1、Designation: C1560 03 (Reapproved 2016)Standard Test Method forHot Water Accelerated Aging of Glass-Fiber ReinforcedCement-Based Composites1This standard is issued under the fixed designation C1560; the number immediately following the designation indicates the year oforiginal adoption or, in the ca

2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method provides a way of accelerating theaging of glass fiber reinforced cementi

3、tious composites inorder to develop data that will indicate real-life naturalweathering performance.1.2 The coupons prepared for this test method will be testedusing Test Method C947.1.3 This test method can be used to age coupons for othertest methods.1.4 The values stated in inch-pound units are t

4、o be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of

5、 the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C947 Test Method for Flexural Properties of Thin-SectionGlass-Fiber-Reinforced Concrete (Using Simple Be

6、amWith Third-Point Loading)C1228 Practice for Preparing Coupons for Flexural andWashout Tests on Glass Fiber Reinforced Concrete3. Significance and Use3.1 The basis for this test as an indicator of the long termbehavior of fiber reinforced composites is that elevated tem-perature and moisture conten

7、t accelerate the formation of theproducts of hydration of the cement in the matrix, particularlycalcium hydroxide.3.1.1 It is known that the interaction of these products ofhydration, particularly calcium hydroxide, with the fibers canhave a major effect on the long-term properties of the compos-ite

8、s.3.1.2 The principal mechanism that occurs is that thecalcium hydroxide forms within the bundles of filaments thatform the glass fiber strand. This gradually bonds the filamentstogether, which reduces filament pull-out. This causes a reduc-tion in the strain capacity of the composite, thereby reduc

9、ingthe strength of the composite and changing the composite froma ductile material to an increasingly brittle material.3.1.3 Accelerating the formation of the hydration productsaccelerates their interaction with the fibers, hence acceleratingthe aging of the composite.3.2 The data developed from thi

10、s test are used by research-ers and manufacturers to evaluate the long-term performanceof different mixtures, reinforcements, mixture components, andto provide data for the development of design procedures forproducts made from these composites.3.2.1 The recorded data also provides screening informa

11、tionas new matrices and reinforcements are developed.3.3 The usefulness of the test as an indicator of long termcomposite performance is valid if the only reactions that areaccelerated are those that occur more slowly under naturalweathering, hot water can induce effects in some composites,for insta

12、nce those containing acrylic polymer, that may notoccur in natural weathering. This test method may not be avalid indicator of long-term performance of such composites.4. Apparatus4.1 Aging TanksTank material can be but not limited to,plastic, insulated to maintain a stable temperature. Insulationsh

13、ould cover all exterior surfaces including the cover. Insula-tion can be a foam product as used in building construction.4.1.1 The size of the tank is typically 12 in. deep (300 mm),18 in. wide (450 mm), and 20 to 36 in. (600 to 900 mm), inlength. Size is determined by the amount of coupons to bepro

14、cessed and the ability to maintain stable temperatures.1This test method is under the jurisdiction of ASTM Committee C27 on PrecastConcrete Products and is the direct responsibility of Subcommittee C27.40 on GlassFiber Reinforced Concrete.Current edition approved April 1, 2016. Published May 2016. O

15、riginallyapproved in 2003. Last previous edition approved in 2009 as C1560 03(2009).DOI: 10.1520/C1560-03R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the sta

16、ndards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1Water temperature in several medium sized tanks is easier tocontrol than one large tank.4.2 Heating UnitAn immersion unit with rheostat fo

17、rcontrolling temperature, such as those used for aquariums, hasbeen found to be satisfactory.4.3 ThermometerA standard immersion, laboratory ther-mometer is used to monitor temperature. More sophisticatedrecorders can also be used.4.4 Immersion RackA rack built from a non-contaminating material, suc

18、h as wood or plastic, should beused to maintain coupon separation. Space should be at least 1in. (25 mm) between coupons and coupons should be totallyimmersed. The design of the rack is left up to the testingfacility.4.5 It is recommended that about 50 in.3(820 cc) of waterbe used per coupon.4.6 The

19、 tank should be sealed to prevent loss of waterthrough evaporation.5. Procedure5.1 Coupons are prepared according to Practice C1228,orcut from actual product, and coded for identification. Couponsare first cured for 28 days and tested using Test Method C947.A random sampling of test coupons is teste

20、d to establishunaged or beginning properties. Sufficient coupons should beproduced to allow the testing of a minimum of six coupons perinterval.5.1.1 Coupons cut from actual product should have aproduct history if possible.5.2 Coupons are totally immersed in the tank filled withpreheated water. The

21、type of water, for example. distilled,lime-saturated, etc., must be chosen to minimize contaminationof the coupons and to minimize the possibility of the waterdissolving constituents of the composite that could affect theaging process.5.2.1 Different matrices should be aged in separate tanks.5.2.2 I

22、t is important that the water not be changed during theduration of the test. Also topping up should be minimal.5.3 Test intervals after immersion are: 0, 5, 10, 20, 30, 40,50, 60, 70, 80, 90 or more days. Aging can be considered ascomplete when the doubling of the aging period shows lessthan a 5 % d

23、ecrease in the flexural ultimate and/or a decreaseof strain capacity of less than 10 %.5.4 Water temperature can be 122F (50C) up to 176F(80C) but must be stable at the chosen temperature.Aging willbe faster at higher temperatures. Temperature should be main-tained at the required level 6 3F (2C) an

24、d measured andrecorded at twelve hour intervals. Manual checks with alaboratory thermometer is satisfactory, however the use of acontinuous recorder is preferred. If the temperature increasesor decreases more than 3F (2C) from the chosen value and isconstant for over five hours the test should be di

25、scontinued. Ifthere is any question regarding the stability of the temperaturethe test should be discontinued.5.5 At each test interval, aged coupons should be selected atrandom from the remaining coupons in the tank and tested.6. Calculation or Interpretation of Results6.1 Modulus of Rupture is cal

26、culated in accordance withTest Method C947.6.2 Strain to failure is measured analogously using themeasured deflection at failure.7. Report7.1 The report shall include the following:7.1.1 Identification of coupon,7.1.2 Description of coupon,7.1.3 Temperature of water,7.1.4 Number of hours immersed,7.

27、1.5 Date and time of test,7.1.6 Type of test performed,7.1.7 Flexural yield strength and flexural ultimate strengthas per Test Method C947,7.1.8 Measured deflection at failure,7.1.9 Appearance of coupon at rupture point,7.1.10 Description of reinforcement,7.1.11 Description of mix proportions includ

28、ing fibercontent,7.1.12 Type of aging medium, for example, distilled water,lime saturated water, etc., and7.1.13 Source of coupons.8. Precision and Bias8.1 The precision and bias criteria are being developed andtests are being conducted.9. Keywords9.1 accelerated aging; GFRC; glass fiber; glass fibe

29、r rein-forced concreteASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringeme

30、nt of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or

31、for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views kno

32、wn to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting AST

33、M at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 03 (2016)2

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1