ASTM C1270-1997(2003) Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors《内置穿过式金属探测器探测灵敏度标志的标准实用规程》.pdf

上传人:priceawful190 文档编号:464010 上传时间:2018-11-27 格式:PDF 页数:10 大小:173.35KB
下载 相关 举报
ASTM C1270-1997(2003) Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors《内置穿过式金属探测器探测灵敏度标志的标准实用规程》.pdf_第1页
第1页 / 共10页
ASTM C1270-1997(2003) Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors《内置穿过式金属探测器探测灵敏度标志的标准实用规程》.pdf_第2页
第2页 / 共10页
ASTM C1270-1997(2003) Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors《内置穿过式金属探测器探测灵敏度标志的标准实用规程》.pdf_第3页
第3页 / 共10页
ASTM C1270-1997(2003) Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors《内置穿过式金属探测器探测灵敏度标志的标准实用规程》.pdf_第4页
第4页 / 共10页
ASTM C1270-1997(2003) Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors《内置穿过式金属探测器探测灵敏度标志的标准实用规程》.pdf_第5页
第5页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: C 1270 97 (Reapproved 2003)Standard Practice forDetection Sensitivity Mapping of In-Plant Walk-ThroughMetal Detectors1This standard is issued under the fixed designation C 1270; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re

2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONNuclear regulatory authorities require personnel entering designated security areas to be screene

3、dfor concealed weapons. Additionally, in security areas containing specified quantities of specialnuclear materials, exiting personnel are required to be screened for metallic nuclear shielding material.Walk-through metal detectors are widely used to implement these requirements.A number of environm

4、ental conditions, architectural and electrical arrangements near the detector,and detector characteristics affect the detection of metallic objects passing through the walk-throughmetal detector. These external effects and detector characteristics are discussed in Practices F 1468 andC 1269, and Gui

5、de C 1238. This practice is intended to minimize the effects of these variables ondetector operation by providing the operator with baseline information on the metal detectionsensitivity within the portal aperture, particularly the location of any weak areas of detection. The datais obtained by mapp

6、ing the detection zone (volume within the portal) of each detector at its fieldlocation, under normal operating conditions, and using the target test object. The maps, when appliedto detector operation, ensure that the effects of the fixed environmental conditions, architectural andelectrical arrang

7、ements, and detector characteristics are taken into account during operationalsensitivity adjustment, performance evaluation, and general operation of detectors.1. Scope1.1 This standard practice covers a procedure for determin-ing the weakest detection path through the portal aperture andthe worst-

8、case orthogonal orientation of metallic test objects. Itresults in detection sensitivity maps, which model the detectionzone in terms related to detection sensitivity and identify theweakest detection paths. Detection sensitivity maps supportsensitivity adjustment and performance evaluation procedur

9、es(see Practices C 1269 and C 1309).NOTE 1Unsymmetrical metal objects possessing a primary longitudi-nal component, such as handguns and knives, usually have one particularorientation that produces the weakest detection signal. The orientation andthe path through the detector aperture where the weak

10、est response isproduced may not be the same for all test objects, even those with verysimilar appearance.NOTE 2In the case of multiple specified test objects or for test objectsthat are orientation sensitive, it may be necessary to map each objectseveral times to determine the worst-case test object

11、 or orientation, orboth.1.2 This practice is one of several developed to assistoperators of walk-through metal detectors with meeting themetal detection performance requirements of the responsibleregulatory authority. (See Appendix X2)1.3 This practice is neither intended to set performancelevels, n

12、or limit or constrain operational technologies.1.4 This practice does not address safety or operationalissues associated with the use of walk-through metal detectors.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.2. Refere

13、nced Documents2.1 ASTM Standards:C 1238 Guide for Installation of Walk-Through Metal De-tectors2C 1269 Practice for Adjusting the Operational SensitivitySetting of In-Plant Walk-Through Metal Detectors2C 1309 Practice for Performance Evaluation of InPlantWalkThrough Metal DetectorsF 1468 Practice fo

14、r the Evaluation of Metallic Weapons1This practice is under the jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.12 on SafeguardApplications.Current edition approved Dec. 10, 1997. Published June 1998. Originallyapproved in 1997. Last previ

15、ous edition approved in 1997 as C 127097.2Annual Book of ASTM Standards, Vol 12.01.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Detectors for Controlled Access Search and Screening33. Terminology3.1 Definitions of Terms Specific t

16、o This Standard:3.1.1 clean-tester, na person who does not carry anyextraneous metallic objects that would significantly alter thesignal produced when the person carries a test object.3.1.1.1 DiscussionBy example but not limitation, suchextraneous metallic objects may include: metallic belt buckles,

17、metal buttons, cardiac pacemakers, coins, metal frame eyeglasses, hearing aids, jewelry, keys, mechanical pens andpencils, shoes with metal shanks or arch supports, metallicsurgical implants, undergarment support metal, metal zippers,etc. In the absence of other criteria, a clean tester passingthrou

18、gh a metal detector shall not cause a disturbance signalgreater than 10 % of that produced when carrying the criticaltest object through the detector. Test objects requiring veryhigh sensitivity settings for detection require more completeelimination of extraneous metal to obtain less than 10 % sign

19、aldisturbance.3.1.1.2 DiscussionThe tester shall have a weight between50 to 104 kg (110 to 230 lb) and a height between 1.44 to 1.93m (57 to 75 in.). Should a given detector be sensitive to bodysize because of design or desired sensitivity, the physical sizeof testers should be smaller and within a

20、narrower range.3.1.1.3 DiscussionIt is recommended that the clean testerbe surveyed with a high sensitivity hand-held metal detector toensure that no metal is present.3.1.2 critical orientation, nthe orthogonal orientation of atest object that produces the smallest detection signal orweakest detecti

21、on anywhere in the detection zone; the orthogo-nal orientation of a test object that requires a higher sensitivitysetting to be detected compared to the sensitivity settingrequired to detect the object in all other orthogonal orienta-tions. See Fig. 1 for handgun orientations.3.1.2.1 DiscussionCriti

22、cal orientations are determined bytesting using a mapping procedure such as described inPractice C 1270.3.1.2.2 DiscussionThe term critical orientation can referto the worst case orthogonal orientation in a single test path orthe worst case orthogonal orientation for all the test paths (theentire de

23、tection zone). The two are coincident in the critical testpath.3.1.3 critical sensitivity setting, nthe lowest sensitivitysetting of a detector at which the critical test object in itscritical orientation is consistently detected (10 out of 10 testpasses) when passed through the detection zone on th

24、e criticaltest path.3.1.4 critical test element, nsee test element.3.1.5 critical test object, nsee test object.3.1.6 critical test path, nthe straight-line shortest-coursepath through the portal aperture, as defined by an element onthe detection sensitivity map, that produces the smallestdetection

25、signal or weakest detection for a test object in itscritical orientation. (see Figs. 2 and 3)3.1.7 detection sensitivity map, n(see Figs. 2 and 1) adepiction of the grid used to define test paths through thedetection zone, with each element of the grid containing avalue, usually the sensitivity sett

26、ing of the detector, that isindicative of the detectability of the test object.3.1.7.1 DiscussionThese values are relative and describethe detection sensitivity pattern within the detection zone forthe specific test object. The values are derived by identicallytesting each defined test path using a

27、specific test object in asingle orthogonal orientation. The value is usually the mini-mum sensitivity setting of the detector that will cause aconsistent alarm (10 out of 10 test passes) when the test object3Annual Book of ASTM Standards, Vol 15.07.FIG. 1 Six Standard Orthogonal Orientations for a H

28、andgunNOTE 1Numbers are sensitivity setting values for a hypotheticaldetector. The numbers represent the lowest sensitivity setting at which theobject was detected ten out of ten consecutive test passes through theindicated test path.NOTE 2Important: ensure that the location of the transmitter andre

29、ceiver are identified. If the detector does not have a dedicated transmitterand receiver, note the side from which testing is performed relative to theprotected area.FIG. 2 Example of Detection Sensitivity MapC 1270 97 (2003)2is passed through the detection field. Appendix X3 is a sampleform for a p

30、otential detection sensitivity map configuration.3.1.8 detection zone, nthe volume within the portal aper-ture.3.1.9 detector, nsee walk-through metal detector.3.1.10 element, nsee test element3.1.11 grid, nsee test grid3.1.11.1 grid element, n(1) a single block on a detectionsensitivity map; (2) th

31、e rectilinear volume through the detec-tion zone defined by coincident elements of identical gridworks placed on either side of the portal aperture. (see Figs. 2and 3)3.1.11.2 test path, nas defined by an element on adetection sensitivity map, a straight-line shortest-course paththrough the detectio

32、n zone of a detector undergoing mapping,detection sensitivity, or detection sensitivity verification test-ing. (see Fig. 3)3.1.12 element, test element, nfor the purpose of thistesting, a test element is the volume of space defined by theboundaries of two corresponding network openings, and itrepres

33、ents a straight-line shortest-course path through thedetection zone.3.1.12.1 DiscussionIt is necessary to define discrete andrepeatable straight-line shortest-course test paths through thedetection zone. This can be done by using two identicalnetworks (grids) made of nonconductive/nonmagnetic materi

34、alattached across the entry and exit planes of the portal apertureso the networks coincide. A test object on the end of a probecan then be passed from one side of the portal aperture to theother side through corresponding openings, which results in thetest object taking a reasonably straight-line sh

35、ortest-coursepath through the detection zone. If the networks are con-structed so that they can be put in-place identically each timethey are used, then the test paths through the detection zone arerepeatable over time. On a detection sensitivity map thecorresponding networks appear as a rectangular

36、 grid with eachelement of the grid representing a test path through thedetection zone.3.1.13 in-plant, adjinstalled in the location, position, andoperating environment where the device will be used.3.1.14 orthogonal orientation, nas used in this practice,orthogonal orientation refers to alignment of

37、 the longitudinalaxis of a test object along the xyz axes of the Cartesiancoordinate system; x is horizontal and across the portal, y isvertical, and z is in the direction of travel through the portal.(see Fig. 1 for handgun orientations)3.1.15 portal, nsee walk-through metal detector.3.1.16 test el

38、ement, n(see Figs. 2 and 3) for the purpose oftesting, it is necessary to define discrete and repeatablestraight-line shortest-course test paths through the detectionzone. This can be done by using two identical networks (grids)made of nonconductive/nonmagnetic material attached acrossthe entry and

39、exit planes of the portal aperture so the networkscoincide. A test object on the end of a probe can then be passedfrom one side of the portal aperture to the other side throughcorresponding openings, which results in the test object takinga reasonably straight-line shortest-course path through thede

40、tection zone. If the networks are constructed so that they canbe put in-place identically each time they are used, then the testpaths through the detection zone are repeatable over time.Thus, a test element is the volume of space defined by theboundaries of two corresponding network openings and itr

41、epresents a straight-line shortest-course path through thedetection zone.3.1.16.1 DiscussionOn a detection sensitivity map thecorresponding networks appear as a rectangular grid with eachelement of the grid representing a test path through thedetection zone. The element defining the critical test pa

42、th is thecritical test element.3.1.17 test grid, na network of nonconductive/nonmagnetic material, such as string or tape, can be stretchedacross the entry and exit planes of the portal aperture to definetest paths through the portal aperture; the material should notbe hygroscopic.3.1.17.1 Discussio

43、nSee Fig. 2 for an example ofa4by9element test grid.3.1.18 test object, nmetallic item meeting dimension andmaterial criteria used to evaluate detection performance.3.1.18.1 critical test objectthe one test object out of anygiven group of test objects that in its critical orientation,produces the we

44、akest detection signal anywhere in the detec-tion zone.3.1.18.2 DiscussionDepending on the particular detector,some orientation sensitive test objects may have differentlocations in the detection zone result in near critical sensitivitysettings. Hence, care must be taken in determining the criticalt

45、est object, its critical orientation, and the critical test path.3.1.18.3 shielding test object, na test object representingspecial nuclear material shielding that might be used in a theftscenario.3.1.18.4 DiscussionIt is usually a metallic container ormetallic material configured as a credible gamm

46、a-radiationFIG. 3 3-D View of Detection Zones and Test GridC 1270 97 (2003)3shield for a specific type and quantity of special nuclearmaterial. The object is specified by a regulatory authority or isbased on the facility threat analysis, or both.3.1.18.5 weapon test object, na handgun(s) or simulate

47、dhandgun designated by or satisfying the regulatory authorityrequirement for a test object.3.1.18.6 DiscussionCare must be taken when selecting ordesigning a mock handgun. Simple blocks of metal shaped likea handgun will likely not cause a metal detector to react thesame as it would to the intricate

48、 shapes and variable compo-nents of a real handgun. Most government agencies use actualguns for testing.3.1.19 walk-through metal detector (detector, portal), nafree-standing screening device, usually an arch-type portal,using an electromagnetic field within its portal structure(aperture) for detect

49、ing metallic objects, specifically weaponsor metallic shielding material, or both, on persons walkingthrough the portal.3.1.20 walk speed (Normal), nwalk speed is between 0.5to 1.3 m/s (112to 212 steps/s).3.1.20.1 DiscussionThe average casual walk rate is about134 step/s.3.1.20.2 shielding test object, nsee test object.3.1.20.3 weapon test object, nsee test object.4. Summary of Practice4.1 This practice describes a method for determining themetal detection sensitivity pattern within the aperture ofwalk-through metal detectors. It develo

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有