1、Designation: C 185 02American Association StateHighway and Transportation Officials StandardAASHTO No.: T137Standard Test Method forAir Content of Hydraulic Cement Mortar1This standard is issued under the fixed designation C 185; the number immediately following the designation indicates the year of
2、original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department
3、of Defense.1. Scope1.1 This test method covers the determination of the aircontent of hydraulic cement mortar under the conditionshereinafter specified.1.2 The values stated in SI units are to be regarded as thestandard.1.3 Values in SI shall be obtained by measurement in SIunits or by appropriate c
4、onversion, using the Rules for Con-version and Rounding in IEEE/ASTM SI 10, of measurementsmade in other units.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safe
5、ty and health practices and determine the applica-bility of regulatory limitations prior to use.1.5 Warning Fresh hydraulic cementitious mixtures arecaustic and may cause chemical burns to skin and tissue uponprolonged exposure.22. Referenced Documents2.1 ASTM Standards:C 91 Specification for Masonr
6、y Cement3C 109/C 109M Test Method for Compressive Strength ofHydraulic-Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)3C 150 Specification for Portland Cement3C 183 Practice for Sampling and the Amount of Testing ofHydraulic Cement3C 230/C 230M Specification for Flow Table for Use in Testsof Hyd
7、raulic Cement3C 305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic Consistency3C 511 Specification for Moist Cabinets, Moist Rooms, andWater Storage Tanks Used in the Testing of HydraulicCements and Concretes3C 595 Specification for Blended Hydraulic Cements3C 778 Sp
8、ecification for Standard Sand3C 1005 Specification for Weights and Weighing Devices forUse in the Physical Testing of Hydraulic Cements3C 1157 Performance Specification for Hydraulic Cement3C 1328 Specification for Plastic Stucco Cement3C 1328 Specification for Mortar Cement3E 438 Specification for
9、Glasses in Laboratory Apparatus4E 694 Specification for Laboratory Glass Volumetric Appa-ratus4IEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): The Modern Metric System43. Summary of Test Method3.1 Prepare a mortar with standard sand and the cement tobe tested, using a wate
10、r content sufficient to give a requiredflow. Compact the mortar into a measure of known volume anddetermine mass. Calculate the air content from the measureddensity of the mortar, the known densities of the constituents,and the mixture proportions.4. Significance and Use4.1 The purpose of this test
11、method is to determine whetheror not the hydraulic cement under test meets the air-entrainingor non-air-entraining requirements of the applicable hydrauliccement specification for which the test is being made. The aircontent of concrete is influenced by many factors other than thepotential of the ce
12、ment for air entrainment.5. Apparatus5.1 Flow Table, Flow Mold, and Caliper, shall conform toSpecification C 230/C 230M.5.2 MeasureA cylindrical measure having an inside di-ameter of 76 6 2 mm and a depth (approximately 88 mm)adjusted by standardization with water to contain 400 6 1mLat 23.0 6 2.0C
13、(Note 1). For the purposes of this test, thecapacity of the measure in millilitres is the mass of the watercontent of the measure, in grams, divided by 0.9976, nocorrection in mass being made for the buoyant effect of air. Themeasure shall have a uniform wall thickness. The thickness ofthe wall and
14、bottom shall not be less than 2.9 mm. The totalmass of the empty measure shall not be more than 900 g. The1This test method is under the jurisdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.21 on Air Entrainment.Current edition approved Aug. 10, 2002. Publ
15、ished September 2002. Originallypublished as C 185 44 T. Last previous edition C 185 01.2Refer to the section on Safety Precautions, “Manual of Cement Testing,”Annual Book of ASTM Standards, Vol 04.01.3Annual Book of ASTM Standards, Vol 04.01.4Annual Book of ASTM Standards, Vol 14.04.1Copyright ASTM
16、 International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.measure shall be made of a metal not attacked by the cementmortar.NOTE 1Calibrate the 400-mL measure by filling with distilled waterat 23.06 2.0C to a point where the meniscus extends appreciably abov
17、ethe top of the measure, placing a clean piece of plate glass on the top ofthe measure, and allowing the excess water to be squeezed out. Theabsence of air bubbles as seen through the glass ensures that the measureis completely full. Care shall be taken that the excess water is wiped fromthe sides o
18、f the container before weighing.5.3 Mixer, Bowl, and Paddle, shall conform to the apparatussection of Practice C 305.5.4 StraightedgeA steel straightedge not less than 200mm long and not less than 1.5 mm nor more than 3.5 mm inthickness.5.5 Weights and Weighing Devices, shall conform to Speci-ficati
19、on C 1005. Evaluate the weighing device for precisionand accuracy at a total load of 2 kg.5.6 Glass GraduatesGlass graduates of 250-mL capacity,conforming to the requirements of Specifications E 438 andE 694.5.7 Tamper, conforming to the requirements of Test MethodC 109/C 109M. The tamping face of t
20、he tamper shall be flatand at right angles to the length of the tamper.5.8 Tapping Stick, a piece of hard wood having a diameterof approximately 16 mm and a length of approximately 152mm.5.9 SpoonA metal restaurant-type serving spoon not lessthan 230 mm in length and with a bowl approximately 100 mm
21、in length.6. Temperature and Humidity6.1 Maintain the temperature of the room and dry materialsat 23.0 6 4.0 C.6.2 Condition the mixing water and the measure, if it isbeing calibrated at 23 6 2C.6.3 Maintain the relative humidity of the laboratory at notless than 50 %.7. Standard Sand7.1 Use sand co
22、nforming to the requirements of Specifica-tion C 778 for 2030 sand.8. Sampling8.1 Sample the cement in accordance with Practice C 183.9. Procedure9.1 BatchProportion the standard mortar using 350 gcement to 1400 g 2030 standard sand and sufficient water togive a flow of 8712 6 712 % when determined
23、in accordancewith 9.3.NOTE 2Test Method C 185 refers to hydraulic cements that complyunder Specification C 150, Specification C 595, and Performance Speci-fication C 1157. Masonry cements (see Specification C 91), mortar ce-ments (see Specification C 1329), and plastic cements (see SpecificationC 13
24、28) require different sand, mass, and flow. Refer to the applicablespecification.9.2 Mixing of MortarMix the mortar in accordance withPractice C 305.9.3 Flow DeterminationCarefully wipe dry the flow-tabletop and place the flow mold at the center of it. Using the spoon,place a layer of mortar about 2
25、5 mm in thickness in the moldand tamp 20 times with the tamper. The tamping pressure shallbe just sufficient to ensure uniform filling of the mold. Overfillthe top of the mold approximately 20 mm with mortar andtamp as specified for the first layer. Then cut off the mortar toa plane surface, flush w
26、ith the top of the mold, by drawing thestraightedge with a sawing motion across the top of the mold.Wipe the flow table top clean and dry, being especially carefulto remove any water from around the edge of the mold. Lift themold away from the mortar 1 min after completing the mixingoperation. Immed
27、iately drop the table 10 times in accordancewith Specification C 230/C 230M. The flow is the resultingincrease in average diameter of the mortar mass, as determinedwith the calipers, measured on at least four diameters atapproximately equispaced intervals, expressed as a percentageof the original di
28、ameter. Make trial mortars with varyingpercentages of water until the specified flow is obtained. Makeeach trial with fresh mortar.9.4 Mass per 400 mL of MortarWhen the quantity ofmixing water has been found that produces a flow of 8712 6712 %, immediately determine the mass per 400 mL of mortar,usi
29、ng the mortar remaining in the mixing bowl after the flowhas been determined. In the determination of the mass per 400mL, do not use the portion of the mortar used in the flowdetermination. Using the spoon, place the mortar gently intothe 400ml measure in three equal layers. Tamp each layer 20times
30、around the inner surface of the measure. For the finallayer of mortar, overfill the 400ml measure approximately 20mm. The position of the tamper shall be that: the broad side ofthe tamper is parallel to the radius and is perpendicular to theinner surface of the measure. Each layer is tamped in oneco
31、mplete revolution (rotation) with only sufficient pressure toadequately fill the measure and eliminate voids within themortar. After the measure has been filled and tamped in theabove prescribed manner, tap the sides of the measure lightlywith the side of the tapping stick, one each at five differen
32、tpoints at approximately equal spacing around the outside of themeasure, in order to preclude entrapment of extraneous air(Note 3). No obvious space shall be left between the mortarand the inner surface of the measure as a result of the tampingoperation. Then cut the mortar off to a plane surface, f
33、lush withthe top of the measure, by drawing the straightedge with asawing motion across the top of the measure, making twopasses over the entire surface, the second pass being made atright angles to the first. If, in the striking-off operation, loosesand grains cause the straightedge to ride above t
34、he top surfaceof the measure, these grains shall be removed, and theoperation repeated. Complete the entire operation of filling andstriking off the measure within 112 min. Wipe off all mortar andwater adhering to the outside of the measure. Determine themass of the measure and its contents. Subtrac
35、t the mass of thecontainer, and record the mass of the mortar in grams.NOTE 3This operation may be facilitated by placing the measure ona steady flat-surfaced support of lesser diameter than the measure whilefilling and wiping.10. Calculation10.1 Calculate the air content of the mortar from theC1850
36、22following formula which is based on the batch proportionsgiven in 9.1, taking the specific gravity of portland cement as3.15 and of 2030 standard sand as 2.65. When the hydrauliccement is other than portland, the appropriate value for itsspecific gravity shall be substituted for the value of 3.15
37、andthe formula rederived accordingly:Air content, volume % 5 100 2 W182.7 1 P!/2000 1 4P!# (1)where:W = mass of 400 mL of mortar, g, andP = percentage of mixing water, based on mass of cementused.NOTE 4This formula is derived as follows:Air content, volume % 5 1001 2 Wa/Wc!# (2)where:Wa= actual mass
38、 per unit of volume as determined by thistest method.= W/400 g/mL, where W is the mass in grams of thespecified 400 mL of mortar (9.4),Wc= theoretical mass per unit of volume, calculated on anair-free basis as follows and using the values forquantities of materials and specific gravities as givenin
39、9.1 and 10.1,= 350 1 1400 1 350 3 P 3 0.013503.15114002.651350 3 P 3 0.011= 5 1 0.01P!1.827 1 0.01P!, andP = percentage of mixing water, based on mass of ce-ment.Substituting for Waand Wcwe have:Air content, volume % 5 100S1 2W40031.827 1 0.01P5 1 0.01PDAir content, volume % 5 100 2W431.827 1 0.01P!
40、5 1 0.01P!Air content, volume % 5 100 2 2.5W182.7 1 P!5000 1 10P!Air content, volume % 5 100 2 W182.7 1 P!2000 1 4P!10.2 Make only one determination of air content on a batch.NOTE 5Difficulty has occasionally been experienced with this testmethod by some persons. These difficulties usually have take
41、n the form ofvalues for air content that are abnormally high and that may be greaterthan the specified maxima in specifications for hydraulic cement. Theair-entraining potential of the sand may be reduced by washing in thelaboratory with potable water by decantation until a clear, colorlesssupernata
42、nt liquid is obtained. In case of dispute, such freshly washedsand shall be used.11. Report11.1 When this test method is used for specific action incompliance testing, report the value for the air content to thenearest 1 %.12. Precision and Bias12.1 The single-operator, within-laboratory, standard d
43、evia-tion has been found to be 0.56 % air content throughout therange of 8 to 19 % air. Therefore, results of two properlyconducted tests by the same operator on similar batches shouldnot differ by more than 1.6 % air.12.2 The multilaboratory standard deviation has been foundto be 1.0 % air content
44、throughout the range from 8 to 19 % air.Therefore, results of two different laboratories on similarbatches should not differ from each other by more than 2.8 %air.13. Keywords13.1 air content; hydraulic cement mortarFor additional useful information on details of cement tests methods, references may
45、 be made to the “Manual ofCement Testing,” which appears in the Annual Book of ASTM Standards, Vol 04.01.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that
46、 determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapprov
47、ed or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you fee
48、l that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).C185023