1、Designation: C 181 03Standard Test Method forWorkability Index of Fireclay and High-Alumina PlasticRefractories1This standard is issued under the fixed designation C 181; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of

2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the work-ability index of fireclay and high-alumina plastic refractories

3、by measuring the plastic deformation of a molded test speci-men when subjected to impacts.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practic

4、es and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 2906 Practice for Statements on Precision and Bias forTextiles3. Significance and Use3.1 Workability index serves as a measure of the facilitywith which plastic refractory material

5、s can be rammed,gunned, or vibrated into place.3.2 Workability index is commonly used to control consis-tency of plastics during manufacture. It has also been founduseful for specification acceptance by the consumer.3.3 The workability index determination can provide infor-mation for developing a pl

6、astic body. When a sample splitsunder impact at various water contents, it is an indication thatthe material is “short” or lacking in plasticity.3.4 Determinations on samples that split during impact willbe difficult to reproduce. If the sample splits, the measurementis not a true indication of defo

7、rmation. This should be noted inthe report.4. Apparatus4.1 RammerThe apparatus shall consist of the deviceknown as the rammer for refractories3(see Fig. 1). It shallconsist essentially of a steel cylindrical mold 2.00 in. (50.8mm) in inside diameter and 4.75 in. (120.6 mm) in length,supported in a v

8、ertical position on the same axis as a shaft towhich shall be fastened a plunger that fits inside the mold.A 14-lb (6.4-kg) cylindrical weight slides on the same shaftand is arranged to fall a distance of 2 in. (51 mm) beforeengaging a collar fastened to the shaft. As shown in Fig. 1, theweight may

9、be raised by a manually rotated cam. Provisionshall be made to support the weight, thereby removing the loadfrom the vertical shaft by the installation of two hooks (havinga 10-32 screw thread) in the top side of the weight in a positionthat enables them to engage with pins (having an 8-32 screwthre

10、ad) placed on each side of the upper portion of theframework, as shown in Fig. 1 and in detail in Fig. 2. A steelrule,4one edge graduated in 0.02-in. (0.5-mm) increments,shall be attached (Note 1) to the rammer so that the position ofthe end of the vertical shaft can be read. The portion of the rule

11、to be used shall be adjusted so that when the vertical shaft is inthe lowest position, its machined end is in alignment with thegraduation on the rule that represents the exact distance1This test method is under the jurisdiction of ASTM Committee C08 onRefractories and is the direct responsibility o

12、f Subcommittee C08.09 on MonolithicRefractories.Current edition approved November 1, 2003. Published January 2004. Originallyapproved in 1943. Last previous edition approved in 1997 as C 181 91 (1997) e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Se

13、rvice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The rammer for refractories, Model 315-R, is available from Dietert FoundryTesting Equipment, 9190 Roselawn Ave, Detroit, MI 48204. Accessory partsrequired

14、for conduct of this test and calibration of the rammer include:Test Equipment Part NumberSpecimen tube 315-9Cup pedestal 315-111.000 in. cup pedestal spacer block 315R-8Stripping post 315-14Specimen tube conditioner 315-30Replacement swab for 315-30 315-02006Liquid parting pattern spray 315-02007Cal

15、ibration Equipment Part NumberRammer foundation tester (includes impact rings,micrometer, and test anvil)307Replacement impact rings 307-3AMaster precision specimen tube 315-184A suitable rule is the Lufkin Rule Co. Rule No. 2103-R, which is 6 in. (152mm) in length and must be cut off at each end so

16、 that the desired portion of thegraduations aligns with the shaft.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.between the top and bottom of the bottom plate of the mold(approximately 1.7 in. (43 mm). The upper end of the scalemay

17、 be cut off flush with the top of the rod (see Note 1), whichprovides a rule of sufficient length for measuring the maximumdistance obtainable between the ends of the mold (Note 2).NOTE 1One method of mounting the rule is to install in a verticalposition a38-in. (9.5-mm) square rod, 418 in. (105 mm)

18、 in length, in thatpart of the framework which constitutes the top bearing for the shaft. Oneend of the rod is reduced to a14-in. (6.4-mm) round section for a lengthof38 in., and this is threaded for a14-20 screw. A tapped hole, to receivethe threaded rod, is made in the framework and on the center

19、line (fromfront to back) of the apparatus. When tightening the rod in place, one facemust be in a position so that the rule can be sweat-soldered to it as shownin Fig. 2.NOTE 2The apparatus as described in this section is capable ofmeasuring workabilities up to about 32 %. For products of higherwork

20、ability a suitable spacer block5may be installed under the specimen.4.1.1 Mounting for RammerThe rammer shall bemounted on a 27-in. (686-mm) high concrete column, having abase measuring at least 8 by 11 in. (200 by 279 mm). Four14-in. (6.4-mm) bolts, at least 3 in. (76 mm) in length, shall becast in

21、 the top of the column and shall be grouted with asuitable mortar. Variable results are obtained from the testunless the described mounting or an acceptable alternativemounting6is used for the rammer.4.1.2 Maintenance and CalibrationAs needed, dependingon use, clean all moving parts and lubricate wi

22、th SAE 10 oil.Make periodic checks of the height that the weight drops toinsure the weight is being raised 2 in. (51 mm). Inspect therammer to determine whether it and the foundation areproducing full ramming energy. This is accomplished by usingcalibrated impact rings.7NOTE 3Variation in the smooth

23、ness and dimensions of the specimentube may cause variation in workability values. For referee testing thespecimen tube may require periodic comparison with a master precisionspecimen tube.85. Test Specimens5.1 Temperature of Plastic Refractory Since the work-ability index may vary with a wide sprea

24、d of temperature, thetemperature of the material to be tested must be between 65and 75F (18 and 24C) to reduce this variable. Recordtemperature of material before forming the cylinder.NOTE 4As much as a 3-point change in the workability index mayoccur within the 10F (6C) stated range.5.2 Number of S

25、pecimensFive cylindrical test specimensshall be molded from the sample (Note ) of plastic refractory.5.3 Molding of SpecimensThe interior of the mold shallbe cleaned and coated with a light film of suitable partingagent9prior to the preparation of each specimen. To facilitate5A suitable 1-in. (25-mm

26、) spacer block is listed in footnote 4.6An acceptable alternative mounting is available from Dietert Foundry TestingEquipment; use the rammer base, part no. 315-27, and the rammer pedestal, part no.315-45.7Part number 307 as provided by Dietert Foundry Testing Equipment, consistsof a set of precisio

27、n steel rings, a steel anvil and a micrometer, has been foundsuitable for this purpose. To determine full ramming energy, the anvil is positionedin the specimen tube locating hole in the base of the rammer. A test ring is thenplaced in the center of the anvil with the axis of the ring being horizont

28、al. The ringis then subjected to 3 impacts of the rammer head. A measurement across the centerof the deformed ring is then made and compared to the limits specified on the boxcontaining the rings. Detailed instructions are included in the calibration kit.8Part number 315-18 as provided by Dietert Fo

29、undry Testing Equipment, hasbeen found suitable for this purpose.9A suitable parting agent is provided by Dietert Foundry Testing Equipment, asdescribed in footnote 4.FIG. 1 Apparatus for Workability-Index TestFIG. 2 Upper Portion of the Sand Rammer Showing Close-Up ofModifications RequiredC181032fi

30、lling the mold, the sample shall be broken into pieces varyingin size, the largest dimension being about 1 in. (25 mm). Thesample weight shall be chosen to provide a sample height of2.5 6 0.1 in. (64 6 3 mm). For a super-duty plastic, the sampleweight is approximately 300 g; for an 85 to 90 % alumin

31、aplastic, approximately 375 g. After placing the material in themold, it shall be subjected to ten impacts by turning the handle,which causes the weight to be raised 2 in. (51 mm) and thendropped upon the collar attached to the plunger shaft. The moldcontaining the sample shall then be upended and a

32、n additionalten impacts given to the specimen. The formed test specimenshall then be extruded from the mold by the use of a suitableauxiliary plunger.6. Procedure6.1 Remove the load on the plunger of the mold bysuspending the weight from the framework. Do this by slightlyrotating the weight while en

33、gaging the hooks on the pins in theframework. After raising the vertical shaft, place the testspecimen on the bottom of the mold and lower the shaft untilthe plunger is in firm contact with the specimen. Obtain thelength of the specimen to the nearest 0.02 in. (0.5 mm) bysighting on the rule and the

34、 end of the shaft. Disengage theweight from its support and carefully lower it until it is at restin its normal position. Then apply three impacts from theweight to the test specimen. Read the final length of thespecimen from the scale, and record the difference in inches ormillimetres between the t

35、wo measurements.7. Calculation and Report7.1 Calculate the percentage deformation for each of thefive test specimens on the basis of the original length and reportthe average value as the workability index. The workabilityindex shall be calculated by the following equation, and shallbe rounded off t

36、o one decimal place.W 5L 2 L1L3 100whereL = length of specimen prior to deformation,L1= length of specimen after deformation, andW = workability index.7.2 State the temperature of the sample, the specimenweight used, and whether any test specimen crumbled as aresult of the three impacts.8. Precision

37、 and Bias8.1 Interlaboratory Test Data10An interlaboratory testwas run in 1975, in which two laboratories each tested tenspecimens from each of two plastic materials: a super-duty anda high-alumina phosphate-bonded plastic. Samples were se-lected from the same container of plastic and tested in each

38、laboratory at the same time. The components of variance forworkability index results calculated by the procedures given inPractice D 2906 are as follows:Within-laboratory component 4.1 % of the averageBetween-laboratory component 5.1 % of the average8.2 PrecisionFor the components of variance given

39、in 8.1,two averages of test values should be considered significantlydifferent at the 95 % probability level if the difference equals orexceeds the critical difference listed as follows (for t = 1.96):Critical Difference, % of Grand Average ofWorkability IndexNumber of Samples inEach AverageWithin-L

40、aboratoryPrecisionBetween-LaboratoryPrecision3 6.6 15.65 5.1 15.010 3.6 14.615 2.9 14.38.3 BiasNo justifiable statement on bias is possible sincethe true value of the workability index cannot be established byan accepted reference material.9. Keywords9.1 refractories; refractory plastic; workability

41、ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are

42、 entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standar

43、dsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committ

44、ee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).10Supporting data are available from ASTM International Headquarters. RequestRR: C 08 1003.C181033