1、Designation: C 1101/C 1101M 06Standard Test Methods forClassifying the Flexibility or Rigidity of Mineral FiberBlanket and Board Insulation1This standard is issued under the fixed designation C 1101/C 1101M; the number immediately following the designation indicates theyear of original adoption or,

2、in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the procedures for the classi-fication of mineral fiber

3、 insulation as flexible, resilient flexible,semirigid, or rigid.1.2 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard. Within the text, theSI units are shown in brackets. The values stated in eachsystem are not exact equivalents; therefore, each system

4、 mustbe used independently of the other.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory

5、limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 168 Terminology Relating to Thermal Insulation3. Terminology3.1 DefinitionsTerminology C 168 shall be considered asapplying to the terms used in these test methods.4. Significance and Use4.1 Classification of insulation relative t

6、o flexibility orrigidity is useful in establishing installation and applicationcharacteristics.5. Apparatus5.1 Iron Pipe,12-in. NPS (outside diameter 0.840 in. 21.3mm) measuring at least 12 in. 305 mm in length.5.2 Rigidity Tester, consisting of two horizontal, parallel,12-in. NPS iron pipe supports

7、 (outside diameter 0.840 in. 21.3mm) at least 24 in. 610 mm long and spaced 30 in. 762 mmapart and horizontally to each other.6. Sampling6.1 Atest sample shall consist of one representative packageof insulation. One test specimen measuring 12 in. by 12 in.305 by 305 mm and of full thickness shall be

8、 randomly cutfrom the sample for flexibility testing. If the rigidity portion ofthe procedure is to be performed, a test specimen measuring 32in. 813 mm long, and between 6 and 24 in. 152 and 610 mmwide, and of full thickness shall be randomly cut from thesample.7. Procedure7.1 Test for FlexibilityB

9、end the 12 by 12-in. 305 by305-mm piece of insulation over the12 in. NPS iron pipethrough an angle of 90 and examine the outer surface forvisible rupture.7.2 Test for Resilient FlexibilityIf no rupture occurs afterundergoing the 90 bending in 7.1, release the bent insulation.7.3 If the insulation is

10、 not classified as flexible or resilientflexible, it shall be tested in accordance with 7.4 to determinethe degree of rigidity.7.4 Test for Semirigidity and RigidityPlace the 32 in. 813mm long piece of insulation on the two horizontal, parallel,12-in. NPS iron pipe supports spaced 30 in. 762 mm apar

11、t.After 5 min have elapsed, measure the sag of the insulation tothe nearest 0.05 in. 1.3 mm at the center of the span, from astraight line connecting two points on the insulations surfacedirectly above the supports.8. Interpretation of Results8.1 Test for FlexibilityIf there is no visible rupture,cl

12、assify the material as flexible.8.2 Test for Resilient FlexibilityIf the insulation is classi-fied as flexible in accordance with 8.1 and it springs back to itsoriginal form when it is released, classify it as resilient flexible.8.3 Test for Semirigidity:1These test methods are under the jurisdictio

13、n of ASTM Committee C16 onThermal Insulation and are the direct responsibility of Subcommittee C16.32 onMechanical Properties.Current edition approved Nov. 1, 2006. Published Nov. 2006. Originallyapproved in 1988. Last previous edition approved in 2000 as C 1101/C 1101M 00.2For referenced ASTM stand

14、ards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, P

15、A 19428-2959, United States.8.3.1 If the sag is greater than12 in. 13 mm, the product isclassified as semirigid.8.3.2 If the test material fails to remain suspended, it isneither semirigid nor rigid and must be classified by theflexibility test as flexible or resilient flexible.8.4 Test for Rigidity

16、If, after undergoing the test in 7.4, thesag is12 in. 13 mm or less, the product is classified as rigid.8.5 Due to the inaccuracy of the sag measurement, there isan uncertainty of 0.05 in. 1.3 mm. Therefore, for sagmeasurements at the rigid-semirigid determination point, agreater number of sample me

17、asurements is necessary in orderto make a valid determination of rigidity.9. Precision and Bias9.1 No information is presented about either the precision orbias for Test Methods C 1101/C 1101M for classifying flex-ibility or rigidity since the test results are nonquantitative.10. Keywords10.1 flexib

18、ility; mineral fiber; resilient flexibility; rigidity;semirigidity; thermal insulationASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of t

19、he validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Yo

20、ur comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comment

21、s have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).C 1101/C 1101M 062

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1