ASTM C192 C192M-2014 Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory《实验室中制造和养护混凝土的试验样品的标准实施规程》.pdf

上传人:registerpick115 文档编号:465972 上传时间:2018-11-27 格式:PDF 页数:9 大小:101.21KB
下载 相关 举报
ASTM C192 C192M-2014 Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory《实验室中制造和养护混凝土的试验样品的标准实施规程》.pdf_第1页
第1页 / 共9页
ASTM C192 C192M-2014 Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory《实验室中制造和养护混凝土的试验样品的标准实施规程》.pdf_第2页
第2页 / 共9页
ASTM C192 C192M-2014 Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory《实验室中制造和养护混凝土的试验样品的标准实施规程》.pdf_第3页
第3页 / 共9页
ASTM C192 C192M-2014 Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory《实验室中制造和养护混凝土的试验样品的标准实施规程》.pdf_第4页
第4页 / 共9页
ASTM C192 C192M-2014 Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory《实验室中制造和养护混凝土的试验样品的标准实施规程》.pdf_第5页
第5页 / 共9页
亲,该文档总共9页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: C192/C192M 13aC192/C192M 14Standard Practice forMaking and Curing Concrete Test Specimens in theLaboratory1This standard is issued under the fixed designation C192/C192M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision,

2、 the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This practice cove

3、rs procedures for making and curing test specimens of concrete in the laboratory under accurate controlof materials and test conditions using concrete that can be consolidated by rodding or vibration as described herein.1.2 The values stated in either SI units or inch-pound units are to be regarded

4、separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety

5、concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. (WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical

6、 burns to exposedskin and tissue upon prolonged exposure.WarningFresh hydraulic cementitious mixtures are caustic and may cause chemicalburns to exposed skin and tissue upon prolonged exposure.2)2. Referenced Documents2.1 ASTM Standards:3C70 Test Method for Surface Moisture in Fine AggregateC125 Ter

7、minology Relating to Concrete and Concrete AggregatesC127 Test Method for Density, Relative Density (Specific Gravity), and Absorption of Coarse AggregateC128 Test Method for Density, Relative Density (Specific Gravity), and Absorption of Fine AggregateC138/C138M Test Method for Density (Unit Weight

8、), Yield, and Air Content (Gravimetric) of ConcreteC143/C143M Test Method for Slump of Hydraulic-Cement ConcreteC172/C172M Practice for Sampling Freshly Mixed ConcreteC173/C173M Test Method for Air Content of Freshly Mixed Concrete by the Volumetric MethodC231/C231M Test Method for Air Content of Fr

9、eshly Mixed Concrete by the Pressure MethodC330/C330M Specification for Lightweight Aggregates for Structural ConcreteC403/C403M Test Method for Time of Setting of Concrete Mixtures by Penetration ResistanceC470/C470M Specification for Molds for Forming Concrete Test Cylinders VerticallyC494/C494M S

10、pecification for Chemical Admixtures for ConcreteC511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of HydraulicCements and ConcretesC566 Test Method for Total Evaporable Moisture Content of Aggregate by DryingC617/C617M Practice for Capping

11、 Cylindrical Concrete SpecimensC1064/C1064M Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteC1077 Practice forAgencies Testing Concrete and ConcreteAggregates for Use in Construction and Criteria for TestingAgencyEvaluation1 This practice is under the jurisdiction ofASTM Commit

12、tee C09 on Concrete and ConcreteAggregates and is the direct responsibility of Subcommittee C09.61 on Testingfor Strength.Current edition approved Oct. 1, 2013Aug. 1, 2014. Published October 2013August 2014. Originally approved in 1944. Last previous edition approved in 2013 asC192/C192M 13.C192/C19

13、2M 13a. DOI: 10.1520/C0192_C0192M-13a.10.1520/C0192_C0192M-14.2 See section on Safety Precautions, Manual of Aggregate and Concrete Testing,Annual Book of ASTM Standards, Vol.Vol 04.02.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm

14、.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because

15、it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears

16、at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.2 American Concrete Institute Publications:4211.3 Practice for Selecting Proportions for No-Slump Concrete309R Guide for Consolidation of Concrete3. Signific

17、ance and Use3.1 This practice provides standardized requirements for preparation of materials, mixing concrete, and making and curingconcrete test specimens under laboratory conditions.3.2 If specimen preparation is controlled as stipulated herein, the specimens may be used to develop information fo

18、r thefollowing purposes:3.2.1 Mixture proportioning for project concrete,3.2.2 Evaluation of different mixtures and materials,3.2.3 Correlation with nondestructive tests, and3.2.4 Providing specimens for research purposes.NOTE 1The concrete test results for concrete specimens made and cured using th

19、is practice are widely used. They may be the basis for acceptancetesting for project concrete, research evaluations, and other studies. Careful and knowledgeable handling of materials, mixing concrete, molding testspecimens, and curing test specimens is necessary. Many laboratories performing this i

20、mportant work are independently inspected or accredited. PracticeC1077 identifies and defines the duties, responsibilities, and minimum technical qualification requirements of laboratory personnel and the minimumrequirements for equipment used in testing concrete and concrete aggregates.4. Apparatus

21、4.1 Molds, GeneralMolds for specimens or fastenings thereto in contact with the concrete shall be made of steel, cast iron,or other nonabsorbent material, nonreactive with concrete containing portland or other hydraulic cements. Molds shall conformto the dimensions and tolerances specified in the me

22、thod for which the specimens are required. Molds shall hold their dimensionsand shape under all conditions of use. Watertightness of molds during use shall be judged by their ability to hold water poured intothem. Test procedures for watertightness are given in the section on Test Methods for Elonga

23、tion, Absorption, and Watertightnessof Specification C470/C470M. A suitable sealant, such as heavy grease, modeling clay, or microcrystalline wax, shall be usedwhere necessary to prevent leakage through the joints. Positive means shall be provided to hold base plates firmly to the molds.Reusable mol

24、ds shall be lightly coated with mineral oil or a suitable nonreactive release material before use.4.2 Cylinder Molds:Cylinder Molds:4.2.1 Molds for Casting Specimens Vertically shall conform to the requirements of 4.1 and Specification C470/C470M.4.2.2 Horizontal Molds for Creep Test Cylinders shall

25、 conform to the requirements of 4.1 and to the requirements for symmetryand dimensional tolerance in the section on General Requirements except for verticality requirements of SpecificationC470/C470M. The use of horizontal molds is intended only for creep specimens that contain axially embedded stra

26、in gages. Moldsfor creep cylinders to be filled while supported in a horizontal position shall have a filling slot parallel to the axis of the mold whichextends the full length to receive the concrete. The width of the slot shall be one half the diameter of the specimen. If necessarythe edges of the

27、 slot shall be reinforced to maintain dimensional stability. Unless specimens are to be capped or ground to produceplane ends, the molds shall be provided with two machined metal end plates at least 25 mm 1 in. thick and the working surfacesshall comply with the requirements for planeness and surfac

28、e roughness given in the section on Capping Plates of PracticeC617/C617M. Provision shall be made for fixing both end plates firmly to the mold. The inside surface of each end plate shall beprovided with at least three lugs or studs approximately 25 mm 1 in. long, firmly fastened to the plate for em

29、bedment in theconcrete. One base plate shall be drilled from the inside at an angle to permit the lead wire from the strain gage to exit the specimenthrough the edge of the plate. Provision shall be made for accurately positioning the strain gage. All necessary holes shall be assmall as possible to

30、minimize disturbance to subsequent strain measurements and shall be sealed to prevent leakage.4.3 Beam and Prism Molds shall be rectangular in shape (unless otherwise specified) and of the dimensions required to producethe desired specimen size. The inside surfaces of the molds shall be smooth and f

31、ree from indentations. The sides, bottom, andends shall be at right angles to each other and shall be straight and true and free of warpage. Maximum variation from the nominalcross section shall not exceed 3 mm 18 in. for molds with depth or breadth of 150 mm 6 in. or more, or 2 mm 116 in. for molds

32、of smaller depth or breadth. Except for flexure specimens, molds shall not vary from the nominal length by more than 2 mm116 in. Flexure molds shall not be shorter than 2 mm 116 in. of the required length, but may exceed it by more than that amount.4.4 Tamping RodA round, smooth, straight, steel rod

33、 with a diameter conforming to the requirements in Table 2. The lengthof the tamping rod shall be at least 100 mm 4 in. greater than the depth of the mold in which rodding is being performed, butnot greater than 600 mm 24 in. in overall length (see Note 2). The rod shall have the tamping end or both

34、 ends rounded to ahemispherical tip of the same diameter as the rod.NOTE 2Arod length of 400 mm 16 in. to 600 mm 24 in. meets the requirements of the following: Practice C31/C31M, Test Method C138/C138M,Test Method C143/C143M, Test Method C173/C173M, and Test Method C231/C231M.4 Available from Ameri

35、can Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI 48333-9094, http:/www.aci-int.org.C192/C192M 1424.5 MalletsA mallet with a rubber or rawhide head weighing 0.6 6 0.2 kg 1.25 6 0.50 lb shall be used.4.6 Vibrators:4.6.1 Internal VibratorsThe vibrator frequency shall be at least 9000 v

36、ibrations per minute 150 Hz while the vibrator isoperating in the concrete. The diameter of a round vibrator shall be no more than one fourth the diameter of the cylinder mold orone fourth the width of the beam or prism mold. Other shaped vibrators shall have a perimeter equivalent to the circumfere

37、nceof an appropriate round vibrator. The combined length of the vibrator shaft and vibrating element shall exceed the depth of thesection being vibrated by at least 75 mm 3 in. The vibrator frequency shall be checked with a vibrating-reed tachometer or othersuitable device at least every two years o

38、r as recommended by the manufacturer.NOTE 3For information on size and frequency of various vibrators and method to check vibrator frequency, see ACI 309R.4.6.2 External VibratorsThe two types of external vibrators permitted are either table or plank. The external vibratorfrequency shall be 3600 vib

39、rations per minute (60 Hz) or higher.4.6.3 Provisions shall be made for clamping the mold securely to the apparatus for both types of vibrators.NOTE 4Vibratory impulses are frequently imparted to a table or plank vibrator through electromagnetic means, or by use of an eccentric weight onthe shaft of

40、 an electric motor or on a separate shaft driven by a motor.4.7 Small ToolsTools and items such as shovels, pails, trowels, wood float, blunted trowels, straightedge, feeler gage, scoops,rulers, rubber gloves, and metal mixing bowls shall be provided.4.8 Slump ApparatusThe apparatus for measurement

41、of slump shall conform to the requirements of Test MethodC143/C143M.4.9 Sampling and Mixing PanThe pan shall be flat-bottom and of heavy-gage metal, watertight, of convenient depth, and ofsufficient capacity to allow easy mixing by shovel or trowel of the entire batch; or, if mixing is by machine, t

42、o receive the entirebatch on discharge of the mixer and allow remixing in the pan by trowel or shovel.4.10 Wet-Sieving EquipmentIf wet-sieving is required, the equipment shall conform to the requirements of PracticeC172/C172M.4.11 Air Content ApparatusThe apparatus for measuring air content shall co

43、nform to the requirements of either Test MethodsC231/C231M or C173/C173M.4.12 ScalesScales for determining the mass of batches of materials and concrete shall be accurate within 0.3 % of the test loadat any point within the range of use.NOTE 5In general the mass of small quantities should not be det

44、ermined on large capacity scales. In many applications the smallest mass determinedon a scale should be greater than about 10 % of the maximum capacity of the scale; however, this will vary with the performance characteristics of thescale and the required accuracy of the determination.Acceptable sca

45、les used for determining the mass for concrete materials preferably should determinemass accurately to about 0.1 % of total capacity and the foregoing precaution is applicable. However, certain analytical and precision balances areexceptions to this rule and should weigh accurately to 0.001 %. Parti

46、cular care must be exercised in measuring small quantities of material by determiningthe difference between two much larger masses.4.13 Temperature Measuring DeviceThe temperature measuring device shall conform to the requirements of Test MethodC1064/C1064M.4.14 Concrete MixerA power-driven concrete

47、 mixer shall be a revolving drum, tilting mixer, or suitable revolving pan orrevolving-paddle mixer capable of thoroughly mixing batches of the prescribed sizes at the required slump.NOTE 6Apan mixer is usually more suitable for mixing concrete with less than 25 mm 1 in. slump than a revolving drum

48、mixer. The rate of rotation,degree of tilt, and rated capacity of tilting mixers are not always suitable for laboratory mixed concrete. It may be found desirable to reduce the rate ofTABLE 1 Number of Layers Required for SpecimensSpecimen Type and Size Mode ofConsolidationNumbers of Layersof Approxi

49、mateEqual DepthCylinders:Diameter, mm in.75 to 100 3 or 4 rodding 2150 6 rodding 3225 9 rodding 4up to 225 9 vibration 2Prisms and horizontal creep Cylinders:Depth, mm in.up to 200 8 rodding 2over 200 8 rodding 3 or moreup to 200 8 vibration 1over 200 8 vibration 2 or moreC192/C192M 143rotation, decrease the angle of tilt from the horizontal, and use the mixer at somewhat less than the manufacturers rated capacity.5. Specimens5.1 Cylindrical SpecimensCylinder dimensions shall be as stipulated in th

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1