ASTM D115-2007(2012) Standard Test Methods for Testing Solvent Containing Varnishes Used for Electrical Insulation《电绝缘用含清漆试验溶剂的标准试验方法》.pdf

上传人:Iclinic170 文档编号:509347 上传时间:2018-12-01 格式:PDF 页数:8 大小:128.74KB
下载 相关 举报
ASTM D115-2007(2012) Standard Test Methods for Testing Solvent Containing Varnishes Used for Electrical Insulation《电绝缘用含清漆试验溶剂的标准试验方法》.pdf_第1页
第1页 / 共8页
ASTM D115-2007(2012) Standard Test Methods for Testing Solvent Containing Varnishes Used for Electrical Insulation《电绝缘用含清漆试验溶剂的标准试验方法》.pdf_第2页
第2页 / 共8页
ASTM D115-2007(2012) Standard Test Methods for Testing Solvent Containing Varnishes Used for Electrical Insulation《电绝缘用含清漆试验溶剂的标准试验方法》.pdf_第3页
第3页 / 共8页
ASTM D115-2007(2012) Standard Test Methods for Testing Solvent Containing Varnishes Used for Electrical Insulation《电绝缘用含清漆试验溶剂的标准试验方法》.pdf_第4页
第4页 / 共8页
ASTM D115-2007(2012) Standard Test Methods for Testing Solvent Containing Varnishes Used for Electrical Insulation《电绝缘用含清漆试验溶剂的标准试验方法》.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D115 07 (Reapproved 2012)An American National StandardStandard Test Methods for TestingSolvent Containing Varnishes Used for Electrical Insulation1This standard is issued under the fixed designation D115; the number immediately following the designation indicates the year oforiginal ado

2、ption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods cover tests for solvent containingvarnishes primari

3、ly intended to provide electrical, mechanical,and chemical protection for electrical equipment. These testmethods include tests for control and performance as follows:Procedure SectionBuild 37-41Dielectric Strength 42-47Drainage 25-31Flash Point 17-19Nonvolatile Matter 20-24Oil Resistance 53-55Prepa

4、ration of Test Specimens 7Specific Gravity 9-12Temperature Index 48-49Time of Drying 32-36Varnish Compatibility 50-52Viscosity 13-161.2 Where the entire test method is included in this standard,the precision and bias are not known unless given in the statedmethod.1.3 The values stated in SI units ar

5、e to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practice

6、s and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 5.NOTE 1There is no equivalent IEC standard.2. Referenced Documents2.1 ASTM Standards:2D56 Test Method for Flash Point by Tag Closed Cup TesterD93 Test Methods for Flash Point by Pen

7、sky-MartensClosed Cup TesterD149 Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD202 Test Methods for Sampling and Testing UntreatedPaper Used for Electrical InsulationD287 Test Method for API Gravity of Crud

8、e Petroleum andPetroleum Products (Hydrometer Method)D295 Test Methods for Varnished Cotton Fabrics Used forElectrical InsulationD374 Test Methods for Thickness of Solid Electrical Insu-lationD580 Specification for Greige Woven Glass Tapes andWebbingsD1475 Test Method For Density of Liquid Coatings,

9、 Inks,and Related ProductsD1638 Method of Testing Urethane Foam Isocyanate RawMaterialsD1932 Test Method for Thermal Endurance of FlexibleElectrical Insulating VarnishesD2518 Specification for Woven Glass Fabrics for ElectricalInsulationD2519 Test Method for Bond Strength of Electrical Insu-lating V

10、arnishes by the Helical Coil TestD3145 Test Method for Thermal Endurance of ElectricalInsulating Varnishes by the Helical Coil MethodD3251 Test Method for Thermal Endurance Characteristicsof Electrical Insulating Varnishes Applied Over Film-Insulated Magnet WireD3278 Test Methods for Flash Point of

11、Liquids by SmallScale Closed-Cup ApparatusD3487 Specification for Mineral Insulating Oil Used inElectrical ApparatusD5032 Practice for Maintaining Constant Relative Humid-ity by Means of Aqueous Glycerin SolutionsD5423 Specification for Forced-Convection LaboratoryOvens for Evaluation of Electrical

12、InsulationE104 Practice for Maintaining Constant Relative Humidityby Means of Aqueous Solutions3. Terminology3.1 Definitions: Definitions:1These test methods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are the direct responsibility ofSubcommi

13、ttee D09.01 on Electrical Insulating Varnishes, Powders and Encapsulat-ing Compounds.Current edition approved April 1, 2012. Published April 2012. Originallyapproved in 1941. Last previous edition approved in 207 as D115 07. DOI:10.1520/D0115-07R12.2For referenced ASTM standards, visit the ASTM webs

14、ite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor

15、 Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.1 dielectric strengththe voltage gradient at whichdielectric failure of the insulating material occurs under spe-cific conditions of test.3.1.2 drainageof an insulating varnish, a measure of thevariation in thickness from top t

16、o bottom of a varnish filmobtained on the surface of a vertically dip coated panel after aspecified time and temperature.3.1.3 flash pointthe lowest temperature of the specimen,corrected to a pressure of 760 mm Hg (101.3 kPa), at whichapplication of an ignition source causes any vapor from thespecim

17、en to ignite under specified conditions of test.3.1.4 nonvolatile matterin insulating varnish, that portionof a varnish which is not volatilized when exposed to specifiedconditions; the value obtained is not necessarily equal to thecalculated solids incorporated during compounding.3.1.4.1 Discussion

18、For example, the theoretical chemicalsolids are often assumed to be the solid phase materialsincorporated in the varnish at the time of compounding. Manyof these solid phase intermediate materials will lose volatilefractions due to the specified conditions of the nonvolatilematter procedure. An exam

19、ple is phenolic resin.3.1.5 oil resistanceof insulating varnish, a measure of theretention of properties after exposure to a specified oil underspecified conditions of test.3.1.6 time of dryingof insulating varnish, the time re-quired for a film of varnish to dry to a tackfree state underspecified c

20、onditions.3.2 Definitions of Terms Specific to This Standard:3.2.1 build, nof an insulating varnish on copper, theaverage thickness of varnish film on one side of a copper panelthat has received a single coat of the varnish applied andmeasured under specified conditions.3.2.2 build, nof an insulatin

21、g varnish on glass cloth, theaverage overall thickness of strips of glass cloth that havereceived two dips of the varnish applied and measured underspecified conditions.3.2.3 tack free, adjcondition when a varnish has reachedthe point that the surface can be touched lightly without asensation of sti

22、ckiness.3.2.4 varnish, air-drying, na liquid resin system thatforms a dry, tack free coating, without the application of heat,either through evaporation of solvent or by reaction withatmospheric oxygen.3.2.5 varnish, baking, na liquid resin system that forms adry, tack free coating when exposed to e

23、levated temperatures.4. Significance and Use4.1 ControlThe following tests are useful for controlpurposes during the manufacture and use of varnishes, and fordetermining the uniformity of batches:4.1.1 Specific gravity,4.1.2 Viscosity,4.1.3 Flash point, and4.1.4 Nonvolatile matter by weight.4.2 Perf

24、ormanceThe following tests are useful for deter-mining the performance of varnishes during application anduse:4.2.1 Drainage,4.2.2 Time of drying,4.2.3 Build,4.2.4 Dielectric strength,4.2.5 Thermal endurance,4.2.6 Varnish compatibility,4.2.7 Salt water proofness, and4.2.8 Oil resistance.5. Hazards5.

25、1 WarningDo not use varnish at temperatures abovethe flash point when inadequate ventilation, and the possibilityof flames or sparks exist. Store varnish in sealed containers.The precautions shall also apply to the handling of the reagentsand solvents called for herein.6. Sampling6.1 For all tests t

26、he sample shall be taken from a represen-tative lot of the varnish under study. To avoid skin formationand escape of solvents, protect the sample by keeping it atroom temperature in a nearly filled, tightly sealed container.7. Preparation of Test Specimens7.1 Selection of SubstrateThe selection of t

27、he substrate isdetermined in part by application and in part by thermal class.Two types of substrates may be used: copper strip or glasscloth. Copper strip is generally not used for applications over180C (356F) due to oxidation.7.2 Copper Base:7.2.1 For tests that are to be performed upon the varnis

28、h asa film on a copper base, copper strips 38 mm (112 in.) in width,200 mm (8 in.) in length, and 0.127 6 0.08 mm (0.005 60.0003 in.) in thickness shall be used, unless otherwisespecified. Measure the thickness of these strips to the nearest0.002 mm (0.0001 in.). Clean the strips with a suitable sol

29、vent(Note 2), then polish thoroughly with No. 000 steel wool. Wipethe strips free of any fingerprints or metal particles with thesolvent and a lint-free cloth. If the strips are not to be usedimmediately, they should be kept stored in a noncorrosivevarnish solvent.NOTE 2Xylene and denatured alcohol

30、(1:1) have been found to besuitable cleaning solvents. V.M. dielectric strength; drainage; flash point; non-volatile matter; oil resistance; solvent varnish; specific gravity;temperature index; time of drying; varnish; varnish compat-ibility; viscositySUMMARY OF CHANGESCommittee D09 has identified t

31、he location of selected changes to these test methods since the last issue,D115 02, that may impact the use of these test methods. (Approved May 1, 2007)(1) Added new 3.2.3 and renumbered subsequent paragraphs. (1) Revised 14.1.ASTM International takes no position respecting the validity of any pate

32、nt rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision

33、at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comme

34、nts will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted

35、 by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).D115 07 (2012)8

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1