ASTM C1052-2014 Standard Practice for Bulk Sampling of Liquid Uranium Hexafluoride《液体六氟化铀散装取样标准操作规程》.pdf

上传人:priceawful190 文档编号:463157 上传时间:2018-11-27 格式:PDF 页数:4 大小:82.81KB
下载 相关 举报
ASTM C1052-2014 Standard Practice for Bulk Sampling of Liquid Uranium Hexafluoride《液体六氟化铀散装取样标准操作规程》.pdf_第1页
第1页 / 共4页
ASTM C1052-2014 Standard Practice for Bulk Sampling of Liquid Uranium Hexafluoride《液体六氟化铀散装取样标准操作规程》.pdf_第2页
第2页 / 共4页
ASTM C1052-2014 Standard Practice for Bulk Sampling of Liquid Uranium Hexafluoride《液体六氟化铀散装取样标准操作规程》.pdf_第3页
第3页 / 共4页
ASTM C1052-2014 Standard Practice for Bulk Sampling of Liquid Uranium Hexafluoride《液体六氟化铀散装取样标准操作规程》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: C1052 14Standard Practice forBulk Sampling of Liquid Uranium Hexafluoride1This standard is issued under the fixed designation C1052; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number i

2、n parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers methods for withdrawing represen-tative samples of liquid uranium hexafluoride (UF6) from bulkquantities of the material.

3、Such samples are used for determin-ing compliance with the applicable commercial specification,for example Specification C787 and Specification C996.1.2 It is assumed that the bulk liquid UF6being sampledcomprises a single quality and quantity of material. Thispractice does not address any special a

4、dditional arrangementsthat might be required for taking proportional or compositesamples. When the sampled bulk material is being added toUF6residues already in a container (“heels recycle”) additionalarrangements are required to avoid cross contamination of thebulk UF6, these are addressed in the a

5、ppropriate section (8.2)of Specifications C787 and C996.1.3 The number of samples to be taken, their nominalsample weight, and their disposition shall be agreed uponbetween the parties.1.4 The scope of this practice does not include provisionsfor preventing criticality incidents.1.5 This standard do

6、es not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Sta

7、ndards:2C787 Specification for Uranium Hexafluoride for Enrich-mentC996 Specification for Uranium Hexafluoride Enriched toLess Than 5 %235U2.2 Other Documents:USEC-651 Uranium Hexafluoride: A Manual of Good Han-dling Practices3ANSI N14.1 Uranium Hexafluoride: Packaging for Trans-port4ISO/DIS 7195 Pa

8、ckaging of Uranium Hexafluoride (UF6)for Transport43. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 containerthe bulk vessel either holding or receivingby transfer, the UF6to be sampled; it may consist of, forexample, a fixed vessel in a UF6handling plant or a cylinder tobe use

9、d for the transport of UF6.3.1.2 sample bottlethe small vessel into which the sampleof UF6is withdrawn for transfer to the laboratory for charac-terization.4. Summary of Practice4.1 Two methods of withdrawing a sample are described,namely: (1) direct withdrawal from a filled container and (2)withdra

10、wal from the inlet-line during the filling of a containerby liquid transfer. The first method involves tilting or turningthe container in such a way that its valve is below the surfaceof the liquefied UF6, and dependent on the equipment, thisrequires that the container holds more than a specified mi

11、ni-mum quantity of UF6. Liquid UF6is withdrawn into agraduated volume and then transferred to the respective samplebottle(s). In the second method, a small proportion of the UF6flowing from one container to another is withdrawn into agraduated volume and then transferred to the respective samplebott

12、le(s).4.2 For both methods of sampling, the presence of residuesmay have significant implications for the quality of the UF6.For safety and quality reasons, containers and bottles shall beclean, dry, and empty before filling.4.3 Various types of sample bottles are in use and aredescribed in detail i

13、n the applicable national and international1This practice is under the jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.02 on Fuel andFertile Material Specifications.Current edition approved Jan. 15, 2014. Published February 2014. Originall

14、yapproved in 1985. Last previous edition approved in 2007 as C1052 01 (2007).DOI: 10.1520/C1052-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Doc

15、ument Summary page onthe ASTM website.3Available from United States Enrichment Corp., 6903 Rockledge Dr., Bethesda,MD 20817.4Available from American National Standards Institute, 11 W. 42nd St., 13thFloor, New York, NY 10036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Cons

16、hohocken, PA 19428-2959. United States1standards, for example, ANSI N14.1 and ISO/DIS 7195. For agiven type of sample bottle, the detailed configuration, forexample, valve orientation, terminal fittings, and the like, mayvary. Hence, the type and configuration of bottles to be used forthe withdrawal

17、 of samples shall be agreed upon between theparties.5. Significance and Use5.1 Uranium hexafluoride is normally produced and handledin large (typically 1- to 20-ton) quantities and must, therefore,be characterized by reference to representative samples. Thequantities involved, physical properties, c

18、hemical reactivity,and hazardous nature of UF6are such that for representativesampling, specially designed equipment must be used andoperated in accordance with the most carefully controlled andstringent procedures. This practice indicates appropriateprinciples, equipment, and procedures currently i

19、n use for bulksampling of liquid UF6. It is used by UF6converters, enrichers,and fuel fabricators to review the effectiveness of existingprocedures or as a guide to the design of equipment andprocedures for future use.5.2 It is emphasized that this practice is not meant to addressconventional or nuc

20、lear criticality safety issues.6. Hazards6.1 Because of its chemical, radiochemical, and toxicproperties, UF6is a hazardous material. UF6is very reactiveand corrosive. It reacts readily with water, atmosphericmoisture, certain metals, and many organic materials. Forreasons of safety and to avoid con

21、tamination, precautions mustbe taken to avoid contact with such materials. Suitable han-dling procedures are described in USEC-651.7. Principles7.1 The essential purpose of the sample is to be represen-tative of the bulk material for the purpose of determiningcompliance with the applicable material

22、specification. Toensure that the sample is representative for this purpose, certainprinciples, as described below, must be observed.7.2 Special attention must be given to ensuring that the bulkmaterial from which the sample is withdrawn is homogeneous,particularly in those circumstances when it has

23、been preparedby the blending together of materials having different compo-sitions. In practice, the low viscosity, and hence easy mobility,of liquid UF6facilitates the process of homogenization by theaction of convection currents within the bulk upon heating. Itis necessary to determine and establis

24、h for each set of samplingequipment the physical conditions, normally a combination ofthe minimum time and temperature for which liquefied ura-nium hexafluoride is held, which guarantee homogeneity of thebulk UF6.7.3 The sampling equipment is fabricated to appropriatehigh standards of vacuum integri

25、ty, and components in directcontact with UF6are made from nickel, high-nickel alloys, ormaterials having equivalent resistance to UF6corrosion. Theformation of an inert fluoride layer is often an important featureof UF6corrosion resistance, and hence, internal surfaces aregenerally conditioned with

26、a suitable fluorinating agent, some-times UF6itself.7.4 Cross-contamination may occur between subsequentsamples taken using the same equipment, and appropriateprecautions must be taken to prevent this. It is thereforerecommended that, before taking definitive samples, the equip-ment is flushed throu

27、gh with an aliquot of the material to besampled. This is normally accomplished by taking an initialvolume which is then rejected and not used for definitiveanalysis. Alternative procedures to prevent cross-contamination are possible and should be validated individu-ally.7.5 If the sample bottles are

28、 taken for an analytical needsuch as liquid UF6subsampling for P10 tubes or liquid UF6transfer for FTIR quantification, it is recommended, in order tominimize the gas phase contribution to the sample bottle, to fillthe bottle with more than 10% of its total volume.8. Procedure for Sampling Directly

29、from FilledContainers (see Fig. 1)8.1 The equipment consists of a sample manifold that isconnected directly to the valve of the transport container andhas facilities for connecting one or more sample bottles. Thegraduated volume is appropriately sized so that when filledeither completely or visually

30、 to a predetermined level it willcontain a known quantity of UF6. The graduated volume mayconsist of the manifold and associated pipework, or mayinclude an additional metering volume (pipette). The equip-ment may be designed to withdraw either single or multiplesample quantities of UF6at each operat

31、ion. The total graduatedvolume of the connected equipment (excluding the vacuumsystem) should not exceed the designated maximum fill vol-ume of the connected sample bottles. Certain valves may beremotely operated as necessary. The sampling equipment mustbe heated to prevent solidification of the UF6

32、and may belocated within the same heated enclosure as the container. Thesample bottles may be heated separately to permit independentcooling, if necessary.FIG. 1 Schematic Arrangement for Sampling Directly from aFilled ContainerC1052 1428.2 Load the container to be sampled into the heatingenclosure

33、(for example, autoclave) and attach the samplingequipment, including sample bottles. Evacuate and test theequipment to ensure vacuum integrity.8.2.1 When local safety regulations permit, a container ofhot, liquid UF6may be loaded into the sampling equipment andthe sample bottles attached.8.3 Heat th

34、e bulk UF6for a sufficient period to ensurehomogeneity in accordance with the procedure established forthe equipment (see 7.2). During heating, monitor and check thevapor pressure against the applicable pressure limit (if any) toensure compliance with the relevant specification and mainte-nance of a

35、 safe pressure level. In case of overpressure, followappropriate procedures.8.4 When the conditions for homogeneity have been met,withdraw the appropriate quantity of liquid UF6into thegraduated volume. This is usually effected by changing theposition of the container in such a way, for example, by

36、tiltingor turning, that the UF6flows under the influence of gravityand any differential pressures established within the equip-ment. Restore the container to its original position leaving thegraduated volume filled with liquid UF6. This may be indicatedby the use of suitable temperature sensors or p

37、ressure trans-ducers or strain gages.8.5 If the equipment is designed to withdraw a singlesample at each operation, open the appropriate sample valve toallow the UF6to flow into the sample bottle. Isolate the samplebottle from the sampling manifold.8.5.1 The first sample may be used to condition int

38、ernalsurfaces of the equipment (see 7.3) by suitable manipulation ofthe vacuum system or rejected to prevent cross-contaminationfrom previously sampled materials or both (see 7.4).8.5.2 Take successive samples by repeating steps 8.4 and8.5 as necessary.8.6 If the equipment is designed to withdraw mu

39、ltiplesamples at each operation, transfer the samples to the samplebottles by operating the valves associated with the successivesample bottles in the appropriate sequence.8.7 At the completion of sampling, close the container valveand evacuate the sampling equipment through the vacuumsystem to remo

40、ve residual UF6.8.8 Fill the equipment to atmospheric pressure with dry gasand remove, identify, cap, and weigh the sample bottles. Localsafety regulations may demand that the UF6is allowed to cooland solidify (below atmospheric pressure) before this operationis carried out.9. Procedure for Sampling

41、 During Filling of TransportContainers (see Fig. 2)9.1 The equipment consists of a sample manifold that hasfacilities for connecting one or more sample bottles and isconnected to the filling manifold between the main andsecondary (for example, transport) containers. The graduatedvolume is appropriat

42、ely sized to contain the quantity of UF6required for a single sample and normally consists of themanifold and associated pipework itself or may include anadditional metering volume (pipette). The total graduatedvolume of the connected equipment (excluding the vacuumsystem) should not exceed the desi

43、gnated maximum fill vol-ume of the attached sample bottles. Certain valves may beremotely operated as necessary. Heat the sampling equipmentto prevent the solidification of UF6. The sample bottles may becontained in a separate enclosure to permit independent cool-ing if necessary (see 9.6).9.2 Condi

44、tions for homogeneity must be met within the UF6main container immediately before the run-off to the secondary(for example, transport) container (see 7.2). This main con-tainer may typically be a plant vessel (for example, condenser)or another larger transport container (mother-container). Inorder t

45、o ensure that representative samples are obtained in caseof the presence of particles in the UF6, careful attention shouldbe taken when choosing the appropriate time for samplingbecause of rapid sedimentation. Alternative sampling methodssuch as a composite of several random samples or analysisbased

46、 on a sedimented sample may be agreed upon betweenbuyer and seller.9.3 Attach the sampling equipment, including samplebottles, at the relevant location to the UF6runoff line. Evacuateand test the equipment to ensure vacuum integrity. Isolate thesample bottles from the sample manifold.9.4 Establish l

47、iquid transfer of UF6from the main containerto the secondary container.9.5 At an appropriate time, open the sampling valve andwithdraw the required quantity of UF6into the graduatedvolume. This may be indicated by the use of suitable tempera-ture sensors or pressure transducers or strain gages.FIG.

48、2 Schematic Arrangement for Sampling During the Filling ofa Transport ContainerC1052 1439.6 Close the sampling valve and open the first samplebottle valve to transfer the sample. The equipment should bedesigned to allow transfers to take place using the influence ofgravity and differential pressures

49、 induced by temperaturegradients. For this purpose, it may be necessary to cool thereceiving sample bottles.9.6.1 The first sample may be used to condition internalsurfaces of the equipment (see 7.3) by suitable manipulation ofthe vacuum system or rejected to prevent cross-contaminationfrom earlier materials or both (see 7.4).9.7 Isolate the sample bottle from the sampling manifold.9.8 If successive samples are to be taken, repeat 9.5 and 9.6.If not, the volume of the pipette should be adapted so that thesample taken is representative of material transferred from themain cylinde

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1