ASTM C507-2012 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格》.pdf

上传人:priceawful190 文档编号:466860 上传时间:2018-11-27 格式:PDF 页数:11 大小:121.42KB
下载 相关 举报
ASTM C507-2012 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格》.pdf_第1页
第1页 / 共11页
ASTM C507-2012 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格》.pdf_第2页
第2页 / 共11页
ASTM C507-2012 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格》.pdf_第3页
第3页 / 共11页
ASTM C507-2012 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格》.pdf_第4页
第4页 / 共11页
ASTM C507-2012 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格》.pdf_第5页
第5页 / 共11页
亲,该文档总共11页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:C50711 Designation: C507 12Standard Specification forReinforced Concrete Elliptical Culvert, Storm Drain, andSewer Pipe1This standard is issued under the fixed designation C507; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev

2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification

3、 covers reinforced elliptically shaped concrete pipe to be used for the conveyance of sewage, industrialwastes, and storm water, and for the construction of culverts.1.2 Pipe designed for placement with the major axis horizontal shall be designated as “Horizontal Elliptical Pipe.” Pipe designedfor p

4、lacement with the major axis vertical shall be designated as “Vertical Elliptical Pipe.”1.3 This specification is the inch-pound companion to Specification C507M; therefore, no SI equivalents are presented in thespecification.NOTE 1This specification is a manufacturing and purchase specification onl

5、y, and does not include requirements for bedding, backfill, or therelationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of thisproduct depends upon the proper selection of the class of pipe, type of bedding an

6、d backfill, and care that the installation conforms to the constructionspecifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipespecified and provide inspection at the construction site.2. Referenced D

7、ocuments2.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelA82/A82MSpecification for Steel Wire, Plain, for Concrete ReinforcementA185/A185MSpecification for Steel Welded Wire Reinforcement, Plain, for ConcreteA496/A496MSpecification for Steel Wire, Deformed, for Concrete Reinforc

8、ementA497/A497MSpecification for Steel Welded Wire Reinforcement, Deformed, for ConcreteA615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concrete ReinforcementA706/A706M Specification for Low-Alloy Steel Deformed and Plain Bars for Concrete ReinforcementA1064/A1064M Specificatio

9、n for Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for ConcreteC33 Specification for Concrete AggregatesC150 Specification for Portland CementC260 Specification for Air-Entraining Admixtures for ConcreteC309 Specification for Liquid Membrane-Forming Compounds for Curing ConcreteC494

10、/C494M Specification for Chemical Admixtures for ConcreteC497 Test Methods for Concrete Pipe, Manhole Sections, or TileC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in ConcreteC822 Terminology Relating to Concrete Pip

11、e and Related ProductsC989 Specification for Slag Cement for Use in Concrete and MortarsC1017/C1017M Specification for Chemical Admixtures for Use in Producing Flowing ConcreteC1116 Specification for Fiber-Reinforced Concrete and Shotcrete3. Terminology3.1 DefinitionsFor definitions of terms relatin

12、g to concrete pipe, see Terminology C822.1This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on Reinforced Sewerand Culvert Pipe.Current edition approved Feb.May 1, 2011.2012. Published March 2011.June 2012. Ori

13、ginally approved in 1963. Last previous edition approved in 20102011 asC50710b.C507 11. DOI: 10.1520/C0507-112.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the

14、standards Document Summary page on the ASTM website.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes acc

15、urately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United St

16、ates.4. Classification4.1 Pipe manufactured according to this specification shall be of five classes each for horizontal elliptical and vertical ellipticalpipe with identification as follows:C507 122Horizontal Elliptical Pipe Vertical Elliptical PipeClass HE-A Class VE-IIClass HE-I Class VE-IIIClass

17、 HE-II Class VE-IVClass HE-III Class VE-VClass HE-IV Class VE-VI4.2 The strength requirements for horizontal elliptical pipe are prescribed in Table 1 and for vertical elliptical pipe are prescribedin Table 2.5. Basis of Acceptance5.1 Unless otherwise designated by the owner at the time of, or befor

18、e, placing an order, there are two separate and alternativebases of acceptance. Independent of the method of acceptance, the pipe shall be designed to meet both the 0.01-in. crack andultimate strength requirements.5.1.1 Acceptance on Basis of Plant Load-Bearing Tests, Material Tests, and Inspection

19、of Manufactured Pipe for Visual Defectsand ImperfectionsAcceptability of the pipe in all diameters and classes produced in accordance with 7.1 or 7.2 shall bedetermined by the results of the three-edge-bearing tests as defined in 11.3.1; by such material tests as are required in 6.2, 6.3, 6.5,and 6.

20、6; by an absorption test of the concrete from the wall of the pipe as required in 11.9; and by visual inspection of the finishedpipe to determine its conformance with the accepted design and its freedom from defects.5.1.2 Acceptance on the Basis of Material Tests and Inspection of Manufactured Pipe

21、for Defects and ImperfectionsAcceptability of the pipe in all diameters and classes produced in accordance with 7.1 or 7.2 shall be determined by the resultsTABLE 1 Design Requirements for Horizontal Elliptical (HE) PipeANOTE 1The test load in pounds per linear foot equals D-load 3 inside span in fe

22、et.NOTE 2Single cage reinforcement, providing tension steel at the top, bottom, and springline, shall be permitted instead of double cage reinforcement.The area of such reinforcement shall be 112 % of the tabulated inner cage area.NOTE 3An inner and outer cage plus quadrant mats shall be permitted i

23、nstead of double cage reinforcement. The area of such reinforcement shallbe in accordance with Fig. 1.NOTE 4An inner and outer cage plus a middle cage shall be permitted instead of double cage reinforcement. The area of such reinforcement shallbe in accordance with Fig. 2.DesignatedDiameter,Equivale

24、ntRoundSize, in.DesignatedRise, in. 3Span, in.MinimumWallThickness,in.Reinforcement, in.2/linear ftClass HE-A Class HE-I Class HE-II Class HE-III Class HE-IVD-Loads0.01 = 600Ult = 9000.01 = 800Ult = 12000.01 = 1000Ult = 15000.01 = 1350Ult = 20000.01 = 2000Ult = 3000InCageOutCageInCageOutCageInCageOu

25、tCageInCageOutCageInCageOutCage1824273033363942485414 3 2319 3 3022 3 3424 3 3827 3 4229 3 4532 3 4934 3 5338 3 6043 3 68234314312334334412434551260.080.110.140.100.120.110.120.150.170.20.0.100.120.110.120.150.170.200.110.150.180.120.170.150.170.200.230.27.0.120.170.150.170.200.230.270.140.190.230.1

26、70.210.190.210.240.270.34.0.170.210.190.210.240.270.340.190.260.310.230.270.260.290.330.390.45.0.230.270.260.290.330.390.450.270.390.450.340.410.390.440.50.0.340.410.390.440.5060 48 3 76 612 0.24 0.24 0.32 0.32 0.40 0.40 0.53 0.53 . . . . . .66 53 3 83 7 0.27 0.27 0.36 0.36 0.45 0.45 0.60 0.60 . . .

27、 . . .72 58 3 91 712 0.31 0.31 0.41 0.41 0.52 0.52 0.70 0.70 . . . . . .78 63 3 98 8 0.34 0.34 0.45 0.45 0.56 0.56 0.78 0.78 . . . . . .84 68 3 106 812 0.38 0.38 0.50 0.50 0.63 0.63 0.88 0.88 . . . . . .90 72 3 113 9 . . . . . . . . . .96 77 3 121 912 . . . . . . . . . .102 82 3 128 934 . . . . . .

28、. . . .108 87 3 136 10 . . . . . . . . . .114 92 3 143 1012 . . . . . . . . . .120 97 3 151 11 . . . . . . . . . .132 106 3 166 12 . . . . . . . . . .144 116 3 180 13 . . . . . . . . . .Concrete strengthB, psi 4000 4000 4000 18 to 66 in.4000400072 to 84 in.5000AFor sizes and loads beyond those shown

29、 in this table, pipe designs are available that make use of one or a combination of the following: shear steel, multiple cages,or thicker walls in accordance with the provisions of 7.3.BConcrete strength for designs with reinforcement tabulated. For modified or special designs, see 7.3.C507 123of su

30、ch material tests as are required in 6.2, 6.3, 6.5, and 6.6; by crushing tests on concrete cores or cured concrete cylinders; byan absorption test of the concrete from the wall of the pipe for each mix design that is used on an order; and by inspection of thefinished pipe, including amount and place

31、ment of reinforcement, to determine its conformance with the accepted design and itsfreedom from defects.5.1.3 When agreed upon by the owner and the manufacturer, any portion or any combination of the tests itemized in 5.1.1 or5.1.2 may form the basis of acceptance.5.2 Age for AcceptancePipe shall b

32、e considered ready for acceptance when they conform to the requirements as indicated bythe specified tests.6. Materials6.1 The aggregate shall be so sized, graded, proportioned, and mixed with such proportions of portland cement, blendedhydraulic cement, or portland cement and supplementary cementin

33、g materials, or admixtures, if used, or a combination thereof,and water to produce a homogeneous concrete mixture of such quality that the pipe will conform to the test and designrequirements of this specification. In no case, however, shall the proportion of portland cement, blended hydraulic cemen

34、t, or acombination of portland cement and supplementary cementing materials be less than 470 lb/yd3.6.2 Cementitious Materials:6.2.1 CementCement shall conform to the requirements of Specification C150, or shall be portland blast-furnace slag cement,or slag modified portland cement, or portland-pozz

35、olan cement conforming to the requirements of Specification C595, except thatthe pozzolan constituent in the Type IP portland pozzolan cement shall be fly ash.6.2.2 Ground Granulated Blast-Furnace Slag (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120 ofSpecification C989.6.2.3 Fly

36、AshFly ash shall conform to the requirements of Class F or Class C of Specification C618.6.2.4 Allowable Combinations of Cementitious MaterialsThe combination of cementitious materials used in the concrete shallbe one of the following:6.2.4.1 Portland cement only,TABLE 2 Design Requirements for Vert

37、ical Elliptical PipeANOTE 1Test load in pounds per linear foot equals D-load 3 inside span in feet.NOTE 2An inner and outer cage plus quadrant mats shall be permitted instead of double cage reinforcement. The area of such reinforcement shallbe in accordance with Fig. 3.NOTE 3Single cage reinforcemen

38、t, providing tension steel at the top, bottom, and springline, shall be permitted instead of double cage reinforcement.The area of such reinforcement shall be 112 % of the tabulated inner cage area.NOTE 4An inner and outer cage plus a middle cage shall be permitted instead of double cage reinforceme

39、nt. The area of such reinforcement shallbe in accordance with Fig. 4.DesignatedDiameter,EquivalentRoundSize, in.DesignatedRise, in. 3Span, in.MinimumWallThickness,in.Reinforcement, in.2/linear ftClass VE-II Class VE-III Class VE-IV Class VE-V Class VE-VID-Loads0.01 = 1000Ult = 15000.01 = 1350Ult = 2

40、0000.01 = 2000Ult = 30000.01 = 3000Ult = 37500.01 = 4000Ult = 5000InCageOutCageInCageOutCageInCageOutCageInCageOutCageInCageOutCage3639424854606672788445 3 2949 3 3253 3 3460 3 3868 3 4376 3 4883 3 5391 3 5898 3 63106 3 6841243455126612771288120.080.090.100.110.120.160.180.210.230.260.050.050.060.07

41、0.080.100.110.120.140.160.110.120.120.150.180.210.240.270.310.350.070.070.080.090.110.120.150.170.190.210.160.180.200.210.270.310.360.410.470.530.100.110.120.120.160.190.210.240.270.320.230.260.290.330.400.470.55.0.140.160.170.200.240.270.33.0.310.350.380.440.53.0.190.210.230.260.32.90 113 3 72 9 .

42、. . . . . . . . .96 121 3 77 912 . . . . . . . . . .102 128 3 82 934 . . . . . . . . . .108 136 3 87 10 . . . . . . . . . .114 143 3 92 1012 . . . . . . . . . .120 151 3 97 11 . . . . . . . . . .132 166 3 106 12 . . . . . . . . . .144 180 3 116 13 . . . . . . . . . .Concrete strengthB, psi 4000 4000

43、 4000 5000 6000AFor sizes and loads beyond those shown in this table, pipe designs are available which make use of one or a combination of the following: shear steel, multiple cages,or thicker walls in accordance with the provisions of 7.3.BConcrete strength for designs with reinforcement tabulated.

44、 For modified or special designs, see 7.3.C507 1246.2.4.2 Portland blast furnace slag cement only,6.2.4.3 Slag modified portland cement only,6.2.4.4 Portland pozzolan cement only,6.2.4.5 A combination of portland cement and ground granulated blast-furnace slag,6.2.4.6 A combination of portland cemen

45、t and fly ash, or6.2.4.7 A combination of portland cement, ground granulated blast-furnace slag (not to exceed 25 % of the total cementitiousweight) and fly ash (not to exceed 25 % of the total cementitious weight.6.2.4.8 A combination of portland pozzolan cement and fly ash, provided the fly ash ad

46、ded does not exceed 25 % by weight ofthe portland pozzolan cement.6.3 AggregatesAggregates shall conform to Specification C33 except that the requirement for gradation shall not apply.6.4 Admixtures and BlendsThe following admixtures and blends are allowable:6.4.1 Air-entraining admixture conforming

47、 to Specification C260;6.4.2 Chemical admixture conforming to Specification C494/C494M;6.4.3 Chemical admixture for use in producing flowing concrete conforming to Specification C1017/C1017M; and6.4.4 Chemical admixture or blend approved by the owner.6.5 Steel ReinforcementReinforcement shall consis

48、t of wire conforming to Specification A82/A82M or SpecificationA496/A496M; or of wire reinforcement conforming to SpecificationA185/A185M or SpecificationA497/A497MReinforcementshall consist of wire conforming to SpecificationA1064/A1064M; or of bars conforming to SpecificationA36/A36M, Specificatio

49、nA615/A615M Grade 40 or 60, or Specification A706/A706M Grade 60.6.6 Synthetic FibersCollated fibrillated virgin polypropylene fibers may be used, at the manufacturers option, in concretepipe as a nonstructural manufacturing material. Only Type III synthetic fibers designed and manufactured specifically for use inconcrete and conforming to the requirements of Specification C1116 shall be accepted.7. Design7.1 Size and ShapeThe standard sizes of elliptical pipe shall be as listed in Table 1 and Table 2. The