ASTM D1514-2015 Standard Test Method for Carbon Black&x2014 Sieve Residue《炭黑筛余物的标准试验方法》.pdf

上传人:sumcourage256 文档编号:509958 上传时间:2018-12-01 格式:PDF 页数:3 大小:72.29KB
下载 相关 举报
ASTM D1514-2015 Standard Test Method for Carbon Black&x2014 Sieve Residue《炭黑筛余物的标准试验方法》.pdf_第1页
第1页 / 共3页
ASTM D1514-2015 Standard Test Method for Carbon Black&x2014 Sieve Residue《炭黑筛余物的标准试验方法》.pdf_第2页
第2页 / 共3页
ASTM D1514-2015 Standard Test Method for Carbon Black&x2014 Sieve Residue《炭黑筛余物的标准试验方法》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D1514 15Standard Test Method forCarbon BlackSieve Residue1This standard is issued under the fixed designation D1514; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses in

2、dicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the waterwash sieve residue in regular untreated carbon blacks. It maynot be applicable to oil-treated carbon blac

3、ks because the oilwould prevent proper wetting of the black by water.1.2 The values stated in SI units are to be regarded as thestandard. The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is

4、 theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 6.2. Referenced Documents2.1 ASTM Standards:2D1799 Practice for Carbon Blac

5、kSampling PackagedShipmentsD1900 Practice for Carbon BlackSampling Bulk Ship-mentsD4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustriesE11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Summary of Test Method3.1 A samp

6、le of carbon black is washed with water througha wire-mesh screen of a specified size until all that remains isa non-carbon black residue. This residue is dried, weighed, andthe amount of residue is expressed as mg/kg (ppm) of theoriginal sample.4. Significance and Use4.1 The quantity of sieve resid

7、ue of carbon black is impor-tant in some molded or extruded products as it may relate to thesurface appearance of those products. The maximum residue ineach application is normally determined and agreed to betweenthe user and the producer.5. Apparatus5.1 Sieve and Filtering Apparatus,3, 4as shown in

8、 Fig. 1.5.2 Balance, with a sensitivity of 0.01 g.5.3 Analytical Balance, with a sensitivity of 0.1 mg.5.4 Oven, gravity-convection type, capable of temperatureregulation within 61C at 125C and temperature uniformitywithin 65C.5.5 Sieves, of either phosphor bronze or stainless steel. Thesieve shall

9、be in accordance with Specification E11. The sieveto be used shall be agreed upon between the purchaser and theseller.5.6 Weighing Dishes.6. Precautions6.1 Keep the apparatus clean at all times to prevent con-tamination.6.2 Examine the sieves each time they are used to make surethat no cracks or hol

10、es have developed.6.3 Examine the strainer periodically to ascertain that thefilter screen is in good condition.7. Sampling7.1 Samples shall be taken in accordance with PracticeD1799 or Practice D1900.1This test method is under the jurisdiction of ASTM Committee D24 on CarbonBlack and is the direct

11、responsibility of Subcommittee D24.31 on Non-CarbonBlack Components of Carbon Black.Current edition approved June 15, 2015. Published August 2015. Originallyapproved in 1957. Last previous edition approved in 2011 as D1514 04 (2011).DOI: 10.1520/D1514-15.2For referenced ASTM standards, visit the AST

12、M website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Sieve and filtering apparatus, available from Titan Specialties, Inc., P.O. Box2316, Pampa, TX 70066-2316

13、, has been found suitable. The A2000 Test Set fromKrahnen IQS, GmbH, Paffrather Str. 1315, D-51069 Koeln, Germany, has beenfound suitable. An ASTM specified apparatus modified with an enlarged funnel legID (5.080 cm or 2.0 in.) and sieve screen OD (6.032 cm or 2.375 in.) has also beenfound suitable.

14、4The sole source of supply of housing No. 20 and cartridge No. 30 known to thecommittee at this time is Amtek, Plymouth Products Division, 562 Indiana Ave.,Sheboygan, WI 53081. If you are aware of alternative suppliers, please provide thisinformation to ASTM International Headquarters. Your comments

15、 will receivecareful consideration at a meeting of the responsible technical committee,1whichyou may attend.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States18. Calibration8.1 Calculate the sieve residue to the nearest mg/kg (ppm)as fol

16、lows:R 5 W/S! 3106(1)where:R = sieve residue, mg/kg (ppm),W = mass of sieve residue, g, andS = mass of sample, g.9. Procedure9.1 Prior to making a test, clean the strainer by openingvalves A and B and closing valve C as shown in Fig. 1. Allowthe strainer to wash for 2 min.9.2 Close valve B and open

17、valve C. With valves A and Ccompletely open, regulate the water pressure by means of areducing valve. The recommended water pressure is 207 6 34kPa (30 6 5 lbf/in.2).9.3 After the water pressure has been regulated, attach thesieve holder with a 50-mm (2-in.) diameter sieve to the funneland allow the

18、 water to run through it for 3 min. Stop the waterflow by closing valves A and C. Examine the sieve forparticles; if none are observed, the apparatus is ready for use.9.4 Weigh 100.0 g of the carbon black on the balance.9.5 Attach the proper sieve to the funnel and start the waterflow by opening val

19、ves A and C.9.6 Add the carbon black slowly to the funnel to preventplugging of the sieve.NOTE 1If desired it is permissible to utilize wetting agents to facilitatedispersion. Care must be taken to ensure that all of the solid material istransferred from the vessel used for dispersing the black into

20、 the funnel ofthe washing apparatus.9.7 Use a gentle stream of water from the hose attached tovalve D to wash down any carbon black on the sides of thefunnel.9.8 Continue washing until the wash water coming throughthe sieve is clear.9.9 Remove the sieve holder and sieve from the funnel andrub the re

21、sidue lightly with the finger to disaggregate any hardcarbon black lumps which may not have been thoroughly wetby the water.9.10 Replace the sieve holder and sieve and wash for anadditional 2 min.9.11 Remove the sieve holder and sieve and dry for1hat125C.9.12 Transfer the dried residue to a piece of

22、 smooth whitebond paper and rub gently to remove any carbon blackremaining on the residue. Rub until the white paper no longershows any smears.NOTE 2The purpose of gently rubbing the residue is to remove anyblack that may be clinging to the gritty residue. Do not apply excessiveforce when rubbing, a

23、s this action may fracture the residue allowing it toescape, or may trap the residue in the paper causing a low gritdetermination. Similarly, do not wear gloves when performing this step, asthe residue may be trapped in the glove material, giving a low result.9.13 Brush all the loose residue to a ta

24、red weighing dish andweigh to the nearest 0.1 mg using the analytical balance.10. Report10.1 Report the following information:10.1.1 Proper identification of the sample,10.1.2 Identification of the sieve number, and10.1.3 Result of the determinations reported to the nearestmg/kg (ppm).11. Precision

25、and Bias11.1 These precision statements have been prepared inaccordance with Practice D4483. Refer to this practice forterminology and other statistical details.11.2 The precision results in this precision and bias sectiongive an estimate of the precision of this test method with thematerials used i

26、n the particular interlaboratory program de-scribed below. The precision parameters should not be used foracceptance or rejection testing of any group of materialswithout documentation that they are applicable to those par-ticular materials and the specific testing protocols of the testmethod. Any a

27、ppropriate value may be used from Table 1.Atype 1 interlaboratory precision program was conducted asdetailed in Table 2. Both repeatability and reproducibilityrepresent short-term (daily) testing conditions. The testing wasperformed using two operators in each laboratory performingthe test once on e

28、ach of two days (total of four tests). A testresult is the value obtained from a single determination.Acceptable difference values were not measured. The betweenNOTE 1Industrial/O.E.M. filter and pleated polyester fabric reusablecartridges have been found to be a satisfactory strainer.4NOTE 2Corrosi

29、on-free piping must be used.NOTE 3Detailed drawings can be obtained from Test MethodD1514 88a.NOTE 4Spray nozzle: Part No. 460.746.30 BE available from LechlerInc., 445 Kautz Rd., St. Charles, IL 60174, or Titan Specialties Inc., P.O.Box 2316, Pampa, TX 70066-2316.FIG. 1 Schematic Diagram of Apparat

30、us for Sieve Residue Deter-minationD1514 152operator component of variation is included in the calculatedvalues for (r) and (R).11.3 The results of the precision calculations for this test aregiven in Table 1. The materials are arranged in ascending“mean level” order.11.4 RepeatabilityThe pooled rel

31、ative repeatability, (r),ofthis test method has been established as 80.8 %. Any othervalue in Table 1 may be used as an estimate of repeatability, asappropriate. The difference between two single test results (ordeterminations) found on identical test material under therepeatability conditions presc

32、ribed for this test will exceed therepeatability on an average of not more than once in 20 casesin the normal and correct operation of the method. Two singletest results that differ by more than the appropriate value fromTable 1 must be suspected of being from different populationsand some appropria

33、te action taken.NOTE 3Appropriate action may be an investigation of the test methodprocedure or apparatus for faulty operation or the declaration of asignificant difference in the two materials, samples, and so forth, whichgenerated the two test results.11.5 ReproducibilityThe pooled relative reprod

34、ucibility,(R), of this test method has been established as 180 %. Anyother value in Table 1 may be used as an estimate ofreproducibility, as appropriate. The difference between twosingle and independent test results found by two operatorsworking under the prescribed reproducibility conditions indiff

35、erent laboratories on identical test material will exceed thereproducibility on an average of not more than once in 20 casesin the normal and correct operation of the method. Two singletest results produced in different laboratories that differ bymore than the appropriate value from Table 1 must bes

36、uspected of being from different populations and some appro-priate investigative or technical/commercial action taken.11.6 BiasIn test method terminology, bias is the differencebetween an average test value and the reference (true) testproperty value. Reference values do not exist for this testmetho

37、d, since the value or level of the test property isexclusively defined by the test method. Bias, therefore, cannotbe determined.12. Keywords12.1 carbon black; non-carbon black residue; sieve residue;water wash sieve residueASTM International takes no position respecting the validity of any patent ri

38、ghts asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at an

39、y time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments w

40、ill receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by A

41、STM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail);

42、or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 1 Precision Parameters for D1514 Sieve Residue, (Type 1(No. 325 Sieve) Precision)Units mg/

43、kg (ppm)Material Mean Level Sr (r) SR (R)IRB#6 (N330) 18.3 6.0 93.3 13.1 203N762 18.3 7.4 114 9.7 150SRB A5 (N135) 20.8 5.1 69.5 9.7 132N550 64.3 10.4 45.9 24.7 109N650 75.7 20.2 75.6 46.7 174Average 39.5Pooled Values 11.3 80.8 25.1 180TABLE 2 Interlaboratory Precision ProgramNominal Test Period Material Number of LaboratoriesMarch 1996 N650 49October 1996 IRB#6 (N330) 41March 1997 N762 45September 1997 SRB A5 (N135) 42March 1998 N550 47D1514 153