded. Calculate the average of the remainingthree.14. Aggressiveness Test14.1 ScopeThe aggressiveness of the flu

43、x is determinedby means of a resistivity test by measuring the resistivity in Vcm of an aqueous solution of the flux residue. The conductivitycell to be used shall be kept immersed in distilled water atambient temperature for a minimum of 24 h before use.14.2 Apparatus:14.2.1 Ohmmeter (Must Be Suita

44、ble for Use with Liquids)Cell constant shall be specified.14.2.2 Beakers100 mLfor this test shall be acid/alkaliresistant, cleaned, and degreased. Finally, they shall be rinsedthoroughly with distilled water.14.2.3 ThermometersThe temperatures shall be measuredwith cleaned thermometers having a scal

45、e that will accuratelyregister the temperatures. The thermometer shall be immersedin a clean graduate measuring cylinder, filled with distilledwater for a minimum of 24 h before use.14.3 CalculationAfter five tests, the highest and lowestfigures are excluded and the average of the other three is use

46、d.15. Resistivity TestSoldered (see 6.1)15.1 Procedure:15.1.1 Clean seven watch glasses and seven graduatedbeakers thoroughly by washing in hot water detergent solution,rinsing several times with tap water followed by rinsing threetimes with distilled water. Then add approximately 50 mL ofdistilled

47、water to each beaker, cover with a watch glass, andboil for 2 min. Discard the water and repeat this boiling withfresh distilled water. Place each clean beaker upside down ontissue paper until they are needed. Fill each beaker to the75-mL mark with distilled water. Immerse the beakers in awater bath

48、 maintained at 25C. When this temperature isreached, measure the resistivity of the distilled water in eachbeaker. Make sure that the resistivity of the distilled water ineach beaker is not less than 500 000 V cm. If the resistivity ofB813 103the water in any beaker is less than 500 000 V cm, repeat

49、 thecomplete process just described. Retain two of these beakers ascontrols.15.1.2 For determination of the resistivity, five of the testspecimens indicated in 11.4 are used. After cooling the lastsheet, five of the sheets (see 13.3.5) are placed in separatebeakers filled with 75-mL distilled water. The test sheets areplaced with the soldered surface down. The beakers are thencovered with watch glasses. Heat all seven beakers simulta-neously. As the contents of each beaker comes to a boil, timethe boiling for 1 min. The beakers are then allowed to