ASTM C1294-2007e1 Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials《带外加液体镶嵌玻璃材料的绝缘玻璃边缘密封条的通用性用标准试验方法》.pdf

上传人:李朗 文档编号:464128 上传时间:2018-11-27 格式:PDF 页数:4 大小:106.07KB
下载 相关 举报
ASTM C1294-2007e1 Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials《带外加液体镶嵌玻璃材料的绝缘玻璃边缘密封条的通用性用标准试验方法》.pdf_第1页
第1页 / 共4页
ASTM C1294-2007e1 Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials《带外加液体镶嵌玻璃材料的绝缘玻璃边缘密封条的通用性用标准试验方法》.pdf_第2页
第2页 / 共4页
ASTM C1294-2007e1 Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials《带外加液体镶嵌玻璃材料的绝缘玻璃边缘密封条的通用性用标准试验方法》.pdf_第3页
第3页 / 共4页
ASTM C1294-2007e1 Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials《带外加液体镶嵌玻璃材料的绝缘玻璃边缘密封条的通用性用标准试验方法》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: C1294 071Standard Test Method forCompatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials1This standard is issued under the fixed designation C1294; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re

2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEAdded research report information to Section 10 editorially in September 2010.1. Scope1.1 This test metho

3、d covers a laboratory procedure forquantitatively measuring the compatibility of liquid-appliedglazing materials with an insulating glass unit edge sealant.Compatibility is determined by measuring the changes in theinsulating glass edge sealant adhesive and cohesive properties.Hereinafter insulating

4、 glass is referred to as IG.1.2 This test method does not address the issue of theintegrity of the hermetic seal or changes to the vision area in anIG unit. Such factors as possible unit fogging or primarysealant reaction in a dual-seal system due to volatile compo-nents permeating the IG sealant ar

5、e not considered in this testmethod.1.3 The committee with jurisdiction over this standard is notaware of any comparable standards published by other orga-nizations.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of th

6、e user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C717 Terminology of Building Seals and SealantsC1265 Test Method for Determining the Tensile Propertiesof a

7、n Insulating Glass Edge Seal for Structural GlazingApplications3. Terminology3.1 DefinitionsRefer to Terminology C717 for definitionsof the following terms: adhesive failure, cohesive failure,compatibility, compound, elongation, glazing, seal, sealant,substrate.4. Summary of Test Method4.1 This test

8、 method includes the measurement of tensileforce, elongation, and percent cohesive or adhesive failure andobservations of the specimens general physical appearanceand observation of elongation.4.2 Test specimens are exposed to 70C (158F) heat forfour weeks while contacting the liquid-applied glazing

9、 materialbeing evaluated.4.2.1 Control specimens are exposed only to the 70C(158F) heat.4.3 Compatibility is determined by comparing the measuredand observed properties of the test specimens to the controlsamples.5. Significance and Use5.1 Liquid-applied glazing materials, bedding sealants,glazing c

10、ompounds (that is, glazing sealants) are designed toprovide a seal between the IG unit and the window or wallframing. Frequently there is physical contact between thesematerials and an IG unit edge sealant. Depending on theparticular IG unit edge sealant, there can be a detrimentalphysical or chemic

11、al interaction between it and the liquid-applied glazing material. Detrimental effects may include:weakening, softening, hardening, or adhesive failure of the IGedge sealant, or visual obstruction inside the IG unit.6. Apparatus and Accessory Materials6.1 Oven, forced draft, capable of maintaining a

12、 constanttemperature of 70 6 3C (158 6 5F).6.2 Tensile Testing Machine, capable of producing a tensileload on the specimen at the rate of 5 6 0.51 mm (0.2 6 0.02in.) per minute.1This test method is under the jurisdiction ofASTM Committee C24 on BuildingSeals and Sealants and is the direct responsibi

13、lity of Subcommittee C24.20 onGeneral Test Methods.Current edition approved Nov. 1, 2007. Published November 2007. Originallyapproved in 1995. Last previous edition approved in 2001 as C129401. DOI:10.1520/C1294-07E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AS

14、TM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2.1 Fixed MemberA fixed or

15、 essentially stationarymember carrying one grip.6.2.2 Moveable MemberA moveable member carrying asecond grip.6.2.3 GripsThe grips should be suitable to firmly graspthe test fixture that holds the test specimen and should bedesigned to eliminate eccentric specimen loading. Specimenloading should be p

16、arallel to the centerline of the short axis ofthe sealant. A swivel or universal joint near each end of thespecimen should be provided for alignment purposes.6.2.4 Grip FixtureA fixture capable of being held by thegrips and furnishing a tensile force to and maintaining properalignment with the test

17、specimen.6.3 Spatulas, for use in mixing and applying sealant.6.4 Paper Cup or Can, for use in mixing multicomponentsealants when applicable.6.5 Plastic Cartridge, (Semco), to extrude sealant whenapplicable.6.6 Triple-Beam or Electronic Balance, accurate to 60.01 g(3.5 by 104oz) for weighing multico

18、mponent sealant mixesand finished test specimens.6.7 Glass Substrates, clear float glass, 6 by 25 by 75 mm(0.25 by 1 by 3 in.).Atotal of ten substrates is required for eachglazing material tested.6.8 Spacer, nominally 13 mm (0.50 in.) wide IG, aluminumspacer with preferably an anodized aluminum surf

19、ace. Spacersshould be cut into 50-mm (2-in.) lengths.6.9 Test Fixture (Fig. 1) to hold the specimen componentsin place while the IG sealant is applied and cured.6.10 Aluminum Foil, standard kitchen wrapping foil issuitable.6.11 Container, a shallow aluminum or glass pan or tray issuitable. The conta

20、iner must be large enough to hold all the testspecimens. A container is required for each combination of IGedge sealant and liquid-applied glazing material compoundbeing tested.7. Specimen Preparation7.1 Prepare a set of five test specimen assemblies for eachIG edge sealant or liquid-applied glazing

21、 material, or both,being tested.7.2 Construction of the test specimens is done by placingthe 13 by 50-mm (0.50 by 2-in.) IG spacers into the recesses inthe test fixture. The glass substrates are installed on either sideof the spacer and the assembly is clamped together withmachine screws through the

22、 ends of the side bars. The testfixture holds the samples stationary while the IG edge sealantis applied. The IG edge sealant siteline should be approxi-mately 6 mm (0.25 in.) after the specimen is prepared.7.3 Take special care to strike off the sealant flush with theglass substrates.7.4 Cure the t

23、est specimens for a total of 7 days at 22 6 2C(72 6 2F) and 50 % relative humidity.7.5 The samples should be removed from the test fixtureafter the end of the first day of the seven-day cure period.7.6 Measure the width and length of the sealant contact areain millimetres (inches) with the glass sub

24、strates for use incalculating the tensile strength of the assembly per unit area.FIG. 1 Sample Assembly IG Compatibility TestC1294 07128. Procedure8.1 Spread the liquid-applied glazing material onto thebottom of the aluminum or glass pan to a thickness ofapproximately 6 mm (0.25 in.).8.2 Press seale

25、d edges of three of the IG edge specimensinto the liquid-applied glazing material to a depth of approxi-mately 1.6 mm (0.0625 in.).8.3 Cover the container with aluminum foil and place in theoven for four weeks at 70 6 2C (158F).8.4 Place the remaining two control specimens into anotherfoil-covered c

26、ontainer with no liquid-applied glazing materialand place in the oven for four weeks at 70 6 2C (158 6 3F).One set of control specimens are sufficient for each IG edgesealant when more than one liquid-applied glazing material isbeing tested. Do not expose more than one IG edge sealantcontrol or one

27、type of liquid-applied glazing material in asingle container.8.5 After four weeks in the oven, remove the containersfrom the oven and condition at 22 6 2C (70 6 3F) and 50 %relative humidity for a minimum of 1 h and a maximum of 24h.8.6 Following the conditioning, remove the aluminum foilfrom the to

28、p of the pan. Carefully trim the liquid-appliedglazing material from the outside face of the three testspecimens. Take care not to disturb the IG edge sealant.8.7 Further condition the specimens for a minimum of 1 hbut not more than4hat226 2C (70 6 3F) and 50 %relatively humidity.8.8 After completio

29、n of conditioning, observe the test speci-mens for softening, tackiness, adhesive failure, swelling, crack-ing, or any other observed difference in the IG edge sealantspecimens from the control specimens.8.9 After observation, pull each specimen on a tensile testmachine at a rate of 5 mm (0.2 in.) p

30、er minute. Record thetensile load in newtons (pounds-force) of the PIB peak, theelongation in millimetres (inches) at PIB peak and maximumelongation in millimetres (inches) at failure. Determine thepercent of cohesive failure. Refer to Test Method C1265 toview a typical stress strain graph of this p

31、rocedure.9. Report9.1 Observations and test results are reported on the formshown in Fig. 2.9.2 Report the following information:9.2.1 Any variation from the test method (for instance, achange in curing or conditioning cycles).FIG. 2 Compatibility Test FormC1294 07139.2.2 The actual IG edge sealant

32、minimum contact area, inmm2(in.2).9.2.3 Tensile force at the PIB peak and at ultilmate failure,in N (lbf).9.2.4 Calculate the tensile stress in pascals (lbf/in2)atfailure.9.2.5 Elongation in millimetres (inches) of movement atPIB peak and at failure. Percent elongation cannot be calcu-lated due to v

33、ariable sealant thickness in each specimen.Elongation for this test method is total sample movement priorto failure.9.2.6 The mode of failure in percent cohesive/adhesivefailure on each substrate.9.2.7 Any observation from 8.8.10. Precision and Bias310.1 A statistical analysis made from the results

34、obtainedfrom a round-robin test of the tensile properties in which eachof four laboratories tested two glazing sealants and two IGedge sealants in accordance with the prescribed test for theeffect of the glazing sealant on the edge sealant resulted in thefollowing:10.1.1 The repeatability (within a

35、given laboratory) intervalfor two materials tested by four laboratories is 34.63 N (7.79lb). In future use of this test method, the difference betweentwo test results obtained in the same laboratory on the samematerial will be expected to exceed 34.63 N only about 5 % ofthe time.10.1.2 The reproduci

36、bility (between given laboratories) twomaterials tested by four laboratories is 103.9 N (23.4 lb). Infuture use of this test method, the difference between two testresults obtained in a different laboratory on the same materialwill be expected to exceed 103.9 N only about 5 % of the time.11. Keyword

37、s11.1 bedding sealant; compatibility; glazing sealant; insu-lating glass; sealant.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the v

38、alidity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your c

39、omments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments ha

40、ve not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multipl

41、e copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).3Supporting data have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR:D24-1049C1294 0714

展开阅读全文
相关资源
猜你喜欢
  • BS PD ISO IEC TR 38504-2016 Governance of information technology Guidance for principles-based standards in the governance of information technology《信息技术管理 信息技术管理的原则导向标准指南》.pdf BS PD ISO IEC TR 38504-2016 Governance of information technology Guidance for principles-based standards in the governance of information technology《信息技术管理 信息技术管理的原则导向标准指南》.pdf
  • BS PD ISO IEC TS 18508-2015 Information technology Additional Parallel Features in Fortran《信息技术 用Fortran的附加并行特征》.pdf BS PD ISO IEC TS 18508-2015 Information technology Additional Parallel Features in Fortran《信息技术 用Fortran的附加并行特征》.pdf
  • BS PD ISO IEC TS 18822-2015 Programming languages C++ File System Technical Specification《编程语言 C++ 文件系统技术规格》.pdf BS PD ISO IEC TS 18822-2015 Programming languages C++ File System Technical Specification《编程语言 C++ 文件系统技术规格》.pdf
  • BS PD ISO IEC TS 19568-2017 Programming languages C++ extensions for library fundamentals《编程语言 库原理的C++扩展》.pdf BS PD ISO IEC TS 19568-2017 Programming languages C++ extensions for library fundamentals《编程语言 库原理的C++扩展》.pdf
  • BS PD ISO IEC TS 19570-2015 Programming Languages Technical Specification for C++ Extensions for Parallelism《编程语言 用于平行的C++扩展的技术规格》.pdf BS PD ISO IEC TS 19570-2015 Programming Languages Technical Specification for C++ Extensions for Parallelism《编程语言 用于平行的C++扩展的技术规格》.pdf
  • BS PD ISO IEC TS 19571-2016 Programming Languages Technical Specification for C++ Extensions for Concurrency《编程语言 并发性C++扩展技术规格》.pdf BS PD ISO IEC TS 19571-2016 Programming Languages Technical Specification for C++ Extensions for Concurrency《编程语言 并发性C++扩展技术规格》.pdf
  • BS PD ISO IEC TS 19763-13-2016 Information technology Metamodel framework for interoperability (MFI) Metamodel for form design registration《信息技术 互操作性元模型框架(MFI) 形式设计注册元模型》.pdf BS PD ISO IEC TS 19763-13-2016 Information technology Metamodel framework for interoperability (MFI) Metamodel for form design registration《信息技术 互操作性元模型框架(MFI) 形式设计注册元模型》.pdf
  • BS PD ISO IEC TS 19841-2015 Technical Specification for C++ Extensions for Transactional Memory《用于事务存储的C++扩展的技术规格》.pdf BS PD ISO IEC TS 19841-2015 Technical Specification for C++ Extensions for Transactional Memory《用于事务存储的C++扩展的技术规格》.pdf
  • BS PD ISO IEC TS 20027-2015 Biometrics interoperability profiles Best practices for slap tenprint captures《生物计量互操作性配置文件 掌击十指指纹获取用最优实践范例》.pdf BS PD ISO IEC TS 20027-2015 Biometrics interoperability profiles Best practices for slap tenprint captures《生物计量互操作性配置文件 掌击十指指纹获取用最优实践范例》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1