ASTM C1005-2010 Standard Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing of Hydraulic Cements《水硬水泥物理试验中质量和体积测定用标准质量与设.pdf

上传人:livefirmly316 文档编号:463031 上传时间:2018-11-27 格式:PDF 页数:3 大小:69.06KB
下载 相关 举报
ASTM C1005-2010 Standard Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing of Hydraulic Cements《水硬水泥物理试验中质量和体积测定用标准质量与设.pdf_第1页
第1页 / 共3页
ASTM C1005-2010 Standard Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing of Hydraulic Cements《水硬水泥物理试验中质量和体积测定用标准质量与设.pdf_第2页
第2页 / 共3页
ASTM C1005-2010 Standard Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing of Hydraulic Cements《水硬水泥物理试验中质量和体积测定用标准质量与设.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: C1005 10Standard Specification forReference Masses and Devices for Determining Mass andVolume for Use in the Physical Testing of HydraulicCements1This standard is issued under the fixed designation C1005; the number immediately following the designation indicates the year oforiginal ado

2、ption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the minimum requirements forscales, balances,

3、 reference masses, and glass graduates used inthe physical testing of hydraulic cements.1.2 Requirements for analytical reference masses and bal-ances are not included in this specification, but are to be foundin Test Methods C114. The use of restrictive terminology,classes, ranges, etc. has been in

4、tentionally avoided to allow theuse of this specification by other standards-writing bodies withsimilar requirements for reference masses and devices fordetermining mass, if desired.1.3 These requirements are not sufficiently descriptive to beused as the sole specifications for the purchase of refer

5、encemasses or devices for determining mass without amplification.1.4 Values in SI units shall be obtained by measurement inSI units or by appropriate conversion, using the Rules forConversion and Rounding given in IEEE/ASTM SI10,ofmeasurement made in other units.2. Referenced Documents2.1 ASTM Stand

6、ards:2C114 Test Methods for Chemical Analysis of HydraulicCementE617 Specification for Laboratory Weights and PrecisionMass StandardsIEEE/ASTM SI10 Standard for Use of the InternationalSystem of Units (SI): The Modern Metric System3. Terminology3.1 Definitions:3.1.1 accuracy, ndegree of conformity o

7、f the indicationof a device for determining mass to the true value of an appliedmass.3.1.2 balance, na device for determining mass that com-pares a mass with standard masses.3.1.3 precision, nreproducibility of the readings of adevice for determining mass when a given test mass is applied.3.1.4 rang

8、e of mass determination, nthe range of indica-tions of a device from the minimum test load plus any aids orcontainers on the load-receiving elements to the maximum testload with the same aids or containers, as specified by theparticular method of test being used.3.1.5 readability, nthe smallest frac

9、tion of a division towhich the index scale of a device for determining mass can beread with ease either by estimation or by use of a vernier.3.1.6 reference mass, na piece of material of knownspecified mass for use in comparing or measuring the mass ofother masses (See Note 1).3.1.6.1 DiscussionThe

10、definition of “reference mass” wasformerly incorrectly designated “weight;” weight is a force(See IEEE/ASTM SI10).3.1.7 scale, na device for determining mass having aload-receiving element and an index scale (possibly in combi-nation with the use of internal masses or proportional masses),almost alw

11、ays calibrated to indicate mass; generally of lesseraccuracy than a balance.3.1.8 sensitivity, nthe minimum change of applied massrequired to perceptibly move the indicating element of a devicefor determining mass.3.1.9 sensitivity requirement, nthe minimum change inposition of rest of the indicatin

12、g element of a device fordetermining mass in response to a specified change of massload on the load-receiving element.3.1.10 test load, nthe mass to be determined in a singledetermination, exclusive of aids or containers, as specified inthe test method being followed.3.1.11 tolerance, nprecision and

13、 accuracy criteria forreference masses or devices for determining mass.acceptance tolerancethe maximum permissible deviationfrom correct indication for new or newly reconditioned or1This specification is under the jurisdiction of ASTM Committee C01 onCement and is the direct responsibility of Subcom

14、mittee C01.95 on Coordination ofStandards.Current edition approved Dec. 1, 2010. Published January 2011. Originallyapproved in 1983. Last previous edition approved in 2005 as C100505. DOI:10.1520/C1005-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer S

15、ervice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.adjusted reference masses or devices for

16、determining mass;equal to12 the maintenance tolerance.adjustment toleranceacceptance tolerance.maintenance tolerancemaximum permissible deviationfrom correct indication for reference masses and devices fordetermining mass in service.3.1.12 total load, nthe sum of the masses of materials andaids or c

17、ontainers applied to the load-receiving element at anyone time.4. Reference Masses4.1 Reference masses for use in the methods of physicaltesting of hydraulic cement and related and similar materialsshall conform at least to the requirements of Class 6 referencemasses in Specification E617, except th

18、at the maintenancetolerances given in Specification E617 for Class 6 referencemasses are to be considered acceptance tolerances for purposesof this specification and the maintenance tolerances twice thesevalues. See Table 1. (See Note 1)NOTE 1Former NBS Class P and F reference masses meet thisspecif

19、ication as do OIML Class M1 reference masses. Former NBS ClassT reference masses of 100 mg and less, Class C reference masses of 1 kgand greater, and OIML Class M2 reference masses of 200 g and greatermeet the specification.4.2 A mass used strictly as a mass, whose actual value neednot be known, nee

20、d not meet the requirements of 4.1 (See Note2).NOTE 2A tare mass for a container used in mass determination is inthis category. The actual value of its mass need not be known, but it mustbe equal in mass to that of the container.5. Requirements for Scales and Balances Requirements forScales and Bala

21、nces5.1 CapacityThe capacity of a device for mass determi-nation shall be at least equal to the maximum total load to beapplied to the load-receiving element at any one time (See Note3).NOTE 3In general, the capacity of a device for mass determinationshould not greatly exceed twice the maximum total

22、 load required for agiven test because of the reduced accuracy, readability, and sensitivitywith higher capacity weighing devices. There are exceptions to thisgenerality as, for example, the high quality substitution balances.5.2 Precision and AccuracyThe maintenance tolerancefor a device for mass d

23、etermination shall be no greater than0.05 % of the test load throughout the range. For balances witha capacity of 3000 g or more, the range of the test load shall be300 to 3000 g. For balances with a capacity of less than 3000g, the range of the test load shall be 10 % of the capacity up tothe capac

24、ity of the balance. The device for mass determinationshall be capable of reproducing readings with the same testmass to within at least the maintenance tolerance.5.3 ReadabilityThe index scale of a device for massdetermination shall be easily readable to 0.1 g.5.4 Sensitivity RequirementThe indicati

25、ng element of thedevice for determination of mass shall show a change of atleast one of the smallest divisions of the index scale for achange of 0.1 % of the test load within the range.6. Requirements for Glass Graduates6.1 Glass Graduates, of suitable capacities (large enough tomeasure the mixing w

26、ater for paste and mortar mixtures in asingle operation) shall be made to deliver the indicated volumeat 20C (68F).6.1.1 The permissible variation for graduates of 100 to150-mL capacities shall be 61.0 mL, for graduates of 200 to300-mL capacities 62.0 mL, and for all larger graduates60.5 % of the ra

27、ted capacity.6.1.2 These graduates shall be subdivided to at least 5 mLwith the following exceptions:6.1.2.1 The graduation lines may be omitted for the lowest15 mL for a 150-mL graduate,6.1.2.2 The graduation lines may be omitted for the lowest25 mL for a 250-mL graduate, and6.1.2.3 The graduation

28、lines may be omitted for the lowest50 mL for a 500-mL graduate.6.1.3 The main graduation lines shall extend at least threequarters of the way around the graduate and shall be numbered(Note 4).NOTE 4Some graduates are manufactured with two numbering sys-tems; one on each side of the main graduation l

29、ines. In reading frombottom to top, one system is increasing while on the other side thenumbers are decreasing. Care should be taken since this could createconfusion in reading the volume.7. Verification Timing7.1 New or newly reconditioned or adjusted referencemasses and devices for determination o

30、f mass shall not beTABLE 1 Tolerances for Reference MassesA,BMass, gAcceptanceTolerance,6mgMaintenanceTolerance,6mg10 000 1 000 2 0005 000 500 1 0003 000 300 6002 000 200 4001 000 100 200500 50 100300 30 60200 20 40100 10 2050 7 1430 5 1020 3 610 2 4523222412AValues from Table 1 of Specification E61

31、7 for Class 6 metric referencemasses.BFor reference masses with unlisted nominal values, the tolerance shall be thatfor the next lower denomination listed.C1005 102placed in service if they do not meet the acceptance tolerancesspecified in this standard.7.2 Reference masses and devices for determina

32、tion of massin service shall be checked annually and shall be removed fromservice if they exceed the maintenance tolerances specified inthis standard (See Note 5).NOTE 5An optional performacne verification procedure is provided inAppendix X1.8. Keywords8.1 devices for determining mass; devices for m

33、easuringvolume; glass graduate; reference massesAPPENDIX(Nonmandatory Information)X1. SCALE AND BALANCE PERFORMANCE VERIFICATIONX1.1 This check mass verification procedure may be usedto verify the continuing precise performance of a scale orbalance. Perform this procedure in addition to the annualve

34、rification procedure.X1.1.1 The verification check mass shall be made ofcorrosion-resisting material (for example, material conformingto Specification E617 Class 6 masses) and shall have a stablemass. The check mass used for this purpose need not conformto any tolerance.X1.1.2 The check mass must sa

35、tisfy the size requirementsfor the reference test mass as described in the “Precision andAccuracy” paragraph (5.2).X1.1.3 Dedicate the check mass to the verification processto prevent any alternate uses from damaging or altering themass.X1.1.4 Make one mass determination using a single checkmass on

36、the selected scale or balance.X1.1.5 Maintain documentation of this verification in thelaboratory. Include in the documentation the date and the massdetermination when verified. If the difference between thecurrent reading and the previous reading exceeds the mainte-nance tolerance of the similar si

37、zed reference mass as listed inTable 1, test the balance or scale for conformance to thisstandard with reference masses and adjust or replace the scaleor balance as appropriate.X1.1.6 In the event of an adjustment or replacement, estab-lish a new check mass determination value for the verificationan

38、d make no comparison until the next scheduled verification.X1.1.7 Perform this procedure routinely and whenever scaleor balance performance verification is desired.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this

39、standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be r

40、eviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of therespon

41、sible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West

42、 Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).C1005 103

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1